Introduction to TDAONBGMFUVP Edward Gash 11 Dec 2003.

Slides:



Advertisements
Similar presentations
Raman Spectroscopy A) Introduction IR Raman
Advertisements

CAVITY RING DOWN SPECTROSCOPY
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
What experiments should we be doing? Dion L. Heinz University of Chicago.
1.5 Types of lasers Lasers may be classified according to several criteria: Whether the gain medium is a gas, liquid, or solid Fixed frequency or tuneable.
Molecular Fluorescence Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Light Amplification by Stimulated
Excimer and Dye lasers Helga Dögg Flosadóttir Nútíma Ljósfræði Vor 2008.
EM Radiation Sources 1. Fundamentals of EM Radiation 2. Light Sources
Dye lasers The gain medium in a dye lasers is a solution made with an organic dye molecule. The solution is intensely coloured owing to the very strong.
Update on the Leicester lab studies (WP2.2 cavity ringdown spectroscopy) Stephen Ball & Simon Neil (Leicester University) CAVIAR science meeting, NPL,
1.2 Population inversion Absorption and Emission of radiation
EM Radiation Sources 1. Fundamentals of EM Radiation 2. Light Sources 3. Lasers.
Lesson17. Heterogeneous and cloud processes Wide range of physical and chemical of substrate surfaces for heterogeneous reactions to take place. Clouds.
Atomic Absorption Spectroscopy (AAS)
Absorption and emission processes
Spectrophotometric Analysis
Electronic Spectroscopy of long Carbon Chains HC 2n H (n= 8-13) in the Gas Phase Felix Güthe*, Hongbin Ding, Thomas Pino and John P. Maier Institut für.
Stimulated Raman scattering If high enough powered radiation is incident on the molecule, stimulated Anti-Stokes radiation can be generated. The occurrence.
Fiber Optic Light Sources
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Chapter 5: Wave Optics How to explain the effects due to interference, diffraction, and polarization of light? How do lasers work?
Non-Instrumental Methods
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Laser Principle Eman Ali Ateeq.
Illumination and Filters Foundations of Microscopy Series Amanda Combs Advanced Instrumentation and Physics.
TYPES OF LASER Solid State lasers:Ruby laser, Nd:YAG laser, Nd:Glass laser Gas lasers:He-Ne laser, CO 2 laser, Argon laser Liquid/Dye lasers:Polymethene.
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
 PART Requirements for Spectroscopic Techniques for Polymers 1. High resolution 2. High sensitivity (>1%) 3. High selectivity between molecular.
Laser Spectroscopy Group Department of Physics NUI - University College Cork Cork, Ireland.
Masters Course: Experimental Techniques Detection of molecular species (with lasers) Techniques Direct absorption techniques Cavity Ring Down Cavity Enhanced.
1 Scintillators  One of the most widely used particle detection techniques Ionization -> Excitation -> Photons -> Electronic conversion -> Amplification.
An Introduction. The first step on the road to laser was the publication of paper by Albert Einstein in 1916 –describing how atoms could interact with.
1 P1X: Optics, Waves and Lasers Lectures, Lasers and their Applications i) to understand what is meant by coherent and incoherent light sources;
B.SC.II PAPER-B (OPTICS and LASERS)
Chapter 10. Laser Oscillation : Gain and Threshold
PHYSICS DEPARTMENT.
All-optical control of light on a silicon chip Vilson R. Almeida, Carlos A. Barrios, Roberto R. Panepucci & Michal Lipson School of Electrical and Computer.
Lecture 2 INTRODUCTION TO SPECTROMETRIC METHODS Copyright ©The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Electronic Transition of Ruthenium Monoxide Na Wang, Y. W. Ng and A. S.-C. Cheung Department of Chemistry The University of Hong Kong.
Fluorescence Spectroscopy
Haifeng Huang and Kevin K. Lehmann
Cavity ring down spectroscopy 14 February 2012 CE 540.
LASERS AND SPECTROSCOPY . EXCITING MOLECULES  Molecules can be excited using either broadband or monochromatic light. Spectra obtained using monochromatic.
-Plasma can be produced when a laser ionizes gas molecules in a medium -Normally, ordinary gases are transparent to electromagnetic radiation. Why then.
4-Level Laser Scheme nn  m  →  n  excitation  n  →  m  radiative decay slow  k  →  l  fast(ish)  l  →  m  fast to maintain population.
Development of a System for High Resolution Spectroscopy with an Optical Frequency Comb Dept. of Applied Physics, Fukuoka Univ., JST PRESTO, M. MISONO,
Fluorescence spectroscopy, Einstein’s coefficients Consider a molecule with two energy levels S a and S b The rate of transition.
1.1 What’s electromagnetic radiation
Numerical and experimental study of the mode tuning technique effects. Application to the cavity ring-down spectroscopy. J. Remy, G.M.W. Kroesen, W.W.
Introduction to PhD research Edward Gash 30 June 2004.
SHRI DADAJI INSTITUTE OF TECHNOLOGY & SCIENCE A SEMINAR ON LASER COMMUNICATION PRESENTED BY: HITESH SILARPURIYA E.C. FOURTH SEM.
Introduction to Infrared Spectroscopy
Laserlaser. Laser printer Laser pointer Laser: everywhere in your life.
ThemesThemes > Science > Physics > Optics > Laser Tutorial > Creating a Population Inversion Finding substances in which a population inversion can be.
Multi-step and Multi-photon Excitation Studies of Group-IIB Elements
Molecular Fluorescence Spectroscopy
Chem. 133 – 3/9 Lecture.
Flame Emission Spectrometry
Ultrafast Spectroscopy
Light Amplification by Stimulated
MEDICAL LASER SYSTEMS Assist Prof. Dr. Lutfi Ghulam Awazli
Chapter 12 Laser-Induced Chemical Reactions 1. Contents  Chapter Overview  Organic Chemical Syntheses  Organic Photochemistry  Lasers as a Photochemical.
4-Level Laser Scheme The general view was that it would be impossible or at least very difficult to achieve population inversion relative to the ground.
SPECTROPHOTOMETRY Applied Chemistry.
Photon Physics ‘08/’09 Thijs Besseling
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Spectrophotometric Analysis
Presentation transcript:

Introduction to TDAONBGMFUVP Edward Gash 11 Dec 2003

Introduction to TDAONBGMFUVP Edward Gash 11 Dec 2003 Introduction to ‘Time-dependent absorption of naphthalene buffer gas mixtures following UV photolysis’

Outline Introduction Experimental Results What? Why?

Introduction absorption laser light at 650 nm naphthalene UV laser pulses In this experiment, measured is the absorption of laser light at 650 nm by a naphthalene buffer gas mixture that as been photolysed by UV laser pulses. Naphthalene Naphthalene is a polycyclic aromatic hydrocarbon. White crystalline solid. Commonly known as mothballs. Vapour pressure at room tempature is mbar. C 10 H 8

Introduction absorption laser light at 650 nm UV laser pulses In this experiment, measured is the absorption of laser light at 650 nm by a naphthalene buffer gas mixture that as been photolysed by UV laser pulses. UV laser pulses UV laser pulses: the excimer laser in the lab produces pulses of UV light at 308nm. EX-700 pulsemaster XeCl laser. Maximum pulse energy of 100 mJ Pulse length of 15 ns. Usually run at a repetition rate of Hz. Can be triggered internally or with pulses from the computer.

Introduction absorption laser light at 650 nm In this experiment, measured is the absorption of laser light at 650 nm by a naphthalene buffer gas mixture that as been photolysed by UV laser pulses. Laser light at 650 nm Laser light at 650 nm: this is produced by a dye laser. Hyperdye 700 laser, containing DCM. The dye in the laser is ‘pumped’ using the excimer laser. A grating in the dyelaser allows the wavelength to be tuned. DCM allows tuning from nm. Maximum output energy ~5mJ; maximum repetition rate 20 HZ. Spectral resolution is 0.3 cm -1.

Introduction absorption In this experiment, measured is the absorption of laser light at 650 nm by a naphthalene buffer gas mixture that as been photolysed by UV laser pulses. absorption absorption: the technique used for measuring the absorption is ‘Cavity Ring- down Spectroscopy’ - CRDS

Introduction absorption absorption: the technique used for measuring the absorption is ‘Cavity Ring- down Spectroscopy’ - CRDS Light coupled into an optically stable cavity. Light emerging through the rear of the cavity decays exponentially, the characteristic decay time is called the ring-down time. The ring-down time depends on the reflectivity of the mirrors and the absorption in the cavity.

Introduction absorption absorption: the technique used for measuring the absorption is ‘Cavity Ring- down Spectroscopy’ - CRDS CRDS is intensity independent. It has a long effective path length. Extremely sensitive – can measure absorption coefficents of cm -1. Conventional absorption experiments can only measure absorption coefficents of cm -1. Applicable over a large spectral range.

Experiment Dye Laser Excimer Laser 1.Fill in naphthalene. 2.Fill in buffer gas. 3.Measure the absorption. 4.Photolyse the mixture. 5.Measure the absorption as a function of time. time absorption

Results 5.Measure the absorption as a function of time. time absorption Type I response Type II response Type III response Type I: Growth-decay responses The responses observed are divided into 3 types. Type II: Oscillating responses Type III: Complex responses

Type I Type I response Type II response Type III response Type I: Growth-decay responses The responses observed are divided into 3 types. Type II: Oscillating responses Type III: Complex responses Type I(a) responseType I(b) response 2 classes of Type I response

Type II Type II(b) response Type I: Growth-decay responses The responses observed are divided into 3 types. Type II: Oscillating responses Type III: Complex responses 3 classes of Type II response Type II(a) response Type II(c) response

Type III Type III(c) response Type I: Growth-decay responses The responses observed are divided into 3 types. Type II: Oscillating responses Type III: Complex responses Type III(b) response 3 classes of Type III response Most Type III responses are either (b) or (c).

Buffer Gas Pressure What determines the response Type that is observed? Buffer Gas Pressure Type I responseType II response or + Ar He Ne mbar

Questions? 1)What are we measuring? 2)Why are these responses happening?

Questions? 1)What are we measuring? 1) What are we not measuring? Not naphthalene, not buffer gas, not photolysed buffer gas No response when the photolysis pulses are unfocussed Response caused by multiphoton excitation of naphthalene buffer gas mixture

Mutiphoton excitation of 1234photon 1 photon absorption excites the molecule to the state of S 1. ~2 % of the naphthalene molecules with undergo intersystem crossing to the triplet manifold. The molecule can absorb more photons from the metastable state.

Mutiphoton excitation of 1234photons 2 photon absorption is resonance enhanced. It leaves the molecule just below the ionisation threshold. At 298 K, some of the naphthalene will begin in vibrational level of the ground state – these may be ionisted by 2 photons. The molecule can absorb more photons from the metastable state.

Mutiphoton excitation of 1234photons 3 photon absorption is again resonance enhanced and ionises the naphthalene. There is also a chance that the naphthalene ion may isomerise to the azulene ion. +

Mutiphoton excitation of 1234photons 4 or 5 photon absorption the ion may fragment. H and C 2 H 2 are the most likely fragments to be lost

Other considerations The energy dependance of some of the responses, suggests that the absorbing compound is not a direct result of photolysis. The photolysis products may react to produce the absorbing compund. Absorption may not be the mechanism for removing light from the cavity; the light may also be scattered from particles formed following photolysis. The naphthalene cation and azulene are known to absorb at this wavelength.

Questions? 2)Why are these responses happening? Is it due to a non-linear chemical reaction? Is it due to a physical process such as convection currents? ?.

Nonlinear chemical reactions Not common in the gas phase 1 st report of a chemical oscillator was by Waterford scientist Robert Boyle in late 1600s, describing a gas phase system. Feedback Fundamental to all nonlinear chemical systems is feedback. A product or intermediate must influence the rate of an earlier step. Feedback can be thermal or chemical.

Nonlinear chemical reactions Chemical system 1 No feedback. S is present in excess. Can be solved analytically Q + S A rate = k 0 A B rate = k u A + 2B 3B rate = k 1 B C rate = k 2 Type I response

Nonlinear chemical reactions Chemical system 1 Assume Q and S depend on the amount of photolysis pulses. How does the this model’s response change with the number of pulses? Q + S A rate = k 0 A B rate = k u A + 2B 3B rate = k 1 B C rate = k 2

Nonlinear chemical reactions Chemical system 1 The height of the response is proportional to the number of pulses squared. Q + S A rate = k 0 A B rate = k u A + 2B 3B rate = k 1 B C rate = k 2 The decay rate is linearly proportional to the number of pulses. Type I responses This simple chemical system may be used to model Type I responses

Nonlinear chemical reactions Chemical system 2 Cubic autocatalysis step. Can’t be solved analytically, but may be modelled. Q + S A rate = k 0 A B rate = k u A + 2B 3B rate = k 1 B C rate = k 2

Nonlinear chemical reactions Type II(a) response Type II(b) response Period increases in model. Exponential decay following oscillations No physical justification for model No mechanism for removing S Can only describe 1 component oscillations Observed responses are consistant with a nonlinear chemical system

Other Options Soot formation Periodic precipitation Convection currents Heterogeneous process ?.

Other factors Stirring the gas mixture removes oscillations. Stirring the gas mixture during photolysis changes the response. etc. Increasing the temperature at low pressure lowers the height of the response. Increasing the temperature during,or immediately after, photolysis can induce a Type II response. Same initial conditions can give rise to different responses. Changing the repetition rate of the photolysis pulse can effect the result. The height of Type I responses depend exponentially on the energy of the photolysis pulses. During photolysis the absorption increases exponentially.