Chemical Analysis with the SEM Qualitative analysis Quantitative analysis Mapping of locations of elements.

Slides:



Advertisements
Similar presentations
NUCP 2371 Radiation Measurements II
Advertisements

X-ray Detection and Analysis
Introduction to Operation of the XL-30 Scanning Electron Microscope Tutorial # 1 Overview of XL-30 Microscope Control Program.
BACKGROUND THEORY AND TERMINOLOGY FOR ELECTRON MICROSCOPY FOR CyberSTEM PRESENTATIONS.
X-Ray Astronomy Lab X-rays Why look for X-rays? –High temperatures –Atomic lines –Non-thermal processes X-ray detectors X-ray telescopes The Lab.
Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
Electron-Specimen Interactions
UWO Nanofabrication Facility and Science Studio. Facility to be hooked into Science Studio: Western Nanofabrication Facility, University of Western Ontario.
Apr 13, 2007PHYS General Physics II Applications of Quantum Mechanics.
X-ray Microanalysis An inelastic collision between a primary beam electron and an inner orbital electron results in the emission of that electron from.
Calculations of Characteristic X Ray Energies and Wavelengths and the PIXE Spectrum Physics 100 – PIXE – F06.
Spectrum Identification & Artifacts Peak Identification.
KeV HHG and Sub femtosecond K-shell excitation. ( using IR (2.1  m) Radiation Source ) Gilad Marcus The Department of Applied Physics, The Hebrew University,
Energy Dispersive X-ray Spectrometry and X-ray Microanalysis
Scanning Electron Microscope Jamie Goings. Theory Conventional microscopes use light and glass lenses SEM uses electrons and magnetic lenses to create.
Portable X-Ray Fluorescence to Determine the Composition of Household Objects Katherine Spoth, mentor Peter Revesz August 13, 2010.
Don Groom’s Course Evaluation Course evaluation question: “Is the instructor aware of the students’ limitations?” Student response: “Yes, and vice versa.”
A Pyro-Electric Crystal Particle Accelerator Chelsea L. Harris, Texas Southern University Dr. Rand Watson, Texas A&M University Cyclotron Institute Pyroelectric.
X-ray Microanalysis zThe fluorescent production of X-rays by electrons is one of the most important interactions available in the SEM because it permits.
Ge 116 Module 1: Scanning Electron Microscopy
Qualitative, quantitative analysis and “standardless” analysis NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
Surface Emissions Specimen current X-rays Cathodoluminescence Pole Piece, etc SE3  ≈ 1 nm for metals up to 10 nm for insulators.
EDAX Operation Operation of the Phoenix EDAX system
Introduction to scanning electron microscopy
BY SANTANU PRAMANIK(09369) HITESH KUMAR GUPTA(09320) CHANDAN SINGH(09260) SCANNING ELECTRON MICROSCOPE MATERIAL SCIENCE ASSIGNMENT.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Introduction to Operation of the XL- 30 Scanning Electron Microscope Tutorial # 2 Introduction to Operation and Imaging.
X-Ray Fluorescence Analysis by Gergana Hristozova Project supervisor: s. eng. M. Gustova FLNR.
X-ray Microanalysis zThe fluorescent production of X-rays by electrons is one of the most important interactions available in the SEM because it permits.
Seminar Author: Bojan Hiti Mentor: doc. dr. Matjaž Kavčič Determination of trace impurities on Si wafers with x-ray fluorescence.
Scanning Electron Microscopy
Photon detection Visible or near-visible wavelengths
Chapter 12 Atomic X-Ray Spectroscopy
Scanning Electron Microscope (SEM) – Shoots a high energy beam of electrons (waves of electrons) at a target. Electron gun Focusing coil Objective lens.
EDS Energy Dispersive Spectroscopy
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
Scanning Electron Microscope (SEM)
The Particlelike Properties of Electromagnetics Radiation Wei-Li Chen 10/27/2014.
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
Other modes associated with SEM: EBIC
Digital Imaging. Digital image - definition Image = “a two-dimensional function, f(x,y), where x and y are spatial coordinates, and the amplitude of f.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
Important EDS Parameters EDAX Detector Geometry Deadtime & Time Constants.
Scanning capacitance microscopy
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
SEM Scanning Electron Microscope
e- beam 2D sample e- beam 3D
EDAX on the XL-30 Tutorial #3 Introduction to Using the X-ray Analysis Program.
Electron probe microanalysis Low Voltage SEM Operation Modified 9/23/10.
X-ray microanalysis in the electron microscope
atomic excitation and ionisation
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Comparison b/w light and electron microscopes LIGHT MICROSCOPE ELECTRON MICROSCOPE Magnification can be done upto 2000 times Resolving power is less.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Scanning Electron Microscope Eee-Jay Rodriguez. The Structure of the Microscope Inside Outside.
(Chapter 7) CHEM–E5225 Electron microscopy
Introduction to scanning electron microscopy
Electron microprobe in Askja
X-ray spectroscopy Repetition, exercises and more
Electron probe microanalysis EPMA
Laboratory equipment Lecture (3).
NANO 230 Micro/NanoFabrication
Electron probe microanalysis EPMA
Electron probe microanalysis EPMA
Do it with electrons !.
Spectroscopy of Various Metals
DPP Shell Adjustments Short Procedure
Scanning Electron Microscopy (SEM)
Energy dispersion x-ray ( EDX) resulting as incident electron strike unexcited atoms, electrons from inner shell will be ejected and leave a hole. Electrons.
Presentation transcript:

Chemical Analysis with the SEM Qualitative analysis Quantitative analysis Mapping of locations of elements

Surface Emissions Specimen current X-rays Cathodoluminescence Photons! Pole Piece, etc SE3  ≈ 1 nm for metals up to 10 nm for insulators

…a little more accurately Shamelessly stolen from Northern Arizona University Microprobe Lab

X-ray generation from inner shell transitions SEM electron (e.g. 20 keV) “kicks out” electron from “K-shell” Emission energy is “characteristic” of energy level differences and hence element

“Kinds of X-rays” “Characteristic X-rays” –Characteristic of element from which they are emitted –Nominally sharp lines Brehmstrahlungen –Broad, featureless background –Sanity check: must asymptote to zero at Duane-Hunt limit Otherwise: evidence of charging!

X-ray spectrum of sapphire Characteristic x-rays Brehmstrahlung (baseline/background)

Fluorescence yield

– ω K = K-shell photons emitter per K-shell ionization –For each shell: ω K > ω L > ω M –For Z < 20, the yield drops like a stone! –For carbon, Z=6, ω K ≈ 0.005; for zinc, Z = 30, ω K ≈ 0.5 –Quantitation simply by looking at peak heights, or even areas, is a disaster!

Kinds of X-ray analyzers Energy dispersive (EDS) –Operate just like a solar cell! –Charge generated by one X-ray: X-ray energy divided by band gap of silicon…well, not really Wavelength dispersive (WDS) –Bent LiF crystal acts like a conventional glass lens –Degree of deviation in bent crystal depends on X-ray wavelength

X-ray detector “Energy Collection Efficiency” Glenn F. Knoll, Radiation Detection and Measurement, Wiley (1979) p. 503

X-ray detector “Energy Collection Efficiency” Glenn F Knoll, Radiation Detection and Measurement, Wiley (1979) Value increases to 3.8 eV at 77 K 77K n.b.!!

X-ray analyzer “failure modes” X-rays from heavier elements (higher energy) can ionize silicon –“Escape peaks” are at energy lower than major peaks by 1.74 keV –Some energy of incident X-ray was used to ionize silicon in detector Sum peaks –Two X-rays enter detector while counting window is open –Small peak whose energy is the sum of two lower energy peaks.

Sum peak! Aluminum at 1.48 keV Sum peak at 1.98 keV

Spatial Resolution Monte Carlo calculations presumably done for some intermediate Z element Stolen from Goldstein’s lecture K-O

Lab Lecture: How to Actually use the EDAX EDS system Main software has three tabs: Spectrum shows only the spectrum –What is a spectrum? Image –Shows SEM image of area being analyzed –Shows X-ray spectrum –Shows quantitative analysis or histogram of brightness Mapping –Allows selection of elements to be mapped –Shows spatial distribution of elements in sample

Setting up the NovaNano Be sure the CCD camera (quadrant) is deselected/not active Lower the EDS detector to 36 mm Raise the spot size to 5 or 6 In the mode setup, choose “EDX mode” Boot the Genesis software on the support computer (left monitor)

X-ray Detector Insertion Gauge

Important tabs on the Genesis window –EDS is an attachment to the SEM Both Quanta and NovaNano have EDAX systems Leo has ancient Oxford system. –Genesis is EDAX trade name for EDS operating system

Spectrum tab Image tab Mapping tab

Important icons in Genesis Import spectrum Start/Stop EDS collection Clear spectrum Expand/compress Spectrum horizontally Add text

Genesis icons continued Expand/compress scale vertically Home: Restore Horizontal and vertical scales Export to Word

Genesis icons continued

Preset options Determines “Live Time” during which data are collected What kind of time? Live? Clock? RoI? “None” is also an option

Dead time Kinds of time –Live time: time during which detector takes data –Dead time: time during which current accumulation window is closed –Clock time Sum of live and dead time Actual time we all know and love

Amp time: adjust for dead time of % 1.6 μsec – μsec

Microscope control panel and return! Return to normal operating screen

Peak ID Labels from spectrum Halographic Peak Determination: fits spectrum with theoretical sum Possible matches for energy where cursor is located Move to list of labeled peaks

Lower tray information Red while taking data Black when finished

Image Tab You’re image here!

Top Center Icons Return control to microscope! Raster Full Reduced Spot User drawn

Collect Image

Brightness and contrast adjust in counterintuitive direction Use low resolution and few strips for faster feedback.