Corneal Biomechanics, Pachymetric Progression Profile and Corneal Volume: Indices for Detecting Ectasia and Screening Refractive Candidates Renato Ambrósio.

Slides:



Advertisements
Similar presentations
Asymmetric Keratoconus Study: Novel Tomographic Parameters to enhance sensitivity to detect abnormalities in eyes with normal axial curvature maps from.
Advertisements

Juan Carlos Abad, MD Jaime Arango, MD; Camilo Tobón, MD ASCRS Poster P-225 Abad et al. Drs. Abad and Arango are consultants to Addition Technology Dr.
Biomechanical Properties of the Cornea in Normal- Tension Glaucoma Authors: Leonidas Traipe Ines Cayuqueo Fabiola Cerfogli Claudia Goya Allister Gibbons.
Familial corneal patterns in pellucid marginal degeneration: uncovering a possible etiology Hajirah N. Saeed, MD.
Statement of Commercial Interest: RDJ: None DRH: honoraria from Reichert for educational lectures on corneal biomechanics Multiple studies have shown ex.
Corneal topography orbscan
Corneal biomechanical properties and their association with intraocular pressure (IOP) and central corneal thickness (CCT) Dimitrios P. Bessinis 1, Pandelis.
Swept Source Optical Coherence Tomography for Evaluation of Posterior Corneal Changes after Refractive Surgery Dr. Tommy Chung Yan Chan Dr. Vishal Jhanji.
© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group Corneal Biomechanical Assessment using.
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group Comparative Study of Corneal Biomechanical Properties.
Application of Quantitative Method for Prospectively Identifying Risk for Ectasia After LASIK in Normal, Suspect, and Ectatic Eyes Mujtaba A. Qazi, MD.
Advances for Characterizing and Understanding the Irregular Cornea
David Zadok MD, Isaac Avni MD
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group The impact of reference body selection for calculating.
LASIK What are the Limits ?
Outcome of refractive surgery in keratoconus suspect eyes
PRK Enhancement with Mitomycin - C after LASIK - a case series
Repeatability of Anterior and Posterior Corneal Higher- Order Aberrations in 4 mm, 6 mm and 8 mm diameters measured by Pentacam System Jadwiga Wojtowicz.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. David Zadok, MD, Yakov Goldich, MD, Yaniv Barkana,
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
Dept. of Ophthalmology, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany. Outcome after big-bubble deep anterior lamellar keratoplasty.
Evaluation of Corneal Parameters and Spherical Aberration After DSAEK Measured with Pentacam System Orkun Muftuoglu, Pawan Prasher, R. Wayne Bowman, Steven.
Correlation Between Corneal Biomechanics and Wavefront Aberrations Alejandro Rivera, MD Private Practice Mexico City The author has no financial interest.
Evaluation of Zonal Equivalent Keratometry Readings After LASIK Timmy Kovoor, MD Orkun Muftuoglu, MD V.Vinod Mootha, MD Steven Verity, MD R. Wayne Bowman,
Glaucoma Screening With a New Non-Contact Air Impulse Tonometer Pandelis A. Papadopoulos,1,2, Dimitrios P. Bessinis 3, Alexandros A. Papadopoulos 1, Konstantinos.
Relationship between Pachymetry and Ocular Response Analyzer Measurements Alejandro Rivera MD.
Elias F. Jarade, MD, FICS. Corneal and Refractive Surgery Service, The Dubai Mall Medical Center, Dubai- U.A.E. Tel: ; Mob
Prospective Study of Intrastromal Corneal Ring Segments for Keratoconus Scott X. Stevens, MD Bend Ophthalmology, LLC Author has no financial interest.
Assessment of wave propagation in mice cornea and lens using phase stabilized swept source optical coherence tomography Ravi K. Manapuram, Floredes M.
World Cornea Congress VI Michael K. Smolek & Panagiotis Kompotiatis Department of Ophthalmology LSU Eye Center of Excellence, New Orleans The authors.
ROTATING SCHEIMPFLUG TOPOGRAPHIC PARAMETERS IMPORTANT IN DISTINGUISHING NORMAL FROM KERATOCONIC CORNEAL MORPHOLOGICAL FEATURES Clayton Falknor, MD, Orkun.
Khairidzan Mohd Kamal MD
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. Yakov Goldich, MD, David Zadok MD, Yaniv Barkana,
Rio de Janeiro Corneal Tomography and Biomechanics Study Group Dr. Ambrósio is consultant for Oculus Optikgeräte GmbH (Wetzlar, Germany) Agreement of Artificial.
ELEVATION AND PACHYMETRY VALUES IN NORMAL CORNEAS OBTAINED BY GALILEI ASCRS Boston April Vision Sana Research Group Vision Sana Research Group.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
A New Technique for Precise, Predictable SBK Surgery Using the B&L Zyoptix XP Microkeratome David R. Shapiro, MD Shapiro Laser Eye Center Ventura, California.
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group The study of the correlations of the optic disc size with Cornal Geometry and Biomechanical.
Rio de Janeiro Corneal Tomography and Biomechanics Study Group CORNEAL TOMOGRAPHY AND BIOMECHANICAL FINDINGS OF CONCOMITANT KERATOCONUS AND CORNEAL GUTTATA.
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group e-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group Clinical.
Evaluation of Corneal Tomography in Primary Pterygium Sahil Goel, MD (Presenting Author), Murugesan Vanathi MD *The authors have no financial interests.
Alex P. Lange The author has no financial interest to disclose.
Ahmed El-Massry, M.D. Professor of Ophthalmology - Faculty of Medicine University of Alexandria Egypt long-Term Results of Corneal Biomechanical Changes.
M. Escaf, J. Mendoza, L. Izquierdo jr., M. Henriquez Instituto de Ojos Oftalmo Salud Lima, Peru There is no financial interest in this poster.
Ocular Response Analyzer Waveform Analysis in the Ectatic Corneas: Correlation of the New Corneal Biomechanics Parameters and Severity of Keratoconus Kristin.
Familial corneal patterns in pellucid marginal degeneration: uncovering a possible etiology Hajirah N. Saeed, M.D., Amy B. Rosenfeld Ph.D., Xiaowu Gai,
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Authors: Leonidas Traipe Magdalena Rios Edison Villagra Allister Gibbons Marcelo Hidalgo Claudia Goya Authors have no financial interest.
Rio de Janeiro Corneal Tomography and Biomechanics Study Group CONCOMITANT KERATOCONUS AND FUCHS DYSTROPHY: TWO DISEASES IS BETTER THAN JUST ONE? Dr. Ambrósio.
Corneal Hysteresis Role of Corneal Biomechanics in Refractive Surgery Luis Rodriguez, MD Anny Villegas, MD Clínica de Córnea Centro Médico Docente La Trinidad.
Mathematical Description of the Ocular Response Analyzer Applanation Signal in Post-LASIK Ectasia Mujtaba A. Qazi, M.D. 1,2 David A. Luce, Ph.D. 3 Jay.
BIOMECHANICAL PROPERTIES OF THE CORNEA IN PSEUDO-EXFOLIATION SYNDROME Aylin Kılıç Ertan, MD Özgür Bilen, MD Kudret Eye Hospital, Ankara, Turkey There is.
Corneal Biomechanical Changes Following Surface Keratorefractive Surgery Teeravee Hongyok, MD, Christopher J. Rapuano, MD, Ajoy Virdi, MBBS, Elisabeth.
Evaluating Post Laser Refractive Surgery Corneal Thickness Using Artemis-2 Very High Frequency Arc-Scanning Ultrasonography Versus Pentacam * † Sharon.
CORNEAL ENDOTHELIAL PROFILE AFTER FERRARA RING IMPLANTATION Leonardo Torquetti, MD, PhD Paulo Ferrara, MD, PhD Paulo Ferrara Eye Clinic Belo Horizonte.
CORNEAL EPITHELIAL IMAGING
LSU Eye Center, New Orleans, LA
Influence of UVA-Riboflavin corneal collagen cross-linking on biomechanical properties of keratoconic eyes David Zadok MD, Yakov Goldich MD, Yaniv Barkana.
Comparison of Single-Scheimpflug and Dual-Scheimpflug Pachymetry Measurements and Effect of Decentration World Cornea Congress VI April 7-9, 2010.
LASIK vs ASA Case Studies
Mehdi Ghajarnia, MD Mark Mifflin, MD John A. Moran Eye Center
Effects of corneal collagen crosslinking on Ocular Response Analyzer waveform-derived variables in keratoconus and post-LASIK ectasia Spatial treatment.
Asociación Para Evitar La Ceguera En México
Three-Year Follow-up after LASIK in Eye with Extremely Thin Corneal Bed Hidemasa Torii, MD, Kazuno Negishi, MD, Murat Dogru, MD, Takefumi Yamaguchi, MD,
Associate Professor of Ophthalmology
Federal University of São Paulo, Brazil
Bruno Valbon, Ana Caiado, Ricardo Louzada, Renato Ambrosio Jr *.
Hyuck Jin Choi, Joo Youn Oh, Won Ryang Wee, Mee Kum Kim,
Jun Her MD. PhD, Sung-wook Kim MD, Jae-hwan Ahn MD
Retrospective Study of 4 Cases That Developed Ectasia After LASIK (Intralase flaps) with Low-Risk Based on Ectasia Risk Score System Allan Luz, MD Colin.
Presentation transcript:

Corneal Biomechanics, Pachymetric Progression Profile and Corneal Volume: Indices for Detecting Ectasia and Screening Refractive Candidates Renato Ambrósio Jr., MD, PhD Ruiz Alonso, MD; Allan Luz, MD; Daniela Jardim, MD; Marcella Salomão, MD; Simone Boghossian, MD; Bruno Fontes, MD Rio de Janeiro - Brazil

Introduction Ultrasonic Pachymetry (US-CCT) and Corneal Topography are considered the “gold standard” for screening refractive candidates Corneal Tomography (CTm) and Biomechanical Measurements provide further characterization of the cornea beyond surface maps and single point thickness Purpose To describe novel parameters, based on corneal geometry or architecture (tomography - CTm) and biomechanical properties, for diagnosing corneal ectasia and ectasia risk (susceptibility) Describe examples in which these data had enhanced the screening process for refractive candidates

Methods Pentacam exam, taking 25 rotating 360° Scheimpflug images, was used to compute Corneal Tomography (CTm) and extract architecture parameters using custom software from corneal thickness and calculated corneal volume: Thinnest Point (TP) Value & Position Corneal Thickness Spatial Profile (CTSP) Percentage of Increase of Thickness (PIT) Corneal Volume Distribution (CVD) Percentage of Increase in Volume (PIV)

“TRUE” Thinnest Point (TP) Data OD OS OD: x is positive towards nasal OS: x is positive towards temporal

Corneal Thickness Spatial Profile (CTSP) and Percentage of Increase of Thickness (PIT) Average of the thickness values along twenty-two imaginary circles centered on the thinnest point TP with increased diameters at 0,4mm-steps Percentage of increase from the thinnest point of each of the averages of twenty-two imaginary circles centered on the TP using a simple formula: (CT@x - TP) / TP (x representes the diameter of the imaginary circle)

Corneal Volume Distribution (CVD) and Percentage of Increase in Volume (PIV) Corneal volume was calculated with diameters from 1,0 to 7,0mm with 0,5mm-steps centered on the TP to create the Corneal Volume Distribution (CVD) The percentage of increase of volume from the 1,0mm volume (PIV) was calculated for each position using a simple formula: (CV @ y - CV @ 1mm) / CV @ 1mm where y represents the diameter (from 1,0 to 7,0mm) from which corneal volume was calculated

Importance of the Pachymetric Map to detect the TRUE Thinnest point 12% of normal patients have more than 10μm of difference between central & thinnest points; Correlation between Distance from central & thinnest points & Difference (r2 0.61) 34 years old patient, scheduled for LASIK (-5.75 -1.00 x 79) Normal Topography; US-CCT: 512 μm (Ave. of 5 measurements with St. Dev <3) Corneal Thickness Map (Pentacam): Thinnest Point located inferiorly to the geometrical center with 493 μm; careful regional US performed inferiorly and confirmed (495μm) Decided to change for Surface Ablation Error in determining the Thinnest Point by measuring US-CCT might be one of the most important causes of “non explained” ectasia after LASIK (when no risk factors are detected)

46 eyes with mild to moderate keratoconus and from 364 normal eyes Corneal Thickness Spatial Profile (CTSP) and Corneal Volume Distribution (CVD): Study Results 46 eyes with mild to moderate keratoconus and from 364 normal eyes Statistically significant differences were observed among the groups (p<0.05) for all positions of CTSP, CVD and for PIT. Ambrósio R Jr, Alonso RS, Luz A, Coca Velarde LG. Corneal-thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus. J Cataract Refract Surg. 2006 Nov;32(11):1851-9.

Methods Corneal biomechanical properties measurement was obtained using the ORA (Ocular Response Analyzer – Reichert) which monitors corneal response to a precise “Gaussian” air pulse, providing two variables: Corneal Hysteresis (CH = p1 – p2) Corneal Resistance Factor (CRF = p1 –[k]*p2 )

ORA Biomechanical Measurements: Study Results 82 eyes with forme fruste to moderate keratoconus and from 322 normal eyes CH and CRF are statistically lower in keratoconus than normals (p<0.05).  Mean – mmHg (+/- SD) CH CRF Keratoconus 7.81 (+/-2.25) 7.2 (+/- 2.23) Normal 10.1 (+/-1.8) 10.0 (+/- 1.9)

High “ectasia susceptibility” CTSP, PIT and CH / CRF help explain “ectasia susceptibility” in mysterious cases 28 yo with progressive ectasia after LASIK in OS (1999) with no identifiable risk factors; central flap thickness: 159 µm and residual stromal bed: 270 µm Normal Pre Op Topography MRx: -6.00 = -1.00 x 180o, 20/15 - OD -5.75 = -1.25 x 10o, 20/15 - OS US-CCT: 528µm OU Progressive Ectasia OS OD remained stable over 7 years would still be considered a good LASIK candidate based on topography and US-CCT. OD (non operated eye) Borderline CTSP and PIT & low CH (9.8) and CRF (8.1) High “ectasia susceptibility” These parameters have been critical for clinical decison for borderline LASIK candidates

Novel Parameters can also increase specificity for LASIK screening! 23 yo LASIK candidate, mild asymmetry on the axial maps Normal CTSP and PIT and above average CRF (13.1/12.2 mmHg) and CH (12.1/12.0 mmHg ) help us to decide doing LASIK, with excellent and stable results in both eyes (FU > 1year). MRx: - 9.50 -1.75 x 3º OD – 20/60 - 7.25 -1.25 x 179º OS – 20/20 US-CCT: 565 / 545 µm (OD / OS) OD OS Pre Op. ORA normal OU OD UCVA: 20/50 OS UCVA: 20/20 Pre Op. CTSP and PIT OD / OS Dif. Axial Maps OD / OS