Gas-based tracking for SuperBelle Beam background Upgrade plan Summary Shoji Uno (KEK) April, 20-22, 2005 2 nd Joint Super B factory WS in Hawaii.

Slides:



Advertisements
Similar presentations
The Belle Silicon Vertex Detector T. Tsuboyama (KEK) 6 Dec Workshop New Hadrons with Various Flavors 6-7 Dec Nagoya Univ.
Advertisements

Beam-plug and shielding studies related to HCAL and M2 Robert Paluch, Burkhard Schmidt November 25,
Background issues in the KEKB
Super-B Factory Workshop April 20-23, 2005 Super-B IR design M. Sullivan 1 Status on an IR Design for a Super-B Factory M. Sullivan for the Super-B Factory.
Drift chamber for super-Belle Present performance and background Idea for upgrade Upgrade plan Summary Shoji Uno (KEK) Jan-20 th, 2003 at Super B-factory.
Current BG Status at Belle Osamu Tajima ( Tohoku univ ) Assumption in this talk 100days-operation / yr 1nTorr CO pressure in simulation HER / LER = 1.1.
Total Current Draw of CDC Total CDC current(8400 wires) has kept about 1mA at the maximum beam current for each years. Vacuum condition is improving from.
June 2-4, 2004 DOE HEP Program Review 1 M. Sullivan for the PEP-II Team DOE High Energy Physics Program Review June 2-4, 2004 PEP-II Status and Plans.
Striplet option of Super Belle Silicon Vertex Detector Talk at Joint Super B factory workshop, Honolulu 20 April 2005 T.Tsuboyama.
Super-B Factory Workshop January 19-22, 2004 Super-B IR design M. Sullivan 1 Interaction Region Design for a Super-B Factory M. Sullivan for the Super-B.
1 Optics and IR design for SuperKEKB Y.Ohnishi 1/19-22, 2004 Super B Factory Workshop in Hawaii.
BES III Main Drift Chamber MDC group Yuanbo Chen June 5,2002, Beijing.
1 EMCal design MICE collaboration meeting Fermilab Rikard Sandström.
Drift Chambers Drift Chambers are MWPCs where the time it takes for the ions to reach the sense wire is recorded. This time info gives position info:
SuperKEKB to search for new sources of flavor mixing and CP violation - Introduction - Introduction - Motivation for L= Motivation for L=
Operational Experience with machine backgrounds at KEKB 23 September 2003 T.Tsuboyama (KEK)
Report of the NTPC Test Experiment in 2007Sep and Others Yohei Nakatsugawa.
PERFORMANCE OF THE MACRO LIMITED STREAMER TUBES IN DRIFT MODE FOR MEASUREMENTS OF MUON ENERGY - Use of the MACRO limited streamer tubes in drift mode -Use.
Jornadas LIP 2008 – Pedro Ramalhete. 17 m hadron absorber vertex region 8 MWPCs 4 trigger hodoscopes toroidal magnet dipole magnet hadron absorber targets.
MdcPatRec Tracking Status Zhang Yao, Zhang Xueyao Shandong University.
Super Belle CDC Basic design Electronics  Test of pre-amplifier chips Wire stringing method Schedule Shoji Uno (KEK) Dec-12 th, 2008.
Muon Detector Jiawen ZHANG Introduction The Detector Choices Simulation The structure and detector design The Expected performance Schedule.
NanoPHYS’12 – December 17-19, 2012 K. Nakano, S. Miyasaka, K. Nagai and S. Obata (Department of Physics, Tokyo Institute of Technology) Drift Chambers.
1 Flux concentrator for SuperKEKB Kamitani Takuya IWLC October.20.
Impact parameter resolution study for ILC detector Tomoaki Fujikawa (Tohoku university) ACFA Workshop in Taipei Nov
Super-Belle Vertexing Talk at Super B Factory Workshop Jan T. Tsuboyama (KEK) Super B factory Vertex group Please visit
Muon-raying the ATLAS Detector
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
PID for super Belle (design consideration) K. Inami (Nagoya-u) - Barrel (TOP counter) - Possible configuration - Geometry - Endcap (Aerogel RICH) - Photo.
Experimental and Numerical studies on Bulk Micromegas SINP group in RD51 Applied Nuclear Physics Division Saha Institute of Nuclear Physics Kolkata, West.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
CDC S. Uno KEK Endplate Design sBelle 250mm 300mm 350mm.
Luca Spogli Università Roma Tre & INFN Roma Tre
9 September 2004The Straw Tube Chamber1 The CDC Curtis A. Meyer Carnegie Mellon University Physics Requirements and Specifications Prototype Construction.
26 June 2006Imaging2006, Stockholm, Niels Tuning 1/18 Tracking with the LHCb Spectrometer Detector Performance and Track Reconstruction Niels Tuning (Outer.
ILC MDI workshop January 6-8, 2004 PEP-II IR M. Sullivan 1 Interaction Region of PEP-II M. Sullivan for the ILC MDI workshop January 6-8, 2005.
Impact parameter resolutions for ILC detector Tomoaki Fujikawa (Tohoku university) ACFA Workshop in Taipei Nov
PERFORMANCE OF THE PHENIX SOUTH MUON ARM Kenneth F. Read Oak Ridge National Lab & University of Tennessee for the PHENIX Collaboration Quark Matter 2002.
The Q Weak Experiment Event tracking, luminosity monitors, and backgrounds John Leacock Virginia Tech on behalf of the Q Weak collaboration Hall C Users.
03/21/2005Michael Spitznagel (MIT)Page 1 The Babar Drift Chamber Michael Spitznagel Massachusetts Institute of Technology.
1 What I did last year Nick Barlow Manchester Christmas meeting January 2005.
Tracking in a TPC D. Karlen / U. Victoria & TRIUMF for the LCTPC collaboration.
1 CDC Readout - upgrade for Higher Luminosity - Y.Sakai (KEK) 29-Oct-2002 TRG/DAQ Review of Status/Plan (based on materials from S.Uno/M.Tanaka)
The Detector Performance Study for the Barrel Section of the ATLAS Semiconductor Tracker (SCT) with Cosmic Rays Yoshikazu Nagai (Univ. of Tsukuba) For.
CGEM-IT project and beam test program G. Felici for the FE-LNF-TO team Partially supported by the Italian Ministry of Foreign Affairs under the Program.
The BoNuS Detector: A Radial Time Projection Chamber for tracking Spectator Protons Howard Fenker, Jefferson Lab This work was partially supported by DOE.
CDC Upgrade Beam background Simulation study Idea for upgrade Upgrade plan Summary Shoji Uno (KEK) Mar-20 th, 2008.
DØ Beauty Physics in Run II Rick Jesik Imperial College BEACH 2002 V International Conference on Hyperons, Charm and Beauty Hadrons Vancouver, BC, June.
First results from SND at VEPP-2000 S. Serednyakov On behalf of SND group VIII International Workshop on e + e - Collisions from Phi to Psi, PHIPSI11,
CDC Baseline design  Chamber radius  Wire configuration  Main parameters  Electronics Summary Shoji Uno (KEK) July-4 th, 2008.
P.F.Ermolov SVD-2 status and experimental program VHMP 16 April 2005 SVD-2 status and experimental program 1.SVD history 2.SVD-2 setup 3.Experiment characteristics.
Tracking software of the BESIII drift chamber Linghui WU For the BESIII MDC software group.
The CDF Upgrade - Incandela -CERN - January 26, 2001 slide 1 96 wire planes –(8 superlayers) –50% are 3 o stereo –Uniform drift (0.88 cm cell) –30,240.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
1 Preliminary Considerations on Tracking for HIEPA Yifei Zhang and Jianbei Liu University of Science and Technology of China Workshop on Physics at Future.
Precision Drift Tube Detectors for High Counting Rates O. Kortner, H. Kroha, F. Legger, R. Richter Max-Planck-Institut für Physik, Munich, Germany A. Engl,
E+/e- Backgrounds at BEPCII/BESIII JIN Dapeng Aug. 22, 2011.
Status of BESIII and upgrade of BESIII
IOP HEPP Conference Upgrading the CMS Tracker for SLHC Mark Pesaresi Imperial College, London.
Tracking results from Au+Au test Beam
Future Plan of the Neutral Kaon Spectrometer 2 (NKS2) Experiment
Pixel-strip-EMC tracker and DC option
Status of the TOF Detector
CDC Structure S. Uno KEK
RPC and LST at High Luminosity
Performance of MDC during New Data Taking
Interaction Region Design Options e+e- Factories Workshop
GEANT Simulations and Track Reconstruction
CDC structure Shoji Uno (KEK)    July-8, 2009.
IR/MDI requirements for the EIC
Presentation transcript:

Gas-based tracking for SuperBelle Beam background Upgrade plan Summary Shoji Uno (KEK) April, 20-22, nd Joint Super B factory WS in Hawaii

Wire chamber Wire chamber is a good device for the central tracker.  Less material  Good momentum resolution.  Cheap  It is easy to cover a large region.  Established technology  Easy construction.  Many layers  Provide trigger signals and particle ID information. Wire chamber can survive at Super-KEKB. Our answer does not change after the last WS in  The beam background became smaller even for higher beam current and higher luminosity.  We recognize the luminosity term is small, clearly.

CDC Total Current Maximum current is still below 1.2mA, even for higher stored current and higher luminosity. Vacuum condition is still improving.  Thanks KEKB people for hard work.  I hope there is still room to improve vacuum condition further.

Hit rate 10KHz Apr.-5 th,2005 I HER = 1.24A I LER = 1.7A L peak = 1.5x10 34 cm -2 sec -1 I CDC = 1mA Main Inner Small cell

Luminosity Dependences CDC BG did not change! Feb, 2004 Inner most Middle Outer

Hit rate at layer 35 I HER = 4.1A Hit rate = 13kHz I LER = 9.4A Hit rate = 70kHz Dec., 2003 : ~5kHz Now : ~4kHz Dec.,2003 In total 83kHz HER LER

Simulation Study for Higher Beam Background Detail was reported in the last WS by K.Senyo. MC +BGx1MC+BGx20

Tracking eff. with B     decays With 600ns dead time and under x20 occupancy, CDC keeps about 90% of the single tracking efficiency including geometrical acceptance. (thus the tracking itself has almost 100% eff.) Occupancy Overlay(times) B->  reconstruction eff. including geometrical acceptance Square root of recon. eff. of the left ~ single track efficiency of mid/high p

About 80% of efficiency is kept in the slow  efficiency under x20 occupancy. Reconstruction using SVD information is necessary to recover the loss of efficiency. Slow p efficiency from B  D*(Dp slow )p recon. eff. of the slow pion ~ single track efficiency of slow p B  D*  reconstruction eff. including geometrical acceptance

Occupancy Luminosity cm -2 sec -1 No. of channel N Total Readout time window (  sec) Q>0Q>50 N Hit Belle Babar ~700 ~350 Occ. = N Hit /N Total (%) Occ./Time window (%/  sec) Max. drift time (  sec) Occ./Time x Max. Drift time (%) Normalized by Lum.(%) Belle Babar ~ x20 Bkgd in Belle CDC ~ x3 Bkgd in Babar DCH Random trigger

at HL6 in KEK

Idea for upgrade In order to reduce occupancy,  Smaller cell size A new small cell drift chamber was constructed and installed. It has been working, well.  Faster drift velocity One candidate : 100% CH 4  Results show worse spatial resolution due to a large Lorentz angle.  A beam test was carried out under 1.5T magnetic field. So far, no other good candidate.

XT Curve & Max. Drift Time Small cell(5.4mm) Normal cell(17.3mm)

Baseline design CDC SVD

Main parameters Present Future Radius of inner boundary (mm) Radius of outer boundary (mm) Radius of inner most sense wire (mm) Radius of outer most sense wire (mm) Number of layers 5058 Number of total sense wires Effective radius for dE/dx measurement (mm) Gas He-C 2 H 6 Diameter of sense wire (  m) 30

Wire configuration 9 super-layers : 5 axial + 4 stereo(2U+2V)  A 160*8, U 160*6, A 192*6, V 224*6,  A 256*6, U 288*6, A 320*6, V 352*6, A 388*8 Number of layers : 58 Number of total sense wires : Number of total wires : ~60000

Deformation of endplate Number of wires increase by factor 2.  Larger deformation of endplate is expected.  It may cause troubles in a wire stringing process and other occasions. Number of holes increases, but a chamber radius also enlarges. Cell size is changing as a function of radius to reduce number of wires.  The fraction of holes respect to total area is not so different, as comparing with the present CDC. 11.7% for present CDC 12.6% for Super-Belle CDC In order to reduce deformation of endplates,  The endplate with a different shape is considered.  Wire tension of field wires will be reduced. Anyway, we can arrange the wire configuration and can make a thin aluminum endplate.

Better background Higher luminosity is not always higher beam background.  KEKB Luminosity > PEPII Luminosity  Belle background < Babar background Now, we(KEKB-Belle+PEPII-Babar) are discussing a future machine. New machine should be designed to reduce the beam background based on our knowledge. We should make effort to get better background condition in the future machine using present both machines and both detectors.

Smaller background in Babar CDC Only ~0.3% occupancy for LER particle background. Brian Petersen’s talk in HL6 Total LER Belle Babar Occupancy normalized by readout time window(%)

Best condition Small SR background (PEPII HER) + Small HER particle background (KEKB HER) + Small LER particle background (PEPII LER) + Small Luminosity term (KEKB) + Movable masks (KEKB) Small pixel or striplet (New) + Larger SVD (Babar SVT) + Larger gas-based CDC (Belle CDC) + FADC readout (Babar CDC) + Good reconstruction software (Babar?) + Lower B field?

Summary Our conclusion does not change from the previous WS in the last year.  Background became better even for higher stored current and higher luminosity.  We recognize the luminosity term is small, clearly. New CDC  Smaller cell size for inner most layers.  Larger outer radius Better performance is expected. Or lower magnetic field.

Radiation Damage Test a: ’93 Plastic tube d: ’94 SUS tube b: ’93 Plastic tube + O2 filter e: ’94 SUS tube + O 2 filter c: ’94 Plastic tube f: ’94 Plastic tube Total accumulated charge on sense wire(C/cm) Gain degradation

Momentum Resolution Thanks for filling He based gas and using Aluminum field wires. The resolution was calculated using cosmic ray events during a normal physics run. BaBar data was obtained from a talk in Vancouver WS.

Momentum Resolution We could obtain a small constant term using He- based gas and aluminum field wires. Slop parameter is not so good as compared with expected value.  We had to change the electronics parameters to reduce the cross talk.  HV is slightly lower than the original value.  Alignment is not perfect.  More tuning to reject bad points.  Some effects from the beam background. Transverse Momentum(GeV/c)

dE/dx Resolution Good resolution was obtained. It is useful to identify hadrons and electrons. BhabhaMu pair M.I.P in Hadronic events 0.35<P<0.88GeV/c without any PID. Electron

dE/dx Measurement MQT chip (Charge to Time conversion) and multi-hit TDC. 80% truncated mean. Relativistic rise.  1.4 for electron. Good PID performance for lower momentum region. dE/dx information helps to separate high momentum K/ . log 10 P(GeV/c)

Comparison with Babar Momemtum resolution(SVD+CDC)  Pt /Pt = 0.19Pt  0.30/  [%] : Belle  Pt /Pt = 0.13Pt [%] : BaBar Mass(dE) resolution  Mass resolution for inclusive J/       9.6 MeV(Belle) vs 12.3 MeV(BaBar)  dE resolution for B 0  D   +, D   K +     13.8MeV(Belle) vs 19.0MeV(BaBar) We could obtain better resolution than BaBar.  BaBar has a CFRP support cylinder with 2mm thickness between SVD and CDC. Tracking efficiency for low momemtum particles is worse than BaBar.  D *+ D *   yield(slow  eff.) ~0.5(?) x BaBar  3 layers SVD (Belle) vs 5 layers SVD(BaBar) Energy loss measurement  5.6%(Belle) vs 7%(Babar) for Bhabar events

Pulse height variation 2000 Summe r 2001 Summer 2002 Summer Summer 2004 Summer Change of bias voltage for preamp Installation of small cell chamber Replacing with new S/QT for layer 0 & 1 Hokuue

Hit rate 10kHz Apr.-5 th, 2005 I HER = 1.24A I LER = 1.7A L peak = 1.5x10 34 I CDC = 1mA Main Inner Small cell

Small Cell Drift Chamber

Photo of small cell chamber Installation in 2003 summerJust after wire stringing

Curved Endplate Deformation of endplate due to wire tension was calculated at design stage of present Belle CDC. Deformation(mm) Present New

Expected performance Occupancy  Hit rate : ~140kHz  ~7Hz X 20  Maximum drift time : nsec  Occupancy : 1-4%  140kHz X nsec = Momemtum resolution(SVD+CDC)  Pt /Pt = 0.19Pt  0.30/  [%] : Conservative  Pt /Pt = 0.11Pt  0.30/  [%] : Possible  0.19*(863/1118) 2 Energy loss measurement  6.9% : Conservative  6.4% : Possible  6.9*(752/869) 1/2

Movable Masks 16 masks in HER and 16 masks in LER.  8 horizontal + 8 vertical for each rings. Location  4(H)+4(V) at D6 and 4(H)+4(V) at D3 for LER  4(H)+4(V) at D9 and 4(H)+4(V) at D12 for HER D3 D6 D9 D12

Effectiveness Usually, the horizontal masks are not effective. Because the horizontal tail is not so large. A few vertical masks are quite effective to reduce the beam background in the both cases for storage and injection and also for LER and HER.  By factor two or more. KEKB had movable masks near IR, which were not so effective to reduce the beam background.  Those masks in both of LER and HER were removed.