1 Research on Erratic Dark Currents in pCVD Diamonds Diamonds are Forever Adam Edwards, Stanford University M. Bruinsma (UC Irvine), P. Burchat (Stanford),

Slides:



Advertisements
Similar presentations
Status of test beam data analysis … with emphasis on resistive coating studies Progress and questions 1Meeting at CEA Saclay, 25 Jan 2010Jörg Wotschack,
Advertisements

Full of Energy.
Electromagnetic Induction r1.04. The Snapshot button is used to capture the screen. The Journal is where snapshots are stored and viewed. The.
Field Emission Measurements with CERN DC-Spark System Tomoko MURANAKA Hebrew University / CERN.
Aging, High Rate and Shielding L. Lopes Lip-Coimbra.
Slide 1 Irradiation Study of Single Crystal Diamond Sensors for the PLT Irradiation of sensors at the PS 1.5 years ago Comparison to RD42 irradiated poly.
DIAMOND ACTIVITIES DESY Zeuthen Wolfgang Lange. MOTIVATION and PEOPLE: Calorimetry in an environment with high radiation doses (TESLA beam cal) Beam diagnostics.
Instrumentation: ground and noise Temperature Measurement.
RD42 Meeting, CERN W. de Boer, Univ. of Karlsruhe 1 CVD diamonds as beam monitors CVD diamond used for: heavy ion beam monitor beam exit window.
Passivation of Carbon Nanotube Chips for Biosensing Applications By: Vince Nguyen Faculty Mentor: Dr. Phillip Collins Lab Mentor: Dr. Jaan Mannik IMSURE.
Measurements on single and poly crystal diamond samples at CERN Luis Fernandez-Hernando Christoph Ilgner Alick Macpherson Alexander Oh Terry Pritchard.
Investigation of the properties of diamond radiation detectors
Bias Ring Current Carl Goodrich 2/26/08. Carl Goodrich- VELO Meeting2 Sensor: Measurement: IV Data from December V bias Ground.
Test of Pixel Sensors for the CMS experiment Amitava Roy Purdue University.
UCSB Encapsulation Studies UC Santa Barbara Based upon a 6 week study by F. Garberson in collaboration with A. Affolder, J. Incandela, S. Kyre and many.
HL-LHC Standards and Best Practices Workshop (11-13 June 2014)
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
Induction and Inductance Chapter 30 Magnetic Flux.
Generating Currents Consider the following circuit: a bar moves on two rails that are connected at one end. The whole setup has a magnetic field that goes.
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Test of Silicon Photomultipliers (SiPM) at Liquid Nitrogen Temperature Yura Efremenko, Vince Cianciolo nEDM CalTech Meeting 02/14/2007.
Background Issues: Real Time Radiation Measurement S.M.Yang EPC.IHEP Mini-Workshop on BEPCII Background Study March 2008 Institute of High Energy.
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Electric Current.
Chapter 22 Magnetism and Its Uses.
Day 59 End of Topic 7! Starting Topic 8.. What’s Due and When: HW Turn In: Next Class, ◦ HW: Titled Day 54, Day 57, Day 59. ◦ So the HW is due Formal.
3rd NoRDHia 1 TITLE INVESTIGATION OF A SINGLE CRYSTAL DIAMOND SENSOR AND ITS APPLICATION IN BACKGROUND MEASUREMENTS FOR HERA Wolfgang Lange,
Magnetic Induction April 1, 2005 Happenings Short Quiz Today New Topic: Magnetic Induction (Chapter 30) Quiz NEXT Friday Exam #3 – April 15 th. Should.
ALBA Synchrotron – 17 June 2010 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona First Measurements on 3D Strips Detectors.
Transmission Lines No. 1  Seattle Pacific University Transmission Lines Kevin Bolding Electrical Engineering Seattle Pacific University.
Contacting single bundles of carbon nanotubes with alternating electric fields Marcella De Carlo Danilo Zampetti.
P. Riedler- GGT Meeting 3/4/20061 Status of Sensor Irradiation and Bump Bonding P. Riedler, G. Stefanini P. Dalpiaz, M. Fiorini, F. Petrucci.
Diamond Sensor Diamond Sensor for Particle Detection Maria Hempel Beam Impact Meeting Geneva,
Analysis of Edge and Surface TCTs for Irradiated 3D Silicon Strip Detectors Graeme Stewart a, R. Bates a, C. Corral b, M. Fantoba b, G. Kramberger c, G.
PNPI R&D on based detector for MUCH central part (supported by INTAS ) E. Chernyshova, V.Evseev, V. Ivanov, A. Khanzadeev, B. Komkov, L.
Solar tracker system.
TCT measurements with SCP slim edge strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko.
Paul Dolejschi Progress of Interstrip Measurements on DSSDs SVD.
Investigation of CVD Diamonds as Sensor Material for BeamCal Alexandr Ignatenko FCAL Collaboration Meeting, Orsay October 6-7, 2007.
Chapter 6 Overview. Maxwell’s Equations In this chapter, we will examine Faraday’s and Ampère’s laws.
Annealing of CCE in HPK strip detectors irradiated with pions and neutrons Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko.
SP & DC-DC Considering the benefits of combining serial powering and DC-DC conversion technologies in powering ATLAS SCT upgrade modules & staves Richard.
Vacuum Studies of LHCb Vertex Locator Sensors Gwenaëlle Lefeuvre, Ray Mountain, Marina Artuso Department of Physics, Syracuse University Abstract : The.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
Carbon Nanotube Device Fabrication John Gerling EE 235 Introduction to Nanofabrication
TCAD Simulation – Semiconductor Technology Computer-Aided Design (TCAD) tool ENEXSS 5.5, developed by SELETE in Japan Device simulation part: HyDeLEOS.
Paul Dolejschi Characterisation of DSSD interstrip parameters BELLE II SVD-PXD Meeting.
FBK 3D CMS pixel sensors preliminary lab measurements E. Alagoz 1, A. Krzywda 1, D. Bortoletto 1, I. Shipsey 1, G. Bolla 1, and G. F. Dalla Betta 2, M.
Simulation of new P-Type strip detectors 17th RD50 Workshop, CERN, Geneva 1/15 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona.
1 Single event upset test of the voltage limiter for the ATLAS Semiconductor tracker TSL Experiment Number: F151 distance between power supplies and modules.
Day 54 End of Topic 7! Starting Topic 8.. Time for it to be in HW Turn In: ◦ HW: Titled Day 53, Day 49, Day 48. ◦ Lets do it The Lab: For about 4 minutes,
Infrared Laser Test System Silicon Diode Testing 29 May 2007 Fadmar Osmić Contents: Setup modifications new amplifier (Agilent MSA-0886) new pulse generator.
The Different Types of Inductors and Their Affecting Factors
 An electron passes perpendicularly through a magnetic field at a velocity of 2.0x10 7 m/s. The strength of the magnetic field is 0.25 T. What is the.
R&D on Hadron Blind detector, recent results Issues addressed: - gain limits in CF 4 with heavily ionizing particles - operation.
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
Solid-State Cameras for LHC instrumentation
Belle-II VXD radiation monitoring and beam abort with sCVD diamond sensors Lorenzo Vitale, Belle-II SVD collaboration INFN and Univ. Trieste, ITALY Requirements.
IBL Overview Darren Leung ~ 8/15/2013 ~ UW B305.
Induced Voltages and Inductance
SuperB SVT Silicon Sensor Requirements
大強度
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Damage under UCSB bias bonds
Electromagnetic Induction
Passitivation Location
Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA M. Palm, CERN.
T-489: Induced Activity and Residual Dose Rates
Measurements of Stability of Gas Electron Multiplier (GEM)
Diamond Measurements in Zeuthen
Presentation transcript:

1 Research on Erratic Dark Currents in pCVD Diamonds Diamonds are Forever Adam Edwards, Stanford University M. Bruinsma (UC Irvine), P. Burchat (Stanford), H. Kagan (OSU), R. Kass (OSU), D. Kirkby (UC Irvine), B.A. Petersen (Stanford) RD42 Meeting, CERN May 14, 2004

2 Introduction n In February 2003, the 1.5T magnetic field was temporarily lost and erratic dark currents in two diamonds were observed.

3 Experimental Questions n Some of the questions that we have been trying to answer about these erratic dark currents u Are these surface/edge currents? u Is it an effect of the metalization? u Is it a property of the whole diamond or a localized effect? u Is this common to pCVD diamonds? u Are these currents caused by radiation? u How do they depend on bias voltage? u How does a magnetic field change them?

4 Reproducing These Effects n Erratic currents have been seen with every diamond sensor setup. n Erratic currents are always eliminated by a 1.5T magnetic field perpendicular to the electric field. Example: Diamond “UT31” with solder connections, kapton packaging, guard ring and CrAu metalization. Example: Diamond “UT31” placed in 1.5T

5 Reproducing These Effects n We’ve worked with various setups. u Different metalizations u Different metalization geometries, including guard rings u Different packaging, using wire bonds and soldering u Different DC readout electronics n These erratic dark currents are real and reproducible in the lab.

6 Laboratory Tests n We have recently used four new pCVD diamond sensors made with G10 packaging and wire bonding. u Two sensors have one pad and two have 4 pads u Two sensors have AuCr metalization and two have AuCr/Al u All sensors have a guard ring n CCD measured ~200μm u Exposed to 1kRad from 90 Sr for CCD measurement, then heat treated at 400°C n Irradiation tests performed with a ~11kRad/H on contact 60 Co source

7 Diamond Sensor Operation n Both with and without radiation and with no applied magnetic field, all four diamonds were operated at 100V without seeing any onset of erratic currents. No radiation or magnetic field Bias switched from 500V to 100V Radiation in Rad/Hour No magnetic field

8 High Voltage Stability Before Irradiation n Biased at +500V u One pad with 100pA  4000pA F (after 13 days with no erratic dark currents) u Two pads with ~100pA u 9 other pads and two guard rings showed no erratic dark currents n Biased at -500V u Two with ~200pA u One with ~20pA No magnet field Erratic currents arise in different pads independently

9 60 Co Irradiation Test n Signal currents become obscured by the onset of erratic currents. n Erratic currents appear in each sensor pad independently Rads per Hour of Exposure No magnet field

10 60 Co Irradiation Test n Sensors exposed to ~2kRad/Hour form 60 Co (~140kRad in total) n Within minutes there are erratic currents seen n Some currents are an order of magnitude higher than expected from the amount of radiation. n Every biased sensor in irradiation has some erratic current. No magnet field

11 Effects of 60 Co Irradiation with 500V Bias, B=0 n Before Irradiation n After Irradiation Note the different current scales!

12 Effects of 60 Co Irradiation Tests Without a Bias Voltage n One diamond sensor had no voltage bias during the irradiation and had no subsequent increase of erratic dark currents. n A later irradiation of this sensor with a bias voltage created subsequent erratic dark currents of 250pA-15000pA. No magnet field

13 Lowering the Bias Voltage n We have found the lowering the bias voltage can reduce the amount of erratic dark currents. n No diamond sensors see any erratic currents at a 100V bias. n The voltage where the erratic currents go away is unique to each pad. n It takes ~hours before erratic currents return at higher voltage. No magnet field

14 Magnetic Field Test n All four sensors were placed in a 1.5T magnetic field with the same orientation as the diamond sensors inside BaBar n Over 5 orders of magnitude, all pads with erratic dark currents showed that they could be stopped by the magnetic field.

15 Conclusions n We have reproduced, in the lab, the erratic dark currents and magnetic field effects that are seen in BaBar. n Guard rings show that the erratic dark currents are not surface currents. n The erratic dark currents have been seen with 3 different kinds of metalization. n Erratic dark currents are localized, affecting each pad differently. n Every pCVD diamond that we have tested has had erratic dark currents. n These currents arise under high bias voltage and increase during irradiation at high voltage. n Erratic dark currents are not present at low bias voltages. n Erratic dark currents are not present at 1.5T magnetic fields.