EPFL, Design and first Prototype for a B eam P ipe D istance M onitoring Safety Switch
EPFL, Requirements : Reliability of the system „Fail-safe“ system Simple principle of operation As little as possible additional material As a careful touching of the beam pipe is permitted....
EPFL, Beam Pipe Distance Monitoring both during installation and data taking Top- and Bottom Boxes Side Boxes Minimum distance : 7 mm !!
EPFL, First switch activated at 7 mm distance from the beam pipe signal Second switch activated at 6.5 mm distance from the beam pipe alarm Three switches under & at the front of the detector box Three switches on top & at the front of the detector box One switch at the side of the detector box Each switch consists Of two mettalic blades, Allowing a distance- Dependent signal
EPFL, Metall blade („finger strip“) : Thickness 500 microns Beryllium Copper Switching precision < mm Foil around the beam pipe : Thickness 100 microns Copper
EPFL, Safety Switch for side boxes Metallic foil Stesalite piece & non magnetic blade [Design model]
EPFL, Safety switch for top (and bottom) boxes Metallic foil Stesalite piece & non magnetic blade [Design model]
EPFL, Next steps... Furhter tests with different finger strips Detailed studies on electrical connection possibilities Studies on optimal fixation points (on the detector boxes)