6 November 2007Cal-Ops Meeting Mallorca Recent Results from EPIC MOS Life Test Facility Tony Abbey and Craig Brown University of Leicester Space Research.

Slides:



Advertisements
Similar presentations
EPIC Calibration Meeting, Mallorca Low energy calibration with the Vela SNR K. Dennerl, 2009 March 31 Low energy calibration with the Vela SNR Mallorca,
Advertisements

Clusters as calibration tools S. Molendi (IASF-MI)
X-ray Imaging Spectrometers (XIS) of Astro-E2 Hironori Matsumoto (Kyoto University) and the XIS team 1. Overview Astro-E2 is the fifth Japanese X-ray Astronomy.
XMM EPIC MOS Andy Read EPIC Calibration Meeting Mallorca, Spain 01/02/05 What can we do with Pattern 31s? - Central pixel (red) has.
Electrical transport and charge detection in nanoscale phosphorus-in-silicon islands Fay Hudson, Andrew Ferguson, Victor Chan, Changyi Yang, David Jamieson,
Chandra X-Ray Observatory CXC Paul Plucinsky EPIC Cal April ACIS Calibration: Recent Updates, Planned Updates, & Future Issues 2.E0102: Joint.
XMM Calibration/Ops Meeting Mallorca October Using 3X3 Binned Mode for MOS Cameras for Fast(er) Imaging Tony Abbey, Leicester University.
Characterization of primed state of CVD diamond by light and alpha particles C. Manfredotti Experimental Physics Department University of Torino INFN-
CHARGE COUPLING TRUE CDS PIXEL PROCESSING True CDS CMOS pixel noise data 2.8 e- CMOS photon transfer.
XMM 1 EPIC MOS Monitoring CAL/OPS Meeting MPE
RHESSI/GOES Observations of the Non-flaring Sun from 2002 to J. McTiernan SSL/UCB.
XMM-Newton 1 Michael Smith, ESAC PN Monitoring Palermo, April 2007.
Measuring the Temperature of Hot Solar Flare Plasma with RHESSI Amir Caspi 1,2, Sam Krucker 2, Robert P. Lin 1,2 1 Department of Physics, University of.
European Space Astronomy Centre Villafranca del Castillo, Madrid, Spain Andy Pollock XMM-Newton SOC RGS calibration Calibration of the XMM-Newton RGS Andy.
EPIC MOS Life Test Facility The centre of the central CCD in the MOS cameras is showing damage – Andy Read et al. This damage causes low energy redistribution.
MOS 3x3 mode slow slew survey Richard Saxton October 2006.
XMM EPIC MOS Steve Sembay EPIC Calibration Meeting Tuebingen 03/02/03-06/02/03 MOS Cooling Results and Current Response Both MOS Cameras.
Mallorca EPIC Cal Meeting - February 2005 Darren Baskill: XMM project: MOS monitoring.
SDW20051 Vincent Lapeyrère LESIA – Observatoire de Paris Calibration of flight model CCDs for CoRoT mission.
XMM EPIC MOS Andy Read for the BGWG CAL/OPS/BG Meeting Palermo, Sicily 11-13/04/07 EPIC Background Working Group Summary: Meeting.
Chandra X-Ray Observatory CXC Paul Plucinsky EPIC Cal Nov ACIS Calibration: Planned Updates & Future Issues 2.ACIS Operations: Controlling the.
An XMM-ESAS Update Steve Snowden NASA/Goddard Space Flight Center EPIC Operations and Calibration Meeting - BGWG Palermo - 11 March 2007.
Deterministic Modeling of the MOS Background Steve Snowden NASA/Goddard Space Flight Center EPIC Operations and Calibration Meeting Mallorca 1-3 February.
Tony Abbey XMM Cal/Ops meeting – MPE, Garching – 5 May 2006 Tony Abbey – University of Leicester Reducing MOS data rate.
XMM EPIC MOS Andy Read EPIC CAL/OPS Meeting Vilspa, Spain 23-24/03/04 XRT Point Spread Function - Conclusion of spectral and spatial.
XMM Calibration/Ops Meeting Mallorca 1-3 Feb MOS2 CCD2 & CCD5 noise problems Tony Abbey, Leicester University.
XMM EPIC MOS Andy Read EPIC CAL/OPS Meeting MPE, Germany 04-05/05/06 XRT Point Spread Function - Shifts in PSF position with energy.
Calibration Meeting Tubingen Feb 2003 MOS Cameras pre and post cooling comparison Tony Abbey, Leicester University Comparison between two closed.
XMM 1 EPIC MOS Monitoring CAL/OPS Meeting Mallorca
Column rejection in the MOS  The core of soft sources is removed by the standard emchain.  Due to very large fluctuations in count rate from one column.
XMM EPIC MOS Steve Sembay Mallorca 02/02/05 Temporal and spatial variability of the MOS RMF 1.Introduction and brief history of the.
XMM EPIC MOS Andy Read EPIC CAL/OPS Meeting MPE, Germany 04-05/05/06 EPIC BGWG XMM-Newton EPIC BackGround Working Group founded (~1.
RGS/MOS-cooling Results February 03, 2003 L. Metcalfe 1 Science Operations & Data Systems Division Research & Scientific Support Department Page 1 XMM-Newton.
Chandra X-Ray Observatory CXC Paul Plucinsky EPIC Cal Update on ACIS Calibration 1) Update to the ACIS contamination model 2) Temperature-dependent.
Can people meet from 2:40 to 3:30 on Tuesday, September 5?
EPIC Calibration Meeting, Madrid Correcting spatial inhomogeneities of the absolute energy scale K. Dennerl, 2010 March 23 Correcting spatial inhomogeneities.
EPIC Calibration Meeting, Mallorca Origin of gain offsets K. Dennerl, 2008 April 8 Origin of gain offsets: new insights from eROSITA calibration Mallorca,
1/23/ Proton Radiation Damage in High- Resistivity n-Type Silicon CCDs C. Bebek, D. Groom, S. Holland, A. Karcher, W. Kolbe, J. Lee, M. Levi, N.
1 TIPS 2011 May Persistence in the WFC3 IR detector Knox S. Long.
Bulk Silicon CCDs, Point Spread Functions, and Photon Transfer Curves: CCD Testing Activities at ESO Mark Downing, Dietrich Baade, Sebastian Deiries, (ESO/Instrumentation.
Summary of Lesser Packaged SNAP CCDs to Date. Lesser Packaged CCDs (UASN5071) (UASN5450) (UASN5451) (UASN5452)
NASSP Masters 5003F - Computational Astronomy Lecture 19 EPIC background Event lists and selection The RGA Calibration quantities Exposure calculations.
CCDs in space: the effects of radiation on Hubble’s Advanced Camera for Surveys (ACS) Max Mutchler, David Golimowski (Space Telescope Science Institute),
1 Components of Optical Instruments Lecture Silicon Diode Transducers A semiconductor material like silicon can be doped by an element of group.
M. Bruzzi et al. Thermal donors in MCz Si, Trento Meeting Rd50 February 28, 2005 Mara Bruzzi, D. Menichelli, M. Scaringella INFN Florence, University of.
Telescope Guiding with a HyViSI H2RG Used in Guide Mode Lance Simms Detectors for Astronomy /2/09.
A multi-colour survey of NGC253 with XMM-Newton Robin Barnard, Lindsey Shaw Greening & Ulrich Kolb The Open University.
Gamma-Ray Bursts observed with INTEGRAL and XMM- Newton Sinead McGlynn School of Physics University College Dublin.
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
1 Investigation into properties of neutron and electron irradiated CCD By Nick Sinev University of Oregon Jim Brau, Jan Strube, Olya Igonkina, Nick Sinev.
Development of CCDs for the SXI We have developed 2 different types of CCDs for the SXI in parallel.. *Advantage =>They are successfully employed for current.
TIPS - Oct 13, 2005 M. Sirianni Temperature change for ACS CCDs: initial study on scientific performance M. Sirianni, T. Wheeler, C.Cox, M. Mutchler, A.
NICMOS Calibration Challenges in the Ultra Deep Field Rodger Thompson Steward Observatory University of Arizona.
SPIE Astronomical Instrumentation June 26, 2008 Physics of reverse annealing in high- resistivity ACIS Chandra CCDs Catherine E. Grant (MIT) Bev LaMarr,
` Background photo courtesy of NOAO. Taken with LBNL p-channel CCD with extended red sensitivity. Pixel Area Variation in CCDs and Implications for Precision.
The Slow Slew Survey Richard Saxton / Pedro Rodriguez November 2006.
3 May 2007 Suzaku Users mwb MIT/MKI XIS Update Mark Bautz, MIT Kavli Institute XIS-2 Anomaly Contamination.
MPI Semiconductor Laboratory, The XEUS Instrument Working Group, PNSensor The X-ray Evolving-Universe Spectroscopy (XEUS) mission is under study by the.
MAXI - Monitor of All-sky X-ray Image Performance of the engineering model of the MAXI/SSC Katayama H. a, Tomida H. a, Matsuoka M. a, Tsunemi H. a,b, Miyata.
Night OH in the Mesosphere of Venus and Earth Christopher Parkinson Dept. Atmospheric, Oceanic, and Space Sciences University of Michigan F. Mills, M.
Application of a Charge Transfer Model to Space Telescope Data Paul Bristow Dec’03
N.Kimmel, the MPI Halbleiterlabor team and PNSensor References: H. Tsunemi et al., NIM A 421 (1999), H. Tsunemi et al., NIM A 436 (1999), Characterization.
Radiation damage studies in LGAD detectors from recent CNM and FBK run
Development of the Soft X-ray Large solid angle Camera onboard WF-MAXI
Relative Spectral Response and Flat Fields with Internal Calibration Lamps Luisa M. Lara IAA-CSIC Granada (SPAIN)
CCD Image Processing …okay, I’ve got a bunch of .fits files, now what?
Trap Pumping Method Importance of inter-phase trapping
Temporal &Spatial Dependency of the MOS RMF
Matthew Rose - Emission Spectra of Bicron Scintillators
Matthew Rose - Emission Spectra of Bicron Scintillators
Presentation transcript:

6 November 2007Cal-Ops Meeting Mallorca Recent Results from EPIC MOS Life Test Facility Tony Abbey and Craig Brown University of Leicester Space Research Centre Cal Ops Meeting, Mallorca 6 Nov 2007

6 November 2007Cal-Ops Meeting Mallorca The XMM-Newton Life Test: What is it? Launched 10/12/99, nominal mission of 2 years, extended to 31/03/10 Solid state focal plane - CCD22 developed by E2V for UoL for EPIC Over the course of the mission, an unexpected degradation of the EPIC camera has occurred Central CCD, matching the centre of the PSF, shows significant degradation compared to other parts of the EPIC CCDs Early spectra taken show less energy redistribution than later spectra of the same object in the sky Damage must be from X-rays, so not bulk damage Aims of the test are to: Re-create this type of damage in the lab Establish a mechanism for the damage Try and reverse the damage

6 November 2007Cal-Ops Meeting Mallorca In Orbit X-ray Dose – Andy Read _ The flux on the central CCD of MOS1 – for imaging modes only - from SSC files. This is a lower limit, and doesn’t include timing mode – perhaps 30% more. Similar numbers for MOS2. The energy redistribution was being noticed in the focal “patch” after a few 100 revs – ie at 3 or 4 E11 eV..

6 November 2007Cal-Ops Meeting Mallorca Improving and calibrating the test CCD: Uneven dark current at -100°C and removed after annealing at +100°C. Now barely visible.

6 November 2007Cal-Ops Meeting Mallorca XMM-Newton Life Test: What we are doing The XMM-Newton Life Test: What we are doing 2.5cm

6 November 2007Cal-Ops Meeting Mallorca The damage starts It was decided to keep to as close to the in-orbit characteristics as possible Hence the CCD was kept cooled to -100°C and read out continually while the beam was on (remember we reduced to -130°C later) We could therefore see that the whole of the field of the CCD was saturated with charge After 28 hours of irradiation at 5kV 4mA – which was supposed to be equivalent to around 3% of the total, we decided to take a spectrum at low energy. We were not expecting to see any change yet……however… This irradiation was miscalulated, giving each pixel of the central focussed spot 3% of the combined dose of all the in-orbit x-rays on a MOS camera. This mistake gave us plenty of opportunity for annealing experiments.

6 November 2007Cal-Ops Meeting Mallorca Cu-L X-rays at -100°C after 3% of the run In addition to the dark area below the main focussed damage, there are large groups of columns where the x-rays are smeared out, indicating severe CTE problems

6 November 2007Cal-Ops Meeting Mallorca Dark Frame at -50°C after 3% of the run Left image shows image on warming up to -50 after the irradiation, and the right hand image shows cooling down to -50 after a 13 hour room temperature anneal

6 November 2007Cal-Ops Meeting Mallorca The XMM-Newton Life Test: Desperate Measures Annealing for 3.5 days at +100°C and 11.5 days at +130°C (during the last Palermo meeting) 1 day of UV annealing with an EPROM eraser Compensate for a flat-band shifts by tweaks to clock and substrate voltage and increase row transfer time from 1 to 10us per clock phase …CCD performance was greatly recovered and, in addition, the low energy response was improved beyond pre- irradiation levels! Craig developed an analytical technique for showing the ratio of the gaussian fitted peaks in different damage areas Peak Height Ratios Nitrogen line with some C-k contamination

6 November 2007Cal-Ops Meeting Mallorca The XMM-Newton Life Test: Ghost Image Surprisingly, the intensity of the x-ray ghost image was largely unaffected by the annealing, but the dark current on the RHS was reduced. The second image shows the developing “hole” after UV annealing due to flat band shifts, and the improvement to this of voltage/clock width change is evident on the third image.

6 November 2007Cal-Ops Meeting Mallorca The XMM-Newton Life Test: Copper-L Image After the UV annealing the smeared columns (poor CTE) had concentrated down the centre of the CCD. The dramatic improvement of the change from 1 to 10us row transfer clock can be seen here.

6 November 2007Cal-Ops Meeting Mallorca The XMM-Newton Life Test: Carbon - k Images After the UV annealing and the improvement of the change from 1 to 10us row transfer clock, we could now see Carbon X-rays. The left image shows single pixel events with some residual damage in the central area where the beam was strongest. However by using 1-4 pixel events, the dark columns are not evident, showing that there is just a little charge trailing in these columns. In both images the uneven response is due to the x-ray beam, not the CCD.

6 November 2007Cal-Ops Meeting Mallorca On the way – examine the store section response at 700eV, and try to damage it No significant change in spectra or dark current could be observed for 80% of the full XMM dose at the silicon with 1.2KV anode voltage – probably needs a higher energy to cause damage – TBD.

6 November 2007Cal-Ops Meeting Mallorca The XMM-Newton Life Test: Irradiation of image section in the undamaged upper left corner ? This has proceeded slowly over the last 2 months, using an X-ray source voltage of 1.5kV which seems to be too low to cause damage

6 November 2007Cal-Ops Meeting Mallorca Conclusions so far… The enhanced dark current ghost image caused by an overdose of focussed x- rays has not been fully annealed out Thermal and UV annealing combined with clock level and timing changes has restored CTE over the whole of the CCD Energy redistribution effects are subtle The store section has an almost perfect single gaussian energy response, but significant QE only for energy at 700eV and above. This response is undamaged by the full XMM dose of approx 1keV x-rays at the silicon – need higher energy data to show that the electrode structure prevents redistribution effects. A significant fraction of the XMM dose in the image section of 1.2keV x-rays also produces little damage, and no dark current effects. We are comparing the results so far obtained with those described by Janesick et al for back illuminated devices – indeed it appears that the open implant region behaves exactly like the early back illuminated devices studied by Janesick.

6 November 2007Cal-Ops Meeting Mallorca Future work Increase the energy of the x-rays to be more compatible with the EPIC spectrum Repeat the corner irradiation Perform the same on a second CCD22 Perform the same on a CCD66 having the newly developed thin electrode structure