.

Slides:



Advertisements
Similar presentations
Hit esc to quit hit any key to continue A New Forensics Technique to Investigate the Presence of Chemical FingerPrints in Human Breath.
Advertisements

Gas Chromatography Introduction 1.) Gas Chromatography
Lecture 8b Gas Chromatography.
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
The Foundations: Classical Split and Splitless Injection
© 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies.
Analysis of Residues. Laboratory Analysis of Debris and Other Samples 1. Preparation of Liquid Samples: Liquid samples are simply drawn into a special.
Gas Chromatography in the detection of Volatile Organic Compounds.
Biodegradation of btex
I n t e g r i t y - S e r v i c e - E x c e l l e n c e Headquarters U.S. Air Force 1 Direct Sampling Ion Trap Mass Spectrometry Rob R. Smith Oak Ridge.
Supercritical Fluid Chromatography and Extraction
4135 Bluebonnet Dr. Stafford, TX
Multiphase Extraction for Soil and Groundwater Remediation Nick Swiger Spring 2007.
1 Soil Vapor Extraction Limitations and Enhancements LeeAnn Racz AgE 558 Semester Project April 2001.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Gas Chromatography 
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Partitioning of Volatile Organic Carbon Compoundss.
Methods Monitoring Polar Compounds Using Membrane Extraction and High-Speed Gas Chromatography Authors: Jonathan Maurer, Dr. Anthony J. Borgerding* Department.
.
Monitoring the desorption of analytes from nonpolar SPME fibers using high speed gas chromatography Authors: Kimberly Jasch, Tony Borgerding* Department.
Partitioning of VOCs: Why do we care? ä Determines how best to treat a site ä vapor extraction ä pump and treat ä remove contaminated soil ä Determines.
Introduction to Gas Chromatography Written by Bette Kreuz Produced by Ruth Dusenbery University of Michigan-Dearborn 2000.
Gas chromatography is used in many research labs, industrial labs (quality control), forensic (arson and drug analysis, toxicology, etc.), environmental.
LECTURE 4: CHROMATOGRAPHY Content: - Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas.
CHROMATOGRAPHY.
Chapter 6 - Chromatography
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
Industrial Air Quality Monitoring. Sampling Protocols Grab vs. Integrated Personal vs. Area.
Chapter 27 Gas Chromatography 1. Principles
Chromatography Chapter 6.
Magnet Analytical Chemistry Unit 4
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
PAS-Intro1 Dated 24th Aug Copyright © Siemens AG 1999 All Rights Reserved Siemens Advanced Engineering Pte Ltd Process Analytical Services Division.
PORTABLE HIGH-SPEED GAS CHROMATOGRAPH
Decontamination of filed equipment used in environmental site characterization and ground-water monitoring projects University of Arkansas 11/13/2006 By.
animation.php.
Field Analytical Methods. Considerations for Field Analytical Methods Which parameters are anticipated to occur at the site? What media will be analyzed?
Application of solid-phase microextraction to the recovery of explosives and ignitable liquid residues from forensic specimens K.G. Furton, J.R. Almirall,
Gas Chromatography Lecture 38.
© 2006 MSA VaporLab™ 700 Gas Analyzer. © 2006 MSA Product Description  Rack mount, turn-key gas analyzer  Analyzes a complex matrix for trace quantities.
By: Arafath and Nick. What is it  Chromatography is a technique that is used to separate the substances present in a mixture.  It is widely used to.
Analytical Separations
HPLC – High Performance Liquid Chromatography
Solutions: AP Notes Use Pre-AP Notes for background solution info Colligative Properties.
Chapter 29 Supercritical Fluid Chromatography and Extraction.
1 Setting Action Levels and Controlling exposure with Air Monitoring A review...
Chapter 23 An Introduction to Analytical Separations.
1/16/2016The GC-in-a-PC 1 Pneumatic Focusing Gas Chromatography PFGC Robert O’Brien, Portland State Univ. & VOC Technologies The GC-in-a-PC Development.
Solution Equilibrium and Factors Affecting Solubility
Electronic Sensor Technology, Inc. Preventing Air, Water & Soil Pollution with zNose®
Chapter 1: The Nature of Analytical Chemistry
Experiments in Analytical Chemistry
Gas Chromatography Chap 27 Types: Gas-solid chromatography (GSC)
CHAPTER 6 Gases and Vapors. Learning Objectives Describe the various properties of the chemicals that are most important to the practice of industrial.
ArsonAnalysis of Fire Arson is defined as purposely setting fire to a house, building or other property. Arson is the second leading cause of death by.
Fire Debris Fire debris is submitted to laboratories for analysis by the fire marshal, crime scene investigators, forensic scientists, and insurance investigators.
Organic Chemistry Lab 315 Fall, 2016.
Chromatography- TLC & HPLC
Fire Debris Fire debris is submitted to laboratories for analysis by the fire marshal, crime scene investigators, forensic scientists, and insurance investigators.
Automation of Sample Preparation for Trace Analysis Haibin Wan
PORTABLE HIGH-SPEED GAS CHROMATOGRAPH
Fire Debris Fire debris is submitted to laboratories for analysis by the fire marshal, crime scene investigators, forensic scientists, and insurance investigators.
Gas Chromatography.
Supercritical Fluid Chromatography and Extraction
Deyuan Kong, Brian Morlan, Roopa Kamath, and Sara Mcmillen
VAPOUR PHASE CHROMATOGRAPHY
Chromatography Daheeya Alenazi.
Gas Chromatography.
CHAPTER 6 Gases and Vapors.
GAS CHROMATOGRAPHY.
Presentation transcript:

Overview ä Gas Chromatograph calibration ä Syringe Technique ä VOC exposure limit ä Site Assessment ä Potential sites ä Soil Gas Surveys ä Field Analysis ä Gas Chromatograph calibration ä Syringe Technique ä VOC exposure limit ä Site Assessment ä Potential sites ä Soil Gas Surveys ä Field Analysis

Gas Chromatograph injection volume ä Output ä chromatogram ä converted to peak areas and peak times ä Convert peak area to mass using injection of known mass (standard) ä peak area is proportional to mass injected ä mass injected can be converted to concentration given _________ _________ ä Alternately use peak area (PA) as surrogate for mass ä Output ä chromatogram ä converted to peak areas and peak times ä Convert peak area to mass using injection of known mass (standard) ä peak area is proportional to mass injected ä mass injected can be converted to concentration given _________ _________ ä Alternately use peak area (PA) as surrogate for mass (If a calibrated mass isn’t required)

Gas Chromatograph Calibration ä We can use the headspace sample from source vials to calibrate the GC. ä We will use the ideal gas law and the vapor pressure of the VOCs. ä We can use the headspace sample from source vials to calibrate the GC. ä We will use the ideal gas law and the vapor pressure of the VOCs. liquid gas Octane Acetone Toluene vapor pressure at 25 °C vapor pressure at 25 °C 1.88 kPa 24 kPa 3.8 kPa MW g g g density 0.71 g/mL 0.79 g/mL 0.87 g/mL

Example Calibration: Octane Calculate moles, mass, and equivalent liquid volume of 100 µL headspace sample at 25 °C. liquid octane gas moles mass volume Table

VOC Contaminated Site Map ä Report gas concentrations in mg/m 3. ä Example: Given a peak area of 1 x 10 4 from an injection volume of 100 µL, calculate the concentration in mg/m 3. Assume the peak area from the source vial injections was 2 x ä Report gas concentrations in mg/m 3. ä Example: Given a peak area of 1 x 10 4 from an injection volume of 100 µL, calculate the concentration in mg/m 3. Assume the peak area from the source vial injections was 2 x sample PA calibration PA sample volume mass injected for calibration

Syringe Technique ä The Problem: ä VOC vapors sorb to glass barrel, Teflon plunger, and stainless steel needle ä The Solution: ä Remove GC needle. ä Purge syringe 10 times with room air to remove any residual VOCs. ä Put on sample needle. (continued) ä The Problem: ä VOC vapors sorb to glass barrel, Teflon plunger, and stainless steel needle ä The Solution: ä Remove GC needle. ä Purge syringe 10 times with room air to remove any residual VOCs. ä Put on sample needle. (continued)

Syringe Technique: solution ä Insert into sample bottle (with syringe at zero volume). ä Fill syringe fully with gas and purge syringe contents back into the source bottle (repeat 3 times). ä Fill syringe and adjust to 100 µL. ä Close syringe valve and remove syringe from sample vial and remove sample needle. ä Put on GC needle. ä Instruct GC to measure sample. ä Insert needle in injection port, open syringe valve, inject sample, hit enter button all as quickly as possible. ä Remove syringe from the GC injection port. ä Insert into sample bottle (with syringe at zero volume). ä Fill syringe fully with gas and purge syringe contents back into the source bottle (repeat 3 times). ä Fill syringe and adjust to 100 µL. ä Close syringe valve and remove syringe from sample vial and remove sample needle. ä Put on GC needle. ä Instruct GC to measure sample. ä Insert needle in injection port, open syringe valve, inject sample, hit enter button all as quickly as possible. ä Remove syringe from the GC injection port. Equilibrate with headspace Eliminate needle carryover

Octane Exposure Limits ä OSHA PEL (Permissible exposure level) ä 500 ppm TWA (approximately ____ mg/m 3 ) ä LC50 ä CAS# : Inhalation, rat: LC50 =118 g/m 3 /4H. ä OSHA PEL (Permissible exposure level) ä 500 ppm TWA (approximately ____ mg/m 3 ) ä LC50 ä CAS# : Inhalation, rat: LC50 =118 g/m 3 /4H. concentration in octane source vial 500 (1 m 3 of air is approximately 1 kg)

Site Assessment ä Contaminated soil, a global problem ä Difficult to assess subsurface contamination ä can’t see it ä 3-d problem ä even with lots of monitoring wells can miss important subsurface features. ä Expensive to decontaminate sites ä competing national priorities ä highest priority needs to be prevention ä Contaminated soil, a global problem ä Difficult to assess subsurface contamination ä can’t see it ä 3-d problem ä even with lots of monitoring wells can miss important subsurface features. ä Expensive to decontaminate sites ä competing national priorities ä highest priority needs to be prevention

Hazardous Waste Site Surveys ä loading zones ä hydraulically operated lifts ä accidental spills ä storage tanks ä vegetative distress ä herbicide application ä hazardous materials ä stained soil ä loading zones ä hydraulically operated lifts ä accidental spills ä storage tanks ä vegetative distress ä herbicide application ä hazardous materials ä stained soil äfill material äused to hide evidence of spill ämay contain hazardous substances äwater and sewer lines äprovide pathways for migration of subsurface contaminants

Soil Gas Survey ä Effective screening technique for mapping the extent of VOCs ä Indicates location of contaminant sources ä Effective screening technique for mapping the extent of VOCs ä Indicates location of contaminant sources Advantages rapid low cost minimal disturbance to site no waste generated adaptable to site conditions Advantages rapid low cost minimal disturbance to site no waste generated adaptable to site conditions Disadvantages detection limits may be too high some compounds may not be detected field results are semi-quantitative Disadvantages detection limits may be too high some compounds may not be detected field results are semi-quantitative Sampling Matrix Soil Gas Survey

Soil Gas Survey: Methods ä Place hollow, small diameter probe in soil ä Apply vacuum to probe ä Extract soil pore gas ä Take a sample of soil pore gas using: ä syringe - on-site gas chromatograph analysis ä Tedlar bag - on-site or off-site analysis ä unaffected by most compounds ä impermeable to gas exchange ä stainless steel adsorption tube - quantitative laboratory analysis ä Place hollow, small diameter probe in soil ä Apply vacuum to probe ä Extract soil pore gas ä Take a sample of soil pore gas using: ä syringe - on-site gas chromatograph analysis ä Tedlar bag - on-site or off-site analysis ä unaffected by most compounds ä impermeable to gas exchange ä stainless steel adsorption tube - quantitative laboratory analysis

Soil Gas Sampling ä Static sampling can be done two ways: ä An in-situ adsorbent (usually an activated charcoal rod) is buried in the soil for a period of days to weeks. The adsorbent is retrieved and analyzed at a laboratory for VOCs. ä Samples are collected from containers placed in the surface soil and analyzed using portable analytical instruments. ä Concentrations in soil gas are affected by dissolution, adsorption, and partitioning. ä Partitioning refers to the ratio of component found in a saturated vapor above an aqueous solution to the amount in the solution. ä Contaminants can also be adsorbed onto inorganic soil components ä or "dissolved" in organic soil components. ä Static sampling can be done two ways: ä An in-situ adsorbent (usually an activated charcoal rod) is buried in the soil for a period of days to weeks. The adsorbent is retrieved and analyzed at a laboratory for VOCs. ä Samples are collected from containers placed in the surface soil and analyzed using portable analytical instruments. ä Concentrations in soil gas are affected by dissolution, adsorption, and partitioning. ä Partitioning refers to the ratio of component found in a saturated vapor above an aqueous solution to the amount in the solution. ä Contaminants can also be adsorbed onto inorganic soil components ä or "dissolved" in organic soil components.

Field Analysis ä Less accurate and less sensitive than laboratory analysis! ä Immediate results ä Examples ä Portable Gas chromatograph ä Photoionization Air Monitor ä Flame Ionization Detector ä Test kits ä Less accurate and less sensitive than laboratory analysis! ä Immediate results ä Examples ä Portable Gas chromatograph ä Photoionization Air Monitor ä Flame Ionization Detector ä Test kits Analysis Matrix

Portable Gas Chromatograph ä Portable GC contains ä a built-in 3-column configuration with isothermal oven which provides optimized fast GC analysis for up to 40 volatile organic compounds (VOC). ä a miniaturized PID/ECD dual detection system which allows monitoring at 1-10 PPB levels of a wide range of aromatic, chloroalkene, and chloroalkane solvents. ä Portable GC contains ä a built-in 3-column configuration with isothermal oven which provides optimized fast GC analysis for up to 40 volatile organic compounds (VOC). ä a miniaturized PID/ECD dual detection system which allows monitoring at 1-10 PPB levels of a wide range of aromatic, chloroalkene, and chloroalkane solvents.

Photoionization Air Monitor ä The 2020 hand-held Total VOC air analyzer weighs just 1.75 lb. (0.79 kg). ä Sample is drawn via the internal pump ä Results are displayed on the built- in LCD. ä The operating concentration range is PPM. ä The 2020 hand-held Total VOC air analyzer weighs just 1.75 lb. (0.79 kg). ä Sample is drawn via the internal pump ä Results are displayed on the built- in LCD. ä The operating concentration range is PPM.

Flame Ionization Detector ä The Micro FID weighs 8.1 lb. (3.7 kg.), ä the smallest and lightest datalogging Flame Ionization Detector (FID) available. ä The concentration range is ,000 PPM with a response time of less than 3 seconds. ä The Micro FID weighs 8.1 lb. (3.7 kg.), ä the smallest and lightest datalogging Flame Ionization Detector (FID) available. ä The concentration range is ,000 PPM with a response time of less than 3 seconds.

Potential Sites ä Underground fuel storage tanks ä home owner beware! ä gasoline stations ä Waste management facilities ä Chemical storage facilities ä Liquid waste lagoons ä Injection wells ä Chemical transfer facilities ä Underground fuel storage tanks ä home owner beware! ä gasoline stations ä Waste management facilities ä Chemical storage facilities ä Liquid waste lagoons ä Injection wells ä Chemical transfer facilities

Underground Storage Tanks ä Leaking underground storage tanks are a significant source of soil and water contamination in the United States. ä New regulations went into effect in 1998 ä Many facilities removed underground tanks and replaced them with double walled tanks or above ground tanks for petroleum product and chemical storage. ä Leaking underground storage tanks are a significant source of soil and water contamination in the United States. ä New regulations went into effect in 1998 ä Many facilities removed underground tanks and replaced them with double walled tanks or above ground tanks for petroleum product and chemical storage.