Introduction to Fluorescence Microscopy. Introduction to fluorescence microscopy Fluorescence Widefield Fluorescence microscopes Filters and Dichroics.

Slides:



Advertisements
Similar presentations
Chapter 4 Companion site for Light and Video Microscopy Author: Wayne.
Advertisements

Fluorescence and Confocal Microscopy
Electron Optics Basic Introduction Bob Ashley
Slide 1 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories BMS “Introduction to Confocal Microscopy and Image Analysis” Purdue.
Light Chapter
IMMUNODEPLETION OF CONDENSIN FROM XENOPUS EGG EXTRACTS HSSΔcond.Δmockmock boiled beadsextracts cond. anti- cond. anti- α-tub Smc2 
Electron Optics.
Microscopy Lecture I.
ERT107 MICROBIOLOGY FOR BIOPROCESS ENGINEERING Pn Syazni Zainul Kamal PPK Bioprocess.
1. Resolution (R) : separation of close objects, light wavelength NA, numerical aperture 2. Contrast : distinction of objects from background “light field”
Microscope Objective Parameters. What do the Numbers on the Objective Mean ?
Blizard Advanced Light Microscopy club Making friends with your microscope.
© J.Paul Robinson, Purdue University BMS 631 – LECTURE00007.PPT BMS LECTURE 7 Flow Cytometry: Theory Optics - Filter Properties & manipulation.
Optical Microscopy Lecture 1.
Fluorescence microscopy – Principle and practical consideration Hiro Ohkura.
Optics. Thomas Young ( ) Wave Optics Diffraction & Interference Christiaan Huygens ( )
Geometrical Optics and Basic Imaging Light Paths of the Bright Field Microscope E. D. Salmon University of North Carolina at Chapel Hill.
Practical Aspects See: 1) anatomy/anatomy.htmlhttp://micro.magnet.fsu.edu/primer/ anatomy/anatomy.html 2)
Fiber Optics Defining Characteristics: Numerical Aperture Spectral Transmission Diameter.
USE AND CARE OF THE MICROSCOPE LECTURE 1. MICROSCOPY u Light Microscopy: any microscope that uses visible light to observe specimens u Compound Light.
Lecture 1 The Principles of Microscopy
 J.Paul Robinson - Purdue University Cytometry Laboratories Slide 1 t:/classes/BMS524/524lect1.ppt BMS “Introduction to Confocal Microscopy.
MICROSCOPES Light (visible) Fluorescent U-V Electron Monocular
Chapter 25: Interference and Diffraction
Microscopy Techniques for Biomaterial Characterization: A Primer Prabhas V. Moghe Lecture 3 September 21, 1999 RU CBE 533 or BME 553; NJIT BME 698.
Slide 1 t:/classes/BMS524/2002 lectures/524lect2.ppt © J. Paul Robinson - Purdue University Cytometry Laboratories BMS “Introduction to.
Study of Protein Association by Fluorescence-based Methods Kristin Michalski UWM RET Intern In association with Professor Vali Raicu.
9.12 Diffraction grating • Order of diffraction
Introduction to Microscopy. Objectives Learn to use a compound microscope correctly. Diagram the path of light through a compound microscope. Name major.
Microscope.
A microscope is a Complicated Lens n The microscope can be represented by a single convex lens.
 J.Paul Robinson - Purdue University Cytometry Laboratories Slide 1 t:/classes/BMS524/524lect1.ppt 8:44 PM BMS “Introduction to Confocal.
Practical aspects of fluorescence microscopy
Microscopy.
Illumination and Filters Foundations of Microscopy Series Amanda Combs Advanced Instrumentation and Physics.
Analytical Tools Microscopy Chapter 4 ©2010 Elsevier, Inc.
TIRF Total Internal Reflection Fluorescence Microscopy specialized fluorescence microscopy technique specifically images a very thin optical section (50-250nm)
Microscopy. Scale Lenses and the Bending of Light light is refracted (bent) when passing from one medium to another refractive index –a measure of how.
Tools of the Laboratory: The Microscope
3.18. Defects caused by reflections We have assumed that the paraxial approximation applies in that all rays make small angles with respect to the optical.
Background Research. material selection for launching of telescope; must be soft, able to absorb vibration, fit within the appropriate temperature range.
Geometrical Optics Chapter 24 + Other Tidbits 1. On and on and on …  This is a short week.  Schedule follows  So far, no room available for problem.
Quantitative Imaging Using imaging to analyze molecular events in living cells Ann Cowan.
BIO 224 Intro to Molecular and Cell Biology. Microscopes are tools frequently used in cell biology Type of microscope used depends on the specimen being.
Epi-illumination is form of Kohler Illumination:
Focal plane of lens full field microscope, magnification defined by image distance/object distance scanning microscope, magnification defined by display.
Slide 1 t:/classes/BMS524/524lect2.ppt © J.Paul Robinson - Purdue University Cytometry Laboratories Lecture 2 The Principles of Microscopy BMS.
Molecular Cell Biology Light Microscopy in Cell Biology Cooper Modified from a 2010 lecture by Richard McIntosh, University of Colorado.
Lecture 26-1 Lens Equation ( < 0 )  True for thin lens and paraxial rays.  magnification m = h’/h = - q/p.
The Nature of Light. Light Can Act Like Waves or In 1801 Thomas Young an English scientist did an experiment. –Double slit experiment Passed a beam of.
Optics: Total Internal Reflection
An instrument for magnifying very small objects
Principles and Practices of Light Microscopy II: Brightfield optics, resolution, and aberrations.
Designing a Microscopy Experiment Kurt Thorn, PhD Director, Image from Susanne Rafelski, Marshall lab.
(Image: T. Wittman, Scripps) Introduction to Light Microscopy.
(Image: T. Wittman, Scripps) Introduction to Light Microscopy.
Microscopy Dr. Bhavesh Patel Principal V.P. and R.P.T.P. Science College Vallabh Vidyanagar –
Microscopy.
Microscopy Group 2 Cabatit, Mendoza, Ramos, Rodriguez, Tan.
Fluorescence and Fluorochromes Peter O’Toole Tel:
Light Microscope Terms and Practices.
Microscope.
Lasers and Confocal.
BMS 632 – Lecture 6 – Optical Filters & light manipulation
BMS “Introduction to Confocal Microscopy and Image Analysis”
Types of Microscopes Light Electron Bright field Dark-field Scanning
LIGHT MICROSCOPY basic
Types of Microscopes Light Electron Bright field Dark-field Scanning
FLUORESCENCE MICROSCOPY
Microscopy.
Presentation transcript:

Introduction to Fluorescence Microscopy

Introduction to fluorescence microscopy Fluorescence Widefield Fluorescence microscopes Filters and Dichroics Objectives and abberation CCD cameras

Natural Fluorescence

Transmittance is subtractive while fluorescence is additive

excitation emission Fluorescence Microscopy: basics of theory Absorbance spectrum limits excitation. Energy states limit excitation Molecule returns to lowest vibrational state emitting heat Light is emitted on return to ground state

Fluorescence spectra correlated to sise of conjugated ring

Multichannel fluorescence labelling Direct coupling to macromolecules Fluorescent dyes and substrates Fluorescent fusion proteins Fluorescent Antibodies Ch2(Red) Texas Red anti-rabbit & Rabbit anti-  Gal Ch1(Green) UBI-GFP Arterial edothelial cell Ch1(Green) FITC Tubulin Ch2(Red) mitotracker Ch3(Blue) DAPI Ch1 Ch2

Light path of a Epi-fluorescent Microscope fluoromicroanatomy.html

Upright Scope Brightfield Source Epi- illumination Source Image from Nikon promotional materials

Inverted Microscope Brightfield Source Epi- illumination Source Image from Nikon promotional materials

Microscope for widefield epifluorescence Mercury Lamp Dichroic Reflector Objective Sample Stage DIC analyser Dichroic Reflector CCD camera

Mercury lamp spectra

Standard Band Pass Filters Transmitted LightWhite Light Source 625/50 nm BandPass Filter Texas Red nm Light

Standard Long Pass Filters Transmitted Light Light Source 500 nm Long Pass Filter >520 nm Light Transmitted Light Light Source 575 nm Short Pass Filter <575 nm Light Standard Short Pass Filters

Optical Filters Dichroic Filter/Mirror at 45 deg Reflected light Transmitted LightLight Source 510 LP dichroic Mirror

GFP Longpass Emission Set D425/60x 470DCXR E480LP

Dichroic for multi-colour samples The excitation (red/oarnge) and emission (blue) spectra for three common fluors (Alexa 488, 555 and 633) Requires a dichroic mirror with three bands of reflection and intervening windows of transmission

Dielectric filter components “glue” Interference in Thin Films Small amounts of incident light are reflected at the interface between two material of different RI Thickness of the material will alter the constructive or destructive interference patterns - increasing or decreasing certain wavelengths Optical filters can thus be created that “interfere” with the normal transmission of light

Microscope for widefield epifluorescence Mercury Lamp Dichroic Reflector Objective Sample Stage DIC analyser Dichroic Reflector CCD camera

The objective determines the content of your image! The objective is critical to the efficiency of light collection (your signal) And determines the accuracy of the image (inaccuracy is called aberration). The objective determines resolution.

Objective markings PLAN-APO-40X 1.30 N.A. Oil 160/0.22 Flat field Apochromat Magnification Numerical Tube Coverglass Factor coloured rings Aperture Length Thickness  - Infinity corrected Immersion medium Oil (black ring) Water (W) Air (white ring)

A  NA=n(sin  ) Light cone (n=refractive index) Resolving power is directly related to numerical aperture. The higher the NA the greater the resolution Resolving power: The ability of an objective to resolve two distinct lines very close together NA = n sin  –  is 1/2 the angular aperture of the objective Numerical Aperture

Limits of resolution result from interference Rayleigh limit for self-luminous objects Abbé limit for illuminated objecs

Microscope Objectives Images from

Microscope Objectives Specimen Coverslip Oil Microscope Objective Stage 60x 1.4 NA PlanApo Refractive Index Cells Water glycerol Glass 1.52 Zeiss Oil Diamond 2.42

Refractive Index Objective n=1.52 Specimen Coverslip Oil n=1.33 n = 1.52 n = 1.0 n = 1.5 Water n=1.52 Air

Spherical Aberration Peripheral ray focus is shorter than more central (paraxial) ray focus. Compromise is ‘Circle of Least Confusion’

Monochromatic Aberrations - Coma Coma is when a streaking radial distortion occurs for object points away from the optical axis. It should be noted that most coma is experienced “off axis” and therefore, should be less of a problem in confocal systems Images reproduced from:

Monochromatic Aberrations - Astigmatism If a perfectly symmetrical image field is moved off axis, it becomes either radially or tangentially elongated. Images reproduced from:

Microscope for widefield epifluorescence Mercury Lamp Dichroic Reflector Objective Sample Stage DIC analyser Dichroic Reflector CCD camera

The CCD Camera Extended red sensitivity 1344(H) X1024(V) pixels 8.3 frames per second (to 45 fps with 8X8 bin)

Scanning the CCD chip

Binning 2X2 16fps 4X4 28fps 8x8 45fps Full well capacity (18000 electrons) Bloom Readout noise (6 electrons) Dynamic Range (6/18000 = 3000)

Electron Multiplying Charge Coupled Device (EMCCD) Impact ionization leads to secondary electrons and amplification before readout Amplification can be as much as 1000x Readout noise is excluded but shot noise is amplified

Fluorescence Microscopy in the Sussex Centre for Advanced Microscopy Roger Phillips Biols 2C9,10,11 Ext 7585