Condition Assessment of Concrete Deck of the International Bridge Using Nondestructive Evaluation (NDE) Nenad Gucunski Rutgers University Center for Advanced Infrastructure and Transportation (CAIT) International Bridge Study Piscataway, New Jersey, June 13, 2011
Rutgers University - CAIT IBS - NDE of Concrete Deck Deck of the International Bridge: Spans 3 & 2
Rutgers University - CAIT IBS - NDE of Concrete Deck Corrosion Half-cell potential – Likelihood of active corrosion Electrical resistivity, GPR and MoistScan – Potential for corrosive environment Concrete Degradation Ultrasonic surface waves (USW) – Modulus degradation GPR – Likelihood of deterioration Delamination Impact echo GPR – Likelihood of delamination in highly attenuated areas Deterioration Types Vs. NDE Method
Rutgers University - CAIT IBS - NDE of Concrete Deck Corrosion Assessment – Half-Cell Potential
Rutgers University - CAIT IBS - NDE of Concrete Deck Half-Cell Corrosion Potential
Rutgers University - CAIT IBS - NDE of Concrete Deck Corrosion Assessment - Electrical Resistivity
Rutgers University - CAIT IBS - NDE of Concrete Deck Electrical Resistivity Measurement Electrical resistivity, kOhm-cm
Rutgers University - CAIT IBS - NDE of Concrete Deck MoistScan Survey (Relative Moisture)
Rutgers University - CAIT IBS - NDE of Concrete Deck MoistScan Moisture Index
Rutgers University - CAIT IBS - NDE of Concrete Deck Ultrasonic Surface Waves – Concrete Modulus
Rutgers University - CAIT IBS - NDE of Concrete Deck Ultrasonic Surface Wave (USW) Testing Concrete modulus, ksi
Rutgers University - CAIT IBS - NDE of Concrete Deck Ground Penetrating Radar (GPR)
Rutgers University - CAIT IBS - NDE of Concrete Deck Ground Penetrating Radar (GPR)
Rutgers University - CAIT IBS - NDE of Concrete Deck Impact Echo Testing by Stepper
Rutgers University - CAIT IBS - NDE of Concrete Deck Delamination Detection by Impact Echo
Rutgers University - CAIT IBS - NDE of Concrete Deck Summary Results Drew Noel Photography, copyright All rights reserved
Rutgers University - CAIT IBS - NDE of Concrete Deck Summary Results - Corrosion Electrical Resistivity in kOhm-cm Half-Cell Potential in mV Moisture Index from MoistScan