Proposal for Convection Absorber Test with Hydrogen at Fermilab Barry Norris Representing colleagues in BD/Cryogenics February 21, 2003.

Slides:



Advertisements
Similar presentations
MICE Coupling Coil Testing at Fermilab MICE Collaboration Meeting Ruben Carcagno March 15, R. Carcagno - MICE CC Testing at Fermilab3/15/2012.
Advertisements

MuCool Outlook and Plans  Over the past year we have had a very successful program that will be detailed in the next two sessions: u MuCool Test Area.
MICE OsC – 22 nd June 2010 Liquid-hydrogen system and absorber M Hills T Bradshaw M Courthold S Ishimoto W Lau I Mullacrane P Warburton.
LArTF and MicroBooNE Installation
Coupling Coil Test Facility Update Ruben Carcagno Fermilab September 20, 2012.
SRF Cryomodule Assembly Facility Plans Tug Arkan AAC, May 10-12, 2005.
MICE AFCSWG Safety Review Summary Mary Anne Cummings Dec. 17, 2003 MICE Video Conference.
MTA Cryostat & cooling loop design Christine Darve Fermilab/Beams Division/ Cryogenic Department/ Engineering and Design Group Preparation of the Mucool/MICE.
LH2 Absorber Heat Load and Homeostasis. What has happened before… 1.Huge LH2 volumes, low heat deposition: Bubble chambers 2.Small LH2 volumes, low heat.
11/26/2002Edgar L Black IIT MICE Video Conference November 27, 2002 Summary of safety implementation for proposal.
Cryogenic Facility for Mucool at Linac MUCOOL – MICE meeting Barry Norris, Engineer, Beams Division/Cryogenic Dept. Fermilab phone:
1 Superconducting Magnets for the MICE Channel Michael A. Green Oxford University Physics Department Oxford OX1-3RH, UK.
March 14, 2003 MICE Absorber/Coil Integration MICE LH2 Absorber 1.Assembly 2.Safety 3.Staging 4.Instrumentation.
Fermi National Accelerator Laboratory FERMILAB CRYOGENIC STATUS Beams Division Cryogenics Barry Norris (overseer) Alex Martinez (helium cryo) Christine.
Matthew Hills Hydrogen System – Piping and Instrumentation Diagram.
Hydrogen Delivery System – R&D Activities T W Bradshaw M Courthold M Hills J Rochford Daresbury Controls Group etc…
Mucool cryo-design Christine Darve Fermilab/Beams Division/ Cryogenic Department 8/12/02.
MICE Hydrogen System Design Tom Bradshaw Iouri Ivaniouchenkov Elwyn Baynham Columbia Meeting June 2003.
Mucool Test Area Cryostat & cooling-loop design Christine Darve Fermilab/Beams Division/ Cryogenic Department/ Engineering and Design Group MuCool / MICE.
MICE hydrogen review Summary of system hardware. System function To provide 22 litres of liquid hydrogen for use as a muon absorber within a superconducting.
LNG Hazards.
Current status Arkadiy Klebaner November 21, 2012
TOTEM Collaboration Meeting, Feb. 2005, F. Haug, CERN Cooling System for TOTEM Friedrich Haug and Jihao Wu Cryogenics for Experiments CERN TOTEM Collaboration.
Engineering and Design Group Fermi National Accelerator Laboratory Cryogenic Department AAC Review, May , 2005 Jay Theilacker HPTFCRYOGENICS.
Fcal upgrade for sLHC: Cryogenics modifications – TE-CRG/ C.Fabre 1 ATLAS FCal Upgrade for sLHC: Modifications to the Calorimeter Cryogenic.
Patrick Thornton, SNS/FPE June 9, 2008
MICE CM30 7 th July 2011 Liquid Hydrogen Delivery System M Hills (STFC, RAL) T Bradshaw (STFC, RAL) M Courthold (STFC, RAL) S Ishimoto (KEK) A Muir (STFC,
Iouri Ivaniouchenkov RAL Safety considerations at RAL July 9, RAL MICE Collaboration Meeting 1.
ILCTA_NML Progress at Fermilab Jerry Leibfritz September 10, 2007.
Options for Absorber Testing Barry Norris’s Random Thoughts November 8th, 2002.
Edgar L. Black MUCOOL ADVANCED M.T.F. & M.I.C.E. LAYOUTS August 12-13, 2002 Edgar L. Black IIT.
CD-03/12/06 – IIT NFMCC meeting Flow Absorber Possibilities C. Darve Fermi National Accelerator Laboratory Batavia, IL, 60500, USA Neutrino Factory & Muon.
MTA Cryogenics: Where We Are The Work of Fermilab AD/Cryo Barry Norris, Christine Darve and a host of wonderfully talented Cryogenic Personnel John Thompson,
MICE Hydrogen Safety Functions IEC61508 Compliance & Emergency Procedures MICE Safety Review Meeting 4 th Oct 2011 PJ Warburton - Daresbury Lab.
128 May 2013 CENF Near Far Integration For the Safety Folder + Environmental impact Study Simple process: Identify Safety issues >> description >> risk.
Status: Tritium Plasma Experiment at the INL Safety and Tritium Applied Research (STAR) Facility R. A. Anderl*, J. P. Sharpe*, R.D. Tillotson* (*INL) R.A.
Hydrogen system R&D. R&D programme – general points Hydrogen absorber system incorporates 2 novel aspects Hydrogen storage using a hydride bed Hydrogen.
Conceptual Design Review of the NPDGamma Experiment in Beam Line 13 Seppo Penttila NPDGamma project manager September 25, 2007 at SNS.
FAIR PROJECT COST BOOK. FAIR cost 1.2 mld euro 1. Civil construction and infrastructure 322Meuro 2. Accelerator systems 592 Meuro 3. Experimental facilities.
Hydrogen Pre-Operation Safety Review 4 th October 2011 Results from Helium Commissioning M Hills.
Safety Requirements and Regulations 10/3/20121Safety Requirements & Regulations James Sears.
MICE Hydrogen Control System MICE Safety Review Meeting 4 th Oct 2011 PJ Warburton - Daresbury Lab.
Section 3 Using Heat.
January 4, 2007 Project Overview RHIC II Project Internal Cost Review Roberto Than Cryogenics Systems January 4, 2007.
MCTF 8/17/06 A. Bross MTA Activities and Plans MCTF August 17, 2006 A. Bross.
1 HIGH ENERGY ACCELERATOR RESEARCH ORGANIZATION KEKB Review Committee/ NAKAI Hirotaka KEK Crab Cavity - Cryogenics - KEKB Crab Cavity Group - presented.
CM 28 – 6 th October 2010 LH2 Infrastructure M Hills M Courthold T Bradshaw I Mullacrane P Warburton.
LH2 Safety Issues for MICE 1.O2/LH2 separation 2.No Ignition sources near LH2 3.Adequate ventilation 4.Affects: Windows: absorbers and vacuum Primary and.
Hydrogen Pre-Operation Safety Review 4 th October 2011 The Hydrogen Delivery System – An Introduction M Hills.
ILC Test Facility at New Muon Lab (NML) S. Nagaitsev Fermilab April 16, 2007.
CM27 – 8 th July 2010 LH2 System Progress and Future Plans M Hills T Bradshaw M Courthold I Mullacrane P Warburton.
Safety Concept and Tests Fakultaet Maschinenwesen, Institut fuer Energietechnik, Bitzer-Stiftungsprofessur für Kaelte-, Kryo- und Kompressorentechnik Jülich,
Project X RD&D Plan Cryogenics Arkadiy Klebaner AAC Meeting February 3, 2009.
Installation of the T600 at Fermilab CSN2, September 22,
Date 2007/Sept./12-14 EDR kick-off-meeting Global Design Effort 1 Cryomodule Interface definition N. Ohuchi.
NML - RF Unit Test Facility Jerry Leibfritz Fermilab.
C. Darve / Technical Board – December 13 th, 2012Preliminary pressure vessel code requirements Preliminary pressure vessel code requirements Technical.
ESS Cryomodule Status Meeting – Elements of Safety | | Christine Darve Elements of Safety Applicable to the ESS 2013 January, 9 th Christine.
Manoj Kumar, B. N. Duttagupta, Rajvir Singh Doohan, S. K. Joshi, A. K. Sagar, L. Chowdhary, Rekhya Naika, Prabhat Kumar Gupta, Vivek Nema, Hemant Kumar.
Thomas Jefferson National Accelerator Facility Page 1 Dana Arenius Cryogenics Control Account Manager 12 GeV Upgrade Project X Collaboration September.
Overview of On-going Cryogenic Work At the MTA Barry Norris AD/Cryo February 14, 2005.
ILCTA_NML Progress at Fermilab Jerry Leibfritz August 16, 2007.
Development of Cryo-Module Test Stand (CMTS) for Fermi Lab (R.L.Suthar, Head,CDM, BARC) Cryo-Module Test stand (CMTS) is a very sophisticated equipment.
Cryomodule Safety Approvals Jay Theilacker LCLS-II Production Cryomodule Final Design Review May 12-14, 2015.
Installation of the T600 at Fermilab Fermilab, February 15,
Replacing hydride bed with bottle Advantages No risk of diminished bed capacity Following jobs no longer necessary – Move pressure gauge – Replace cracked.
NPDG Liquid Hydrogen Target: Design and Safety Features
IT-4189 Supply and installation of a cryogenic distribution system
MICE Safety Review Meeting 4th Oct 2011 PJ Warburton - Daresbury Lab
Experimental equipment Edgar L. Black February 17, 2019
Presentation transcript:

Proposal for Convection Absorber Test with Hydrogen at Fermilab Barry Norris Representing colleagues in BD/Cryogenics February 21, 2003

Proposal for Testing of KEK Convection Absorber Charge: Establish a cryogenic facility to allow performance analysis for a hydrogen absorber Establish a helium distribution system be used for hydrogen gas liquefaction liq liters of hydrogen Provide for safe test area which is based on Fermi Guideline for LH2 Targets Proposal Use Meson Cryogenic Helium system as 17K Build an outdoor area to house KEK test cryostat which provides weather proofing and protection to personal as protection from animals Provide barrier to protect people and capital equipment in the case of an emergency

Safety Issues to Address KEK cryostat must meet FERMILAB ES&H standards and will be required to endure a Safety review - Engineering note for vessel, reliefs, and vacuum info System must be reviewed by Cryogenic panel-- What if, FMEA System must adhere to Guidelines for LH2 Target designs Includes: Electrical standards and Intrinsic safety Proposing Mobile trailers outside of safe area for electrical distribution, DAQ, vacuum pumping. Use of Safety Controls --- we have Quadlog PLC and will house inside of Meson Cryo Building

Arial View of Meson Area with Proposed Setup

Suggested Plans for Testing Convection Absorber at Fermilab In Hydrogen Environment Barry Norris representing my Colleagues in Fermi BD/ Cryo Dept. Feb 21, 2003

Next Steps and Issues as of 2/21/03 Prepare thourogh documentation for Fermi safety review Require assist of KEK, U of I and others Address issues for transporting cryostat in and out of housing as well as lifting absorber from vessel Major issue – how to add heat for convection, beam, and helium heating while adhering to strict safety constraints Electrical heater, light source, gas/thermal fluid source?????

Proposal for Testing of KEK Convection Absorber Charge: Establish a cryogenic facility to allow performance analysis for a hydrogen absorber Establish a helium distribution system be used for hydrogen gas liquefaction liq liters of hydrogen Provide for safe test area which is based on Fermi Guideline for LH2 Targets Proposal Use Meson Cryogenic Helium system as 17K Build an outdoor area to house KEK test cryostat which provides weather proofing and protection to personal as protection from animals Provide barrier to protect people and capital equipment in the case of an emergency

Proposal for Testing of KEK Convection Absorber Charge: Establish a cryogenic facility to allow performance analysis for a hydrogen absorber Establish a helium distribution system be used for hydrogen gas liquefaction liq liters of hydrogen Provide for safe test area which is based on Fermi Guideline for LH2 Targets Proposal Use Meson Cryogenic Helium system as 17K Build an outdoor area to house KEK test cryostat which provides weather proofing and protection to personal as protection from animals Provide barrier to protect people and capital equipment in the case of an emergency

Proposal for Testing of KEK Convection Absorber Charge: Establish a cryogenic facility to allow performance analysis for a hydrogen absorber Establish a helium distribution system be used for hydrogen gas liquefaction liq liters of hydrogen Provide for safe test area which is based on Fermi Guideline for LH2 Targets Proposal Use Meson Cryogenic Helium system as 17K Build an outdoor area to house KEK test cryostat which provides weather proofing and protection to personal as protection from animals Provide barrier to protect people and capital equipment in the case of an emergency

Proposal for Testing of KEK Convection Absorber Charge: Establish a cryogenic facility to allow performance analysis for a hydrogen absorber Establish a helium distribution system be used for hydrogen gas liquefaction liq liters of hydrogen Provide for safe test area which is based on Fermi Guideline for LH2 Targets Proposal Use Meson Cryogenic Helium system as 17K Build an outdoor area to house KEK test cryostat which provides weather proofing and protection to personal as protection from animals Provide barrier to protect people and capital equipment in the case of an emergency

Herculite Room at Fermilab’s Lab 3

Mobile Carts for Power, DAQ, and Vacuum Pumping

Costs for Setup Herculite and unistrut structure $5K Cryogenic transfer piping $3K Hydrogen Manifold for Gas $3K Miscellaneous Cryogenic Instrumentation $10K ODH, Flammable Gas install $5K Piping for venting hydrogen and helium $2K Riggers to Move future MTA helium Tank $2K Approx Total $30K Contingencies Riggers for blocks $5K Electricians for 1 week $5K FESS $5K CONTINGENCY $ 15K