Aerosolized Ribavirin Administration John Dobrozsi R.R.T Clinical Specialist Respiratory Care Services UWMC
Aerosolized Ribavirin Administration
Aerosolized Ribavirin Administration Initial Treatment RN: Completes Ribavirin Initiation Sheet found in “Ribavirin Packet”
Aerosolized Ribavirin Administration Room Preparation RN and RT: Remove non-essential items from room Ask patient to void Patient removes contact lenses if worn Patient dons cloth gown. Hair cover is provided if patient has hair
Aerosolized Ribavirin Administration Room Preparation
RN and RT: Drape patient and bed
Aerosolized Ribavirin Administration Room Preparation
RN and RT: Drape patient and bed Drape horizontal surfaces in room
Aerosolized Ribavirin Administration Room Preparation
RN and RT: Drape patient and bed Drape horizontal surfaces in room Review SPAG ON/OFF procedure
Aerosolized Ribavirin Administration Room Preparation
RN and RT: Drape patient and bed Drape horizontal surfaces in room Review SPAG ON/OFF procedure RN: Call Environmental services of treatment end time
Aerosolized Ribavirin Administration Treatment Initiation RN and RT: Complete Treatment Check List Before Each Treatment
Aerosolized Ribavirin Administration Treatment Initiation RT: Set up DeMistifier tent and tuck in around mattress Tape front opening together on tent
Aerosolized Ribavirin Administration Treatment Initiation
RT: Set up DeMistifier tent and tuck in around mattress Tape front opening together on tent Place aerosol mask on patients face Turn on Demistifier tent and assure concave appearance of tent Check for warning lights on Demistifier control panel
Aerosolized Ribavirin Administration Treatment Initiation
Turn on SPAG nebulizer Observe patient for adverse reactions (Wear PAPR if inside room)
Aerosolized Ribavirin Administration Treatment Initiation
Aerosolized Ribavirin Administration During Therapy Wear full PPE when entering room. SPAG may be turned off if patient care requires entering tent. Leave scavenger tent fan running at all times during treatment.
Aerosolized Ribavirin Administration During Therapy Treatments begin and end at: 22:00 – 00:00 06:00 – 08:00 14:00 – 16:00 New therapy orders will be started at the soonest treatment time following arrival of the drug.
Aerosolized Ribavirin Administration Completing Therapy RT Following the 2 hour treatment, the RT will turn off the SPAG unit. The scavenger tent will continue running until the room is undraped. Drapes on room and patient are folded “inward” upon themselves and placed in linen hamper.
Aerosolized Ribavirin Administration Completing Therapy
The scavenger tent is folded in upon itself with the fan running. The tent remains folded behind the bed until the next treatment.
Aerosolized Ribavirin Administration Completing Therapy
RN calls Environmental Services to alert them of the need for room cleaning. RN and RT sign the back of the Ribavirin treatment check list. Full PPE must be worn until Environmental Services had cleaned the room.
Aerosolized Ribavirin Administration Completing Therapy The procedure for ventilated patients is the same except that a scavenger tent is not used and patient/room draping is unnecessary. The ventilator/SPAG circuit is a closed system.
Aerosolized Ribavirin Administration Completing Therapy At the end of each cycle of therapy, the tent and SPAG parts are disposed of.