Lecture 2 M.Sc.. AA Spectrometer Components Lamp and FlameDetector Fuel Oxidant Nebulizer Double-Click picture for VIDEO.

Slides:



Advertisements
Similar presentations
Atomic Absorption.
Advertisements

Electricity from Chemical Reactions
1.1 Atomic Absorption Spectrometry (AAS) determination of elements not compounds needs radiation source high temperature for atomization Atomization a.
Atomic Absoption Spectroscopy. Electron excitation –The excitation can occur at different degrees low E tends to excite the outmost e - ’s first when.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Chapter 8 & 9 Atomic Absorption Spectroscopy
Atomic spectroscopy  It’s a class of spectroscopic method in which the species examined in the spectrometer are in the form of atoms.
ATOMIC ABSORPTION SPECTROMETER
Spectroscopy Lecture 4 Ahmad Razali Bin Ishak Department of Environmental Health Faculty of Health Sciences UiTM Puncak Alam.
All material required to answer the following questions are contained in the lecture notes. Tutorial CM 3007.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
1 A TOMIC SPECTROMETRIC METHODS PART 9. 2 Interferences : Four classes of interferences: 1-Spectral interferences 2-Chemical interferences 3- Refractory.
Metal Analysis by Flame and Plasma Atomic Spectroscopy Flame A. Atomization 1. Types of Atomization Processes a.) Nebulizers b. Electrothermal atomization.
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Spectroscopy Atomic Spectroscopic Methods Covered in Ch 313: Optical Atomic Spectrometry (Ch 8-10) Atomic X-ray Spectrometry (Ch 12) Atomic Mass.
INTRODUCTION TO OPTICAL METHODS
Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy.
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Flame photometry.
Chem. 133 – 4/7 Lecture. Announcements I Lab –Should be starting Set 2 Period 1 –Set 2 Period 2 Lab Reports due Today Pass Out TH Cheng Award Letters.
Molecular Fluorescence Spectroscopy
Atomic Emission Spectroscopy
Atomic Absorption Spectroscopy (AAS)
Atomic Absorption Spectroscopy (AAS)
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY Chap 9 Source Modulation Interferences in Atomic Absorption Interferences in Atomic Absorption Spectral.
Atomic Absorption Spectroscopy
ATOMIC ABSORPTION SPECTROSCOPY
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Biochemical instrumental analysis-2
Atomic Emission Spectrometry
Atomic Absorption Spectroscopy
Atomic Absorption Spectrophotometer
Atomic Absorption Spectroscopy
Atomic Absorption Spectrometry
AAS Atomic Absorption Spectrophotometry. AAS – Widely in clinical laboratories to measure elements such as aluminum, calcium, copper, lead, lithium, magnesium,
1 Atomic Absorption Spectroscopy Lecture Emission in Flames There can be significant amounts of emission produced in flames due to presence of flame.
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
Chemical Equations and Reactions. Describing Chemical Reactions  A process by which one or more substances are changed into one or more different substances.
Beers Law for a Single Component Sample I0I0 A = Absorbance = - log 10 I I / I 0 b = Optical path length c = Solution Concentration (M/L) ε = Molar Absorptivity.
Chapter 1 Section 1: Matter & its changes Why are elements sometimes called the building blocks of matter?  All matter (anything that has mass and takes.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Atomic-absorption spectroscopy
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
A TOMIC - ABSORPTION SPECTROSCOPY. Atomic absorption spectroscopy (AAS) is a technique for determining the concentration of a particular metal element.
Matter Chemistry is the study of matter Matter takes up space and has mass Matter comes in many different forms.
What is Atomic Spectroscopy? – Sec Atomic Absorption Spectroscopy (AAS) versus Atomic Emission Spectroscopy (AES)
Atomic-absorption spectroscopy Lab3 Atomic-absorption spectroscopy.
Atomic Absorption Spectroscopy
Atomic Absorption Spectroscopy.  Qualitative test for metals in solution  Can also be used for coloured lights  This emission of light is called an.
A TOMIC - ABSORPTION SPECTROSCOPY Lab no. 3 Done by : Iman Al Ajeyan.
Chem. 133 – 4/4 Lecture. Announcements I Strike – If the strike occurs, it will affect classes April 14 th and 18 th (unless ended early) – Lab: would.
1 Chapter 8 Atomic Absorption Spectroscopy ( AAS ) Yang Yi College of Science, BUCT.
Chem. 133 – 4/4 Lecture.
Satish Pradhan Dnyanasadhana College Department Of Chemistry
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY
Flame Photometer.
Chem. 133 – 3/30 Lecture.
Atomic Absorption and Atomic Fluorescence Spectrometry
Elemental composition
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
Satish Pradhan Dnyanasadhana College Department Of Chemistry
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
Atomic Absoption Spectroscopy. Electron excitation –The excitation can occur at different degrees low E tends to excite the outmost e - ’s first when.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

Lecture 2 M.Sc.

AA Spectrometer Components Lamp and FlameDetector Fuel Oxidant Nebulizer Double-Click picture for VIDEO

Nebulizer Components

Nebulizer Operation Vacuum within chamber due to combustion process in the flame of the slot burner. Vacuum results in aspiration (suction) of the analyte solution through the sampling tube. Sample solution enters nebulizer at speed and strikes bead which breaks sample stream into tiny droplets. Resulting mist/vapour is moved under low pressure through the nebulizer to pass a series of baffles. Larger droplets strike the baffles and precipitate to the waste outlet. Vapour consisting of the smallest droplets proceeds unimpeded to the flame.

Interferences 1. Chemical Interference: Formation of stable analyte compounds. Usually due to the presence of phosphate, silicate or aluminate These cause the suppression of alkaline earth metal absorption signal in the flame, e.g., effect of PO 4 3- on Ca. To overcome this interference: - use hotter flame - add a releasing agent such as Sr, or La which preferentially react with phosphate. - add protective chelating agent such as EDTA, which will preferentially complex with the analyte.

Interferences 2. Ionisation Interference: Most common for alkali and alkaline earth metals with low ionisation potentials Reduces atom concentration To reduce add ionisation suppressor or buffer. Typically Caesium is used. 3. Physical Interference: Due to differences between solvent and standards and sample. E.g. Viscosity: viscous solvent aspirated with slower uptake rate, delivers less analyte per unit time to the flame. Therefore, absorbance is lower than for an equivalent concentration in a less viscous solvent.

Interferences 3. Physical Interference continued: Surface Tension: Solvent with lower surface tension provides smaller average droplet size. Less sample lost to drain and larger analyte concentrations reach flame per unit time, i.e., absorbance higher than for an equivalent concentration in a solvent with higher surface tension. Overcome by trying to match physical characteristics of standard and sample.

Interferences 4. Spectral Interference: Due to overlapping spectral lines. Rare due to the narrow line emission of Hollow Cathode Lamp. However, can occur if separation between two lines is around 0.01nm e.g. ANALYTEINTERFERENT Mg Na nm Al V Cu Eu Main spectral interference due to molecular absorbance and scatter of source radiation.

Interferences Molecular absorbance: commonly due to molecules such as NaCl and Ca(OH) 2 Spectral interferences are overcome by various background correction methods.

Interferences 4. Spectral Interference continued: Both reduce transmitted intensity and lead to positive analytical errors. Scattering can be caused by Carbon particles in the flame or by unvapourised solid particles. Usually caused by elements such as Ti, Zr and W, which form stable metal oxide particles. 5. Occlusion: e.g., effect of Fe on Cr in steel analysis. High concentration of Fe causes formation of particles where Cr is trapped and cannot evaporate or be reduced to atoms efficiently. To overcome add EDTA or NH 4 Cl to standard and samples.

Interferences 5. Occlusion continued: EDTA complexes Fe and Cr and helps prevent formation of occlusion sites. NH 4 Cl is highly volatile salt that explosively evaporates in the flame, resulting in a smaller, more easily evaporated particles.