Team Members: Pramod Varshney, Can Isik, Chilukuri Mohan,

Slides:



Advertisements
Similar presentations
Autonomic Scaling of Cloud Computing Resources
Advertisements

Introduction Build and impact metric data provided by the SGIG recipients convey the type and extent of technology deployment, as well as its effect on.
Carrier Controls Demand Controlled Ventilation. Comfort = Temperature + Ventilation Comfort Is More Than Just The Right Temperature… Ventilation Control.
The Role of Controls for Indoor Air Quality Kent W. Peterson, PE, Fellow ASHRAE P2S Engineering, Inc. Mid Columbia ASHRAE Chapter.
HVAC Test and Balance And The Lodging Industry. Source: Florida Power.
Coverage Estimation in Heterogeneous Visual Sensor Networks Mahmut Karakaya and Hairong Qi Advanced Imaging & Collaborative Information Processing Laboratory.
MENG 547 LECTURE 3 By Dr. O Phillips Agboola. C OMMERCIAL & INDUSTRIAL BUILDING ENERGY AUDIT Why do we audit Commercial/Industrial buildings Important.
Optimal Design Laboratory | University of Michigan, Ann Arbor 2011 Design Preference Elicitation Using Efficient Global Optimization Yi Ren Panos Y. Papalambros.
Resource Management of Highly Configurable Tasks April 26, 2004 Jeffery P. HansenSourav Ghosh Raj RajkumarJohn P. Lehoczky Carnegie Mellon University.
Chapter 15 Application of Computer Simulation and Modeling.
{ Fast Disparity Estimation Using Spatio- temporal Correlation of Disparity Field for Multiview Video Coding Wei Zhu, Xiang Tian, Fan Zhou and Yaowu Chen.
Volkan Cevher, Marco F. Duarte, and Richard G. Baraniuk European Signal Processing Conference 2008.
Evolutionary Computational Intelligence Lecture 10a: Surrogate Assisted Ferrante Neri University of Jyväskylä.
Location Estimation in Sensor Networks Moshe Mishali.
What’s Really Happening?. Building Smart, Building Green… Smart building technologies can improve buildings’ energy efficiency and indoor environmental.
Engineering Data Analysis & Modeling Practical Solutions to Practical Problems Dr. James McNames Biomedical Signal Processing Laboratory Electrical & Computer.
SAC Review 07/31-08/01/ Welcome! Strategically Targeted Research in Intelligent Built Environmental Systems EPA Contract # CR & X
Simulation Models as a Research Method Professor Alexander Settles.
UNIVERSITY OF JYVÄSKYLÄ Resource Discovery Using NeuroSearch Presentation for the Agora Center InBCT-seminar Mikko Vapa, researcher InBCT 3.2.
POLITECNICO DI TORINO TRIBUTE and DIMMER. DIMMER - The context One of the major challenges in today’s economy concerns the reduction in energy usage and.
Overview of Model Predictive Control in Buildings
Objectives of NatVent This seven nation pan European project aims to reduce primary energy consumption (and consequently CO2 emissions) in office type.
High Performance Buildings Research & Implementation Center (HiPer BRIC) December 21, 2007 Indoor Environment in Commercial Buildings Connection to reducing.
Introduction Due to the recent advances in smart grid as well as the increasing dissemination of smart meters, the electricity usage of every moment in.
Presented by Amira Ahmed El-Sharkawy Ibrahim.  There are six of eight turtle species in Ontario are listed as endangered, threatened or of special concern.
Fault Diagnosis System for Wireless Sensor Networks Praharshana Perera Supervisors: Luciana Moreira Sá de Souza Christian Decker.
CRESCENDO Full virtuality in design and product development within the extended enterprise Naples, 28 Nov
Sensor-Based Fast Thermal Evaluation Model For Energy Efficient High-Performance Datacenters Q. Tang, T. Mukherjee, Sandeep K. S. Gupta Department of Computer.
Application of Integrated Methodology Multicriteria Building Energy Analysis using Models of Dynamic Energy Simulation Unique Perspectives in bioclimatic.
POWER CONTROL IN COGNITIVE RADIO SYSTEMS BASED ON SPECTRUM SENSING SIDE INFORMATION Karama Hamdi, Wei Zhang, and Khaled Ben Letaief The Hong Kong University.
Saving with Comfort. Confidential - 1 Note: This diagram can represent heating or cooling scenarios 1. Single thermostat systems are ineffective at providing.
Chapter 6 : Software Metrics
November 1, 2012 Presented by Marwan M. Alkhweldi Co-authors Natalia A. Schmid and Matthew C. Valenti Distributed Estimation of a Parametric Field Using.
SDB Demand-Controlled Ventilation: Preliminary Experiments Jay Taneja Software Defined Buildings Kickoff January 11 th, 2013.
1 EnviroStore: A Cooperative Storage System for Disconnected Operation in Sensor Networks Liqian Luo, Chengdu Huang, Tarek Abdelzaher John Stankovic INFOCOM.
Improved Precision Leading to Improved Energy Efficiency Edward Decker AE 790 – Intelligent Buildings June 6, 2006.
Synthetic Cognitive Agent Situational Awareness Components Sanford T. Freedman and Julie A. Adams Department of Electrical Engineering and Computer Science.
1 Webcam Mouse Using Face and Eye Tracking in Various Illumination Environments Yuan-Pin Lin et al. Proceedings of the 2005 IEEE Y.S. Lee.
MURI: Integrated Fusion, Performance Prediction, and Sensor Management for Automatic Target Exploitation 1 Dynamic Sensor Resource Management for ATE MURI.
Detection, Classification and Tracking in a Distributed Wireless Sensor Network Presenter: Hui Cao.
1 P. David, V. Idasiak, F. Kratz P. David, V. Idasiak, F. Kratz Laboratoire Vision et Robotique, UPRES EA 2078 ENSI de Bourges - Université d'Orléans 10.
Advanced Controls and Sensors David G. Hansen. Advanced Controls and Sensors Planning Process.
Probabilistic Coverage in Wireless Sensor Networks Authors : Nadeem Ahmed, Salil S. Kanhere, Sanjay Jha Presenter : Hyeon, Seung-Il.
A Passive Approach to Sensor Network Localization Rahul Biswas and Sebastian Thrun International Conference on Intelligent Robots and Systems 2004 Presented.
Towards Environmental Monitoring with Mobile Robot M. Trincavelli, M. Reggente, S. Coradeschi, A. Loutfi, A. Lilienthal, AASS, Dept. of Technology, Örebro.
A. Hangan, L. Vacariu, O. Cret, H. Hedesiu Technical University of Cluj-Napoca A Prototype for the Remote Monitoring of Water Parameters.
Wireless Sensing and Control of the Indoor Environment in Buildings  Objective: Develop techniques to improve building operation through intensive wireless.
Adaptive Tracking in Distributed Wireless Sensor Networks Lizhi Yang, Chuan Feng, Jerzy W. Rozenblit, Haiyan Qiao The University of Arizona Electrical.
Fast Query-Optimized Kernel Machine Classification Via Incremental Approximate Nearest Support Vectors by Dennis DeCoste and Dominic Mazzoni International.
Process Asad Ur Rehman Chief Technology Officer Feditec Enterprise.
Collaborative Filtering via Euclidean Embedding M. Khoshneshin and W. Street Proc. of ACM RecSys, pp , 2010.
Learning for Physically Diverse Robot Teams Robot Teams - Chapter 7 CS8803 Autonomous Multi-Robot Systems 10/3/02.
Problem Description: One line explanation of the problem to be solved Problem Description: One line explanation of the problem to be solved Proposed Solution:
An Energy-Efficient Approach for Real-Time Tracking of Moving Objects in Multi-Level Sensor Networks Vincent S. Tseng, Eric H. C. Lu, & Kawuu W. Lin Institute.
1 Tom Edgar’s Contribution to Model Reduction as an introduction to Global Sensitivity Analysis Procedure Accounting for Effect of Available Experimental.
Non-parametric Methods for Clustering Continuous and Categorical Data Steven X. Wang Dept. of Math. and Stat. York University May 13, 2010.
Concepts on Aerosol Characterization R.B. Husar Washington University in St. Louis Presented at EPA – OAQPS Seminar Research Triangle Park, NC, April 4,
Copyright © 2015 Optimum Energy LLC. All Rights Reserved. Proprietary & Confidential Incorporating Energy Conservation Strategies into University Research.
Efficient Opportunistic Sensing using Mobile Collaborative Platform MOSDEN.
Data Mining Techniques Applied in Advanced Manufacturing PRESENT BY WEI SUN.
LECTURE 5 Nangwonvuma M/ Byansi D. Components, interfaces and integration Infrastructure, Middleware and Platforms Techniques – Data warehouses, extending.
Lecture Objectives: Accuracy of the Modeling Software.
Monitoreo y Administración de Infraestructura Fisica (DCIM). StruxureWare for Data Centers 2.0 Arturo Maqueo Business Development Data Centers LAM.
7. Air Quality Modeling Laboratory: individual processes Field: system observations Numerical Models: Enable description of complex, interacting, often.
Management Of The Built Environment To Reduce Exposure Risk
Reduced-Order Models for Building Interzonal Transport EPA04 T3.2
EPA04 T3.2 Reduced order models for Building Interzonal Transport
Luís Filipe Martinsª, Fernando Netoª,b. 
Personalized HVAC Control System
Presentation transcript:

Team Members: Pramod Varshney, Can Isik, Chilukuri Mohan, H. Ezzat Khalifa, Onur Ozdemir, Ramesh Rajagopalan, Priyadip Ray, James Smith, Jensen Zhang Management Of The Built Environment To Reduce Exposure Risk

EPA SAC 08/10-11/ Outline o SAC Main Concerns o Problem u Definition u Motivation and Objectives u Research Needs o Integrated Components of this Task u Optimization and control u Indoor Sensor Networks u Testbeds o Summary and Future Work

EPA SAC 08/10-11/ SAC Main Concerns o “…a lot of the work was premature pending definition of a plausible problem scenario…” o “…an approach based on temperature or CO2 control might be feasible but should only be considered if the state of the art in indoor environmental controls will be advanced…” o “…necessary to refocus this effort…” o “…consult with practicing HVAC engineers, and make inquiries from professionals in the industry…”

EPA SAC 08/10-11/ The Problem Definition o How can we improve the indoor air quality (IAQ) around each individual in a built environmental system (BES) while keeping the cost at a reasonable level? u Treat built environment as a collection of multiple controllable zones u Shift from one-size-fits all (OSFALL) paradigm and move towards have-it- your-way (HYWAY) paradigm.

EPA SAC 08/10-11/ There is no Free Lunch! o Improved health, productivity and comfort, at the expense of increased system complexity: o Additional infrastructure o Increase in cost, computation, communication and actuation o Additional burden of coupling effect between zones

EPA SAC 08/10-11/ Motivation and Objectives o Existing “one size fits all” solutions leave many occupants dissatisfied with their environments, limiting productivity and affecting health “New research shows that higher IAQ improves health, learning and productivity” - Dr. Ole Fanger o Empowering each occupant with the ability to control one’s own environment improves satisfaction and productivity; expected technological changes will help realize this vision. This will require a paradigm shift in HVAC technology “I predict a dramatic change in HVAC technology in the future” - Dr. Ole Fanger

EPA SAC 08/10-11/ Research Needs o Controlling individual environments while keeping the cost at a reasonable level is an optimization problem, whose solution requires: u Measuring environmental parameters at an individual level with a complex network of sensors u Providing control actuators at an individual scale but with coordination u Reacting to changes in the system variables such as occupancy and weather conditions o In order to customize the IAQ, a network of sensors, controllers and actuators is needed. A wireless network allows low-cost retrofitting of existing buildings

EPA SAC 08/10-11/ Goal Implement cost effective personal control of the microenvironment, which enhances individual health, satisfaction and productivity, by integrating sensing, intelligent information processing and distributed control,.

EPA SAC 08/10-11/ Integrated Components of this Task o Improve indoor air quality by: u Optimization and control – new methodologies for real-time control u Indoor sensor network – design, placement, data processing, and spatio- temporal profiling u Test-beds – design of new test-beds and implementation of developed methodologies on these test-beds

EPA SAC 08/10-11/ Micro-Level Demand-Controlled Ventilation (DCV) o Main Objective: To improve IAQ around each individual in an office building o Approach: Develop optimization algorithms that will improve IAQ in every single office for each individual o Constraints: Energy consumption, costs and individual comfort

EPA SAC 08/10-11/ DCV At The Micro Level o Emissions in a room*: u CO 2 - surrogate for emissions by people or through human activity u TVOC – surrogate for emissions from room contents and furniture o Our Focus: CO 2 levels as the IAQ criterion for optimization o Goal: Optimization of ventilation rates (CO 2 levels) and energy costs in a multi-zone BES o Approach: DCV at the micro-level with one controllable diffuser in each room (e.g., Variable Air Volume – VAV) *ASHRAE Std allows for ventilation rates based on both occupancy and floor area. A DCV system based only on CO 2 will address the people component but not the passive component.

EPA SAC 08/10-11/ CO2 Levels and Energy o For a single zone u CO2 concentration at steady state is known u u The energy model is known* FMain energy consumed by the HVAC is proportionally related to the cooling/heating coil loadenergy * S.Atthajariyakul, T. Leephakpreeda,”Real-time determination of optimal indoor-air condition for thermal comfort, air quality and efficient energy usage”, Energy and Buildings, vol.36, pp , 2004

EPA SAC 08/10-11/ Illustrative Example o An office building with 25 rooms: u Intra-room uniformity: One temperature and RH value assumed within each room(well-mixed conditions) u Inter-room uniformity: All rooms have identical DBT and RH values u Occupancy: 82 people in the building, with 1-5 people in each room u Goal: Find optimum outside airflow rates (F o ) for each room, with: FMinimal energy consumption FCO 2 levels Ci < 800 ppm threshold in each room

EPA SAC 08/10-11/ Preliminary Results For the same total airflow rate, we compare two alternatives: u OSFA solution: Same airflow rate (F o ) in each office u HIYW solution: F o adjusted using occupancy information (room-level DCV)

EPA SAC 08/10-11/ Preliminary Results o Improved IAQ at the same energy cost o Future Work: Optimization based on airflow dynamics between rooms (Task3.2), variable indoor air temperatures, occupancy variations and variable metabolic rates DCV at the Micro Level (HYWAY) OSFALL Solution Power Consumption (kW) 56.6 # of Occupants for whom C i > 800 ppm 056 of 82 # of Rooms where C i >800 ppm 013 of 25

EPA SAC 08/10-11/ Paradigm Shift from OSFA to HIYW Requires Distributed Sensing Distributed Communication Distributed Actuation OSFA HIYW Increased system complexity

EPA SAC 08/10-11/ Integrated Components of this Task o Improve indoor air quality by u Optimization and control – improved IAQ via new methodologies for real-time control u Indoor sensor network – design, placement, data-processing and spatio- temporal profiling u Test-beds – design of new test-beds and implementation of developed methodologies on these test-beds

EPA SAC 08/10-11/ Why Distributed Large-scale Sensor Networks? o Multiple sensors needed to acquire state information in each micro- environment, for implementation of HYWAY paradigm o Higher resolution and fidelity data available in a sensor-rich environment will improve distributed monitoring o Sensors need to be networked for system-wide optimization and real- time control of i-BES o Wireless networks facilitate lower-cost retrofitting of existing buildings

EPA SAC 08/10-11/ Previous Work o N. Lin, C. Federspiel and D. Auslander, “Multi-sensor Single-Actuator Control of HVAC Systems”, Int. Conf. For Enhanced Building Operations, Richardson, TX, 2002 u Simulation results demonstrating the advantage of using atleast one sensor for each room compared to one sensor for many rooms u Assumes a single actuator o Wang, D. E., Arens, T. Webster, and M. Shi. "How the Number and Placement of Sensors Controlling Room Air Distribution Systems Affect Energy Use and Comfort." International Conference for Enhanced Building Operations, Richardson, TX, October, 2002 u Simulations results showing the benefits of using more than one temperature sensor to control conditions in the occupied zone of a room

EPA SAC 08/10-11/ Previous Work (cont’d) o H.Zhang, B.Krogh, J.F. Moura and W.Zhang,”Estimation in virtual sensor- actuator arrays using reduced-order physical models”, 43rd IEEE Conference on Decision and Control, December 14-17,Atlantis, 2004 u Application of sensor networks for real-time estimates of the values of a distributed field at points where there are no sensors u Assumes linear system models o Clifford C. Federspiel, “Estimating the Inputs of Gas Transport Processes in Buildings”, IEEE Trans. on Control Systems Technology, 1997 u Estimation of the strength of a gas source in an enclosure u Applies Kalman filtering for state estmation

EPA SAC 08/10-11/ Multi-sensor Detection and Sensor Placement o Application of multiple sensors for improved detection of indoor pollutants u Improved detection enables reduced exposure of occupants to pollutants o Development of cost-effective sensor placement strategies for improved indoor air quality

EPA SAC 08/10-11/ Multi-sensor Detection – Example Simulated concentration profile of a gaseous pollutant released in still air at a point in a room of 9m x 10m x 6m dimensions with source located at (5,5,0)

EPA SAC 08/10-11/ Numerical Example o An example demonstrating the utility of multiple sensors for fast detection of a pollutant. The simulations are for a room with source located at the center of the room Probability of detecting whether pollutant concentration exceeds a predefined threshold

EPA SAC 08/10-11/ Sensor Placement Problem o Goal: To determine optimal locations of sensors for detection of gaseous pollutants in a room or a large hall o Evaluation measure: Improved probability of detection of gaseous indoor air pollutants o Constraint: Number of sensors to be deployed o We assume a spatial probability distribution for the location of the source. o Approaches: u Uniform placement where sensors are equi-spaced from each other u Closest point placement where sensors are placed at locations closest to the mean of the spatial source distribution u Intelligent placement strategies for quick pollutant detection and reduction of exposure time

EPA SAC 08/10-11/ Simulation Results o Sensor placement results with 3 sensors placed in a 9x10x6m room o Intelligent placement strategy outperforms intuitive strategies such as uniform placement in terms of the detection probability ApproachDetection probability Uniform placement0.35 Closest point placement0.68 Intelligent placement strategy (Evolutionary algorithm with local search) 0.97

EPA SAC 08/10-11/ Spatio-temporal Profiling of Environ. Parameters o In environmental applications, sensor networks monitor physical variables governed by continuous distributed dynamics u Results in correlated sensor observations o Difficulty: Spatial and temporal irregularities in sampling o Problem: Produce real-time estimates of the values of a distributed field at points where there are no sensors* *H.Zhang, B.Krogh, J.F. Moura and W.Zhang,”Estimation in virtual sensor- actuator arrays using reduced-order physical models”, 43 rd IEEE Conference on Decision and Control, December 14-17,Atlantis, 2004.

EPA SAC 08/10-11/ Our Approach o We propose a supervised local function learning approach to estimate the observation of a sensor from a subset of its neighbors o The goal is to estimate an unknown continuous-valued function in the relationship y = g(X) + n where, the random error/noise (n) is zero-mean, X is a d-dimensional vector (e.g., Position coordinates of sensors) and y is a scalar output (e.g., concentration of CO2)

EPA SAC 08/10-11/ Our Approach (cont’d) o A generalized regression neural network (GRNN) has been used, due to its superior interpolation abilities and fast convergence o GRNN learns the spatial concentration function from the observations provided by sensors in the neighborhood (circular region) of a desired location The objective is the real time estimation of concentration value at point C from the neighboring sensors c : Location of sensors Illustrative Example

EPA SAC 08/10-11/ Simulation Results for Spatial Profiling of CO 2 - 1/2 o Estimation of the CO 2 levels at each microenvironment from sparsely distributed sensors One realization of the spatial profile of CO 2 and location of sensors

EPA SAC 08/10-11/ Simulation Results for Spatial Profiling of CO 2 – 2/2 How many sensors are adequate ? Summary : About 70 sensors are adequate for MSE of 0.06; additional sensors do not significantly improve MSE

EPA SAC 08/10-11/ Outcomes o The “right number” of sensors can be determined to reduce cost o Development of multi-criteria, system-wide optimization methodologies for HYWAY systems u Multiple, interdependent, individually customized microenvironments controlled by distributed environmental control systems (e.g., PVDs) will be aided by the fine-grained characterization of IAQ parameters Future Work: Reduced order models for building inter-zonal transport (Task 3.2) will provide more realistic and computationally faster models to test our algorithms

EPA SAC 08/10-11/ Experimental CO 2 Data - Location of Sensors In collaboration with Reline Technology, India; University of Technology, Sydney, Australia

EPA SAC 08/10-11/ Experimental* CO 2 Data – Concentration Levels *More details about this experimental test-bed are provided in subsequent slides

EPA SAC 08/10-11/ Integrated Components of this Task o Improve indoor air quality by u Optimization and control – improved IAQ via new methodologies for real-time control u Indoor sensor network – design, placement,data-processing and spatio- temporal profiling u Test-beds – design of new test-beds and implementation of developed methodologies on these test-beds

EPA SAC 08/10-11/ Sensor Network Testbed in Link Hall o Goal : Data collection and evaluation platform for various control and data-processing algorithms being developed u Wireless sensor network test-bed is being set-up on 3 rd floor of Link Hall u Four closed spaces/rooms on the third floor of link hall will be monitored by the WSN FEach closed space will have 5 ABLE ARH-T-2-I-W temperature & RH sensors, 5 TI 4GS CO 2 sensors,1 pressure sensor and a information processing unit called “Sensor Network Access Point (SNAP)” u In future this test-bed will be incorporated in the building control system for evaluation of the complete system

EPA SAC 08/10-11/ Sensor Network Test-bed in Link Hall (cont’d) Possible Locations of SNAPs

EPA SAC 08/10-11/ ICUBE Lab (2007) o Goal: Allow people to adjust their own indoor air parameter settings within an office or a cubicle while maximizing overall energy usage u Giving people (users of the lab) what they want for control settings without increasing baseline costs for the larger space o The lab will consist of one test lab (with uniform settings) and one control lab (with individual settings) u The lab will feature intelligent controls, sensor networks u The lab will employ raised floor diffusers with actuated damper controls o The lab will behave like a real building, with people able to adjust their own thermostat settings u Multiple configurations will be possible: classroom to office to lab

EPA SAC 08/10-11/ ICUBE Lab

EPA SAC 08/10-11/ Testbed Ready for Comparison of New Algorithms o Main Goal: Develop and test multiple-input multiple-output (MIMO) control algorithms for intelligent HVAC control o DAQ system and the actuators have been installed on the HVAC demonstrator (Hampden H-ACD-2-CDL) in Link-0031 u System Characterization Experiments (full capability) u Single-Input Single-Output (SISO) Control Experiments (full capability) u MIMO Control Experiments with combination of CO 2, TVOC and temperature control (technically ready, awaiting CO 2 and TVOC sensors)

EPA SAC 08/10-11/ System Characterization o SISO Temperature Open Loop Response u Illustration of DAQ on the HVAC demonstrator u Enables system characterization so that control algorithms can be developed* *M.L. Anderson, M.R. Buehner, P.M. Young, D.C. Hittle, C. Anderson, J. Tu, and D. Hodgson, “An Experimental System for Advanced Heating, Ventilating, and Air Conditioning (HVAC) Control”, to appear in Energy and Buildings, 2006

EPA SAC 08/10-11/ SISO Control o SISO Temperature Control u Illustration of developed SISO controller on the HVAC demonstrator o Future Work: Develop and test MIMO controllers that will enable us to overcome coupling effects existing in today’s state-of-the-art HVAC systems resulting in improved performance* * M.L. Anderson, M.R. Buehner, P.M. Young, D.C. Hittle, C. Anderson, J. Tu, and D. Hodgson, “MIMO Robust Control for Heating, Ventilating, and Air Conditioning (HVAC) Systems”, submitted to IEEE Transactions on Control Systems Technology, 2005 T ref1 = 79 ºF T ref2 = 77 ºF

EPA SAC 08/10-11/ Summary and Future Work o Optimization and control u Algorithms that enable us to move towards HYWAY paradigm without compromising comfort and energy costs are being developed u More complex and realistic algorithms will be developed and tested on real test-beds o Indoor sensor network u Algorithms are being developed for improved multi-sensor detection, sensor placement and spatio-temporal profiling u Algorithms will be tested on more realistic models (obtained from Task 3.2) and actual test-beds (Task 5) o Test-beds u Work is in progress on the set-up of sensor network test-beds u Work is in progress on the set-up of HVAC test-beds

EPA SAC 08/10-11/ Conclusion o “…a lot of the work was premature pending definition of a plausible problem scenario…” u We have presented a specific problem scenario in terms of the OSFA versus HIYW paradigm shift o “…an approach based on temperature or CO 2 control might be feasible but should only be considered if the state of the art in indoor environmental controls will be advanced…” u We are focusing on temperature and CO 2 control at the micro- environment level (personal level ) o “…necessary to refocus this effort…” u Significant refocusing of the effort as detailed in the presentation has been done o “…consult with practicing HVAC engineers, and make inquiries from professionals in the industry…” u We have initiated collaboration with United Technologies Research Center