Status of the Forward Elastic Scattering Luminosity Monitor Hampton University, Hampton, VA 23668 Jefferson Laboratory, Newport News, VA 23606 OLYMPUS.

Slides:



Advertisements
Similar presentations
Study of Large-area GEM Detectors for a Forward Tracker at a Future Electron-Ion Collider Experiment Aiwu Zhang, Vallary Bhopatkar, Marcus Hohlmann Florida.
Advertisements

Kondo GNANVO Florida Institute of Technology, Melbourne FL.
Ozgur Ates Hampton University TREK Experiment “Tracking and Baseline Design” And OLYMPUS Experiment “Study of Systematics” 1.
Ozgur Ates Hampton University HUGS 2009-JLAB TREK Experiment “Tracking and Baseline Design”
GEM Detectors for AnDY Nilanga Liyanage University of Virginia 1 Outline GEM chamber concept Large area GEM chamber projects Proposed GEM configuration.
Status of the ATLAS MM project
D. Peterson, “Tracking Detector R&D at Cornell University and Purdue University” LC-TPC-LBL 18-Oct Tracking Detector R&D at Cornell University and.
“THE OLYMPUS LUMINOSITY MONITORS” Ozgur Ates Hampton University 1  A Review of the MC Studies of the Lumi Monitors  Some GEM Reports from PREX at JLAB.
Schedule Remove ARGUS experiment - Fall 2009 Disassemble and ship OLYMPUS detector - Spring 2010 Ship target and beamline – Fall 2010 Modify DORIS beam-line.
THE BRIEF HISTORY OF LuMo CONSTRUCTION FROM MIT TO HU OZGUR ATES HAMPTON UNIVERSITY OLYMPUS COLLABORATION MEETING APRIL 2011.
Luminosity Monitor MWPCs, commissioning. A.Kiselev OLYMPUS Collaboration Meeting DESY, Hamburg,
DESY PRC May 10, Beyond the One Photon Approximation in Lepton Scattering: A Definitive Experiment at DESY for J. Arrington (Argonne) D. Hasell,
“THE OLYMPUS LUMINOSITY MONITORS” Ozgur Ates Hampton University 1  OLYMPUS  Two Photon Exchange in Elastic Scattering  Principle of The Experiment 
D. Peterson, “Status of the Cornell/Purdue Program” TPC R&D Mini Workshop, Orsay 12-January Status of the Cornell/Purdue Program: first events with.
Two-photon exchange: experimental tests Studying the QED expansion for elastic electron-proton scattering Motivation The Three Experiments Summary With.
D. Peterson, “The Cornell/Purdue TPC”, ALCPG, Snowmass, 23-August The Cornell/Purdue TPC Information available at the web site:
OLYMPUS Luminosity Monitors
Detector Upgrades and Responsibilities Hampton University, Hampton, VA 23668, USA Workshop, DESY, March 31, 2008 Michael Kohl.
Luminosity Monitor Hampton University, Hampton, VA Jefferson Laboratory, Newport News, VA USA OLYMPUS Collaboration Meeting, DESY, July 17-18,
Monte-Carlo simulations and reconstruction for 12-degree ep-elastic Luminosity Monitor A.Kiselev OLYMPUS Collaboration Meeting DESY, Hamburg,
Luminosity Monitor MWPCs, test beam 22 results. A.Kiselev OLYMPUS Collaboration Meeting DESY, Hamburg,
D. Peterson, “Tracking Detector R&D at Cornell University and Purdue University” ALCPG SLAC 07-Jan Tracking Detector R&D at Cornell University and.
Richard MilnerDESY April 6, OLYMPUS Overview Motivation for the experiment Progress to date on the experiment The path forward.
Luminosity Monitor based on Forward Elastic Scattering Hampton University, Hampton, VA Jefferson Laboratory, Newport News, VA OLYMPUS Collaboration.
Nilanga Liyanage University of Virginia UVa GEM Team Dr. Kondo Gnanvo, Dr. Vladimir Nelyubin, Kiadtisak Saenboonruang, Chao Gu, Xinzhan Bai, Jie Liu, Seth.
WP2: Detector development Summary G. Pugliese INFN - Politecnico of Bari.
SHMS Detector Commissioning and Installation Howard Fenker Hall-C Users Meeting Jan-2015.
1 SBS Spectrometer / GEP5 Conf.. 2 Tracking Requirements Requirements Tracking Technology DriftMPGDSilicon High Rate: MHz/cm 2 (Front Tracker)
DESY A proposal to definitively determine the contribution of multiple photon exchange in elastic lepton-nucleon scattering Hampton University.
Neutron Structure Functions and a Radial Time Projection Chamber The Structure of the Neutron The BoNuS Experiment at CLAS A New Proton Recoil Detector.
John LeRose March 12, A Program of three “projects” to assemble the Super BigBite Spectrometer for a series of experiments in Hall A There is a.
Status Update of OLYMPUS and TREK Hampton University, Hampton, VA Jefferson Laboratory, Newport News, VA HU Group Meeting, Hampton University,
The Bigbite second GEM tracker. SBS GEM Trackers Front Tracker Geometry x6 18 modules In Italy  50 cm x 40 cm Modules are assembled to form larger chambers.
HallA/SBS – Front Tracker PARAMETERDESIGN VALUE Microstrip Silicon Detector Number of tiles/plane and size2 Number of planes2 Size of the single
GEM chambers for SoLID Nilanga Liyanage University of Virginia.
GEM chambers for SoLID Nilanga Liyanage University of Virginia.
The new set of MWPCs for CB Collaboration Meeting Glasgow March 2006 A. Braghieri, P.Pedroni.
Update on SBS Back Tracker UVa K. Gnanvo, N. Liyanage, V Nelyubin, K. Saenboonruang, Seth Saher, Nikolai Pillip (visiting from Univ. Tel Aviv, Israel)
GEM R&D Update Kondo Gnanvo. Outline  GEM R&D and assembly facilities at UVa  Cosmic test results  Update on the 40 × 50 cm 2 GEM prototype  Plans.
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger,
GEM Trackers for Super BigBite Spectrometer (SBS) in Hall JLab The Super Big Bite Spectrometer (SBS) is one of the major new equipment in hall A in.
Update on the Triple GEM Detectors for Muon Tomography K. Gnanvo, M. Hohlmann, L. Grasso, A. Quintero Florida Institute of Technology, Melbourne, FL.
Luca Spogli Università Roma Tre & INFN Roma Tre
Total Cross Section, Elastic Scattering and Diffraction Dissociation at the LHC January 17, 2003TOTEM plenary meeting -Marco Bozzo1 CSC detectors for T1.
Test of the GEM Front Tracker for the SBS Spectrometer at Jefferson Lab F. Mammoliti, V. Bellini, M. Capogni, E. Cisbani, E. Jensen, P. Musico, F. Noto,
GEp-III in Hall C Andrew Puckett, MIT On behalf of the Jefferson Lab Hall C GEp-III Collaboration April 15, 2008.
Large-Area GEM Detector Development at CMS, RD51, and Fl. Tech – A brief overview – Marcus Hohlmann Florida Institute of Technology, Melbourne, FL PHENIX.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
The DAMPE STK G. Ambrosi INFN Perugia. The DAMPE Detector Mass: 1480 Kg Power: 600 W Data: 16 Gbyte/day Liftime: 5 years 2.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
Quality control for large volume production GEM detectors Christopher Armaingaud On behalf of the collaboration GEMs for CMS.
The 12 GeV equipment Hall D – Hall D – GLUEx detector for photoproduction experiments Hall B – Large acceptance detector CLAS12 for high luminosity measurements.
Front Tracker: main technical solutions 40x50 cm 2 module Front Tracker Chamber: 40x150 cm 2  Use COMPASS approach: 3xGEM, 2D readout - one significant.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
Low Momentum dE/dx Testbeam H.P. 7/24/98. Goals for Spectrometer are based on tracking and PID –Multiparticle correlation –production of particle species.
LHCf Detectors Sampling Calorimeter W 44 r.l, 1.6λ I Scintilator x 16 Layers Position Detector Scifi x 4 (Arm#1) Scilicon Tracker x 4(Arm#2) Detector size.
Status of OLYMPUS Hampton University, Hampton, VA Jefferson Laboratory, Newport News, VA HU Group Meeting, March 02, 2010 Michael Kohl.
RD51 GEM Telescope: results from June 2010 test beam and work in progress Matteo Alfonsi on behalf of CERN GDD group and Siena/PISA INFN group.
1- Handling The Olympus GEMs at MIT-BATES between June 6th-August 8th Manufacturing The GEMs at HU-GEM LAB since Sep 2010 OZGUR ATES HAMPTON UNIVERSITY.
P.F.Ermolov SVD-2 status and experimental program VHMP 16 April 2005 SVD-2 status and experimental program 1.SVD history 2.SVD-2 setup 3.Experiment characteristics.
Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Thesis Committee Review Meeting 2003/12/4.
Precision Drift Tube Detectors for High Counting Rates O. Kortner, H. Kroha, F. Legger, R. Richter Max-Planck-Institut für Physik, Munich, Germany A. Engl,
TPC for ILC and application to Fast Neutron Imaging L. An 2, D. Attié 1, Y. Chen 2, P. Colas 1, M. Riallot 1, H. Shen 2, W. Wang 1,2, X. Wang 2, C. Zhang.
FCAL R&D towards a prototype of very compact calorimeter
First data from TOTEM experiment at LHC
The Luminosity Monitor
Preparation of the CLAS12 First Experiment Status and Time-Line
GEANT Simulations and Track Reconstruction
Gain measurements of Chromium GEM foils
TDIS mTPC update Nilanga Liyanage and Kondo Gnanvo UVa
Presentation transcript:

Status of the Forward Elastic Scattering Luminosity Monitor Hampton University, Hampton, VA Jefferson Laboratory, Newport News, VA OLYMPUS Collaboration Meeting, DESY, April 26 – 27, 2010 Michael Kohl

Electrons/positrons (100mA) in multi-GeV storage ring DORIS at DESY, Hamburg, Germany Unpolarized internal hydrogen target (buffer system) 3x10 15 at/cm 100 mA → L = 2x10 33 / (cm 2 s) Large acceptance detector for e-p in coincidence BLAST detector from MIT-Bates available Measure ratio of positron-proton to electron-proton unpolarized elastic scattering to 1% stat.+sys. Redundant monitoring of (relative) luminosity (ratios) to ~1% per hour Proposed Experiment

Moller/Bhabha scattering degrees for symmetric Moller setup - requires knowledge of Moller/Bhabha cross sections Monitoring the Luminosities Pressure, temperature, flow, current measurements - limited in precision Small-angle elastic scattering - high count rate, no TPE at high epsilon / low Q 2 - single-arm and in coincidence with recoil proton - event-by-event with full track reconstruction - different acceptances for e + and e - - requires knowledge of angular xsec. dependence

Luminosity monitors for lepton in coincidence with recoil proton detected in the opposite sector ~12 o Luminosity Monitors: GEM Telescopes 2 forward tGEM telescopes, 1.2msr, 12 o, R=187/237/287cm, dR=50cm, 3 tracking planes Proposed version included in OLYMPUS TDR Sept TOF

Luminosity Monitors: GEM+MWPC Concept paper for TDR, Sec. 4 sent out to OLYMPUS collab. Two MWPC telescopes with 3 x/u/v elements after each GEM element Scintillator for triggering and timing High redundancy No interference Two independent groups Well suited for efficiency and alignment calibration Both GEM and MWPC telescopes can operate independently

Luminosity Monitors: GEM+MWPC Concept paper for TDR, Sec. 4 sent out to OLYMPUS collaboration Each system alone is not deteriorated too much by the other Both systems combined give superior resolution

MWPC: Confined space … but they fit 0-degree view12 degrees19.45 degrees Toroid coils Wire chambers Readout Backplanes MWPC MWPC closest to target at 200 cm

Luminosity Monitors – Basic Properties Two symmetric GEM telescopes at 12 o Two-photon effect negligible at high-ε / low-Q 2 Sub-percent (relative) luminosity measurement per hour at 2.0 GeV, per day at 4.5 GeV 1.2 msr = 10 x 10 cm 2 at ~290 cm distance (rearmost plane) Three GEM layers with ~0.1 mm resolution with ~50 cm gaps → Match vertex resolution (z) of ~ 0.1 – 1 cm at 12 o with proton in BLAST Issue of acceptance loss and different average angle due to track bending can be alleviated with reduced toroid field Proposed version included in OLYMPUS TDR Sept. 2009

Luminosity Monitor based on GEMs Forward-angle electron/positron telescopes with good angular and vertex resolution Two telescopes with 3 triple-GEM detectors, left-right symmetric Coincidence with proton in opposite sector of main detector Single-arm tracks High rate capability Readout based on APV chip MIT protoype: Telescope of 3 Triple GEM prototypes (10 x 10 cm 2 ) using TechEtch foils F. Simon et al., NIM A598 (2009) 432

Providing GEM detectors Collaboration HU-MIT-Rome –TechEtch/MIT to provide GEM foils –Assembly of detectors at MIT and MIT-Bates –Rome: Readout system developed for Hall A / SBS –Testing at HU / HUPTI / Jlab / J-PARC or DESY Funding –Secured NSF Nuclear Physics/ARRA basic research grant ($405k) postdoc + travel; 1 graduate student supported by HU NSF group 2 undergraduate stipends for summer 2010 –Secured $216k within NSF MRI-R2 for luminosity monitors ($125k), 1 graduate stipend + travel for commissioning

Tasks & Timeline for LuMo Construction Assembly of GEM detectors at MIT in summer 2010 New research building at HU with lab space available by summer Central supply of (non-flammable) gases -Clean room on HU campus from ATLAS group available if necessary

Realization of Detectors Construction project fully funded (NSF, MRI-R2), grants are active Postdoc position possibly filled by J. Diefenbach eff. July 1, 2010 Purchase of GEM and HV foils initiated, designed by D. Hasell, 5-6 weeks delivery (early June) HU-MIT Research Agreement in preparation to enable Bates engineering services: –Drawings, direct ordering of parts, technical support for manufacturing –Parts to be available by June/July HU group to visit MIT and Bates from June 7 – August 8, 2010 –Two HU undergraduate students (Miles Campbell, Joshua McMahon) –One HU graduate student (Ozgur Ates); one postdoc (J.D., t.b.c.); and M.K. –Gluing and testing of GEM foils (Optical checks; HV conditioning) –Assembly of GEM detectors at MIT Bates –Some initial testing Have detectors constructed by August, transfer to HU

Realization of Detectors (cont’d) Prepare cosmic ray test stand at HU –Collaboration with M.E. Christy (HU) –Scintillators, eventually with SOS wire chambers for good track definition Implement test readout in August 2010 (Rome group) –New APV based system if ready –“Gassiplex” system (Jlab) as fallback for cosmic ray and source tests Testing with cosmic rays / sources from August – October 2010 –Signal to noise studies, cluster performance –Study gains and charge sharing –Operation stability, discharges –Efficiency versus voltage –Efficiency distributions versus x and y –Spatial resolution

Realization of Detectors (cont’d) Testing with beam between October 2010 – January 2011 –HUPTI / 100 MeV protons with low intensity (initial proton track may be known) –Jlab / Qweak – parasitically (scatt. electron tracks known if comb. w. Qweak) –Kaon 1.1BR commissioning at J-PARC (Oct-Nov. 2010) –DESY testbeam (tracks well known) –Or no separate beam testing at all? – Decide by August Transfer detectors to DESY between Oct and Jan Mount GEMs in DORIS in Feb for spring test run Final installation in OLYMPUS in summer 2011

GEM Design Criteria / Issues Want 12.5x12.5 cm 2 total area – gluing instead of bolting w/ O-rings Identical design for all chambers preferred – easy replacements Can use inner frame design of new MIT prototype (D. Hasell) with minor modifications (like glue troughs), for everything but readout Use top and bottom spacer frames for gas pressure foils Access all infrastructure items – voltage supply, gas connectors, readout connectors through top frame margin

GEM Detector Design (MIT)

GEM Readout Board Readout pitch of MIT prototype: 635 (800)  m, COMPASS: 400  m Number of electronics channels per chamber: [ ]/0.635(0.800,0.400) ~= 315 (250, 500), read out by 3(2, 4) APV chips Want 12.5x12.5 cm 2 total area Issue to be decided fast: Readout board design -CERN design (R. de Oliveira), based on laser ablation technique, “standard” size too large (>18x18). Is used by INFN&UVA at PREX -CERN can produce any other design based on Gerber file -Laser ablation MIT (Compunetics) discontinued -Readout with strips and pads vias-connected on rear side -Is currently still in R&D phase -Existing design for 10x10 cm 2 with 800 μm pitch

Strips & Pads Readout (D. Hasell) 800 μm pitch - Total view

Strips & Pads Readout (D. Hasell) 800 μm pitch - Bottom side (aspect)

Strips & Pads Readout (D. Hasell) 800 μm pitch - Top side (aspect)

Strips & Pads Readout (D. Hasell) 800 μm pitch - Top+bottom sides (aspect)

Strips & Pads Readout (D. Hasell) 800 μm pitch - Total view

Readout Electronics 23 GEM  FEC  ADC+VME Controller  DAQ 2D Readout Up to 10 m 80 mm 49.5 mm 8 mm Frontend card (APV + VME) by INFN Rome  see next talk, by S. Frullani First test of 10x10 GEMs from INFN and UVa at PREX/Hall A in March 2010 Second test, with new APV readout toward end of PREX in May 2010 System to become available for OLYMPUS GEMs in August 2010

Backup slides

Luminosity Monitor MC Tasks Continue to work on GEANT4 simulation (Ozgur Ates, HU graduate student of HU nuclear physics group) –use new, faster codes with better bookkeeping features –higher MC statistics Simulations of phase space integral(s) (acceptance) expected counts, acceptance-averaged cross section Study of systematic effects (beam offset, slope, width; etc.) on counts per bin Simulation of backgrounds (Moller/Bhabha; Inelastics)

Luminosity Monitors: Cost estimate Proposed version included in OLYMPUS TDR Sept. 2009