© R. Ambrósio Jr, MD, PhD - 2011 R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group Corneal Biomechanical Assessment using.

Slides:



Advertisements
Similar presentations
Keratoconus Research Innovation at CERA Dr Srujana Sahebjada Research Fellow, Optometrist Ocular Genetics Unit.
Advertisements

Asymmetric Keratoconus Study: Novel Tomographic Parameters to enhance sensitivity to detect abnormalities in eyes with normal axial curvature maps from.
Biomechanical Properties of the Cornea in Normal- Tension Glaucoma Authors: Leonidas Traipe Ines Cayuqueo Fabiola Cerfogli Claudia Goya Allister Gibbons.
Statement of Commercial Interest: RDJ: None DRH: honoraria from Reichert for educational lectures on corneal biomechanics Multiple studies have shown ex.
Corneal biomechanical properties and their association with intraocular pressure (IOP) and central corneal thickness (CCT) Dimitrios P. Bessinis 1, Pandelis.
Swept Source Optical Coherence Tomography for Evaluation of Posterior Corneal Changes after Refractive Surgery Dr. Tommy Chung Yan Chan Dr. Vishal Jhanji.
Two dimensional elasticity mapping of partially cross-linked rabbit corneas using optical coherence elastography Jiasong Li 1, Manmohan Singh 1, Srilatha.
Recent Advances in IOP measurements
Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.
Biomechanical Properties of Healthy and Keratoconic Corneas Evaluated Using an Ultra-High-Speed Scheimpflug Camera nznec Department of Ophthalmology University.
Corneal Biomechanics, Pachymetric Progression Profile and Corneal Volume: Indices for Detecting Ectasia and Screening Refractive Candidates Renato Ambrósio.
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group Comparative Study of Corneal Biomechanical Properties.
Purpose We studied the interdevice agreement of three systems in the different measurements of the corneal and anterior segment biometric parameters. The.
Correlation between Preoperative cataract grading by Scheimpflug imaging and phaco time and power US in phacoemulsification. Bruno Valbon; Ana Canedo;
INTRAOPERATIVE FLAP COMPLICATIONS IN LASIK SURGERY PERFORMED BY OPHTHALMOLOGY RESIDENTS IN TRAINING Arturo Gómez-Bastar MD Arturo Ramirez-MirandaMD Lorena.
Anterior Chamber Depth, Iridocorneal Angle Width, and Intraocular Pressure Changes After Phacoemulsification: Narrow vs Open Iridocorneal Angles Huang.
Application of Quantitative Method for Prospectively Identifying Risk for Ectasia After LASIK in Normal, Suspect, and Ectatic Eyes Mujtaba A. Qazi, MD.
David Zadok MD, Isaac Avni MD
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group The impact of reference body selection for calculating.
Outcome of refractive surgery in keratoconus suspect eyes
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. David Zadok, MD, Yakov Goldich, MD, Yaniv Barkana,
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
Dept. of Ophthalmology, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany. Outcome after big-bubble deep anterior lamellar keratoplasty.
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
Glaucoma Screening With a New Non-Contact Air Impulse Tonometer Pandelis A. Papadopoulos,1,2, Dimitrios P. Bessinis 3, Alexandros A. Papadopoulos 1, Konstantinos.
Relationship between Pachymetry and Ocular Response Analyzer Measurements Alejandro Rivera MD.
Conductive Keratoplasty (CK) Insert name/ Practice name/ Logo here if desired.
Assessment of wave propagation in mice cornea and lens using phase stabilized swept source optical coherence tomography Ravi K. Manapuram, Floredes M.
SK Kwok, MD Hong Kong Laser Eye Centre, Hong Kong The author has no financial interest in the subject matter of this e-poster ASCRS 2011 San Diego, US.
ROTATING SCHEIMPFLUG TOPOGRAPHIC PARAMETERS IMPORTANT IN DISTINGUISHING NORMAL FROM KERATOCONIC CORNEAL MORPHOLOGICAL FEATURES Clayton Falknor, MD, Orkun.
Evaluation of Long-Term Keratoconus Progression Using Scanning-Slit Topography First Author: David Galarreta, MD Contributing Authors: Nestor Cortes, MD,
Khairidzan Mohd Kamal MD
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. Yakov Goldich, MD, David Zadok MD, Yaniv Barkana,
Rio de Janeiro Corneal Tomography and Biomechanics Study Group Dr. Ambrósio is consultant for Oculus Optikgeräte GmbH (Wetzlar, Germany) Agreement of Artificial.
M. Vokrojova MD, M. Vokrojova MD, D. Sivekova MD, L. Wagnerova MD D. Sivekova MD, L. Wagnerova MD Prof. P. Kuchynka MD, PhD Prof. P. Kuchynka MD, PhD The.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
Naomi R. Goldberg, MD PhD Kenneth J. Wolf, MD Eric J. Wolf, MD FACS The authors have no financial interest in the subject matter of this poster. Comparison.
*Kagithane State Hospital,Department of Ophthalmology,Istanbul, Turkey DR.GÖKHAN KAYA *Kagithane State Hospital,Department of Ophthalmology, No author.
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group The study of the correlations of the optic disc size with Cornal Geometry and Biomechanical.
Rio de Janeiro Corneal Tomography and Biomechanics Study Group CORNEAL TOMOGRAPHY AND BIOMECHANICAL FINDINGS OF CONCOMITANT KERATOCONUS AND CORNEAL GUTTATA.
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group e-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group Clinical.
Evaluation of Corneal Tomography in Primary Pterygium Sahil Goel, MD (Presenting Author), Murugesan Vanathi MD *The authors have no financial interests.
Ahmed El-Massry, M.D. Professor of Ophthalmology - Faculty of Medicine University of Alexandria Egypt long-Term Results of Corneal Biomechanical Changes.
Escaf M; Izquierdo Jr L; Mendoza J; Miranda M Instituto de Ojos Oftalmo Salud Lima, Peru THERE IS NO FINANCIAL INTEREST IN THIS POSTER.
M. Escaf, J. Mendoza, L. Izquierdo jr., M. Henriquez Instituto de Ojos Oftalmo Salud Lima, Peru There is no financial interest in this poster.
The latest from the Australian Study of Keratoconus Dr Srujana Sahebjada Postdoctoral Research Fellow/Optometrist Ocular Genetics Unit.
Ocular Response Analyzer Waveform Analysis in the Ectatic Corneas: Correlation of the New Corneal Biomechanics Parameters and Severity of Keratoconus Kristin.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Comparative biomechanical analysis of combined treatments for keratoconus M. A. del Buey 1, E. Lanchares 2, J. A. Cristóbal 1, B. Calvo 2, M. Doblaré 2.
Rio de Janeiro Corneal Tomography and Biomechanics Study Group CONCOMITANT KERATOCONUS AND FUCHS DYSTROPHY: TWO DISEASES IS BETTER THAN JUST ONE? Dr. Ambrósio.
Corneal Hysteresis Role of Corneal Biomechanics in Refractive Surgery Luis Rodriguez, MD Anny Villegas, MD Clínica de Córnea Centro Médico Docente La Trinidad.
Mathematical Description of the Ocular Response Analyzer Applanation Signal in Post-LASIK Ectasia Mujtaba A. Qazi, M.D. 1,2 David A. Luce, Ph.D. 3 Jay.
BIOMECHANICAL PROPERTIES OF THE CORNEA IN PSEUDO-EXFOLIATION SYNDROME Aylin Kılıç Ertan, MD Özgür Bilen, MD Kudret Eye Hospital, Ankara, Turkey There is.
Corneal Biomechanical Changes Following Surface Keratorefractive Surgery Teeravee Hongyok, MD, Christopher J. Rapuano, MD, Ajoy Virdi, MBBS, Elisabeth.
Poster# P36 Comparison of Techniques of Measuring Anterior Chamber Depth and Corneal Curvature in Indian Eyes Sujata Das, MS, FRCS Anjula Kumari, B.Optom.
CORNEAL ENDOTHELIAL PROFILE AFTER FERRARA RING IMPLANTATION Leonardo Torquetti, MD, PhD Paulo Ferrara, MD, PhD Paulo Ferrara Eye Clinic Belo Horizonte.
CRF variations ( initial CRF – final CRF )
CORNEAL EPITHELIAL IMAGING
LSU Eye Center, New Orleans, LA
Comparison of Single-Scheimpflug and Dual-Scheimpflug Pachymetry Measurements and Effect of Decentration World Cornea Congress VI April 7-9, 2010.
LASIK vs ASA Case Studies
Mehdi Ghajarnia, MD Mark Mifflin, MD John A. Moran Eye Center
Effects of corneal collagen crosslinking on Ocular Response Analyzer waveform-derived variables in keratoconus and post-LASIK ectasia Spatial treatment.
Three-Year Follow-up after LASIK in Eye with Extremely Thin Corneal Bed Hidemasa Torii, MD, Kazuno Negishi, MD, Murat Dogru, MD, Takefumi Yamaguchi, MD,
Vicente J. Correa-Gomez MD, Guillermo Tapia MD, Oscar Macias Manuel MD, Alejandro Navas Perez MD, Gilberto Islas MD, Tito Ramírez-Luquin MD, Enrique O.
Federal University of São Paulo, Brazil
Bruno Valbon, Ana Caiado, Ricardo Louzada, Renato Ambrosio Jr *.
Corneal Biomechanical Assessment using Dynamic Ultra High-Speed (UHS)
Yakov Goldich MD,Yaniv Barkana MD, Isaac Avni MD, David Zadok MD,
Hyuck Jin Choi, Joo Youn Oh, Won Ryang Wee, Mee Kum Kim,
Presentation transcript:

© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group Corneal Biomechanical Assessment using Dynamic Ultra High-Speed Scheimpflug Technology Non-Contact Tonometry (UHS-ST NCT): Preliminary Results Renato Ambrósio Jr., MD, PhD* Diogo L. Caldas, MD Isaac C. Ramos, MD Rodrigo T. Santos, MD Leonardo N. Pimentel, MD Cynthia Roberts, PhD* Michael W. Belin, MD* Dr. Ambrósio & Dr. Belin are consultants for Oculus Optikgeräte GmbH (Wetzlar, Germany) and have received research funding and travel reimbursements

© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group Introduction: Evolution on Corneal Propedeutics “Propedeutics” refers (in Medicine) to the collection of data about a patient by observations and examinations. Advances are recognized on the ability for architecture or goemetrical characterization of the cornea Keratometry, Keratoscopy, Videokeratography, Corneal Topography, Corneal Tomography

© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group Corneal Biomechanics: Relevance From Geometrical and Optical understanding, the next step is biological evaluation: healing response and biomechanics Ectasia mysteries* in Refractive Surgery had highlight the need for corneal biomechanical understanding (*ie: cases with no risk factors that develop ectasia after LASIK) Also to Customize Refractive Corneal Treatments; correctly measure IOP (intraocular pressure) and to possibly predict glaucoma risk Corneal biomechanical evaluations were limited to in vitro studies and to mathematical finite element models until the Ocular Response Analyzer (ORA-Reichert, Depew) in 2005 New techniques are under development for evaluating biomechanics This e-Poster presents a new system – The Corvis ST (Oculus, Wetzlar, Germany) with preliminary clinical results.

© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group Ultra High-Speed (UHS ST) Scheimpflug Technology takes 4,330 frames/sec with 8mm horizontal coverage Monitors corneal deformation response to a symmetrically metered air pulse The Oculus Corvis ST 1. Natural; (Ingoing Phase) 2. First Applanation (1st A) Momentum; 3 and 4. Ingoing Concavity Phase; 5. Highest Concavity Momentum; 6. Oscillation Period; (Outgoing Phase); 7. Second Applanation (2nd A) Momentum; 8. After Second Applanation; 9. Natural Back 1 st Applanation, Highest Concavity and 2 nd Applanation: Time and Length; Maximum Deformation; Maximum Velocity In and Out; Thickness

© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group Corvis ST: First Studies Experiment involving contact lenses mounted on an artifical pressurized chamber (Caldas et al., ePoster ASCRS 2011) found that the deformation response is influenced by lens properties and chamber pressure. (see video* PosterASCRS2011_clip_RAmbrosio). The inspection of the actual deformation process details corneal characterization, which has a potential for distinguishing normal (A, B) and keratoconus (C, D) corneas (see video* PosterASCRS2011_clip_RAmbrosio). Natural and Highest Deformation Momentum in a Normal (A, B) and a Keratoconic (C, D) Cornea

© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group Corvis ST: Clinical Parameters IOP: is the NCT measurement based on the 1 st Applanation 1st A-time: is the time from starting until the first applanation HC-time: time from starting until Highest Concavity is reached 2nd A-time: time from starting until the second applanation 1st A length: cord length of the first applanation 2nd A length: cord length of the second applanation Def Amp: maximum amplitude at the apex (highest concavity) W-Dist: distance of the two “knee’s” at highest concavity (HC) Curvature Rad HC: central concave curvature at HC Curvature Rad normal: initial central convex curvature Vin: corneal speed during the first applanation moment Vout: corneal speed during the second applanation moment

© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group The Corvis ST was utilized to assess corneal deformation response in one eye from 71 keratoconic patients and in one eye from 178 normal patients. Clinical diagnosis was based on the complete eye exam, Placido- disk based corneal topography and Pentacam Corneal Tomography. Clinical Study Wilcoon Rank Sum (Mann- Whitney Test) IOP:< st A Time:< nd A Time: st A Length(max): nd A Length(max): Curv. Rad. Normal: Curv. Rad. HC:< Pachy Apex:< W-Dist.: Def.Amp.(max):< Vin:< Vout: Statistically significant distributions for all parameters (Mann- Whitney, p<0.05), but with significant overlap and AUC (area under the ROC curves) between and 0.852

© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group Corvis Combo1: combined parameter Joint work with “Instituto de Computação” at UFAL (Universidade Federal de Alagoas*) to develop a combined parameter (Corvis Combo1) based on a linear regression analysis, considering the effects of IOP on deformation response parameters * IOP * Pachy Apex * 1st A Time * HC Time * 2nd A Time * 1st A Length(max) * 2nd A Length(max) * Def Amp (max) * W-Dist * Curv, Rad, HC * Curv, Rad, Normal * Vin * Vout NKC Ave-0,008010, SD0, ,26691 * Prof. Aydano P. Machado & J. M. Lyra, MD, PhD

© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group AUCSE a95% CI b 1st_A_Time_ 0,8020,03130,747 to 0,850 Def_Amp__max__0,7490,03550,691 to 0,802 Pachy_Apex_0,8520,02650,801 to 0,893 Curv__Rad__HC_0,8520,02900,802 to 0,894 Curv__Rad__Normal_0,8100,03290,755 to 0,857 CorvisST Combo10,9310,01910,892 to 0,959 a DeLong et al., 1988 b Binomial exact The Corvis ST Combo1 performed statistically better (p<0.05; Pairwise ROC comparisons) than the individual parameters from the Corvis ST to distinguish 71 keratoconic eyes and 178 normal eyes (one eye per patient included) This approach has been complementary to enhance the diagnosis of ectasia susceptibility. Clinical Study

© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group There were very significant correlations (Spearman, p<0.001) between IOP and 1 st Applanation Time (rho=0.94), 2 nd Applanation Time (rho=-0.73), Deformation Amplitude (rho=-0.80), W-Dist (rho=-0.66), Curv Rad HC (rho=0.45), Vin (rho=-0.49), Vout (0.38) and Combo1 (rho=-0.44) There were significant correlations (Spearman, p<0.01) between Pachymetry at the Apex and IOP (rho=0.37), 1 st Applanation Time (rho=0.4) and Lengh (rho=-0.18 ), W-Dist (rho=-0.25), Curv Rad HC (rho=0.48), Vout (rho=0.3), and Combo1 (rho=-0.64) There was a positive correlation between age and HC Time (Spearman, p=0.0039; rho=0.22) Clinical Correlations

© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group Enhanced Screening for Ectasia Susceptibility Biomechanical data from Corvis ST enhances the capability to detect very mild cases of ectasia and also help to characterize stable cases with asymmetric bow tie and inferior steepening (ABT/IS). Biomechanical data from Corvis ST enhances the capability to detect very mild cases of ectasia and also help to characterize stable cases with asymmetric bow tie and inferior steepening (ABT/IS). 26 eyes diagnosed as Forme Fruste Keratoconus (FFKC), with normal front curvature map while the fellow eye has keratoconus were examined. 26 eyes diagnosed as Forme Fruste Keratoconus (FFKC), with normal front curvature map while the fellow eye has keratoconus were examined. 25 eyes with ABT/IS but with no other clinical or tomographic sign of ectasia were examined. 25 eyes with ABT/IS but with no other clinical or tomographic sign of ectasia were examined. Combo1 24/178 (13%) normal eyes >0.21 9/71 (13%) keratoconic eyes < /26 (80%) eyes with FFKC >0.21 8/25 (32%) ABT/IS cases >0.21 Kruskall-Wallis Test NormalKCFFKCABT/IS Normal <0.05 NS KC NS<0.05 FFKC <0.05 NFFK1KCABT Ave-0,008010, , , SD0, , ,266910, see video* PosterASCRS2011_clip_RAmbrosio

© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group Combo 1=0.16 Combo 1=0.31 The inspection of corneal deformation during NCT enables biomechanical characterization The deformation is severely influenced by IOP Combo1 from Corvis ST provides clinically relevant parameter to enhance sensitivity and specificity to detect ectasia. Corvis ST: Conclusions ABT with no Ectasia (A,B) x FFKC (C, D) This approach is complementary to Corneal Tomography with the Pentacam for screening refractive candidates