New Readout Methods for LAr detectors P. Otyugova 20.10.2006 ETH Zurich, Telichenphysik CHIPP Workshop on Neutrino physics.

Slides:



Advertisements
Similar presentations
First observation of electroluminescence in liquid xenon within THGEM holes: towards novel Liquid Hole-Multipliers L. Arazi, A. Breskin, A. Coimbra*,
Advertisements

Electronics for large LAr TPC’s F. Pietropaolo (ICARUS Collaboration) CRYODET Workshop LNGS, March 2006.
TPC Proposal for the 35 Ton Liquid Argon Test Abstract We propose to equip the 35 ton cryostat with one APA and two CPA’s, and all the necessary equipment.
LBNE 35 ton prototype Phase 1 summary Terry Tope Fermi National Accelerator Laboratory All Experimenters’ Meeting – Fermilab – May 19, 2014.
I.Kreslo CHIPP workshop on Detector R&D, University of Geneva, June Development of Liquid Nitrogen Time Projection Chambers A. Ereditato,
Micro MEsh GASeous Detectors (MicroMegas)
Gas Detector Developments Jin Li. Liquid Xenon case Liquid Xenon can be considered as a gaseous xenon of 520 atm. K.Masuda, S. Takasu, T.Doke et al. (Doke.
Micromegas studies using cosmic rays Franck Sabatié May 7th 2009 Saclay cosmic ray bench Data acquisition system and analysis tools MIP detection Position.
GEM Detector Shoji Uno KEK. 2 Wire Chamber Detector for charged tracks Popular detector in the particle physics, like a Belle-CDC Simple structure using.
D. Peterson, “The Cornell/Purdue TPC”, ALCPG, Snowmass, 23-August The Cornell/Purdue TPC Information available at the web site:
Proportional Light in a Dual Phase Xenon Chamber
Characterization of the electrical response of Micromegas detectors to spark processes. J.Galan CEA-Saclay/Irfu For the RD51 meeting.
Catania VLVnT09 Athens, Greece 1/14 Catania Performances of four super bialkali large area photomultipliers with respect to.
C.Shalem et al, IEEE 2004, Rome, October 18 R. Chechik et al. ________________RICH2004_____________ Playa del Carmen, Mexico 1 Thick GEM-like multipliers:
ZEPLIN II Status & ZEPLIN IV Muzaffer Atac David Cline Youngho Seo Franco Sergiampietri Hanguo Wang ULCA ZonEd Proportional scintillation in LIquid Noble.
1 The GEM Readout Alternative for XENON Uwe Oberlack Rice University PMT Readout conversion to UV light and proportional multiplication conversion to charge.
QUPID Readout and Application in Future Noble Liquid Detectors Kevin Lung, UCLA TIPP 2011 June 11, 2011.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
Chevron / Zigzag Pad Designs for Gas Trackers
ICARUS General Trigger Design Contributions from: M.Della Pietra, A.Di Cicco, P.Di Meo, G.Fiorillo, P.Parascandolo, R.Santorelli, P.Trattino B.Baboussinov,
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
Sheffield : R. Hollingworth, D. Tovey R.A.L. : R.Luscher Development of Micromegas charge readout for two phase Xenon based Dark Matter detectors Contents:
Stanford, Mar 21, 2005P. Colas - Micromegas TPC1 Results from a Micromegas TPC Cosmic Ray Test Berkeley-Orsay-Saclay Progress Report Reminder: the Berkeley-Orsay-
TPC R&D status in Japan T. Isobe, H. Hamagaki, K. Ozawa, and M. Inuzuka Center for Nuclear Study, University of Tokyo Contents 1.Development of a prototype.
EPS-HEP 2015, Vienna. 1 Test of MPGD modules with a large prototype Time Projection Chamber Deb Sankar Bhattacharya On behalf of.
Poster Design & Printing by Genigraphics ® Neutrino Interactions Studying the properties of neutrinos will shed light on the origin of the.
Discussion: développement du système de lecture des photomultiplicateurs pour le prototype de détecteur Argon liquide de LBNO 21/11/2013 Réunion: APC,
Large TPC Workshop, Paris, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay.
Micromegas TPC Beam Test Result H.Kuroiwa (Hiroshima Univ.) Collaboration with Saclay, Orsay, Carlton, MPI, DESY, MSU, KEK, Tsukuba U, TUAT, Kogakuin U,
Experimental and Numerical studies on Bulk Micromegas SINP group in RD51 Applied Nuclear Physics Division Saha Institute of Nuclear Physics Kolkata, West.
1 Liquid Argon Dark Matter: Synergies with R&D for Neutrino Detectors: Chemically clean Argon for drifting electrons and light output (Oxygen and H20 relevant.
Argontube Detector design Laffranchi Marco, Meregaglia Anselmo, Messina Marcello, Rubbia Andre’ Bern,
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Update on the Triple GEM Detectors for Muon Tomography K. Gnanvo, M. Hohlmann, L. Grasso, A. Quintero Florida Institute of Technology, Melbourne, FL.
I. Giomataris NOSTOS a new low energy neutrino experiment Detect low energy neutrinos from a tritium source using a spherical gaseous TPC Study neutrino.
R&D on LAr TPCs for neutrino, proton decay and DM experiments Presented by A. Marchionni, ETH Zurich CHIPP Annual Plenary Meeting, Sept  GLACIER:
Catania 11 ICATPP october, 2009 Como 1/12 Catania Comparative measurements of the performances of four super bialkali large.
November 4, 2004Carl Bromberg, FNAL LAr Exp. Workshop Nov. 4-6, Liquid argon as an active medium Carl Bromberg Michigan State University & Fermilab.
2002 LHC days in Split Sandra Horvat 08 – 12 October, Ruđer Bošković Institute, Zagreb Max-Planck-Institute for Physics, Munich Potential is here...
Quality control for large volume production GEM detectors Christopher Armaingaud On behalf of the collaboration GEMs for CMS.
Preliminary results on Copper filters, with FLIC test chamber F. Pietropaolo, A. Zani, M. Meli CENF General Meeting – 22/10/2015.
1 Two-phase Ar avalanche detectors based on GEMs A. Bondar, A. Buzulutskov, A. Grebenuk, D. Pavlyuchenko, Y. Tikhonov Budker Institute of Nuclear Physics,
Construction and Characterization of a GEM G.Bencivenni, LNF-INFN The lesson is divided in two main parts: 1 - construction of a GEM detector (Marco Pistilli)
Study of gas mixture containing SF6 for the OPERA RPCs A.Paoloni, A. Mengucci (LNF)
1 A two-phase Ar avalanche detector with CsI photocathode: first results A. Bondar, A. Buzulutskov, A. Grebenuk, D. Pavlyuchenko, R. Snopkov, Y. Tikhonov.
Single GEM Measurement Matteo Alfonsi,Gabriele Croci and Bat-El Pinchasik June 25 th 2008 GDD Meeting 1.
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
The ModuLAr Project LoI discussion INFN-LNL 21/11/2007 Legnaro (PD)
Thorsten Lux. Charged particles X-ray (UV) Photons Cathode Anode Amplification Provides: xy position Energy (z position) e- CsI coating 2 Gas (Mixture)
Andrey Sokolov Novosibirsk State University (NSU) Budker Institute of Nuclear Physics (Budker INP) Novosibirsk, Russia Two-phase Cryogenic Avalanche Detector.
Study of the cryogenic THGEM-GPM for the readout of scintillation light from liquid argon Xie Wenqing( 谢文庆 ), Fu Yidong( 付逸冬 ), Li Yulan( 李玉兰 ) Department.
Fred Hartjes 1 RD51 mini week, CERN, June 14, 2012 Implementing GridPix in a Darwin detector Matteo Alfonsi, Niels van Bakel, Patrick Decowski, Harry van.
R&D activities on a double phase pure Argon THGEM-TPC A. Badertscher, A. Curioni, L. Knecht, D. Lussi, A. Marchionni, G. Natterer, P. Otiougova, F. Resnati,
Budker INP V.Aulchenko1,2, L.Shekhtman1,2, V.Zhulanov1,2
First operation of a double phase pure liquid Argon THGEM-TPC
Results achieved so far to improve the RPC rate capability
UK Dark Matter Collaboration
A. Badertscher, L. Knecht, D. Lussi, A. Marchionni, G. Natterer, P
THGEM: Introduction to discussion on UV-detector parameters for RICH
Numerical simulations on single mask conical GEMs
Numerical simulations on single mask conical GEMs
New Study for SiPMs Performance in High Electric Field Environment
LAr detector R&D in Japan
Development of Gas Electron Multiplier Detectors for Muon Tomography
MWPC’s, GEM’s or Micromegas for AD transfer and experimental lines
(On Behalf of CMS Muon Group)
Gain measurements of Chromium GEM foils
A DLC μRWELL with 2-D Readout
E. Erdal(1), L. Arazi(2), A. Breskin(1), S. Shchemelinin(1), A
Presentation transcript:

New Readout Methods for LAr detectors P. Otyugova ETH Zurich, Telichenphysik CHIPP Workshop on Neutrino physics

Liquid Argon TPCs detect the ionization charge to create the image of the event and the scintillation light can be used for triggering or T 0 definition. To detect the ionization charge in a large noble liquid detector very low noise charge preamplifier is required (challenging, costly). For example: in ICARUS detector the signal is only electrons for a minimum ionizing particle track with 3mm wire pitch. In this case to obtain a high signal to noise ratio the equivalent noise charge has to be less then 1000 electrons. Signal from a MIP recorded In the Induction plane of T600 ICARUS detector. In 100 kton detector with 20 m drift In a field 1kV/cm the drift time is about 10 ms. With a 2 ms electron lifetime, the 6000 electron/mm signal is attenuated by: It is too low for a readout as in ICARUS (See talk of A.Rubbia)

How can we solve this problem? To compensate the attenuation and to improve signal-to noise ratio one can introduce a so-called double-phase amplification and readout. e-e- Ampl. + readout race track electrodes Liquid Ar Gas Ar Extraction grid In this type of readout the electrons are extracted from the liquid by a grid into the gas phase where they are amplified and read out by a gas multiplier technique. =3mm- the spread from the diffusion on 20m drift distance. It gives a limit on a readout granularity. References on a Double Phase detection method: Experimental Methods for Particle Dark Matter Detection. Dolgoshein et al., Fiz.El.Chast. Atom. Yad. 4 (1973) 167

Different types of gas avalanche detectors can be proposed for a charge readout: GEM, T-GEM, LEM, MicroMEGAS,... We are working on the R&D of a Large Electron Multiplier (LEM) made out of standard PCB technique. This method potentially provides a several benefits: 1. Possibility to reach electron amplification gain up to Improvement of signal to noise ratio which results in a possibility to detect events with a lower energy threshold or long drift paths. 3. Low cost and relatively easy mode of operation. For Dark Matter applications, this method potentially provides additional benefits: 1. Improvement of position resolution as compared to PMT readout. 2. Possibility to use very low background materials. 3. Takes less space than PMTs.

What is the LEM? Diameter of the hole: 500 microns. Distance between two holes: 800 microns. LEM thickness: 1.5mm. For HV supply both surfaces are covered with copper electrodes. LEM is a thick macroscopic GEM

For obtaining a necessary gain a double-stage LEM system is required. Multiplication factor (average gain) ~10 4. The simulation is made for 100% Ar gas at temperature T=87K and pressure1bar.

The detector will consist of 2 LEM stages with 3mm separation Image of the hole is made with magnification x500. Edge of the hole seems to be smooth. It helps us to avoid the corona discharges which can be caused by the sharp and not uniform edges.

Experimental setup Tests of a single-stage LEM at room temperature

The tests LEMs of 3 different thickness were tested: 2.4mm, 1.6mm, 1.0mm 2 radioactive sources were used Fe 55 (5.8keV X-rays), Cd 109 (22keV X-rays) The tests were made in a pressure range from 1bar to 3.54bar. The value of the drift field was ~ 100V/cm which according to the simulation provides a 100% transparency for the drifting electrons

The typical spectrum (Fe 55 )

Gain curves for 3 types of the LEM obtained with Fe 55 source

The experimental setup Tests of double-stage setup

Double-stage LEM system under construction. Before the tests chamber was evacuated down to a pressure of 2*10 -4 mbar. Tests of this setup were performed in a wide range of pressures and temperatures and now it is prepared to be tested in double- phase conditions.

The High Voltage system for the LEM setup The setup is supplied through the voltage divider: R01=R02=100MOhm R11=R12=500MOhm R21=R22=100MOhm

The setup inside the container

Shapes of the signals from double-stage LEM system on the output of the preamplifier and 50 Ohm input of the oscilloscope. The average signal rise time is about 12  s. These are signals from Fe 55 radioactive source (5.8 keV), event rate is about 1kHz.

Gain curves at atmospheric pressure and room temperature Transfer field: E transf =360V/cm

Tests in gas at cryogenic temperatures

Here you can see a plot which illustrates a shift of gain curves with temperature changes. Nitrogen boiling point: 77K Argon boiling point: 87K

E (V/cm)

Preparation for the double-phase test To make these tests we have to modify our setup.

The invar-plates levelmeter is used to monitor the liquid level in the setup.

Prototype Stripped LEM readout Here is the schematic view of a LEM prototype with strips. The prototype which we are going to test soon contains 10 strips on each electrode. Strips on both sides of the PCB are perpendicular.

Design of a final LEM readout for ArDM Experiment Number of channels-1024

Full scale measurement of long drift (5 m), signal attenuation and multiplication Simulate ‘very long’ drift (10-20 m) by reduced E field & LAr purity High voltage test (up to 500 kV) Measurement Rayleigh scatt. length and attenuation length vs purity Design & assembly: completed: external dewar, detector container in progress: inner detector, readout system, … e- readout race tracks Flange with feedthroughs LAr Gas Ar grid 8” PMT ET 9357FLA Extraction from LAr to GAr and LEM readout Field shaping electrodes 8” PMT ET 9357FLA Extraction from LAr to GAr and LEM readout Field shaping electrodes ARGONTUBE

Field shaping rings (10mm spaced) Greinacher chain LEM Bottom view Top view Light pulse source Inner detector design

Outlook 1.Switching to a double-phase technique gives us a possibility to solve a problem of signal-to-noise ratio and signal attenuation in large cryogenic detectors. 2.It is planned to use LEM in many double-phase cryogenic detector projects: ArDM, GLACIER, ARGONTUBE. 3. The preliminary tests showed us, that the multi-stage LEM provides gain of 10 4 in pure Ar gas at a pressure of 1bar and a temperature of 90K. 4. Gain curves shifts correlated with the temperature changes can be explained with the fact that the gas density increases with decrease of the temperature. 5. For the moment we are already prepared to start a double-phase test of our setup.