Responsive Drug Delivery System

Slides:



Advertisements
Similar presentations
Pharmacology for Anesthesia I Introduction. What is a Drug?
Advertisements

1-800-DIABETES DIABETES CARE TASKS AT SCHOOL: What Key Personnel Need to Know DIABETES CARE TASKS AT SCHOOL: What Key Personnel Need to.
Lactate Sensor Design: Smart Gels for Diabetes Pre-screening Toby Li, Wern Ong, Joseph Sun, Stephanie Wu & Christine Zhang Advisors: Franz Baudenbacher,
Dr. Marc Madou Class IV. Microfabrication of electrochemical sensors Winter 2011 BIOMEMS.
Dr. Marc Madou, UCI, Winter 2012 Class V Potentiometric and Amperometric Sensors (I) Electrochemistry MAE-295.
Fall 2014, Prof. JB Lee Ion Sensitive FET (ISFET) - What and Why?
Public Health Issues Related to Mutually Conforming Labeling: CDRH Perspective Miriam C. Provost, Ph.D. Office of Device Evaluation Center for Devices.
A PRESENTATION ON ELECTRONIC NOSE PRESENTED BY vivek gangwar ELECTRONICS & COMMUNICATION.
Osmotic Pressure-Controlled Gastrointestinal Delivery System
Implants. Implants: Definition: A sterile drug delivery device for subcutaneous implantation having the ability to deliver drug at a controlled rate over.
Continuous Glucose Monitoring
Design of Health Technologies lecture 12 John Canny 10/17/05.
Implants. Implants: Definition: A sterile drug delivery device for subcutaneous implantation having the ability to deliver drug at a controlled rate over.
Diabetes Revision of protein structure and the importance of genetic engineering in the control of diabetes.
A Wireless Implantable Microsystem for Continuous Blood Glucose Monitoring Currently 200M diabetic people around the world (~ 21M in U.S. in 2002).  Expectation.
NUR HIDAYAH OMAR SITI HAJAR ABU BAKAR ALIA ZULAIKHA MOHD HANIF NUR HIDAYAH OMAR SITI HAJAR ABU BAKAR ALIA ZULAIKHA MOHD HANIF.
Pharmaceutics 2 & 3 صيدلانيات 2&3 Unit / second semester Transdermal drug delivery system.
BGM’s 1. Introduction  An estimated 135 million people worldwide — 18.2 million in the United States — have diabetes mellitus:  a disease in which the.
Electrochemical Glucometers
Helping Belton ISD Students Succeed What Every BISD Staff Needs to Know About: Helping Belton ISD Students Succeed What Every BISD Staff Needs to Know.
DEPARTMENT OF NANOTECHNOLOGY
Biosensors NNIN Document: NNIN-1245 Rev: 03/2012 National Nanotechnology Infrastructure Network Copyright Georgia Institute of.
Artificial Pancreas Artificial pancreas is a device or system of integrated devices which substitutes for an endocrine pancreas. It sense the blood glucose.
Are You A Candidate For An Insulin Pump?
Plasma Glucose. Glucose Glucose (MW: ) is a very important fuel source to generate universal energy molecules (ATP). Blood glucose regulation I-
Hydrogels in Drug Delivery Rassoul Dinarvand, PhD Professor of Pharmaceutics.
Biosensors NNIN Document: NNIN-1245 Rev: 03/2012 National Nanotechnology Infrastructure Network Copyright Georgia Institute of.
Type 1 Diabetes Better Connecting the Patient, Provider and Data A Proposal to Bridge the Gaps ©Chris Beuning, Andrew Tice, Jim Martin, Kathy Culver 2011.
Doc.: IEEE Submission May 2008 Sung Dong Lee, InfopiaSlide 1 Project: IEEE P Working Group for Wireless Personal Area Networks.
THE INSULIN PUMP INNOVATIVE TECHNOLOGIES. WHAT IS AN INSULIN PUMP? Machine delivery of insulin. Most commonly for those with Type one diabetes.
Presented by: Jay Leitch. What are Glucose Biosensor?   Immobilized biological components fixed on ordinary analytical detectors   Selectively detects.
“Medicine on a Chip” Imbedded chip functions as onboard doctor. Jerrod Sandefur Mark Slavik Joel Amaro Tina Hall.
1.  Drug delivery is the method or process of administering pharmaceutical compound to achieve a therapeutic effect in humans or animals.  Most common.
Biomedical Sensors Dr. James A. Smith. What’s Important? Accuracy Operational Range Response Time Sensitivity Resolution Reproducibility.
BioSensors Yang Yang 9/28/2004. Outlines BioMEMS Enzyme-coated carbon nanotubes Microcantilever biosensor with environmentally responsive hydrogel Cantilever.
Biological Properties ISSUES TO ADDRESS... Biomaterials definition Different types of interaction between body and foreign material What are main characteristics.
Continuous Glucose Monitors
Biomaterials, Drug Delivery, Nanotechnology and Bioengineering Nicholas A. Peppas Center for Biomaterials, Drug Delivery, Bionanotechnology and Molecular.
Endocrine and Metabolic Disorders Lectures 8 I.Kuziv, MD, PhD.
DELIVERY OF PROTEINS USING BIODEGRADABLE POLYMERS Mahesh V. Chaubal Guilford Pharmaceuticals Inc. Baltimore, MD 21224
CONTACT LENS THAT INFORMS ABOUT THE BLOOD GLUCOSE LEVELS M.Abhinandana M.Pharm Quality Assurance.
INSULIN PUMPS Shelby Polk DNP, FNP-BC, CDE. 2 MANAGEMENT OF DIABETES IN SCHOOLS Exercise Legal Rights Health & Learning Nutrition Insulin Administration.
TALK DIABETES November 13, 2015 Pumping Insulin 101 Bonnie Stone-Hope RN, CDE, BA.
Commercial Use of Enzymes
What Key Personal Need To Know INSULIN ADMINISTRATION.
Biosensors Dr. Bhavesh Patel Principal
Bacterial cellulose in electrochemical films
Methods and Materials Aldehyde Synthesis: The aldehyde was synthesized by oxidation of PEG dissolved in dichloromethane with sieves and NMO. TPAP was added.
A life-changing story of invention for people with diabetes Dan Quinn 21.
 History of advancement in diabetes treatment  New technology  Features  Pros and Cons  Safety in school  Questions.
Biosensing What does it mean? How do you do it? Biosensor Definition Surface Chemistry Biology Physics Photonics etc Electrochemistry Microelectronics.
Microchips IN Health Practices
WELCOME TO THE SEMINAR ON
Electrochemistry MAE-212
Lactate Sensor Design: Smart Gels for Diabetes Pre-screening
New Innovations in Diabetes Technology
Clinical Experience of an Iontophoresis Based Glucose Measuring System
IMPLANTABLE DRUG DELIVERY SYSTEM SEMINAR ON
Microchips Biotech Technology
An overview for patients and caregivers
An Introduction to Medicinal Chemistry 3/e
New Patient-Friendly Options for Managing Insulin Dosing
Iontophoresis Vineela.U 08B21A0538 CSE.
Drug Delivery Systems Pharmaceutical technology Petra University.
BIOSENSOR.
Mean daily glucose concentration and frequency of hypoglycemia in long-term care residents with type 2 diabetes. Mean daily glucose concentration and frequency.
Chapter 2-1 Wearable Bio and Chemical Sensors
Fig. 1. Iontophoretic devices used for the delivery of cytotoxic agents to solid tumors. Iontophoretic devices used for the delivery of cytotoxic agents.
Fig. 2 Fluidic and electrical characteristics of the wireless optofluidic system. Fluidic and electrical characteristics of the wireless optofluidic system.
Structure and electrochemical function of impedimetric biosensors for bacterial detection. Structure and electrochemical function of impedimetric biosensors.
Presentation transcript:

Responsive Drug Delivery System Presenter: Bo He 12/10/03

Outline Traditional drug dosing & introduction to responsive drug delivery systems Commercially available sensors & drug delivery systems Responsive drug delivery systems under development Challenge & perspective A commercially available responsive drug delivery system – insulin pumps

Traditional Drug Dosing Medicine or injections Each person responds uniquely Noticeable symptoms are not sufficient to support timely and accurate dosing Examples- diabetes, cardiovascular disease, acute pain Controlled release – frequent exposure, side effects, tolerance Drug absorption, distribution, and metabolism can vary widely among individuals, even within the same family. It’s hard to predict when the heart stroke will happen. Unpredictable absorption of injected insulin can give you unpredictable blood sugar level.

Responsive Drug Delivery Systems Combination of Biosensors & controlled release system Revolutionized medicine by enabling individualized therapy Sense continuously to manage unpredictable condition Immediate respond with appropriate countermeasure Give the patients more flexibility and less disruption of the daily life

Example: Insulin Pumps An insulin reservoir (like a regular syringe) A small battery operated pump A computer chip for control Infusion set- a thin plastic tube to deliver insulin to the body Pump therapy A basal rate & bolus insulin Combination with Glucose sensors Reservoir and pump are incorporated in a plastic case about the size of a beeper.

The Importance of Control Programmed release controlled by microchips More flexibility & less pain Reduced the risk of side effects More than 200,000 people in the US wear insulin pumps Predictable blood sugars Flexible meal intake, go sports, no multiple shots every day.

Ideal Responsive Drug Delivery Disadvantages of available systems Not automatic, the user has to decide the dose The results are not always reliable Sensors and controlled drug delivery systems are not combined Ideal systems Sense minute amounts of marker molecules Immediate response In vivo detection and delivery Small, biocompatible, accurate and reproducible Biomolecule acting In vivo detection and delivery provides immediate response with minimal disruption to the patient’s daily life.

Type of Drug Delivery Commercially available Responsive Noninvasive reverse iontophoresis devices Implantable fusion pumps Duros implant technology controlled release Responsive Closed loop Smart polymers

Biosensors, e.g. Glucowatch Biographer: non-invasive, watch-like device that measures glucose AutoSensor: a plastic part that snaps into the Biographer and sticks to the skin. Noninvasive & automatic reading every 10 mins up to 13h

Comparison of Glucose Readings

How does Glucowatch work? Based on reverse iontophoresis A low electric current pulls glucose through the skin. Glucose is accumulated in two gel collection discs in the AutoSensor. Another electrode in the AutoSensor measures the glucose.

Enzymatic pathway Glucose oxidase catalyze oxidization of glucose in hydrogel Hydrogen peroxide reacts on the platinum electrode, providing electrons Current is proportional to glucose

Controlled-release device Affecting factors Compositions of osmotic agent Thickness of semipermeable membrane Surface area

Responsive drug delivery systems Smart polymer Antigen-antibody interaction Closed loop systems Sensing and delivery combo system

Antigen-antibody interaction smart polymers A semi-interpenetrating polyacrylamide (PAAm) hydrogel Antigen—rabbit immunoglobulin G( rabbit IgG) Antibody—goat anti-rabbit IgG (GAR IgG) Takashi Miyata et al., Nature, vol 399 ,766

Antigen-antibody interaction smart polymers Effect of free antigen concentration on the hydrogen swelling ration Antigen recognition by antigen-antibody semi-IPN hydrogel

Antigen-antibody interaction smart polymers Reversible swelling changes Antigen-responsive permeation (a model protein drug haemoglobin through a membrane fabricated from hydrogel )

Schematic of Self Regulating Responsive Therapeutic System

Challenge Commercially available systems Systems under development Expensive yet not always reliable Not automatically responsive Not completely in vivo Systems under development Short lifetime and hard to reproduce Slow response time Biocompatibility (coating) Coating Passive drug release at physiological glucose levels

References Sapna K. Deo; et al. Analytical Chem. 2003, 206A-213A. www.minimed.com www.glucowatch.com R. T. Kurnik et al. Electrochem. Soc. 1998, 145, 4119-4125 Miyata, T. et al. Nature 1999, 399, 766–769. Zhang, K.; Wu, X. Y. J. Controlled Release 2002, 80, 169–178. Tanihara, M. et al. J. Pharm. Sci. 1999, 88, 510–514. www.chiprx.com www.acs.ohio-state.edu/unit/research/archive/muscles.htm Metzger, M. et al. Diabetes Care 2002, 25, 1185–1191.

Thank You