Fire Extinguishers Rating Unlike some products, extinguishers have to be installed in public premises, and a standard form of assessment is required.

Slides:



Advertisements
Similar presentations
Portable Fire Extinguisher Safety
Advertisements

State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Portable Fire Extinguishers
Ag. Mechanics Safety. Safety Safety is being free from danger, risk, or injury. Policy is a plan. Procedure is an action.
Fire Extinguisher Training
Fire Safety & Fire Extinguisher Use
Portable Fire Extinguisher Safety Emergency Procedures.
PORTABLE FIRE EXTINGUISHER TRAINING Section Montana Department of Labor & Industry Occupational Safety and Health Training Institute.
Fire Prevention & Protection Gordon Cooper Technology Center
Postal Responsibility/Contractor responsibility 1.Serial number of fire extinguisher 2.Number found on fire extinguisher and panel 3.Date extinguisher.
1 Fire Extinguisher Safety Training. 2 Fire extinguishers are designed to put out or control small fires. A small fire, if not checked immediately, will.
Chapter 8 Portable Fire Extinguishers. Introduction Portable fire extinguishers designed to fight: –Small fires –Unusual fires –Fires that cannot be reached.
Chapter 8 Portable Fire Extinguishers. Introduction Portable fire extinguishers designed to fight: –Small fires –Unusual fires –Fires that cannot be reached.
Total Flooding Systems
The three essential ingredient for creating a fire are HEAT, AIR AND FUEL Fire triangle.
Fire Safety. The Stats Fire death statistics throughout the united states –2.1 Million Fires Reported Per Year –5,100 Average Civilian Deaths.
Means of Egress and Fire Protection. 2 Objectives Understand Alarms and Warning Devices Know the location of Exits and Exit Routes Understand the RACE.
DCC FIRE PROTECTION SYSTEMS DCC FIR 204 Fire Protection Systems Chapter 2- Portable Fire Extinguishers.
2 THEME The important thing from the point of view of fire safety is – how one interprets these properties. Thorough knowledge is essential to understand.
 Fire Extinguishers  Types of fires  Selection of Extinguishers  Extinguisher Information  Sizes  Location  Operation of an Extinguisher.
What is Fire?. A chemical reaction that involves the evolution of light and energy in sufficient amounts to be perceptible.
DCC FIRE PROTECTION SYSTEMS DCC FIR 204 Fire Protection Systems Chapter 2- Portable Fire Extinguishers.
Fire Safety & Fire Extinguisher Use. OBJECTIVES Understand the combustion process and different fire classes Understand fire extinguisher types, operating.
“Fire Extinguishers”.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Portable Fire Extinguishers Selection and Placement University Safety Council April 19, 2006 Steven G. Triebold Fire Prevention and Protection Program.
Fire Extinguisher Training Developed by HMTRI through cooperative agreement # 2U45 ES with NIEHS under the Worker Safety and Health Training Support.
Selection and Distribution of Fire Extinguishers.
Fire Extinguisher Awareness
Copyright © 2010 Delmar, Cengage Learning. ALL RIGHTS RESERVED. Unit 5 Reducing Hazards in Agricultural Mechanics.
Reducing Hazards in Agricultural Mechanics
Subpart F Fire Protection and Prevention. Major Topics The Fire Triangle Classes of Fire Types of Extinguishers Steps for Using Extinguishers NFPA 704.
Fire Safety & Fire Extinguisher Use. How Does a Fire Work? Three components Need all three components to start a fire Fire extinguishers remove one or.
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
Safety Unit II.
Fire Detection and Suppression Chapter 1 Fire Extinguishing Agents and Portable Fire Extinguishers.
SAFE WORK PRACTICES Obj
Flammable and Combustible Liquids
Occupancy Classification Under NFPA 13 Examine the proposed facility and make recommendation on the Occupancy Classification Used to classify fuel loads.
Means of Egress and Fire Protection
Safety Aspects of Agricultural Mechanics
Objective Research safety aspects of agricultural mechanics.
MY AGENDA TODAY Portable Fire Extinguishers – How to use them EFFECTIVELY and SAFELY! – On what types of fires.
Fire Extinguishers Team 6 Garrett Ellanson Jeffrey Ethier Sean Tacey.
Fire Prevention and Use of Fire Extinguishers. U.S. Fire Statistics – 2004 NFPA  A Fire Department Responds to a Fire in the U.S. Every 20 Seconds –3900.
Hazardous Materials Subpart H. Subpart H Standards Compressed Gases Acetylene Hydrogen Oxygen Nitrous Oxide Flammable.
Indiana Fire Code.
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
Means of Egress and Fire Protection. Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long.
Ag 1 Safety: Unit 2.  Reduce hazards in ag mechanics  State the three conditions necessary for combustion  Match appropriate types of fire extinguishers.
Exit Routes and Fire Protection
Safety in the Agricultural Mechanics Shop #1 Agenda Warm-up Announcements Assignment Notes Square foot per person Safety worksheet #1.
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
ME444 ENGINEERING PIPING SYSTEM DESIGN
Agricultural Safety Exploring Agricultural Sciences.
Fire Extinguisher Primer 10-4 training 10 Slides, 4 minutes.
Ag Engineering I UNIT C: SAFE WORK PRACTICES A. Safety Color Codes 1. Green – safety equipment and first aid supplies 2. Red – fire safety equipment.
Sprinkler Design FSE 221 – Fire Protection Systems
Flammable Liquids Directorate of Training and Education
Carbon Dioxide System Design
Lesson 29 Area of a Combined Figure. Get the Idea Sometimes, you need to find the area of a figure that is not a common shape. You can often do this by.
Safety Aspects of Agricultural Mechanics
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
Fire Extinguisher Training
Hearing protection in excess of ________ decibels requires protection
Fire Extinguisher Training
Portable Fire Extinguisher Training
Fire/Life Safety Means of Egress Fire Protection Hazardous Materials.
Safety in Agriculture Created by Educational Technology Network
Fire Extinguisher Training Presented by:. The Fire Triangle The Fire Triangle is a simple model used to understand the ingredients necessary for most.
Presentation transcript:

Fire Extinguishers Rating

Unlike some products, extinguishers have to be installed in public premises, and a standard form of assessment is required to determine how many extinguishers and what type are needed to protect a given risk. There are two main rating systems: CEN (European System) U.L. (American System)

CEN European System Class A Fire Extinguishers Crib of wooden sticks. All cribs are 0.56 meters high and 0.5 meters wide, but the length varies for specific ratings. For example the length is 0.3 m for 3A & 5.5 m for 55 A. A tray containing Heptanes is placed under the crib to light the fire.(The test fires are located indoors.) After 2 minutes the try is removed, Fire allowed to burn for 6 minutes. For the test to be successful it is essential that all flames should be extinguished and there should be no recurrence of flaming during the three minutes following the complete discharge of the extinguisher. 2 tests out of 3 succeeded – Ext. passed the test

Class A Fire Tests

Class A test fire – Side view showing 13A fire

Class A Test Fire

Length of Wooden Curbs RateLength of Wooden Curbs 3A0.3 meter 5A0.5 meter 8A0.8 meter 13A1.3 meter 21A2.1 meter 27A2.7 meter 34A3.4 meter 43A4.3 meter 55A5.5 meter

Class B – Flammable Liquids Tests are conducted in a range of welded sheet circular cylindrical trays. Each tray in the series is designated by a number representing the amount of fuel required in liters as in the table. The fuel is Heptanes. The fire is allowed for 1 minute pre-burn. The wind speed should not be greater than 3m/sec. And ambient temp. between 0 – 30 degree C. 2 tests out of 3 – Ext. succeeded.

Class B Tests

RatingVolume of Fuel in Liter 8B 13B 8 liters 13 liters 21B 34B 21 liters 34 Liters 55B 70B 55 liters 70 Liters 89B 113B 89 liters 113 Liters 144B 183B 233B 144 liters 183Liters 233 Liters

U.L. Rating System Class A Fire Test Wood – Crib Fire Test: Tests up to 10A in draft free room. For rating class exceeding 10A the test may be conducted outdoors. A test fire shall be considered to be extinguished – no self resignation. 2 tests out of 3 – ext. succeeded.

Class A Fire Test

Dimension of Wooden Curbs Rate# of Sticks Dimension In millimeter # of Layer s # of Sticks in each layer 1A5045X45X A9845X45X A15345X45X A20945X45X A15045X65X

Class B Fire Test Flammable liquid fire tests are to be conducted in a large volume draft-free room for a rating 20B. For more than 20B rating is conducted outdoor. Tests to be conducted in square shape trays.

Class B Fire Test

RatingVolume of Fuel 1B12 LITER 10B120 LITER 20B250 LITER 30B350 LITER 40B475 LITER 60B720 LITER 80B950 LITER

Outdoor Tests 120-B375 gallons 160-B500 gallons 240-B750 gallons 320-B1000 gallons 480-B1500 gallons 640-B2000 gallons

Selection and Distribution of Fire Extinguishers

C A B C D Ordinary Combustibles Combustible Metals Flammable Liquids Electrical Equipment Identification of Fire Extinguishers

Class A –Triangle containing the letter A –Green Class B –Square containing the letter B –Red

Identification of Fire Extinguishers Class C –Circle containing the letter C –Blue Class D –Five point star containing the letter D –Yellow

Selecting Extinguishers The size and type of portable fire extinguisher is based on the total amount of Class A combustible materials, the total amount of Class B flammables, or, for some occupancies, a combination of both. For many areas, the extinguishing agent also must be compatible with energized electrical equipment.

Classification of Hazards Light (Low) Hazard: Are locations in which the total amount of Class A combustible materials, including furnishings, decorations, and contents, is minor. These occupancies may include buildings or rooms occupied as offices, classrooms, assembly halls. Small amount of Class B flammables used in duplicating machines, art departments, and the like are included.

Ordinary (Moderate) Hazard Are locations in which the total amount of Class A and Class B are present in greater amounts than may be expected in light hazard occupancies. Dining areas, mercantile shops and their allied storage, light manufacturing facilities, auto show rooms, parking garages, and warehouses containing Class I or Class II commodities.

Extra (High) Hazards Are locations in which the total amount of Class A and Class B present in storage, in production, or as finished products is over that expected in ordinary hazard occupancies. Woodworking shops, vehicle repair areas, aircraft and boat servicing facilities, cooking areas, painting, dipping and coating areas, also included is warehousing or in-process storage of commodities other than Class I and II commodities.

Distributing Extinguishers Extinguishers should be placed in locations provide easy access and are readily free from temporary blockage. Near normal paths of travel, near exits and entrances. Mounted on walls, the operating instructions must face outwards, and can be removed easily.

Continue Ext. with gross weight of no more than 40 pounds (18 kgs) should be installed so that the top of the extinguisher is not more than 5 feet above the floor. Ext. more than 40 pounds (except wheeled types) should be installed so that the top of the extinguisher is not more than 3.5 feet from the floor. In no case should the clearance between the bottom of the extinguisher and the floor be less than 4 inches.

Minimum number and rating for Class A fires Light (low) hazard occupancy Ordinary (Mod.) Hazard Extra (High) Hazard Min. Rated Single Ext. 2-A 4-A Maximum floor area per unit of A 3000 sq. ft.1500 sq. ft.1000 sq. ft. Max. floor area for ext sq. ft. Max. travel dist. to Ext 75 ft.

Maximum Area Ext. Can Protect

Distribution of Class A Fire Extinguishers جدول رقم ( 1 ) دليل توزيع أجهزة الإطفاء للنوع A Max. Area to be Protected Per Ext. sq. ft.Max. Travel Distance Class A Rating Extra Hazard Ord. Hazard Light Hazard قدم1A قدم2 A قدم3 A قدم4 A قدم6 A قدم10 A قدم20 A قدم30 A قدم40 A

Maximum Area Ext. Can Protect

Example

Area = 450X150 = Ft² From the table: / = 6 fire ext. 6 x 4A light hazard 6 x 10A ordinary hazard 6 x 20A extra hazard The travel distance rule (75ft) has been violated.

Example

Area Ft² / 6000 = 12 fire extinguishers 12 x 2A light hazard 12 x 4A ordinary hazard 12 x 6A extra hazard In this case both distribution and travel distance rules are fulfilled.

Example

CEN System

Application of the Rated Extinguisher To determine the number of extinguishers required multiply the floor area of a building in square meters by a factor of The resulting number is the Class A cover requirement and should be divided by achieved Class A fire extinguishing rating of the extinguisher

Example A room has an area of 1000 square meters, so 1000 x = 65 If you assume that 9 litre water extinguishers with a fire rating of 13A will be used. By dividing 65 by 13 you will get the number of extinguishers required. 65/13 = 5 ext.

Distribution of Class B Fire Extinguishers - أقصى مسافة بين موقع الخطر وموقع الجهاز الحد الأدنى لمعدل أداء الجهازنوع المخاطر 30 قدم 50 قدم 5 B 10 B مخاطر خفيفة 30 قدم 50 قدم 10 B 20 B مخاطر عادية 30 قدم 50 قدم 40B 80B مخاطر جسيمة

CEN System

Application of the Rated Ext. The type of risk should be determined and the following rules should be followed: 1.Each room or enclosure should be considered separately. 2.Risks more than 20 m apart should be considered separately. 3.Where containers are stacked less than 2 m apart they should be considered undivided group. 4.A divided group comprises 2 or more containers more than 2 m but less than 20 m apart.

1.For single open topped containers see table 1, serial 1, the rating must be reached by each extinguisher provided. 2.For undivided groups see table 1, serial 2 3.For divided groups see table 1, serial 3 4.Spillage, see table 1, serial 4

Example 1 Take a single dip-tank with an area of 2 square meters. The recommended rating of extinguisher is given by: Column2: 50x2.0 = 100 i.e. 113B (foam only) Column3: 80x2.0 = 160 i.e. 183 (any other type) The minimum aggregate rating is recommended as: Column4: 150 x 2.0 = 300B (The minimum aggregate rating of 300B is not met by a single ext., therefore: 300 / 183 = 2 183B

Example 2 Take a bund measuring 2.47 square meters (1.3 x 1.9 m). What is the minimum rating extinguisher recommended?

Distribution for CLASS C Installed where there is live electrical equipment. Carbon Dioxide, Dry Chemical, and Halons Power has cut off the fire becomes Class A or Class B.

Distribution for Class D The amount of agent needed normally is figured according to the surface area of the metal plus the shape and form of the metal which can contribute to the severity of the fire. Travel distance 75 ft.

Classification and Ratings DescriptionRating 2.5 gallon water2A 20 lb Carbon Dioxide10B:C 5 lb dry chemical (ammonium ph.)2A:10B:C 10 lb dry chemical (Sod. Bicarb.)60B:C 10 lb dry chemical (pot. Bicarb.)80B:C 125 lb dry chemical (amm. Phosph)40A:240B:C 33 gal. AFFF20A:160B 5 LB HALON B:C 9 LB HALON 12111A:10B:C 1.5 LB HALON 1211/13011B:C