R&D on CsI(Tl) + APD Optimisation of the energy resolution M. Gascón I.Durán.

Slides:



Advertisements
Similar presentations
1 Proton detection with the R3B calorimeter, two layer solution IEM-CSIC sept report MINISTERIO DE EDUCACIÓN Y CIENCIA CONSEJO SUPERIOR DE INVESTIGACIONES.
Advertisements

Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
Introduction This project used cosmic rays to test a prototype Minimum Bias Trigger Scintillator (MBTS) that will be used in the ATLAS experiment at CERN.
Proposal for a barrel prototype H. Álvarez-Pol, J. Benlliure, E. Casarejos, D. Cortina, I. Durán, M. Gascón Status of the USC 15 th October 2007.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan 1.Introduction 2.Recent.
The Detection of Radioisotopes Using a Thin Scintillating Fiber in a Spiral Adam Jernigan and Eric Blue Advisor: Dr. Thomas Dooling The University of North.
*Shuji Maeo 1,2, Takayuki Yanagida 1, Yuui Yokota 1 and Akira Yoshikawa 1,3 1 Division of Physical Process Design, Institute of Multidisciplinary Research.
Tests of scintillators CsI, CsI(Na), BGO, NaI(Tl) CsI(Tl)
ipno.in2p3.fr Milano - October 2006IPNO-RDD-Jean Peyré1 Measurements of CsI(Tl) Crystals with PMT and APD Jean Peyré Milano - Oct 2006.
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
New Readout Methods for LAr detectors P. Otyugova ETH Zurich, Telichenphysik CHIPP Workshop on Neutrino physics.
Crystals !? R3B/EXL meeting Milan Oct-06. Crystal growing factories Quality and price on 20(23)*20(23)*110 mm 3 detector light output uniformity* price.
Proposal for a barrel prototype H. Álvarez-Pol, J. Benlliure, E. Casarejos, D. Cortina, I. Durán, M. Gascón Status of the USC 27 th September
GEANT4 simulations for the Lund R 3 B prototype Douglas Di Julio Lund University, Lund, Sweden.
Nustar/crystal simulations B. Genolini Crystal: CsI(Tl) (Saint Gobain), wrapped with reflector (VM2000, Tyveck?) Geometry:
Crystals and related topics J. Gerl, GSI NUSTAR Calorimeter Working Group Meeting June 17, 2005 Valencia.
Especially concerning optimization of identification power, energy resolution, efficiency, optimal readout device for the barrel part of CALIFA, a calorimeter.
Status of the Calorimeter Working group activities GSI, 16 th October 2007.
R 3 B Gamma Calorimeter H. Alvarez Pol – R 3 B Gamma Calorimeter NUSTAR Calorimeter WG – Valencia 17/06/05 H. Alvarez Pol, D. Cortina, I. Durán GENP –
ipno.in2p3.fr Orsay - October 2007IPNO-RDD-Jean Peyré1 Test Protocole for Crystals with Gamma Sources Jean Peyré Oct 2007.
ipno.in2p3.fr Lund - June 2007IPNO-RDD-Jean Peyré1 Measurements of some Crystals with PMT R&D on Calorimeters Jean Peyré Lund - June 2007.
Ideas on VFEE I. Durán Universidad de Santiago de Compostela NUSTAR Calorimeter WG Valencia, June 2005.
H. Alvarez Pol - NUSTAR Calorimeter WG R3B/EXL Collaboration Meeting - Santiago Sept Geometrical design, simulation progress and first detector.
Photon detection Visible or near-visible wavelengths
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
PPARC forum on developments in scintillator technology R M Brown - RAL 1 Scintillating Crystals for Particle Physics Outline  Performance considerations.
The HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  The crystal modules  The frame and transporter  Temperature stability.
EXL/crystal simulations B. Genolini Simulation of NUSTAR crystals with Litrani Presentation of Litrani: simulation of.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
R 3 B Gamma Calorimeter Agenda. ● Introduction ● Short presentation on the first ● Task definition for R&D period ( )
DSSD – Si, 300 mkm, 1.85 mm pitch, 59.5x59.5 mm**2. CsI(Tl)/PD, 20x20(front)23x23(back)x100mm**3. Produced by St.Gobain, Khar’kov and China Companies PD.
Calorimetry: a new design 2004/Sep/15 K. Kawagoe / Kobe-U.
Evaluation of Silicon Photomultiplier Arrays for the GlueX Barrel Calorimeter Carl Zorn Radiation Detector & Medical Imaging Group Jefferson Laboratory,
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics.
Light Output Uniformity of Long CsI(Tl) crystals - the “bottle-neck” for gamma and proton spectroscopy Light Output Uniformity for CsI(Tl) as supplied.
The CMS Electromagnetic Calorimeter Roger Rusack The University of Minnesota On behalf of the CMS ECAL collaboration.
T. Sugitate / Hiroshima / PHX031 / Nov.01 The Photon Spectrometer for RHIC and beyond PbWO 4 Crystal Density 8.29 g/cm 3 Radiation length 0.89 cm Moliere.
Simulation of the energy response of  rays in CsI crystal arrays Thomas ZERGUERRAS EXL-R3B Collaboration Meeting, Orsay (France), 02/02/ /03/2006.
Lead Fluoride Calorimeter for Deeply Virtual Compton Scattering in Hall A Alexandre Camsonne Hall A Jefferson Laboratory October 31 st 2008.
Gain stability and the LYSO beam radiation monitor measurements
Activities on double beta decay search experiments in Korea 1.Yangyang Underground laboratory 2.Double beta decay search with HPGe & CsI(Tl) 3.Metal Loaded.
Photon Detector with PbWO 4 Crystals and APD Readout APS “April” Meeting in Denver, CO on May 4, 2004 presented by Kenta Shigaki (Hiroshima University,
APD. photosensors: L arge A rea A valanche P hoto D iodes (LAAPD) in collaboration with Hamamatsu Photonics CMS 5x5mm 2 10x10mm 2 new excellent performance.
Scintillators suitable for PET applications must be characterized by a high efficiency for gamma-ray detection, determined by a high density and atomic.
Concept of NA62 IRC based on PWO scintillation crystals A.Fedorov, M. Korjik, A. Lobko Institute for Nuclear Problems, Minsk, Belarus A. Kourilin JINR,
APS, 44th Annual Meeting of the Division of Plasma Physics November 11-15, 2002; Orlando, Florida Hard X-ray Diagnostics in the HSX A. E. Abdou, A. F.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Development of UV-sensitive MPPC for upgrade of liquid xenon detector in MEG experiment Daisuke Kaneko, on behalf of the MEG Collaboration µ γ Liquid xenon.
CMS ELECTROMAGNETIC CALORIMETER Jean-Pierre Ernenwein OVERVIEW 6th international conference on advanced technology and particle physics Villa Olmo, Como,
CALIFA - USC R&D activities: Designing and prototyping CALIFA a next generation calorimeter for R3B/FAIR Huelva July 07.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
3/06/06 CALOR 06Alexandre Zabi - Imperial College1 CMS ECAL Performance: Test Beam Results Alexandre Zabi on behalf of the CMS ECAL Group CMS ECAL.
Hybrid Detector(s) for Complete Gamma Ray Spectroscopy S. S. Bhattacharjee, R Raut, S S Ghugre, A K Sinha UGC-DAE Consortium For Scientific Research, Kolkata.
26th September 2014 Guillermo Ribeiro 1 G. Ribeiro, E. Nácher, A. Perea, J. Sánchez del Río, O. Tengblad Instituto de Estructura de la Materia – CSIC,
Gamma Spectrometry beyond Chateau Crystal J. Gerl, GSI SPIRAL 2 workshop October 5, 2005 Ideas and suggestions for a calorimeter with spectroscopy capability.
Energy and time resolution for a LYSO matrix
IFR Detector R&D status
IFR Detector R&D status
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
Frontier Detectors for Frontier Physics
The Lund R3B prototype: In-beam proton tests and simulations
Upgrade of LXe gamma-ray detector in MEG experiment
LSO/LYSO Crystals for Future High Energy Physics Experiments
BESIII EMC electronics
Gain measurements of Chromium GEM foils
Presentation transcript:

R&D on CsI(Tl) + APD Optimisation of the energy resolution M. Gascón I.Durán

R3B calorimeter Total absorption efficiency 80 % (E  =15 MeV lab) Very large crystals E  sum  (E sum )/ <10%(same as  E/E)  Multiplicity  (N  )/ < 10% Moliere Radius  E/E for  2-3 %Scintillation properties Detector granularity  E/E for p (up to 300 MeV) Calorimeter for p 3 %Large crystals Dynamic range Large dynamic range for detecting p,  Inner radius 35 cm ( house Si trackers) Main characteristics (from R3B Tech Proposal) : R&D on crystals + readout systems Design based on CAD + GEANT4 full simulations see -> calorimeter -> reports and talks

Calorimeter sectors Demonstrator meeting, Madrid May-09 Due to the Lorentz boost we identify three sectors: E CM = 10 MeV β =

Crystals !? R3B/EXL meeting Milan Oct-06

Crystals M. Mozynski et al., NIM A 485(2002)504 (API LAAPD)

CsI (Tl) 10x10x10, 10x10x50,10x10x100, 10x20x170 mm CsI (pure) 10x10x10, 10x10x50,10x10x100 mm LaCl3(Ce) 10x10x10, 10x10x50,10x10x100, 10x20x170 mm Standard 10-stage, 19 mm tube, lima glass, Green bi-alkaliXP1901 Standard 10-stage, 19 mm tube, fused silica, UV bi-alkaliXP1918 Standard 10-stage, 25 mm tube, borosilicate glass, bi-alkaliXP mm 2 UV extended ( nm)S5345+ API 10x10 mmS (PANDA) 5x5 mmS (CMS) St Gobain Photonis Hamamatsu R3B/EXL meeting Milan Oct-06 Material we used for test

R&d on crystals and APDs Crystals from StGobain (France) tested coupled to LAAPD from Hamamatsu (Japan) and API (USA)

R3B/EXL meeting Milan Oct-06 Data-taking setups Standard pulse-height analysis : - preamplifiers: Canberra 2001A, Ortec R142 - Shapping amplifier: Canberra Multichannel analyzer: Ortec Maestro or Amptek MCA-8000 Pulse-shape analysis : - Oscilloscope Tektronix TDS3054B - Off-line Digital filtering: Trapezoidal finite-impulse algorithm Not used for APDs but providing the best results for PMT!

Experimental setup

Test at Genp-Lab (USC)

APD gain vs. Bias Voltage 5 cm length The energy resoltution depends on the APD gain and the Bias Voltage ~380V Dgain/DV= 2.84 % The energy resoltution shows a minimum when The APD Bias Voltage=380

Dependence on shapping time For small crystals 4ms is a good compromise between energy-resolution and pile-up

Dependence on the acquisition time Best results achieved for acquisition times between s These curves conatin two effects: statistics and bias voltage drift. Could be solved by controling Temperature and Bias Voltage

Dependence on Amplifier Gain Energy resolution improves by increasing the amplifier gain

Best results

Study of the non-uniformity Energy resolution dependence on the first interaction point Non-uniformity ~ 8.4 %, to compare with < 3% measured by St. Gobain Light collection uniformity CMS CAL P. Sempere PhD Thesis

CsI(Tl) Resolution R3B/EXL meeting Milan Oct-06 Energy resolution improves for increasing energy CsI(Tl) with a 60 Co source (1171 keV) and (1332 keV)

Some conclusions Several test (wrapping, optical coupling,amplifier gain, shapping time) have been performed to optimise the energy resolution of CsI(Tl) APDs from API showed the best energy resolution for CsI(Tl) crystals APDs S from Hamamatsu showed a very good energy resolution almost independent on the crysal size The main drawback of APDs vs PMT is the strong dependence of the gain with Temperature and Bias Voltage How to improve the resolution: -Better stabilisation of both temperature and bias-voltage. - Better optical coupling --> Scionix - Surface coating --> Ukranian Institute for Crystals - New generation of scintillating crystals

T and V dependence Both Crystals and APDs response depends on Tº  T must be kept very stable ! ~0.1 o otherwise, T should be accurately measured in order to keep gain constant by controlling the bias voltage

Characterization of S APD T. Ikagawa et al., NIM A 538(2995) 640 T stabilisation ~0.1ºC keep the gain variarion ~ 0.3%

Temperature stabilisation Refrigerator 4-5 º C Humidity control box < 30% (1%) radiator Resistor warm focus T probe T stable within 0.1ºC Ceramics Cold focus ~ 10ºC T controller 22ºC Allow pulse shape analysis with Tektronix TDS3054B

Crystal type-2 Bi-frustrum shaped Waiting for an agreement with StGobain and IMP- Lanzhou(China) --> Price drop! Exit face fits to LAAPD S under negotiation First prototypes done at Lanzhou (China Further tests through prototype Good results are only achieved when there is a perfect matching between the crystal exit surface and the APD entrance area Type 2 View of the Barrel average dimensions 3x1x13 cm

Study of St. Gobain vs IMP Lanzhou crystals Tests performed with API APD Crystal dimensions 1x1x1 cm Very similar behaviour

Resolution achieved IMP Lanzhou St. Gobain

R3B Type Crystal

Uniformity of the crystal Wrapped with ESR (from 3M), tested with 60Co