Design with Root Locus Lecture 9.
Advertisements

Chapter 4: Basic Properties of Feedback
Automated Control Systems, 8/E by Benjamin C. Kuo and Farid Golnaraghi Copyright © 2003 John Wiley & Sons. Inc. All rights reserved. Figure 10-1 (p. 433)
Nyquist Stability Criterion
Modern Control Theory Lecture 5 By Kirsten Mølgaard Nielsen
Nise/Control Systems Engineering, 3/e
Control Systems Engineering, Fourth Edition by Norman S. Nise Copyright © 2004 by John Wiley & Sons. All rights reserved. Figure 9.1 a. Sample root locus,
Multivariable Control
Chapter 7 System Compensation (Linear Control System Design)
Chapter 8 Root Locus and Magnitude-phase Representation
A Typical Feedback System
Quiz: Find an expression for in terms of the component symbols.
Chapter 5 – The Performance of Feedback Control Systems
PD Controller 1.Find the steady-state output due to unit-step r d. 2.Find the steady-state output due to unit-step input (with r d =0)
Control System Design Based on Frequency Response Analysis
Chapter 10 – The Design of Feedback Control Systems
Controller Tuning: A Motivational Example
Transient and steady state response (cont.)
Process Control Instrumentation II
Lecture 9: Compensator Design in Frequency Domain.
Lect. 5 Lead-Lag Control Basil Hamed
Design of Control Systems Cascade Root Locus Design This is the first lecture devoted to the control system design. In the previous lectures we laid the.
PID Control and Root Locus Method
Proportional/Integral/Derivative Control
Lecture 5: PID Control.
Control System Design Based on Frequency Response Analysis
f(t) m x(t) fd(t) LINEAR CONTROL C (Ns/m) k (N/m)
Chapter 7 Control Systems Design by Root-Locus Method 7.1 Introduction -The primary objective of this chapter is to present procedures for the design and.
Ch. 6 Single Variable Control
Automatic Control System
سیستمهای کنترل خطی پاییز 1389 بسم ا... الرحمن الرحيم دکتر حسين بلندي- دکتر سید مجید اسما عیل زاده.
2-1 (a),(b) (pp.50) Problem: Prove that the systems shown in Fig. (a) and Fig. (b) are similar.(that is, the format of differential equation is similar).
INC341 Design with Root Locus
Automatic Control Systems
Chapter 5 Transient and Steady State Response “I will study and get ready and someday my chance will come” Abraham Lincoln.
INC341 Design Using Graphical Tool (continue)
Signals and Systems Fall 2003 Lecture #20 20 November Feedback Systems 2. Applications of Feedback Systems.
1 Chap 6 The Compensation of the linear control systems P553.
سیستمهای کنترل خطی پاییز 1389 بسم ا... الرحمن الرحيم دکتر حسين بلندي - دکتر سید مجید اسما عیل زاده.
MESB374 System Modeling and Analysis PID Controller Design
Control systems KON-C2004 Mechatronics Basics Tapio Lantela, Nov 5th, 2015.
Chapter 5 Dynamics and Regulation of Low-order Systems
SERVO VALVES.
Lecture 16: Introduction to Control (Part II)
Chapter 4 A First Analysis of Feedback Feedback Control A Feedback Control seeks to bring the measured quantity to its desired value or set-point (also.
MESB374 System Modeling and Analysis Feedback Control Design Process
System Time Response Characteristics
Automated Control Systems, 8/E by Benjamin C. Kuo and Farid Golnaraghi Copyright © 2003 John Wiley & Sons. Inc. All rights reserved. Figure 7-1 (p. 235)
1 Time Response. CHAPTER Poles and Zeros and System Response. Figure 3.1: (a) System showing input and output; (b) Pole-zero plot of the system;
Exercise 1 (Root Locus) Sketch the root locus for the system shown in Figure K 1 (
1 Teaching Innovation - Entrepreneurial - Global The Centre for Technology enabled Teaching & Learning, M G I, India DTEL DTEL (Department for Technology.
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
Modern Control Systems (MCS) Dr. Imtiaz Hussain Assistant Professor URL :
Lecture 10 Feedback Control Systems President UniversityErwin SitompulFCS 10/1 Dr.-Ing. Erwin Sitompul President University
Intelligent Robot Lab Pusan National University Intelligent Robot Lab Chapter 7. Forced Response Errors Pusan National University Intelligent Robot Laboratory.
SKEE 3143 Control Systems Design Chapter 2 – PID Controllers Design
Vision Lab System VISION SYSTEM Chapter 9. Design via Root Locus Youngjoon Han
Lecture 7/8 Analysis in the time domain (II) North China Electric Power University Sun Hairong.
CIS 540 Principles of Embedded Computation Spring Instructor: Rajeev Alur
Exercise 1 Suppose we have a simple mass, spring, and damper problem. Find The modeling equation of this system (F input, x output). The transfer function.
Page : PID Controller Chapter 3 Design of Discrete- Time control systems PID C ontroller.
Lesson 20: Process Characteristics- 2nd Order Lag Process
Control Systems EE 4314 Lecture 12 March 17, 2015
Design via Root Locus (Textbook Ch.9).
A First Analysis of Feedback
Chapter 9 Design via Root Locus <<<4.1>>>
Chapter 9 Design via Root Locus <<<4.1>>>
Compensators.
Synthesis of SISO Controllers
ECE 576 POWER SYSTEM DYNAMICS AND STABILITY
Presentation transcript:

9-7 Design with Lead-Lag Controller Section 9- 7, p. 574 9-7 Design with Lead-Lag Controller Transfer function of a simple lead-lag (or lag-lead) controller: The phase-lead portion is used mainly to achieve a shorter rise time and higher bandwidth, and the phase-lag portion is brought in to provide major damping of the system. Either phase-lead or phase-lag control can be designed first. lead lag

Example 9-7-1: Sun-Seeker System Section 9- 7, p. 575 Example 9-7-1: Sun-Seeker System Example 9-5-3: two-stage phase-lead controller design Example 9-6-1: two-stage phase-lag controller design Phase-lead control: From Example 9-5-3  a1 = 70 and T1 = 0.00004 Phase-lag control:

Section 9- 7, p. 575 Example 9-7-1 (cont.)

9-8 Pole-Zero-Cancellation Design: Notch Filter Section 9- 8, p. 576 9-8 Pole-Zero-Cancellation Design: Notch Filter The complex-conjugate poles, that are very close to the imaginary axis of the s-plane, usually cause the closed-loop system to be slightly damped or unstable.  Use a controller to cancel the undesired poles Inexact cancellation:

Inexact Pole-Zero Cancellation Section 9- 8, p. 577 Inexact Pole-Zero Cancellation K1 is proportional to 11, which is a very smaller number. Similarly, K2 is also very small. Although the poles cannot be canceled precisely, the resulting transient-response terms will have insignificant amplitude, so unless the controller earmarked for cancellation are too far off target, the effect can be neglected for all practical purpose.

Section 9- 8, p. 577

Section 9- 8, p. 578

Second-Order Active Filter Section 9- 8, p. 579 Second-Order Active Filter

Frequency-Domain Interpretation Section 9- 8, p. 580 Frequency-Domain Interpretation “notch” at the resonant frequency n. Notch controller do not affect the high- and low-frequency properties of the system

Section 9- 8, p. 581 Example 9-8-1

Example 9-8-1 (cont.) Loop transfer function: Section 9- 8, p. 582 Example 9-8-1 (cont.) Loop transfer function: Resonant frequency  1095 rad/sec The closed-loop system is unstable.

Example 9-8-1: Pole-Zero Cancellation Section 9- 8, p. 582 Example 9-8-1: Pole-Zero Cancellation Pole-Zero-Cancellation Design with Notch Controller Performance specifications: The steady-state speed of the load due to a unit-step input should have an error of not more than 1% Maximum overshoot of output speed  5% Rise time  0.5 sec Settling time  0.5 sec Notch controller:  to cancel the undesired poles 47.66  j1094 The compensated system:

Example 9-8-1 (cont.) G(s): type-0 system: Step-error constant: Section 9- 8, p. 583 Example 9-8-1 (cont.) G(s): type-0 system: Step-error constant: Steady-state error: ess  1%  KP  99 Let n = 1200 rad/sec and p = 15,000 Maximum overshoot = 3.7% Rise time tr = 0.1879 sec Settling time ts = 0.256 sec

Example 9-8-1: Two Stage Design Section 9- 8, p. 583 Example 9-8-1: Two Stage Design Choose n = 1000 rad/sec and p = 10 the forward-path transfer function of the system with the notch controller:  maximum overshoot = 71.6% Introduce a phase-lag controller or a PI controller to Eq. (9-167) to meet the design specification given.

Example 9-8-1: Phase-Lag Controller Section 9- 8, p. 584 Example 9-8-1: Phase-Lag Controller Second-Stage Phase-Lag Controller Design Phase-lag controller:

Example 9-8-1: PI Controller Section 9- 8, p. 584 Example 9-8-1: PI Controller Second-Stage PI Controller Design PI controller: Phase-lag controller (9-169)  KP = 0.005 and KI/KP = 20  KI = 0.1 maximum overshoot = 1% rise time tr = 0.1380 sec settling time ts = 0.1818 sec

Example 9-8-1: Pole-Zero Cancellation Section 9- 8, p. 585 Example 9-8-1: Pole-Zero Cancellation Sensitivity due to Imperfect Pole-Zero Cancellation Transfer function: maximum overshoot = 0.4% rise time tr = 0.17 sec settling time ts = 0.2323 sec Notch Controller

Example 9-8-1: Unit-Step Responses Section 9- 8, p. 585 Example 9-8-1: Unit-Step Responses

Example 9-8-1: Freq.-Domain Design Section 9- 8, p. 586 Example 9-8-1: Freq.-Domain Design attenuation =  44.86 dB

Example 9-8-1: Notch Controller Section 9- 8, p. 586 Example 9-8-1: Notch Controller PM = 13.7° Mr = 3.92

Section 9- 8, p. 587 Example 9-8-1 (cont.)

Example 9-8-1: Notch-PI Controller Section 9- 8, p. 586 Example 9-8-1: Notch-PI Controller Desired PM = 80° New gain-crossover frequency: (9.32)  (9.25) 

Section 9- 8, p. 588 Example 9-8-1 (cont.)

9-9 Forward and Feedforward Controllers Section 9- 9, p. 588 9-9 Forward and Feedforward Controllers Forward compensation:

Section 9- 9, p. 589 Example 9-9-1 Second-order sun-seeker with phase-lag control (Ex. 9-6-1): Time-response attributes: maximum overshoot = 2.5%, tr = 0.1637 sec, ts = 0.2020 sec Improve the rise time and the settling time while not appreciably increasing the overshoot  add a PD controller Gcf(s) to the system (forward) add a zero to the closed-loop transfer function while not affecting the characteristic equation  maximum overshoot = 4.3%, tr = 0.1069, ts = 0.1313

Feedforward controller Section 9- 9, p. 590 Example 9-9-1 (cont.) Forward controller Feedforward controller

9-10 Design of Robust Control Systems Section 9- 10, p. 590 9-10 Design of Robust Control Systems Control-system application: 1. the system must satisfy the damping and accuracy specifications. 2. the control must yield performance that is robust (insensitive) to external disturbance and parameter variations d(t) = 0  r(t) = 0 

Section 9- 10, p. 591 Sensitivity Disturbance suppression and robustness with respect to variations of K can be designed with the same control scheme.

Section 9- 10, p. 591 Example 9-10-1 Second-order sun-seeker with phase-lag control (Ex. 9-6-1) Phase-lag controller  low-pass filter the sensitivity of the closed-loop transfer function M(s) with respect to K is poor a = 0.1 T = 100

Section 9- 10, p. 592

Section 9- 10, p. 593

Section 9- 10, p. 594 Example 9-10-1 (cont.) Design strategy: place two zeros of the robust controller near the desired close-loop poles According to the phase-lag-compensated system, s = 12.455  j9.624 Transfer function of the controller: Transfer function of the system with the robust controller:

Section 9- 10, p. 595

Section 9- 10, p. 596 Example 9-10-1 (cont.)

Section 9- 10, p. 596

Section 9- 10, p. 597 Example 9-10-1 (cont.)

Section 9- 10, p. 597

Section 9- 10, p. 597 Example 9-10-2 Third-order sun-seeker with phase-lag control (Ex. 9-6-2) Phase-lag controller: a = 0.1 and T = 20 (Table 9-19)  roots of characteristic equation: s = 187.73  j164.93 Place the two zeros of the robust controller at 180  j166.13  Forward controller:

Section 9- 10, p. 598 Example 9-10-2 (cont.)

Section 9- 10, p. 599 Example 9-10-2 (cont.)

Section 9- 10, p. 599 Example 9-10-3 Design a robust system that is insensitive to the variation of the load inertia. Performance specifications: 0.01  J  0.02 Ramp error constant Kv  200 Maximum overshoot  5% Rise time tr  0.05 sec Settling time ts  0.05 sec s = 50  j86.6 s = 50  j50

Section 9- 10, p. 600 Example 9-10-3 (cont.) Place the two zeros of the robust controller at 55  j45  K = 1000 and J = 0.01: K = 1000 and J = 0.02: Forward controller:

Section 9- 10, p. 600 Example 9-10-3 (cont.)

9-11 Minor-Loop Feedback Control Section 9- 11, p. 601 9-11 Minor-Loop Feedback Control Rate-Feedback or Tachometer-Feedback Control Transfer function: Characteristic equation: The effect of the tachometer feedback is the increasing of the damping of the system.

Steady-State Analysis Section 9- 11, p. 602 Steady-State Analysis Forward-path transfer function:  type 1 system For a unit-ramp function input: tachometer feedback  ess = (2+Ktn)/n PD control  ess = 2/n For a type 1 system, tachometer feedback decrease the ramp-error constant Kv but does not affect the step-error constant KP.

Section 9- 11, p. 603 Example 9-11-1 Second-order sun-seeker system:

Example 9-11-1 Characteristic equation: Section 9- 11, p. 604 Example 9-11-1 Characteristic equation: Kt = 0.02: maximum overshoot = 0 tr = 0.04485 sec ts = 0.06061 sec tmax = 0.4 sec

9-12 A Hydraulic Control System Section 9- 12, p. 605 9-12 A Hydraulic Control System double-acting single rod linear actuator two-stage electro-hydraulic valve

Modeling Linear Actuator Section 9- 12, p. 606 Modeling Linear Actuator The applied force: f: the force efficiency of the actuator Volumetric efficiency: for an ideal case 

Four-Way Electro-Hydraulic Valve Section 9- 12, p. 606 Four-Way Electro-Hydraulic Valve Two-stage control valve: The first stage is an electrically actuated hydraulic valve, which controls the displacement of the spool of the second stage of the valve. The second stage is a four-way spool valve, which controls the fluid flow and pressure into and out of ports A and B of the actuators. At the nominal operating conditions:

Orifice Equation The classic orifice equation for the fluid flow: Section 9- 12, p. 607 Orifice Equation The classic orifice equation for the fluid flow: The discharge coefficient:

Liberalized Flow Equations for Four-Way Valve Section 9- 12, p. 608 Liberalized Flow Equations for Four-Way Valve Orifice equation: Taylor series: Take x0 = 0 and  Kq: flow gain Kc: pressure-flow coefficient

Rectangular valve-port geometry Section 9- 12, p. 609 Rectangular valve-port geometry For the rectangular geometry: For the open-center valve:

Equations for Four-Way Valve Section 9- 12, p. 610 Equations for Four-Way Valve Volumetric flow rates into and out of the actuator: for critical centered valves 

Input Voltage & Main Spool Displacement Section 9- 12, p. 611 Input Voltage & Main Spool Displacement Flow equation of pilot spool: (the control valve is critically centered) Assuming an incompressible fluid: Displacement of pilot spool:

Transfer Function of Two-Stage Valve Section 9- 12, p. 611 Transfer Function of Two-Stage Valve

Modeling the Hydraulic System Section 9- 12, p. 612 Modeling the Hydraulic System

Mathematical Equations Section 9- 12, p. 612 Mathematical Equations Force balance equation for an ideal linear actuator: Expressing pressure level PA and pressure level PB: Expressing the pressure difference two sides of linear actuator: General equation:

Applications: Translational Motion Section 9- 12, p. 614 Applications: Translational Motion The voltage fed back from the actuator displacement z: The input voltage to the two-stage valve Verror: Desired input zdesired and desired voltage Vdesired: General equation: Transfer function of two-stage valve:

Transfer Func. of Translational System Section 9- 12, p. 615 Transfer Func. of Translational System

Applications: Rotational System Section 9- 12, p. 616 Applications: Rotational System

Transfer Function of Rotational System Section 9- 12, p. 615 Transfer Function of Rotational System The translational displacement of the rod in terms of the angular displacement: Main valve displacement: System transfer function:

Applications: Variable Load Section 9- 12, p. 617 Applications: Variable Load

Section 9- 13, p. 617 9-13 Control Design P Control:

P Control: transfer function Section 9- 13, p. 618 P Control: transfer function Simplified hydraulic system transfer function: (neglecting the pole at 142350) Apply a P controller: closed-loop transfer function:

P Control: root loci & responses Section 9- 13, p. 619 P Control: root loci & responses

Section 9- 13, p. 621 PD Control PD control Closed transfer function:

PD Control: design Steady-state error for a unit-ramp input: Section 9- 13, p. 622 PD Control: design Steady-state error for a unit-ramp input: ess  0.00061  KP  5 Damping ratio for KP = 5:  = 1  KD = 0.0066 Setting time: ts  0.005  KD  0.0044 Stability requirement: KP  0 and KD  0.00307

PD Control: root loci & root contour Section 9- 13, p. 622 PD Control: root loci & root contour Characteristic equation (KD = 0):

Section 9- 13, p. 623 PD Control: responses

Section 9- 13, p. 626 PI Control PI control

Section 9- 13, p. 626 PI Control: design Steady-state error for a ramp input: ess  0.2  KI  0.015 Characteristic equation: stable  KI/KP = 5 

PI Control: root loci & responses Section 9- 13, p. 627 PI Control: root loci & responses

PI Control: attributes Section 9- 13, p. 627 PI Control: attributes PI

Section 9- 13, p. 628 PID Control Transfer function:

PID Control: design PD controller: Table 9-28  KD1 = 0.0066, KP1 = 5 Section 9- 13, p. 629 PID Control: design PD controller: Table 9-28  KD1 = 0.0066, KP1 = 5 PI controller: KI2/KP2 = 5 

PID Control: attributes Section 9- 13, p. 629 PID Control: attributes

PID Control: responses Section 9- 13, p. 630 PID Control: responses