111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing.

Slides:



Advertisements
Similar presentations
Cabling system components
Advertisements

Cabling UTP AND FIBER CABLING. Structured Cabling Infrastructure Mounted and permanent Allows patching Comfort that infrastructure is OK Components: Information.
N ETWORKING MEDIA. COMMON NETWORK CABLES The connection between the source and destination may either be direct or indirect, and may span multiple media.
Fiber Optic Construction & Termination Jeff Hite University of Oregon/NSRC This document is a result of work by the Network Startup Resource.
Cabling Structured Cabling Standards
Physical Transmission Media 8 5/9/ Modified by: Brierley.
1 Telecom Cabling Documentation and labeling. 2 Telecom Cabling Documentation remains a major stumbling block for most networks. Many end-users inherit.
Page 1 - © Richard L. Goldman Networking Topology ©Richard L. Goldman January 8, 2002.
Hands On: Cutting and Connectorizing UTP Chapter 3a Panko’s Business Data Networks and Telecommunications, 6 th edition Copyright 2007 Prentice-Hall May.
Infrastructure and components. Cable The cable and components used in structured cabling systems is defined in the standards –EIA/TIA 568 x There are.
Telecommunications cable types
CS335 Networking & Network Administration Thursday April 1.
Classes of transmission media
Institute of Technology Sligo - Dept of Computing Many Roads To Home Paul Flynn.
NETWORK DESIGN Customer requirements Network topologies Cable choice Hardware TSB 75 TSB72.
Designing and Implementing Cabling Infrastructure Dr. Saif al Zahir King Fahd University of Petroleum & Minerals Computer Engineering Department Dr. Saif.
Fiber Optic Cable Installation Indoors Last Update Copyright Kenneth M. Chipps Ph.D. 1.
BASIC TELECOMMUNICATIONS
Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:
1 The pulse rate in the U.S. is 10 PPS. The break/make ratio is 60/40 DTMF = Dual Tone Multi Frequency Pulse refers to rotary phones Each digit on a telephone.
1 Fiber Optics FIBER OPTIC PATCH PANELS. 2 Fiber Optics Just like our copper cable plant the fiber cable plant incorporates many of the same hardware.
Many Roads To Home. LAN Roads UTP STP Coaxial Fiber Optics.
Guide to Network Cabling Fundamentals
Cisco – Semester 1 – Chapter 9 Preview Review. Behavioral Objectives Document all work –Do it as work proceeds –Same as chapter 8 guidelines –Don’t forget.
1 Connecting to the Internet Through an ISP Networking for Home and Small Businesses – Chapter 4.
The Saigon CTT Semester 1 CHAPTER 9 Le Chi Trung.
NETWORK CABLING Chapter 2
© 2007 Cisco Systems, Inc. All rights reserved.Cisco Public ITE PC v4.0 Chapter 1 1 Connecting to the Internet Through an ISP Networking for Home and Small.
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
Lesson 4 – Network Connectors and Wiring Standards Coaxial Cable Twisted Pair Cable Fiber Optic Cable Practical Video: Twisted Pair – UTP – CAT 6 cable.
1 CCTV SYSTEMS CCTV cables. 2 CCTV SYSTEMS Cable selection is a very important consideration in the performance of a CCTV system, especially where long.
Component 9 – Networking and Health Information Exchange Unit 2-2 Network Media and Hardware Communication Devices This material was developed by Duke.
The Saigon CTT Semester 1 CHAPTER 5 Le Chi Trung.
HORIZONTAL SUBSYSTEM. CABLING SYSTEM Horizontal Subsystem The Horizontal cabling subsystem is the part of the Signamax Cabling System that extends from.
1 Guide to Network Cabling Fundamentals Chapter 5.
SYSTEM ADMINISTRATION Chapter 4 Network Media, Connectors, and Their Characteristics.
Five components of data communication
Chapter 9 Review Structured Cabling Project. Chapter 9 Focus The focus of this chapter is standards for networking media. You read that when RJ-45 jacks.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
Cabling Project. Your first responsibility, as the network designer, will be to have your client specify, in writing, the desired outcome of the project.
Networking and Health Information Exchange Unit 2b Network Media and Hardware Communication Devices Component 9/Unit 2b1 Health IT Workforce Curriculum.
BIX In-Building Cross Connect system BIX Installation Guide ELCM 254 Updated December 2013 gmail.com 1 Most of the images and some text for.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
INTRUSION ALARM TECHNOLOGY
Design and Documentation Chapter 8. Network Design Issues Your first step in the process is to gather information about the organization. This information.
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
Cabling Systems NEWLINK ARE YOU READY FOR THE TECHNOLOGY RACE ?
Chapter 2.  Upon completion of this chapter, you should be able to:  Select & install cables for connecting to a dial-up network  Select & install.
+ Transmission Media. + Local Area Networks LANs consist of Transmission media and network nodes. Transmission media is a pathway that carries the information.
COPPER AND FIBER REVIEW
TELECOMMUNICATIONS SPACES
Chapter 5a. 5a-2 Single Twisted Pair Jacket Four pairs (each pair is twisted) are enclosed in a jacket. Copyright 2011 Pearson Education, Inc. Publishing.
Telecommunications and Networking
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
Lecture 2 unit 1.
Summit Communications Ltd
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards.
Networking Solutions Chapter 3 – Networking Topologies, Connectors, & Wiring Standards.
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
Network Media and Connections. Twisted Pair (UTP)
Cables and connectors Chapter 2 8 days including test.
Level 2 Diploma Unit 10 Setting up an IT Network
Hands On: Cutting and Connectorizing UTP
Hands On: Cutting and Connectorizing UTP
Computer Systems Department.  Introduction  Course Objectives  Grading Policy  Lab Policy  Structured Cabling.
Hands On: Cutting and Connectorizing UTP
Presentation transcript:

111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing jacks and wall plates

222 © 2002, Cisco Systems, Inc. All rights reserved. Cutting cable When cutting cable, leave excess cable to allow for mistakes or problems when terminating at the patch and termination panels in the telecommunications rooms. At the wall outlet, leave some excess cable that can be coiled in the wall box.

333 © 2002, Cisco Systems, Inc. All rights reserved. Labeling cable Labeling cable is essential to good cable management. It is best to label cable before terminating it. If this was not done, use a tone and probe set to identify the cables. Use an industry accepted labeling scheme such as the one specified in ANSI/TIA/EIA 606.

444 © 2002, Cisco Systems, Inc. All rights reserved. Dressing cables Cable management is important to protect and organize cables. It is never acceptable to place cables over a dropped ceiling or to lay them on ceiling tiles. Similarly, cables should not be exposed around work areas since they can be accidentally stretched, kicked, or even pulled out of the outlet.

555 © 2002, Cisco Systems, Inc. All rights reserved. Types of management equipment Raceways Baskets J-hooks and bridle rings D-rings and mushrooms Ladder systems Cable trays Fasteners Management systems

666 © 2002, Cisco Systems, Inc. All rights reserved. Management equipment

777 © 2002, Cisco Systems, Inc. All rights reserved. Management systems Cables management systems can be open or closed. Open systems are accessible so it is easy to route, test, add, or remove cables. Closed systems provide better protection for the cables from dust, water, rodents, and insects.

888 © 2002, Cisco Systems, Inc. All rights reserved. Management system qualities The system should protect the cable from pinching and maintain the maximum bend radius. The system is scalable so when more cables are needed, it can handle them. The system is flexible so cables can come into it from all directions. The system offers a smooth transition to horizontal pathways so cable is not damaged or exceeds maximum bend radius. The system is durable so that it will last as long as the cables and equipment that is mounted on it.

999 © 2002, Cisco Systems, Inc. All rights reserved. Terminating media When cable is run between a TR and a work area – One end is terminated on a patch panel in the TR – The other end is terminated at the work area outlet.

10 © 2002, Cisco Systems, Inc. All rights reserved. Terminating on patch panels Patch panels are used to interconnect data networking or voice systems to the physical cable network. Patch panels are also used to interconnect backbone cable systems to network distribution cable systems. A uniform wiring plan must be used throughout a patch panel system. All jacks and patch panels should be wired using the same wiring plan.

11 © 2002, Cisco Systems, Inc. All rights reserved. Patch panels The rear of the patch panel has network cables that are punched down. The front of the patch panel has a factory- terminated interface of some type into which patch cords are inserted.

12 © 2002, Cisco Systems, Inc. All rights reserved. Patching Patching is the term used when connecting two devices with pre- fabricated patch cords.

13 © 2002, Cisco Systems, Inc. All rights reserved. Cross-connecting Cross-connecting is the term used for the interconnection of networks or the connection of information outlets or jacks to network equipment. Cross-connect wire is punched down directly on the punch down termination panels rather than using a patch cord.

14 © 2002, Cisco Systems, Inc. All rights reserved. Terminating copper media There are many types of connectors used to terminate copper media: RJ-45 for Category 5, 5e, and 6 RJ-11 for Category 3 RJ-48 for T-1 lines BNC and F-type for coaxial cabl STP-A for STP cable Connectors for termination blocks

15 © 2002, Cisco Systems, Inc. All rights reserved. RJ-45 wiring schemes TIA/EIA T568A or T568B wiring scheme should be used for all RJ-45 plugs and jacks. In retrofit projects, use the existing scheme. In North America, the most common wiring scheme for networks is T568B. T568A is generally only used by its creator – AT&T.

16 © 2002, Cisco Systems, Inc. All rights reserved. RJ-45 wiring schemes

17 © 2002, Cisco Systems, Inc. All rights reserved. Terminating fiber-optic media Fiber-optic terminations require special and sometimes expensive equipment, specialized training, and considerably more time than copper. The ends must be cleanly cut and scratch- free.

18 © 2002, Cisco Systems, Inc. All rights reserved. TIA/EIA 598A wiring scheme The wiring scheme for fiber-optic cable is specified in TIA/EI 598A. – Try Ring color mnemonics, followed Tip color mnemonics, followed by “Racing Attention” 1 Blue7 Red 2 Orange8 Black 3 Green9 Yellow 4 Brown10 Violet 5 Slate11 Rose 6 White12 Aqua

19 © 2002, Cisco Systems, Inc. All rights reserved. Color coded fiber-optic cables Fiber-optic cables can be identified by the color of the jacket. Single-mode cables, used for jumpers or patch cords, are yellow. Multimode cables are orange.

20 © 2002, Cisco Systems, Inc. All rights reserved. Fiber-optic jumper and patch cables Fiber-optic jumpers are used to interconnect equipment. Fiber-optic patch cables are used for connecting one cable to another.

21 © 2002, Cisco Systems, Inc. All rights reserved. Fiber-optic connectors SC Reference Slide Reference Slide ST Reference Slide Reference Slide FC Reference Slide Reference Slide MT-RJ, LC, MTP Reference Slide

22 © 2002, Cisco Systems, Inc. All rights reserved. Fiber-optic splicing Splicing is joining two pieces of fiber-optic cable. There are two methods used to splice fiber-optic cable: mechanical and fusion.

23 © 2002, Cisco Systems, Inc. All rights reserved. Mechanical splicing The mechanical splice connector provides precision alignment so that the cores of the two fibers are aligned as close to one another as physically possible. Any misalignment, no matter how small, will increase attenuation or loss of signal. Less expensive option to fusion splicing.

24 © 2002, Cisco Systems, Inc. All rights reserved. Fusion splicing Fusion splicing is the actual welding of the optical fibers to one another. Light is injected into one of the fibers. The other fiber is adjusted until the strongest beam of light is received in the other fiber. Then the fibers are fused together. More expensive yet more precise.