FUNDAMENTAL BEHAVIOR OF COMPOSITE MEMBERS UNDER FIRE LOADING

Slides:



Advertisements
Similar presentations
Codes and Standards Future Work
Advertisements

James Kingman, MEng Graduate1 Konstantinos Tsavdaridis, Lecturer1
A Comparison of Numerical Methods to Predict the Progressive Collapse of Lightweight Aluminium Vessels Simon Benson, Jonathan Downes, Robert S. Dow Newcastle.
Cracking, Deflections and Ductility Code Provisions and Recent Research October 2006 Serviceability and Ductility The Other Limit States.
An Experimental Study and Fatigue Damage Model for Fretting Fatigue
4 Pure Bending.
Beams and Frames.
Experimental & Analytical Studies of Drilled Shaft Bridge Columns Sandrine P. Lermitte, PhD Student Jonathan P. Stewart, Assistant Professor John W. Wallace,
Prediction of Load-Displacement Curve for Weld-Bonded Stainless Steel Using Finite Element Method Essam Al-Bahkali Jonny Herwan Department of Mechanical.
2o Ciclo de Palestras em Engenharia Civil de Novembro de 2003 Universidade Nova de Lisboa-Centro de Investigaçao em Estruturas e Construção-UNIC.
Buckling Critical Load Considerations
CM 197 Mechanics of Materials Chap 14: Stresses in Beams
FUNDAMENTAL BEHAVIOR OF COMPOSITE MEMBERS UNDER FIRE LOADING Amit H. Varma Assistant Professor School of Civil Engineering, Purdue University Contributors:
FUNDAMENTAL BEHAVIOR OF CFT BEAM- COLUMNS UNDER FIRE LOADING Amit H. Varma, Sandgo Hong Purdue University 2005 ASCE Structures Congress New York City,
FUNDAMENTAL BEHAVIOR OF CFT BEAM- COLUMNS UNDER FIRE LOADING Amit H. Varma, Sandgo Hong Purdue University 2005 ASCE Structures Congress New York City,
LRFD-Steel Design 1.
10 Pure Bending.
COLUMNS. COLUMNS Introduction According to ACI Code 2.1, a structural element with a ratio of height-to least lateral dimension exceeding three used.
1. By Dr. Attaullah Shah Swedish College of Engineering and Technology Wah Cantt. CE-401 Reinforced Concrete Design-II.
Fatigue in Concrete Structures Raquib Ahsan, Ph.D. Professor Department of Civil Engineering BUET.
Mechanical Behavior of Recycled PET Fiber Reinforced Concrete Matrix (Paper Code: 15FR ) Dr. C. Marthong and Dr. D. K. Sarma National Institute.
Ömer O. Erbay & Ahmet Çıtıpıtıoğlu 25 April 2008
University of Palestine
T.M.F.T: Thermal Mechanical Fatigue Testing
NEESR: Near-Collapse Performance of Existing Reinforced Concrete Structures Presented by Justin Murray Graduate Student Department of Civil and Environmental.
Static Pushover Analysis
Direct Strength Design for Cold-Formed Steel Members with Perforations Progress Report 2 C. Moen and B.W. Schafer AISI-COS Meeting August 2006.
Poisson’s Ratio For a slender bar subjected to axial loading:
Civil and Environmental Engineering Departments
Workshop at Indian Institute of Science 9-13 August, 2010 Bangalore India Fire Safety Engineering & Structures in Fire Organisers:CS Manohar and Ananth.
Jean Claude Dotreppe, Thi Binh Chu, Jean Marc Franssen University of Liège, Belgium 3d fib International Congress 2010 – Washington D.C « Think Globally,
1 NEESR Project Meeting 22/02/2008 Modeling of Bridge Piers with Shear-Flexural Interaction and Bridge System Response Prof. Jian Zhang Shi-Yu Xu Prof.
©Teaching Resource in Design of Steel Structures IIT Madras, SERC Madras, Anna Univ., INSDAG 1 COMPOSITE FLOORS - II.
ELASTIC BUCKLING OF STEEL COLUMNS UNDER THERMAL GRADIENT Christos T. Tsalikis ¬ Efthymios K. Koltsakis ¬ Charalampos C. Baniotopoulos Institute of Metal.
EFFECTS OF MULTIPLE HEAT STRAIGHTENING REPAIRS ON THE STRUCTURAL PROPERTIES AND FRACTURE TOUGHNESS OF BRIDGE STEELS Keith Kowalkowski, Graduate Assistant.
Seismic of Older Concentrically Braced Frames Charles Roeder (PI) Dawn Lehman, Jeffery Berman (co-PI) Stephen Mahin (co-PI Po-Chien Hsiao.
Workshop at Indian Institute of Science 9-13 August, 2010 BangaloreIndia Fire Safety Engineering & Structures in Fire Organisers: CS Manohar and Ananth.
HEAT TRANSFER FINITE ELEMENT FORMULATION
Second Order Analysis In the previous classes we looked at a method that determines the load corresponding to a state of bifurcation equilibrium of a perfect.
Task 2.2 – Identification of most suitable face-sheets and optimization of panel properties Duration: month 1 to month 12 Partners involved: MOTULAB (WP.
COMBINED LOADING.  Analyze the stress developed in thin-walled pressure vessels  Review the stress analysis developed in previous chapters regarding.
Buckling Capacity of Pretwisted Steel Columns: Experiments and Finite Element Simulation Farid Abed & Mai Megahed Department of Civil Engineering American.
Two loading Conditions
CAD and Finite Element Analysis Most ME CAD applications require a FEA in one or more areas: –Stress Analysis –Thermal Analysis –Structural Dynamics –Computational.
Towards a Direct Strength Method for Cold-Formed Steel Beam-Columns
Lecture 1 Stress 16 July 2007 ENT 450 Mechanics of Materials Dr. Haftirman 1 ENT 450 MECHANICS OF MATERIALS (MoM) RC. Hibbler Lecture: DR. HAFTIRMAN Teaching.
EGM 5653 Advanced Mechanics of Materials
Kenneth O’Neill Experimental Investigation of Circular Concrete Filled Steel Tube Geometry on Seismic Performance.
Moisture Diffusion and Long-term Deformation of Concrete
HEAT TRANSFER Problems with FEM solution
INTRODUCTION Due to Industrial revolution metro cities are getting very thickly populated and availability of land goes on decreasing. Due to which multistory.
AXIAL LOAD CAPACITY OF CELLULAR LIGHTWEIGHT CONCRETE-FILLED STEEL SQUARE TUBE COLUMNS Jaksada THUMRONGVUT Department of Civil Engineering, Rajamangala.
Bassam A. Izzuddin* and Bassam A. Burgan†
超臨界CO2在增強型地熱系統儲集層中取熱之研究-子計畫三 CO2在增強型地熱系統取熱模型之建構及效能分析
M. Z. Bezas, Th. N. Nikolaidis, C. C. Baniotopoulos
NSM LAB Net Shape Manufacturing Laboratory
Poisson’s Ratio For a slender bar subjected to axial loading:
Pure Bending.
Christopher R. McGann, Ph.D. Student University of Washington
Thermal analysis Friction brakes are required to transform large amounts of kinetic energy into heat over very short time periods and in the process they.
Poisson’s Ratio For a slender bar subjected to axial loading:
CE 808: Structural Fire Engineering SAFIR - Computer Program
4 Pure Bending.
Nikhil Keshav Raut Michigan State University
Reinforced Concrete Design-I Design of Axial members
CE-401 Reinforced Concrete Design-II
Fire Resistance of Steel Structures
Effect of Location of Axial Restraint on Beam-Columns behavior in Fire
Poisson’s Ratio For a slender bar subjected to axial loading:
4 Pure Bending.
Presentation transcript:

FUNDAMENTAL BEHAVIOR OF COMPOSITE MEMBERS UNDER FIRE LOADING Amit H. Varma Assistant Professor School of Civil Engineering, Purdue University Contributors: Victor Hong, Ph.D. Student at Purdue University Guillermo Cedeno, Ph.D. Student at Purdue University Jarupat Srisa-Ard, M.S. Student at Michigan St. Univ.

PRESENTATION OUTLINE Current Knowledge Base and Issues Research Goals and Objectives Behavior of Composite CFT Columns Under Fire Loading Analytical models, investigations, and findings Need for fundamental measures of behavior under fire loading Analytical investigations of fundamental behavior Experimental investigations of fundamental behavior Conclusions so far Future research needs and capabilities

CURRENT KNOWLEDGE BASE Current building codes emphasize prescriptive fire resistant design provisions that are rooted firmly in the standard ASTM E119 fire test of building structure components. The standard fire test determines the fire resistance rating FRR of structural components for comparative purposes. It does not provide knowledge or data of the fundamental behavior of structural components that can be used to calibrate analytical models. This design paradigm has been challenged by several engineers and researchers over the years. More recently, NIST BFRL researchers have conducted an exhaustive investigation of the 9/11 WTC collapse. They have developed twenty-nine major recommendations for future work.

ISSUES Three of these recommendations R5, R8, and R9 are extremely important for building design (structural) engineers. R5 - The technical basis for the ASTM E119 standard fire test should be improved. R8 - The fire resistance of structures should be enhanced by requiring a performance objective that uncontrolled building fires result in burnout without local or global failure /collapse. R9.1 – Develop and validate analytical tools, guidelines, and test methods necessary to evaluate the fire performance of the structure as a whole system. R9.2 – Develop performance-based standards and code provisions, as an alternative to current prescriptive design methods, to enable the design and retrofit of structures to resist real building fire conditions. Our current research focuses on R9.1 – because it is my area of expertise as a structural engineer

EXPLORATORY RESEARCH GOALS We initiated an exploratory study (2002) of the fire behavior of structural components to: Develop an understanding of the current knowledge base Develop analytical approaches for predicting and investigating behavior Determine the type of knowledge or data needed to develop and validate analytical models that can be used to investigate the behavior of complete structural systems We selected a structural component to explore these questions Composite concrete filled steel tube (CFT) columns Why? Combines both steel and concrete materials – of interest to industry. Area of significant expertise for the researcher (seismic behavior of CFTs) CFT columns are considered to have good fire resistance due to the presence of concrete Lots of data from various sources.

PRIOR EXPERIMENTAL RESEARCH Standard ASTM E119 fire behavior of CFT columns investigated by researchers in Canada (NRC), China, and Japan Experiments conducted in expensive and specially-built column furnaces in these countries Column placed in the furnace. Fix-end boundary conditions Subjected to axial force Furnace air follows the ASTM E119 T-t curve Columns expand, then contract, and eventually fail mostly by columns buckling No fire protection material needed Lack of clarity regarding loads and boundary conditions achieved in the experiments Experimental results are limited to the overall displacement-time response and temperatures through the section

TYPICAL EXPERIMENTAL BEHAVIOR TYPICAL CFT COLUMNS L > 10 b Expansion Reversal Sustenance Buckling failure Circular as well as square CFTs NRC Researchers in Canada

PRIOR ANALYTICAL MODELS Heat transfer analysis: Finite difference method (FDM) simulations of heat transfer from furnace air to column surfaces, and then from column surfaces through the sections, using temperature dependent thermal properties (Lie and Irwin 1995) Structural analysis: Fiber model simulation of the column buckling behavior. Cross-section modeled using elements with uniaxial s-e-T behavior. Assumptions include: plane sections remain plane, linear curvature variation along column length, no slip, and no transverse interaction between the steel and concrete. No basis presented for making these simplifying assumptions Such models do not provide knowledge of fundamental behavior or complex stress and strain states at elevated temperatures

ANALYTICAL APPROACH Need a more general and more robust analytical approach to model the fire behavior of structural members. We use a three step sequentially coupled analytical approach, where the results from each step are required to continue the analysis in the subsequent step. Step I - Fire Dynamics Analysis is conducted to simulate the convection and radiation heat transfer from the fire source to the surfaces of the structural component. It is conducted using FDS, which is a program developed by NIST BFRL researchers. Step II – Nonlinear Heat Transfer Analysis is conducted to simulate the heat transfer through the section and along the length. It is conducted using 3D finite element models and nonlinear temperature-dependent thermal properties

ANALYTICAL APPROACH Step II – Nonlinear Heat Transfer Analysis (continued) The results from Step I (surface T-t curves) serve as thermal loads The results from Step II include the temperature histories (T-t) for all nodes of the finite element model Step III – Nonlinear Stress Analysis is conducted to determine the structural response of the component for the applied structural and calculated thermal loads. It is conducted using 3D finite element meshes that are identical or similar to the heat transfer analysis meshes, and nonlinear temperature -dependent material models The nodal temperature histories from Step II define the thermal loads for this analysis

ANALYTICAL MODELING CFT columns tested by researchers from different parts of the world NRC Canada (1-3), Sakumoto et al. from Japan using FR steel (4, 5) Han et al. from China (6-10) Column   Cross-Section Length fy f'c Load Eccentricity Fire (mm x mm x mm) (mm) Re-bar (MPa) (kN) Protection 1 200x200x6.35 3810 4 x 16 mm 350 47 500 - 2 250x250x6.35 1440 3 300x300x6.35 4 x 25 mm 2000 4 300x300x9 3500 357.9 2020 5 37.5 1350 ceramic 6 300x200x7.96 341 49 2486 spray-type 7 300x150x7.96 1906 8 219x219x5.30 246 18.7 950 9 10 350x350x7.70 284 2700 1670 52.5

Results from Step 1 FIRE DYNAMICS ANALYSIS FDS model of the furnace. Used to predict the surface T-t curves for 200, 250, and 300 mm CFT columns that were tested at NRC. The FDS predictions compare well with the experimentally measured and FDM predicted T-t curves. FDM is less conservative Surface T-t curves are slightly lower than the ASTM E119 T-t curves The column size (200-300 mm) seems have small influence ASTM E119 FDS Experiment FDM

Results from Step II Heat Transfer Analysis The heat transfer analysis models were developed and analyzed using ABAQUS. The steel and concrete temperature dependent thermal properties  Lie and Irwin (1995) The latent heat of water was included in the model The results from the heat transfer analysis were found to compare well with the experimental results ! 250 mm CFT 300 mm CFT 200 mm CFT

MATERIAL PROPERTIES – T Dependent Temperature dependent thermal and structural material properties were used along with the 3D finite element models These material properties were based on values generally reported in the literature (Lie and Irwin 1995 etc.). 100oC 500oC 600oC 700oC 800oC 400oC Steel s-e-T T=100oC Concrete s-e-T 300oC T=300oC 500oC T=500oC 700oC T=700oC 900oC T=900oC

Results from Step III Nonlinear Stress Analysis Column failure mode at elevated temperatures global buckling and local buckling mixed similar to experiments

Results from Step III Nonlinear Stress Analysis The results from the nonlinear stress analysis seem to have some variation from the experimental results. 200x 200x 6.35mm CFT Fy=350; f’c=47 MPa L=3.8 m; P/Po=15% 250x 250x 6.35mm CFT L=3.8 m; P/Po=30% 300x 300x 6.35mm CFT L=3.8 m; P/Po=33% NRC Column Tests ? X

Results from Step III Nonlinear Stress Analysis Comparisons with experimental results are somewhat reasonable! FR Steel Japanese Column Tests 300x 300x 9mm CFT Fy=358; f’c= --- L=3.5 m; P/Po=80% 300x 300x 9mm CFT Fy=358; f’c=37 MPa L=3.5 m; P/Po=25%

Results from Step III Nonlinear Stress Analysis Tests done by Han et al. in China. Again comparisons have issues. 300x 200x 8mm CFT Fy=341; f’c= 49 L=3.8 m; P/Po=50% 300x 150x 8mm CFT Fy=341; f’c= 49 L=3.5 m; P/Po=45% 219x 219x 5.3mm CFT Fy=246; f’c= 19 L=3.5 m; P/Po=41% 350x 350x 7.7mm CFT Fy=284; f’c= 19 L=3.5 m; P/Po=34% ecc. 350x 350x 7.7mm CFT Fy=284; f’c= 19 L=3.5 m; P/Po=56%

Results from Step III Nonlinear Stress Analysis Authors claim pin end conditions were achieved in the furnace column tests, and then provide the following picture of the buckled specimen PIN FIX

SENSITIVITY ANALYSIS Parametric studies were conducted to determine the sensitivity of column behavior with respect to various parameters: (1) Boundary Conditions (2) Steel and concrete material properties as functions of T (3) Axial load level (4) Geometric imperfections Column behavior at elevated temperatures is too sensitive to end conditions NRC Column 1 NRC Column 2 Inter Fix Pin Pin Inter Fix

SENSITIVITY ANALYSIS Column behavior at elevated temperatures is too sensitive to the applied axial load. Fluctuations in axial load can cause variation The sensitivity of column behavior to elevated temperature material s-e-T models is currently ongoing P P +0.05Po P-0.05Po P-0.10Po P + 0.05Po

FINDINGS FROM EXPLORATORY PROGRAM The three step analytical approach with FDS and 3D finite element models for heat transfer and stress analysis can be used to predict the behavior of members under fire loading. The results from FDS and heat transfer analysis compare favorably with experimental data. The results from stress analysis, however have significant variations. The behavior of columns at elevated temperatures is extremely sensitive to the loading and boundary conditions achieved in the experiments. The experimental results of fire resistance rating  must be considered carefully before any general conclusions are made. The ASTM E119 gets around this situation by saying that the members should be tested with the same boundary conditions as those achieved in a real structure --!

FUNDAMENTAL BEHAVIOR The experimental results from a standard fire test do not provide knowledge of the fundamental behavior of structural members independent of boundary conditions and other issues. We need a more fundamental measure, for e.g., the axial force-moment-curvature P-M-f-T behavior of the composite member at elevated temperatures from fire loading. This P-M-f-T behavior defines the fundamental behavior of the member (sort of like a material s-e-T behavior) and can be used in a variety of ways to: (a) conduct analytical parametric studies (a) develop and calibrate analytical models, e.g., fiber models (c) predict actual member behavior and failure (d) and to design fire proofing.

FUNDAMENTAL BEHAVIOR – Why? For example, the behavior and failure of columns under constant axial load and elevated temperatures from fire loading also depends on the section P-M-f-T response of the failure segment. P M=P d

FUNDAMENTAL BEHAVIOR – Why? Researchers around the world have developed finite element method based computer programs to conduct structural analysis under fire loading. For example, researchers at Liege Univ. (SAFIR), Sheffield Univ. (FEMFAN), Univ. of Manchester, Nat. Univ. of Singapore (SINTEF) Most of these programs use fiber-based or concentrated hinge based beam-column finite elements for modeling the behavior of columns and beam-columns under fire loading These finite elements must be validated (or calibrated) using experimental data and realistic P-M-f-T behavior

ANALYTICAL INVESTIGATIONS The three-step analytical approach was used to investigate the fundamental P-M-f-T behavior of CFT beam-columns subjected to standard fire loading. The effects of various geometric (width b and width-to-thickness b/t) parameters and insulation parameters on the behavior were also evaluated analytically. CFT beam-columns with parameters: Width b = 200 or 300 mm. Width-to-thickness ratio = 32 or 48 Steel tube A500 Gr. B (300 MPa) Concrete strength (f’c=35 MPa) Axial load levels (P=0, 20%, 40%) Thermal insulation thickness (0, 7.5, 13 mm thick)

PRELIMINARY ANALYTICAL INVESTIGATIONS The analytical investigations were conducted on a segment of the CFT beam-columns. The length of the segment was equal to the cross-section width b. It represents the critical segment of CFT column or beam-column subjected to axial and flexural loads and elevated temperatures from fire loading.

CFT WITHOUT INSULATION – THERMAL BEHAVIOR Step 2 – Results from heat transfer analysis Step 1 – Results from FDS Analysis for ASTM E119 T-t curve Surface Temperature =600oC Time = 14.2 mts. Surface Temperature =300oC Time = 5.6 mts.

Structural Response – CFT without ins. Step 3 – P-M-f-T curves for CFT without insulation 2.5E-5 5.0E-5 7.5E-5 10.0E-5 12.5E-5 P/Po=20%, T=20oC P/Po=20%, T=300oC P/Po=20%, T=600oC P/Po=20%, T=900oC P/Po=0%, T=20oC P/Po=0%, T=300oC P/Po=0%, T=600oC P/Po=0%, T=900oC

Findings for CFTs Without Insulation Fire loading results in quick heating of the steel tube (broiling) while the concrete infill remains relatively cooler. Significant portions remain at T< 100oC till much later This relative heating causes rapid reduction in flexural stiffness and strength of the CFT section under fire loading effects This reduction depends primarily on the rise in steel temperature, and is independent of axial load level, width, and other parameters This by itself, may not be a cause of concern unless the demands placed on the CFT without insulation exceed the reduced stiffness and strength at elevated temperatures

CFT WITH INSULATION – THERMAL BEHAVIOR Consider CFTs with some insulation. Assume commonly used insulation materials – gypsum cement The presence of thermal insulation results in a slow increase in the steel surface temperature. Steel surface w/o insulation Steel surface with insulation Insulation thick = 6.5 mm Time=180 mts Insulation thick = 13.0 mm The heating of the composite CFT section becomes more uniform (not broiling)

Structural Response of CFT with Insulation P-M-f-T curves for CFT with b/t=32 Ins. Thick = 13 mm Ins. Thick = 6.5 mm Ambient T=20oC P/Po=0 P/Po=20% P/Po=40% 2.5E-5 5.0E-5 7.5E-5 10.0E-5 12.5E-5 Curvature (1/mm) Ins=13 mm Ins=6.5 mm T=20oC b=200 mm, b/t=32 b=200 mm, b/t=48 b=300 mm, b/t=32 Normalized Strength P-M Interaction P-M-f-T curves for CFT with b/t=48 Ins. Thick = 13 mm Ins. Thick = 6.5 mm Ambient T=20oC P/Po=0 P/Po=20% P/Po=40% 2.5E-5 5.0E-5 7.5E-5 10.0E-5 12.5E-5 Curvature (1/mm)

CFTs with Insulation The insulation thickness becomes the most important parameter influencing P-M-f-T behavior and strength (P-M) under elevated temperatures from fire loading. As expected, CFTs with b/t =48 have greater increase in moment capacity with increase in axial load (below the balance point). This continues to be true at elevated temperatures also. The tube width (b) and width-to-thickness (b/t) ratio do not have significant influence on the P-M-f-T behavior of CFTs at elevated temperatures from fire loading

FAILURE MODE Material inelasticity combined with local buckling produce failure Stress analysis results for CFT with b/t=32, axial load level = 20%, and insulation thickness=6.5 mm (curvature = 12.5 x 10-5 1/mm)

EXPERIMENTAL INVESTIGATIONS Real challenge is to determine this fundamental P-M-f-T behavior of a structural member experimentally. This has never been done before (although a group of researchers from U.K. considered it) Need experimental data to validate the analytical approach and models Need experimental data to show that the fundamental P-M-f-T behavior can be measured in the laboratory – efficiently The experimental investigations are being conducted in two phases: Phase I – focusing on the thermal behavior of CFT beam-columns Phase II – focusing on the structural behavior of CFT beam-columns The results from Phase I will be used to validate or calibrate the nonlinear heat transfer analysis models of the CFT (Step II). The results from Phase II will be used to validate the nonlinear stress analysis models developed in Step III.

HEAT TRANSFER EXPERIMENTS The heat transfer experiments are being conducted on short (36 in. long) CFT stub columns. The specimens are 12 x 12 in. in cross-section with different b/t ratios (32, or 48). The parameters considered in the heat transfer experiments are: Gypsum plaster thickness (0.25 and 0.50 in.) Concrete strength f’c (5 ksi and high strength 10 ksi), and Presence of reinforcement bars. Twelve CFT short stubs were tested by subjecting them to elevated temperatures simulating fire loading. For now, the surface of the gypsum plaster was controlled to follow the ASTM E119 T-t curve. The heating was applied using ceramic fiber radiant heaters. These heaters integrate high temperature iron-chrome-aluminum (ICA) heating element wire with ceramic fiber insulation, and can provide surface temperatures up to 1200oC when placed close (250 mm) to them. They can controlled to follow specified T-t or heat flux-time curves using Watlow F4 PID controllers with communications.

HEAT TRANSFER EXPERIMENTS Test setup and thermocouple layout. Since this is only a heat transfer experiment, there are no loads acting on the CFT Thermocouple locations Concrete pedestal CFT stub Heating equipment 3ft 6” 2” 1” 4” 3” Heated Area

Steel surfaces measured EXPERIMENTAL RESULTS Experimental results indicate that the heating system does an excellent job of subjecting the gypsum surface to the T-t curve Gypsum surface specified Gypsum surface measured Steel surfaces measured CFT 12 x 12 x 3/8 in. A500 Gr.-B, f’c=5 ksi, Gypsum thickness = 0.5 in.

EXPERIMENTAL RESULTS The experimental results included T-t curves measured at various locations (steel surfaces, concrete depths) in the section. A 3D finite element model was built to perform the heat transfer analysis. The results from the heat transfer analysis are compared

EXPERIMENTAL RESULTS Similar results and comparisons were obtained for the twelve short CFT specimens. The experimental results are being used to calibrate the nonlinear heat transfer analysis models – work in progress. HEATERS IN ACTION HEATERS IN ACTION

EXPERIMENTAL INVESTIGATIONS In Phase II, the CFT beam-column specimen is tested by: Applying axial load (15-30% of Po) The axial load is maintained constant over the remaining of the test. The axial loading and hydraulic setup can accommodate movement while maintaining constant axial force. The heating is applied to the segment close to the base of the CFT specimens. The heating is applied using four ceramic fiber radiant heaters that are position around the base segment. The base of the CFT specimens is protected using gypsum plaster that is embedded in metal lath. This is the procedure we used for our experiments The heaters are controlled to subject the gypsum surface to the ASTM E119 T-t curve for now. After two hours of heating, the CFT beam-column is pushed laterally at the top. This causes maximum bending and failure of the heated segment of the base

EXPERIMENTAL INVESTIGATIONS TEST SETUP AXIAL LOADING CFT P LATERAL LOADING H CFT Column BASE

EXPERIMENTAL INVESTIGATIONS PID Controllers Heater in Action HEATERS

EXPERIMENTAL INVESTIGATIONS STATIC PUSHOVER Local buckling failure Local buckling failure End of test. Lateral displacement = 8 in.

SENSOR DISTRIBUTION How to measure deformations at very high temperatures? Close-range photogrammetry combined with digital image processing techniques. This method has been used recently for medical and microstructure investigation type application. High precision digital camera – looking at a target that is on the specimen. The camera and data acquisition acquire images and used digital image processing to compute the x, y, and z movement of the target point. Accuracy can be as high as 0.001 in. depending on the view area (1 in.), lighting condition, etc. Much lower resolutions are possible as sub-pixelation is employed by the software. We are using 8 digital cameras to track and measure the deformations of the heated failure segment at the base of the column. The average curvature and rotation over the segment is calculated using these measurements

SENSOR DISTRIBUTION * Vertical Displacement Camera Sensor Locations 1ft Lateral Displacement Camera Sensor Locations Rotation-meter location Vertical Displacement

EXPERIMENTAL RESULTS CFT 10 x 10 x ¼ in. A500 Gr.-B steel (46 ksi), 5.0 ksi concrete Fire protection with ¼ in. of gypsum Axial load = 15% Po 2 hours of ASTM E119 heating (steel surface T=550oC) Ambient Heated

EXPERIMENTAL RESULTS Comparing M-f-T behavior of the 10 in. CFTs. Curvature obtained from photogrammetric measurements

TEST MATRIX Test matrix includes fourteen total CFT specimens that will be tested at ambient and heated temperatures Parameters being considered: Size of column (b) = 250 and 300 mm. Tube width-to-thickness (b/t) ratio = 32, 48 Axial load level (P=15% or 30% Po) Fire protection thickness (0.25 and 0.50 in.) Some repeat specimens Experiments are ongoing – Complete by Summer 06. Validation of analytical models using experimental results – Complete by Fall 06. Determined the fundamental force-deformation-temperature behavior of composite beam-columns

FINDINGS A unique experimental approach was developed to determine the fundamental behavior of composite CFT beam-columns This approach builds upon years of experimental research, the PIs expertise, and the requirements of the problem The heating approach works well for the application we tested The close-range photogrammetry measurements work well for measuring deformations at elevated temperatures The experimental data needs to be improved with higher rates of cycling.

Where do we go from here? R9.1 – Develop and validate analytical tools, guidelines, and test methods necessary to evaluate the fire performance of the structure as a whole system. In this research we focused on developing an analytical approach and unique experimental approach that can be used to predict the fundamental force-deformation-temperature behavior of members. Analytical fiber beam-column elements can be calibrated to the experimental and analytical data developed using the approach outlined. Then, the validated beam-column elements can be used while predicting the fire performance of structures as whole system