Proportional Counters

Slides:



Advertisements
Similar presentations
General Characteristics of Gas Detectors
Advertisements

Radiation Detection ionization chambers (dosimeters, pulse chambers, particle track chambers) scintillation detectors semiconductor detectors photographic.
Glass Resistive plate chambers for muon Detection
Geiger Counters. Higher Voltage As the voltage increases in a gas detector the ions collected increases. The proportional region ends. –Streamer mode.
GM COUNTER.
Geiger-Muller detector and Ionization chamber
Gaseous Detectors.
Drift velocity Adding polyatomic molecules (e.g. CH4 or CO2) to noble gases reduces electron instantaneous velocity; this cools electrons to a region where.
Radiation Detectors / Particle Detectors
Chapter 3 HV Insulating Materials: Gases Air is the most commonly used insulating material. Gases (incl. air) are normally good as electrical insulating.
History of Particle Detectors
Tracking detectors/1 F.Riggi.
Principles of Radiation Detection
Prototype TPC Tests C. Lu 12/9/98 V = 0. Gas gain test for the low pressure chamber The chamber is constructed with the following parameters: D anode.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
Detectors. Measuring Ions  A beam of charged particles will ionize gas. Particle energy E Chamber area A  An applied field will cause ions and electrons.
Tracking Detectors: Proportional and Drift Chambers
High Energy Detection. High Energy Spectrum High energy EM radiation:  (nm)E (eV) Soft x-rays X-rays K Soft gamma rays M Hard gamma.
Techniques for detecting X-rays and gamma-rays Pair production Creation of elementary particle and its antiparticle from a photon. Occurs only if enough.
GRAND Britni Bethune CROP 2002 G amma R ay A strophysics at N otre D ame The University of Notre Dame is located north of South Bend, Indiana The University.
TRAINING COURSE ON RADIATION DOSIMETRY: Instrumentation 1 – Gas detectors / Part 1 Anthony WAKER, University of Ontario Instutute of Technology Wed. 21/11/2012,
Properties of X-Rays Reference: “Elements of X-ray Diffraction”, 3nd Edition, B.D. Cullity, and S.R. Stock, Prentice Hall, NJ Chapter 1
Jean-Marie Brom (IPHC) – 1 DETECTOR TECHNOLOGIES Lecture 2: gazeous détectors Principle of operation Proportional counters and beyond.
Type of Material: Instrumentation Review
IONIZATION DETECTORS “High Energy Physics Phenomenology”
Particle Detectors for Colliders Ionization & Tracking Detectors
Chapter 30: Nuclear Physics and Radioactivity. Radioactivity Radioactivity is the discentigration of an unstable nuclei. when the nuclei decays the nucleus.
Periodic Table Trends. Atomic Radius As you move down a group, atomic radius increases The number of energy levels increases as you move down a group.
Monday, Mar. 7, 2005PHYS 3446, Spring 2005 Jae Yu 1 PHYS 3446 – Lecture #12 Monday, Mar. 7, 2005 Dr. Jae Yu Particle Detection Ionization detectors MWPC.
June 9, 2008What’s a Drift Chamber? Mac Mestayer Drift Chambers: The Science behind the Art What are they? how do they work? ionization of the gas by particles.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
PHENIX Drift Chamber operation principles Modified by Victor Riabov Focus meeting 01/06/04 Original by Sergey Butsyk Focus meeting 01/14/03.
Calorimeters  A calorimeter is a detector that measures “energy” of the particles that pass through. Ideally it stops all particles of interest.  Usually.
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
TPC R&D status in Japan T. Isobe, H. Hamagaki, K. Ozawa, and M. Inuzuka Center for Nuclear Study, University of Tokyo Contents 1.Development of a prototype.
1 TRD-prototype test at KEK-FTBL 11/29/07~12/6 Univ. of Tsukuba Hiroki Yokoyama The TRD prototype is borrowed from GSI group (thanks Anton).
Ionization Detectors Basic operation
Seeing the Subatomic Stephen Miller Saturday Morning Physics October 11, 2003.
2nd RD51 Collaboration Meeting, Paris, October PENNING TRANSFERS Ozkan SAHIN Uludag University Physics Department Bursa -Turkey 2nd RD51 Collaboration.
Experimental and Numerical studies on Bulk Micromegas SINP group in RD51 Applied Nuclear Physics Division Saha Institute of Nuclear Physics Kolkata, West.
Using delay lines on a test station for the Muon Chambers Design considerations (A. F. Barbosa, Jul/2003)
April 22nd, 2004Nigel Lockyer / Young-Kee Kim1 Drift Chambers AMY experiment at e + e - TRISTAN collider CDF experiment B = 3 T B = 1.4 T.
Wednesday, Oct. 18, 2006PHYS 3446, Fall 2006 Jae Yu 1 PHYS 3446 – Lecture #12 Wednesday, Oct. 18, 2006 Dr. Jae Yu 1.Particle Detection Ionization Detectors.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Ion signals with R134a and R134 in a parallel plate proportional counter Edwin Norbeck, J. E. Olson, Y. Onel University of Iowa For Sec. DH-3 of DNP06.
2002 LHC days in Split Sandra Horvat 08 – 12 October, Ruđer Bošković Institute, Zagreb Max-Planck-Institute for Physics, Munich Potential is here...
Xe-based detectors: recent work at Coimbra C.A.N.Conde, A.D. Stauffer, T.H.V.T.Dias, F.P.Santos, F.I.G.M.Borges, L.M.N.Távora, R.M.C. da Silva, J.Barata,
03/21/2005Michael Spitznagel (MIT)Page 1 The Babar Drift Chamber Michael Spitznagel Massachusetts Institute of Technology.
Ion signals with R134a and R134 in a parallel plate proportional counter Y. Onel, E. Norbeck, J. E. Olson University of Iowa For HCAL meeting at Fermilab.
Özkan ŞAHİN & Tadeusz KOWALSKI Uludağ University, Physics Department, Bursa – TURKEY Faculty of Physics and Applied Computer Science, AGH University of.
MPGD (RD-51) Workshop Nikhef, Amsterdam, April Penning Effect on Gas Amplification Factor Ozkan SAHIN Uludag University Physics Department.
Chapter V Radiation Detectors.
A.Ochi Kobe University MPGD2009 Crete 13 June 2009.
Group Meeting TPC 的基本原理 S.C.CHO.. TPC 的介紹 ionization electrons drift  wire chambers  avalanches position dependence of the induced signal  the point.
Penning transfers: survey of available data, life-time of excited states, pressure dependence Ozkan SAHIN Uludag University Physics Department Bursa -TURKEY.
Gas Electron Multiplier
Lesson outline Atomic size (radius) trends Ionization energy trends Ions Ions Electron affinity and electronegativity activity Electron affinity trends.
PPAC Jonathan Olson University of Iowa Thesis Defense 8 April 2005.
Thorsten Lux. Charged particles X-ray (UV) Photons Cathode Anode Amplification Provides: xy position Energy (z position) e- CsI coating 2 Gas (Mixture)
E.B. Holzer BLM Meeting: Q & A March 20, Questions and Answers.
Part-II Wire type detectors 1. Single wire counters.
PCS352 LAB #1 Characteristics of a Geiger Counter
High Voltage Engineering Insulation: Gasious dielectric
Dr: Mohamed Afifi By Lecturer Radiological Science
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
Ion Detectors and The Proportional Detector
Ionization detectors ∆
Factors Limiting the Linearity of Response of Tissue Equivalent Proportional Counters Used in Micro- and Nano – Dosimetry T.Z. Kowalski i AGH, University.
PHYS 3446 – Lecture #16 Monday ,April 2, 2012 Dr. Brandt
Presentation transcript:

Proportional Counters

Amplifying Field Gas counters at the ionization plateau collect virtually all ion pairs produced. At higher field the electrons gain energy to ionize other atoms. More electrons than initial count of ion pairs Gas amplification I + E - V

Avalanche Many electrons reach the anode for each initial pair. Typically 104 electrons An “avalanche”

Proportional Region Ionization chambers at increased voltage move from an ionization plateau to the proportional region. Counters operating in this region are proportional counters.

Cylindrical Chamber Cylindrical geometry is common for proportional counters. Grounded outer cathode High voltage anode The avalanche is limited to a region near the wire. I + - V

Single Track A single track in a chamber creates many avalanches. All contribute to one pulse Timing is based on first avalanche arrival. Usually nearest point in the field. Accurate time-to distance conversion requires uniform field.

Multiwire Proportional Chamber An array of proportional readout wires can be placed in an array. Invented in 1968 by Georges Charpak Used in many discoveries Received the 1992 Nobel Prize Provides excellent position resolution for charged particle tracks.

Gas Gain Gain in the proportional region is exponential with the wire radius a. The Townsend coefficient a depends on the field E. Adjusted by pressure P For 90% Ar, 10% CO2 A = 14 / (cm-Torr) B = 180 V/(cm-Torr)

Parallel Cathode Chamber A parallel plate chamber may have a single anode wire at center. The cathodes are at high positive voltage Vp compared to the case. 2-3 kV The anode is at a higher voltage Vw compared to the case and wire. 4-5 kV grounded shell cathode pads anode wire D0 central muon drift cell

Equipotentials

Gain Comparison The gas gain can be measured by comparing pulse height to voltage difference. Field approximated by cylindrical formula. Expect 204 V for factor of e 250 V yields factor of e

Drift Velocity The important function of a proportional wire chamber is to measure the distance. Particle to wire Need drift velocity The drift velocity also is a factor of the voltage difference.

Drift Linearity Conversion of time to distance is easiest with strong linearity. Particles are measured externally and compared to test cell. At right, noise dominates over non-linearity.

Drift Residuals With multiple drift cells resolution can be determined through residuals. Three displacements Ideal residual equals 0 s = 0.31 mm

Cathode Pads Measurement along the length of the wire gives a third dimension. Timing on wire gives 9 cm to 28 cm resolution Dividing the charge on the pads acts like a vernier to subdivide the longitudinal coordinate. Repeat pattern longer than wire resolution.

Charge Ratios The signal is not as linear in this coordinate.

Pad Residuals Resolution is improved by staggering the phase of the pad pattern. Residuals can be applied compared to get resolution. External wire chambers used for figure at right s = 2.7 mm

Gas Fill The avalanche relies in electrons moving toward the anode. Electronegative gases like O2 pick up electrons. O2- drifts toward anode No avalanche Preferred gases are noble gases and hydrocarbons Hydrocarbons are flammable Noble gases excite and emit photons Gas mixes can quench photons and extra electrons but remain non-flammable

Oxygen Contamination Oxygen is an electronegative impurity. Reduced gain Increases with impurity Equivalent to 110 V drop at wire Gain also decreases with distance. Greater attachment of ions

Water Contamination Water added to the gas causes non-linearities to the drift times. Electronegative impurity 3000 ppm at left Different than O2 Effect of water is dependent on the field strength.