Preparation of b Scan Jianchun Wang Syracuse University CLEO Meeting 04/13/02
Jianchun (JC) Wang2 People Involved Basit Athar, Raja Nandakumar, Jianchun Wang Sheldon Stone, John Yelton, Steve Blusk David Kreinick, Jean Duboscq Others
04/13/02Jianchun (JC) Wang3 Motivation of b Study See February’s talk by JC/Sheldon b lifetime, mass precision (current: 9 MeV), absolute branching ratio Necessary for determining Vcb via b c l Provide input to hadron collider b experiments for Vcb, production rate, etc … This is possible if the b b cross-section is large enough
04/13/02Jianchun (JC) Wang4 Events at b Threshold We hope to have 50 pb for b b pair production. For the study, we use MC simulated events for this portion. The contribution from udsc is similar to that of (4S), with decreasing of cross-section due to CM energy. We use off-resonance data here. Most of bb events produce B mesons. We use on-4S resonance data ( subtracted by off-resonance data ) for this part, with cross-section adjusted to 200pb.
04/13/02Jianchun (JC) Wang5 Signature of b Events It has BB-like event shape ( we require R2<0.2 to reject continuum background). The c production rate is very large ( ~ 100% per b, compared to 6.4% per B). Hence counting number of reconstructed c is a direct tool. The proton and lepton production rate is also high, and reconstruction efficiency is big. So requiring both proton and lepton in same event is even better. We also count number of proton, and hadronic event in the scan.
04/13/02Jianchun (JC) Wang6 c Decay Modes 0.27 1.3 0.27 0.8 0.26 1.3 0.27 0.8 0.3 1.0pK 0.39 0.7pK 0.8 0.39 0.26 1.0pK 0.8 0.39 0.6pK 2 ( 0.02 ) 1.3pK 1 Br Br(pK ) Measured Eff ( ) Estimated Efficiency Br (%)Modes Not all modes will be used in scan, But most of them can be used in further study
04/13/02Jianchun (JC) Wang7 Brief Selection Criteria Good tracks. P/K/ : Dedx, Grand LL (combine Dedx, RICH info). Electron: Dedx, X925, E/P, Grand LL. Muon: Dedx, Mudepth. : X925, Barrel, no track matching, cos CM. K S : Fit quality(prob>0.01), Distance(r- ) > 2mm. : Fit quality(prob>0.01), Distance(r- ) > 1mm.
04/13/02Jianchun (JC) Wang8 Decay Mode pK Scaled to 12 pb . Sum of three sources: b b pair, BB pair, and udsc continuum. About 20 c from b can be seen. M pK (GeV) Number of Entries / 2 MeV
04/13/02Jianchun (JC) Wang9 Decay Modes PKs and Number of Entries / 2 MeV M pKs (GeV) M (GeV) Two modes add 23% more to pK mode
04/13/02Jianchun (JC) Wang10 Sum of Three Modes S/ S+N Background C signal Sum pK S PK Budsc bb B bb
04/13/02Jianchun (JC) Wang11 Proton Lepton Event Require at least one muon or electron in the event. With R2 < 0.2 cut. The efficiency for b b event is 17%. With 12 pb , reconstruct: from b b events. 80.3 from udsc continuum. 30.1 from BB events. S/ S+N = 7.1. XP p Number of Entries / 0.01
04/13/02Jianchun (JC) Wang12 Proton Lepton Event Number of Entries / 0.01
04/13/02Jianchun (JC) Wang13 Proposed Scan Plan At 6 10 32, we expect 16 pb /day. 12 pb per point, total 27 points. 36pb (equivalent to 3 points) at MeV. With 6 MeV interval, scan 7 points till ~11270 MeV. Take 1 point at the end of the scan region (11380 MeV). By then we should have enough information to decide where to go next. Should we find a resonance or a large cross-section point, we will stop the scan and take as much data as possible at that point.
04/13/02Jianchun (JC) Wang14 Computation Resources We expect to have useful information in 24 hours. David Kreinick and Jean Duboscq estimated the CPU consumption and allocate enough computers for the scan. Methods to reduce CPU burden: tighter filter, fast RICH algorithm, … Save PDS data on disk: ~ 64GB. Save only “hot-store” information.
04/13/02Jianchun (JC) Wang15 Beam Condition Hello, A few minutes ago we began collecting our first collisions at 5.6 GeV. Luminosity at 268 (10**30) - not too bad for the first fill. Crate 5 on DR went thru major surgery today during access so we are still evaluating its performance. I'll let you know how things go. Dan Dan Cronin-Hennessy message (03/20/02)
04/13/02Jianchun (JC) Wang16 What’s Next? Possible things to do with b data sample Combine c with a pion or rho to measure b mass. Inclusive semileptonic decay b c l X Measure b b production with double reconstruced c. Measure b b production with proton lepton ( this requires good MC). …
04/13/02Jianchun (JC) Wang17 Tuning Decay Table DECAY LAMB CHANNEL NUEB E- LAMC CHANNEL NUMB MU- LAMC CHANNEL LAMC PI- CHANNEL LAMC RHO- CHANNEL LAMC A1- CHANNEL LAMC DS- CHANNEL LAMC DS*- CHANNEL ETAC LAM CHANNEL PSI LAM CHANNEL LAMC PI+ PI- PI- CHANNEL LAM K0 PI+ PI+ PI- PI- CHANNEL P+ D0 PI- CHANNEL LAMC *DU* CHANNEL SIGC+ *DU* CHANNEL CCS1 *DU* CHANNEL P+ *DU* CHANNEL CSU1 *DU* ENDDECAY With reference to B decays, Steve adjusted the decay table. The effect to the two estimations presented here may be small. And we are checking on this.
04/13/02Jianchun (JC) Wang18 Acknowledgement We really want to thank following people for their help on the coding: Alan Magerkurth Hanna Mahlke-Krueger Hajime Muramatsu And many others we bugged
04/13/02Jianchun (JC) Wang19 Summary The scan tools are tested and ready. The proton-lepton method is more effective. CPU estimation and resource reallocation is going on. We are mostly ready for the scan.
04/13/02Jianchun (JC) Wang20 Track Selection Criteria Dedx information valid, and 3 consistence. Grand LL: LL(K)-LL(pi)+Nsig(K)**2 – Nsig(pi)**2 RICH valid, P(K)>0.5 Gev, P(p)> 1GeV: Grand LL < - 4 Others: (no RICH), Grand LL < -4 Number of expected hits > 0, and number of hits > half of the expected. Number of expected hits in fit > 0, track fitted, fit not abort. Fit helix valid, track quality valid, track fit, not abort, degreesOfFreedom > 0, D0 < 0.6cm (0.35), Z0 < 5cm.
04/13/02Jianchun (JC) Wang21 Reconstruction of c c pK Br ~ 0.05 ~ = 5.4 MeV
04/13/02Jianchun (JC) Wang22 Missing mass calculation: ( b X Since P is relatively small, and cos is unknown, conventionally the last term is treat as 0. In fact the resolution can be improved by giving cos a fixed value, this is due to the boost of b. Semi-leptonic Mode: b c +
04/13/02Jianchun (JC) Wang23 None-zero cos E CM M b = 140 MeV MC at generator level cos =
04/13/02Jianchun (JC) Wang24 None-zero cos Effect of boost is stronger with more kinetic energy. Reconstruction efficiency depends on the boost mainly due to P >GeV requirement. cos is fixed to of reconstructed event. E CM 2M b (MeV)
04/13/02Jianchun (JC) Wang25 The Effect of Beam Energy E CM 2M b (MeV)
04/13/02Jianchun (JC) Wang26 Full Reconstruction of b c + b c + c + pK E CM M b = 20 MeV E CM = 4.5 MeV M c (GeV) = 3.1 MeV
04/13/02Jianchun (JC) Wang27 The Effect of Beam Energy Sigma of M c (MeV) E CM 2M b (MeV)
04/13/02Jianchun (JC) Wang28 The Effect of Beam Energy E CM 2M b (MeV) M c M b (MeV) Sigma of M c (MeV) E CM 2M b (MeV)