Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK Optimisation of X-ray micro-tomography.

Slides:



Advertisements
Similar presentations
CT Scanning: Dosimetry and Artefacts
Advertisements

Computers and Computed Tomography
Image Reconstruction.
Results/Discussion cont’d. Excluding data past the depth of 10% dose, 91% of points passed. A trend towards over-response was noted in the BANG3-Pro2 dosimeter.
IMAGE QUALITY.
Historical Development
Chapter 8 Planar Scintigaraphy
Energy deposition and neutron background studies for a low energy proton therapy facility Roxana Rata*, Roger Barlow* * International Institute for Accelerator.
Computed Tomography II
SCANCOMEDICAL Computed Tomography SCANCO User Meeting 2005 Dr. Bruno Koller SCANCO Medical AG
IMAGE QUALITY NOISE LINEARITY CROSS-FIELD UNIFORMITY IMAGE ARTIFACTS.
Computed Tomography III
Introduction Radiosensitive polyacrylamide gels (PAG) provide a method of mapping dose distributions in 3D with sub-millimetre resolution [1]. Largely.
BMME 560 & BME 590I Medical Imaging: X-ray, CT, and Nuclear Methods X-ray Imaging Part 1.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Optimisation of X-ray micro-tomography to perform low-dose imaging of highly-dosed gels P.M.Jenneson, E.C.Atkinson, P.Wai and S.J.Doran In 1993, Maryanski.
Introduction A Fricke gel was the first dosimetric system to offer the possibility of making 3-D radiation dose measurements in a totally non-destructive.
Some remaining questions in particle therapy radiation biology Bleddyn Jones University of Oxford 1. Gray Institute for Radiation Oncology & Biology 2.
Introduction Three-dimensional gel dosimetry is a novel method for radiation measurement motivated by the need to verify experimentally the doses produced.
Vertex2002 pCT: Hartmut F.-W. Sadrozinski, SCIPP Initial Studies in Proton Computed Tomography L. R. Johnson, B. Keeney, G. Ross, H. F.-W. Sadrozinski,
Reduced Dose of Proton CT Compared to X-Ray CT in Tissue-Density Variation Sensitivity T. Satogata, T. Bacarian, S. Peggs, A.G. Ruggiero, and F.A. Dilmanian.
Vertex2002 pCT: Hartmut F.-W. Sadrozinski, SCIPP Initial Studies in Proton Computed Tomography L. R. Johnson, B. Keeney, G. Ross, H. F.-W. Sadrozinski,
tomos = slice, graphein = to write
Introduction The effect of air-cavities within the human body, for example in the head and neck regions, present possible sources of error when calculating.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
At the position d max of maximum energy loss of radiation, the number of secondary ionizations products peaks which in turn maximizes the dose at that.
Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough Physics Department, University of Surrey, Guildford, GU2 7XH, UK.
Conventional and Computed Tomography
BIOLOGICAL EFFICIENCY OF A THERAPEUTIC PROTON BEAM: A STUDY OF HUMAN MELANOMA CELL LINE I. Petrović 1, A. Ristić-Fira 1, D. Todorović 1, L. Korićanac 1,
Seeram Chapter 11: Image Quality
COMPUTED TOMOGRAPHY (I) RAD 365 CT - Scan
Basic principles Geometry and historical development
Quality Control Rad T 110.
Dose Distribution and Scatter Analysis
CT Quality Control for CT Scanners. Quality Control in CT A good idea? Yes Required for accreditation? Sometimes Improves image quality? Sometimes Depends.
Introduction to Tomographic Imaging A Brief Introduction to Tomographic Imaging David G. Cory, NW Outline  General.
Medical Image Analysis Medical Imaging Modalities: X-Ray Imaging Figures come from the textbook: Medical Image Analysis, Second Edition, by Atam P. Dhawan,
Computed Tomography Physics, Instrumentation, and Imaging
Copyright © 2013 by Mosby, Inc., an affiliate of Elsevier Inc. All rights reserved. Occupational Radiation Dose Management Chapter 38.
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
Evaluation of the Performance of the Fast Scanning Platform of an OCT System Malcolm Heard 1, Miguel Herrera 1, Geoffrey Ibbott 1 1 Department of Radiation.
Introduction Since 1996 [1], it has been clear that optical computed tomography (CT) represents a viable alternative to MRI scanning of dosimeter gels.
Computed Tomography Q & A
Using Radiation in Medicine. There are 3 main uses of radiation in medicine: Treatment Diagnosis Sterilization.
Paul Sellin, Radiation Imaging Group Time-Resolved Ion Beam Induced Charge Imaging at the Surrey Microbeam P.J. Sellin 1, A. Simon 2, A. Lohstroh 1, D.
S Optical CT scanning of PRESAGE TM polyurethane samples with a CCD-based readout system S J Doran 1*, N Krstajic 1, J Adamovics 2 and P M Jenneson 1 1.
X - RAYS IN DIAGNOSTICS D. Krilov
CT Instrumentation and X-ray system
Factors affecting CT image RAD
Fig. 3 shows how a dose distribution that is initially relatively sharp becomes blurred with time, until after 16 hours, virtually no useful information.
© Jimoid.com 2005 Imaging Basics A medical image is a 2D or 3D distribution of signals which represent properties of an object. The purpose of medical.
Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough Physics Department, University of Surrey, Guildford, GU2 7XH, UK.
BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 1 Biomedical Imaging I Class 5 – Radionuclide Imaging (PET, SPECT), Part 3: Attenuation and Scatter.
AIR CORE SCINTILLATION DOSIMETER SUMMARY We have shown that Cerenkov light can be reduced to a negligible level in scintillation dosimetry by using an.
© Jimoid.com 2005 Ionising Radiation There are two types of radiation; ionising and non-ionising. Radiation Ionising Non-ionising Indirectly ionising (neutral.
Image Quality The capacity to define, measure, and assess image quality is a primarily responsibility of a CT Technologist.
CT IMAGE RECONSTRUCTION  Hounsfield envisioned dividing a slice into a matrix of 3-dimensional rectangular boxes (voxels) of material (tissue). Conventionally,
Conclusions Despite being able to acquire successfully high resolution images of radiation dose, image quality is limited by hardware problems. Upgrading.
Determining Radiation Intensity
Part No...., Module No....Lesson No
S Department of Physics, University of Surrey, Guildford, GU2 7XH, UK
Interaction of x-ray photons (and gamma ray photons) with matter.
RTT 425 Radiation Therapy Physics Radiation Quality, Chapter 4 From Stanton and Stinson: Applied physics for Radiation Oncology.
Purpose N-isopropylacrylamide (NIPAM) polymer gel dosimeters were employed to verify the dose distribution of clinical intensity modulated radiation therapy.
X-Rays Unit 5: Medical Physics. OCR Specification Learning Outcomes: Describe the nature of x-rays Describe how x-rays are produced Describe how x-rays.
Thickness of CZT detector 110 MeV140 MeV DETECTOR A (1 mm CZT + 5 mm CZT) DETECTOR B (1 mm CZT + 10 mm CZT) DETECTOR C (1 mm CZT + 15 mm CZT) A. Generation.
Development of elements of 3D planning program for radiotherapy Graphical editor options  automated enclose of contour  correction of intersections 
IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
Development and characterization of the Detectorized Phantom for research in the field of spatial fractionated radiation therapy. D. Ramazanov, V. Pugatch,
Computed Tomography (C.T)
Presentation transcript:

Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK Optimisation of X-ray micro-tomography to perform low-dose imaging of highly- dosed gels P.M.Jenneson, E.C.Atkinson, P.Wai and S.J.Doran School of Electronics and Physical Sciences, Department of Physics, University of Surrey, Guildford, Surrey, GU2 7XH, UK

Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK Density change dose mapping Radiation induced changes include, liberation of ions and induced colour changes (optical CT), polymer cross-linking effects (MRI), changes in density (MRI and X-ray CT). Density change of a polyacrylamide gel (PAG) exposed to 50 Gy is g/cm 3 to g/cm 3. An X-ray micro-tomography system has been designed that is optimised for low dose (~0.054 Gy) imaging of PAGs with a spatial resolution of <100  m.

Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK Proton Eye Radiotherapy MeV protons are used to treat tumours on the rear of the eye (Clatterbridge Centre for Oncology, UK has a 62 MeV proton beam). The lateral spread and ionisation of 50 MeV protons can be modelled using SRIM Bragg peak is at 22mm and the lateral spread of ions is also show. The deposited dose is a complex three- dimensional distribution.

Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK X-ray micro-tomography High-spatial resolution (<100um) necessary for examining 3-D dose distributions in proton therapy. The system is low in image artefact, such as refraction and diffraction which affects optical tomographic methods. Apparatus is compact, bench top size, and relatively low cost. Ease of sample preparation and analysis, using PAG or MAGIC gel dosemeters.

Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK X-ray micro-tomography A mini-focus X-ray source (Oxford XTF5011 :- Ag target, 50kVp 0.5mA, 100um focal spot or an Oxford series 1500 :- W target, 80kVp, 0.25mA, 33um focal spot) is used in conjunction with a 100mm diameter X- ray image intensifier (Hamamatsu C7336). The sample can be rotated and moved perpendicular to the beam axis.

Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK Image quality versus imaging dose The optimum energy for the reconstruction of tomographic images can be found using the “sensitivity factor” as a guide, D = object diameter  = linear attenuation coefficient This relationship is formed by combining the equations for Nyquist angular sampling criteria and the total theoretical time for a tomographic acquisition. The most accurate images (i.e. when the “sensitivity factor” is at a minimum) are obtained between 1 to 6 Mean Free Path lengths for the X-rays in the sample and optimum at 3 MFP.

Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK Image quality versus imaging dose The mean free path radiation length (the inverse of the linear attenuation coefficient) versus energy for several thicknesses of gelatin where plotted For 25mm of gelatin the optimum source energy would be 13 keV and 27 keV.

Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK Image quality versus imaging dose By using a mini-focus X-ray tube with a silver-target operated at 50kVp and using a 50um palladium, a quasi-monoenergtic X-ray source can be generated. This reduces the imaging dose and any “beam-hardening” artefact by removing unsuitable energies.

Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK Image quality versus imaging dose The dose to the centre of a sample which is needed to form a tomographic image is, To image a 25mm diameter PAG with a 0.1% contrast a dose of Gy to the centre of a sample is needed. This gives the ability to resolve a change in density from an unirradiated PAG (density = g/cm 3 ) of g/cm 3, corresponding to an irradiation dose contrast of 3.5 Gy. E x = beam energy  = detector efficiency  = plane pixel size h = slice thickness f c = Compton factor  = density of the sample SNR = signal-to-noise ratio d = diameter of reconstruction

Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK Future plans Use X-ray micro-tomography to analyse PAG, MAGIC (and alternative?) polymer gel dosimeters optimised for radiation induced density changes at high doses. To study the dose response of optimised gels to X- ray, gamma and hadron beam irradiations. To map a three-dimensional dose distribution in a “human eye” gel dosimeter phantom for hadron beam radiotherapy treatments.