K-Shell Spectroscopy of Au Plasma Generated with a Short Pulse Laser Calvin Zulick [1], Franklin Dollar [1], Hui Chen [2], Katerina Falk [3], Andy Hazi.

Slides:



Advertisements
Similar presentations
EMISSION AND ABSORPTION SPECTRA. Spectra A spectrum is the pattern formed when a beam of light (EM – radiation) is broken up into its component frequencies.
Advertisements

Instrumental Chemistry
Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation,
Ch6 X-ray Producing X-ray Moseley formula X-ray diffraction
Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
Lecture 20 X-Ray Diffraction (XRD)
Lecture 21 (12/11/2006) X-Ray Diffraction (XRD) Theory and Analytical Technique.
C. McGuffey a, W. Schumaker a, S. Kneip b, F. Dollar a, A. Maksimchuk a, A. G. R. Thomas a, and K. Krushelnick a (a) University of Michigan, Center for.
Ultrafast laser-driven electric field propagation on metallic surfaces Laser-driven proton beams When an intense short-pulse laser is focused down onto.
Frequency and Time Domain Studies of Toluene Adrian M. Gardner, Alistair M. Green, Julia A. Davies, Katharine L. Reid and Timothy G. Wright.
Lawrence Livermore National Laboratory Pravesh Patel 10th Intl. Workshop on Fast Ignition of Fusion Targets June 9-13, 2008, Hersonissos, Crete Experimental.
LCLS Atomic Physics with Intense X-rays at LCLS Philip H. Bucksbaum, University of Michigan, Ann Arbor, MI Roger Falcone, University of California, Berkeley,
Radiation & Photometry AS4100 Astrofisika Pengamatan Prodi Astronomi 2007/2008 B. Dermawan.
KeV HHG and Sub femtosecond K-shell excitation. ( using IR (2.1  m) Radiation Source ) Gilad Marcus The Department of Applied Physics, The Hebrew University,
Atomic X-Ray Spectroscopy Chapter 12 X-ray range  Å to 100 Å Used  0.1Å to 25 Å.
EMISSION SPECTROSCOPIC STUDIES OF LASER-INDUCED GRAPHITE PLASMAS László Nemes Research Laboratory for Materials and Environmental Chemistry, Chemical Research.
Generation of short pulses
Preliminary Results from Titan Divergence Measurements L. D. Van Woerkom Department of Physics The Ohio State University FSC Special Meeting LLNL 4-6 August.
John J. Curry Atomic Spectroscopy Group National Institute of Standards and Technology physics.nist.gov/Divisions/Div842/Gp1/index.html.
UNCLASSIFIED Heat Transport Measurements in Foil Targets Irradiated with Picosecond Timescale Laser Pulses D. J. Hoarty 1, S F James 1, C R D Brown 1,
Kodak RAR 2492 Film Same film as above Integrate ~50 shots for good signal X-ray Imaging Spectroscopy of Ti Foils and Pyramidal Targets Gilliss Dyer, Byoung-Ick.
GEOMETRIC EFFECTS ON EUV EMISSIONS IN M. S. Tillack, K. L. University of California San Diego.
Time resolved images of the x-ray emission from Ti foils and sandwiched Al/Ti/Al foils, in the region between 4.4 and 5.0 keV, show well resolved of K-
Diagnostics for Benchmarking Experiments L. Van Woerkom The Ohio State University University of California, San Diego Center for Energy Research 3rd MEETING.
LCLS Studies of Laser Initiated Dynamics Jorgen Larsson, David Reis, Thomas Tschentscher, and Kelly Gaffney provided LUSI management with preliminary Specifications.
Instrumental Chemistry Chapter 12 Atomic X-Ray Spectroscopic.
Acceleration of a mass limited target by ultra-high intensity laser pulse A.A.Andreev 1, J.Limpouch 2, K.Yu.Platonov 1 J.Psikal 2, Yu.Stolyarov 1 1. ILPh.
W.N. Catford/P.H. Regan 1AMQ 83 Characteristic X-rays and Selection Rules. Characteristic X-rays: are emitted by atoms when electrons make transitions.
Hot Electron Behaviors Relevant to Fast Ignition K. A. Tanaka 1,2, H. Habara 1,2, R. Kodama 1,2, K. Kondo 1,2, G.R. Kumar 1,2,3, A.L. Lei 1,2, K. Mima.
Diffraction Applications Physics 202 Professor Lee Carkner Lecture 28.
Photoelectron Spectroscopy Lecture 7 – instrumental details –Photon sources –Experimental resolution and sensitivity –Electron kinetic energy and resolution.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
X-ray Diffraction Outline Crystals and Bragg Diffraction
Bremsstrahlung Temperature Scaling in Ultra-Intense Laser- Plasma Interactions C. Zulick, B. Hou, J. Nees, A. Maksimchuk, A. Thomas, K. Krushelnick Center.
Comparison of Stark Broadening and Doppler Broadening of Spectral Lines in Dense Hot Plasmas By Michael Zellner.
2D Position Sensitive Detector for Plasma diagnosis
COST Meeting Krakow May 2010 Temperature and K  -Yield radial distributions of laser-produced solid-density plasmas Ulf Zastrau X-ray Optics Group - IOQ.
 How does the wavelength of a light beam and the size of a slit it is going through control the amount of diffraction? DO WORK STOP.
Neutron Generation Using Ultra-Intense Laser Plasma Interactions C. Zulick 1, F. Dollar 1, J. Davis 2, V. Chvykov 1, G. Kalintchenko 1, A. Maksimchuk 1,
6- PRENTICE HALL ©2007 Pearson Education, Inc. Upper Saddle River, NJ CRIMINALISTICS An Introduction to Forensic Science, 9/E By Richard Saferstein.
Chapter 12 Atomic X-Ray Spectroscopy
Angular distribution of fast electrons and
1 Components of Optical Instruments Lecture Silicon Diode Transducers A semiconductor material like silicon can be doped by an element of group.
The Particlelike Properties of Electromagnetics Radiation Wei-Li Chen 10/27/2014.
Spectroscopy and Astronomy Erin Wood, M.S., M.S. Neil Marks, B.A.
PHYS 430/603 material Laszlo Takacs UMBC Department of Physics
TIME-RESOLVED OPTICAL SPECTROSCOPY OF HIGH-TEMPERATURE PLASMAS M.J. Sadowski  , K. Malinowski , E. Skladnik-Sadowska , M. Scholtz , A. Tsarenko ¤
Yen-Yu Chang, Li-Chung Ha, Yen-Mu Chen Chih-Hao Pai Investigator Jypyng Wang, Szu-yuan Chen, Jiunn-Yuan Lin Contributing Students Institute of Atomic and.
This work was performed under the auspices of the U.S. Department of Energy by the University of California Lawrence Livermore National Laboratory under.
Anisotropic dielectronic resonances from magnetic-dipole lines Yuri Ralchenko National Institute of Standards and Technology Gaithersburg, MD, USA ADAS.
Institute of Atomic and Molecular Sciences, Academia Sinica, Taiwan National Taiwan University, Taiwan National Central University, Taiwan National Chung.
Fast Electron Temperature Scaling and Conversion Efficiency Measurements using a Bremsstrahlung Spectrometer Brad Westover US-Japan Workshop San Diego,
SIMULATIONS FOR THE ELUCIDATION OF ELECTRON BEAM PROPERTIES IN LASER-WAKEFIELD ACCELERATION EXPERIMENTS VIA BETATRON AND SYNCHROTRON-LIKE RADIATION P.
Enhancing the Macroscopic Yield of Narrow-Band High-Order Harmonic Generation by Fano Resonances Muhammed Sayrac Phys-689 Texas A&M University 4/30/2015.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Laboratory photo-ionized plasma David Yanuka. Introduction  Photo-ionized plasmas are common in astrophysical environments  Typically near strong sources.
Photoelectron Imaging of Vibrational Autodetachment from Nitromethane Anions Chris L. Adams, Holger Schneider, J. Mathias Weber JILA, University of Colorado,
Conclusions References 1. A. Galimberti et al., Nucl. Instrum. Meth. A 477, (2002). 2. F. Capotondi et al., Thin Solid Films 484, (2005).
How do we know? Spectroscopy: Experimental Evidence.
Munib Amin Institute for Laser and Plasma Physics Heinrich Heine University Düsseldorf Laser ion acceleration and applications A bouquet of flowers.
Time-Resolved X-ray Absorption Spectroscopy of Warm Dense Matter J.W. Lee 1,2,6, L.J. Bae 1,2, K. Engelhorn 3, B. Barbel 3, P. Heimann 4, Y. Ping 5, A.
Physics of Hot, Dense Plasmas
K-x-ray Emission in Fast O5+ on Ar Collisions
Experiments at LCLS wavelength: 0.62 nm (2 keV)
Chapter 6 INORGANIC ANALYSIS
N2 Vibrational Temperature, Gas Temperature,
X-Ray Spectrometry Using Cauchois Geometry For Temperature Diagnostics
LSP Modeling of Ultra-Intense Lasers on Cone-Coupled Wire Targets:
Interaction of Radiation with Matter
Energy penetration into arrays of aligned nanowires irradiated with relativistic intensities: Scaling to terabar pressures by Clayton Bargsten, Reed Hollinger,
Presentation transcript:

K-Shell Spectroscopy of Au Plasma Generated with a Short Pulse Laser Calvin Zulick [1], Franklin Dollar [1], Hui Chen [2], Katerina Falk [3], Andy Hazi [2], Karl Krushelnick [1], Chris Murhpy [3], Jaebum Park [2], John Seely [4], Ronnie Shepherd [2], Csilla I. Szabo [4], Riccardo Tommasini [2] [1] Center for Ultrafast Optical Science, University of Michigan [2] L-472, Lawrence Livermore National Laboratory [3] Clarendon Laboratory, University of Oxford [4] Space Science Division, Naval Research Laboratory Experimental Setup and Background: The Titan laser, part of the Jupiter Laser Facility at Lawrence Livermore National Laboratory, was used to deliver a 350 joule, 10 ps, 1054 nm laser pulse to a Au target. The absorption of laser energy by the resulting Au plasma results in the production of suprathermal (“hot”) electrons which propagate into the target. The high energy electron beam knocks inner shell electrons from their orbit leaving vacancies which can be replaced by higher energy electrons. The energy released as electrons relax into inner shell vacancies is given off as x-rays (commonly referred to as K-alpha and K-beta radiation) which differ in energy depending on the original shell position of the electron. Summary: The cylindrically bent crystal spectrometer provides an effective way of measuring K-alpha and K-beta x-rays from short pulse laser-matter interactions. The presence of a nanosecond pulse on the rear surface of the gold target increased the K-alpha to K-beta ratio. The plasma conditions inferred by the K-shell x-rays may provide some insight into the production of positrons. Cylindrically Bent Crystal Spectrometer: A hard x-ray spectrometer was used to time-integrate x-ray spectra and prove intensity and energy data. The spectrometer utilized a cylindrically bent quartz crystal to “focus” Bragg diffracted x-rays through a lead slit. The dependence of the Bragg angle on the x-ray energy introduces spatial separation in the x-ray energies which are then resolved on image plate. References: [1] Kneip, S. et al. HEDP (2008) [2] Jiang, Z. et al. Phys. Plasmas (1995) [3] [4] Chung, H. et al. (2008) Electron Shell Diagram Titan Experimental Chamber This work performed under the auspices of the U.S. DOE by LLNL under Contract DE-AC52-07NA27344 and was funded by LDRD #10-ERD-044 Simulation: FLYCHK [4], an atomic NLTE code designed to provide ionization and population distributions, was used to simulate the K-alpha and K-beta spectra for Au targets with varying temperatures and ionization states. Temperature and ionization estimates were calculated with HYADES (a 1-D hydro-code). Image Plate showing Eu Spectra K-Shell Spectra: K-Alpha 1,2 and K-Beta 1,2 transitions were observed over a series of 40 shots with varying target and laser conditions. The observed spectra were consistent with tabulated energies [3] for both cold Au and Eu targets. LineKev Kα240.9 Kα141.5 Kβ147.3 Kβ248.3 Tabulated Values (NIST) LineKev Kα266.9 Kα168.8 Kβ178.5 Kβ280.3 Tabulated Values (NIST) The axial symmetry of the spectrometer allows duplicate information to be recorded on each side of the image plate, providing additional signal and information about the background noise. Second order Bragg peaks from the K- alpha signal are also evident in this image. Higher Energy Spectrometer in the Titan target chamber CAD drawing and schematic of the spectrometer The spectrometer was designed with a 60cm stand off distance which corresponds to a collection angle of approximately 50 mrad. We performed a series of shots in which the backside of the target was pre- heated and pre-ionized with a long pulse laser (3 nanosecond, 1-10 joule). We observed an increase in the ratio of K-alpha to K-beta signal with increasing short pulse laser energy. Abstract: The production of x-rays from electron transitions into K-shell vacancies (K-α/β emission) is a well known process in atomic physics and has been extensively studied as a plasma diagnostic in low and mid Z materials [1-2]. Such spectra from near neutral high-Z ions are very complex and therefore difficult to describe with analytical models. In this experiment a high Z (gold) plasma emission spectrum was measured with a transparent cylindrically bent quartz crystal spectrometer with a hard x-ray energy window ranging from 17 to 102 keV. Using these estimates, FLYCHK was used to establish a better estimate on the plasma conditions by matching the simulated spectra to the observed intensity ratios. Ultimately, this information will be used to establish a connection between the plasma temperature and ionization states and the production of positrons. K β1 K β2 K α2 K α1