J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Coherent Single Particle Imaging (WBS 1.3) J. B. Hastings*

Slides:



Advertisements
Similar presentations
Design and Experimental Considerations for Multi-stage Laser Driven Particle Accelerator at 1μm Driving Wavelength Y.Y. Lin( 林元堯), A.C. Chiang (蔣安忠), Y.C.
Advertisements

Soft X-ray Self-Seeding
Ultrafast Experiments Hao Hu The University of Tennessee Department of Physics and Astronomy, Knoxville Course: Advanced Solid State Physics II (Spring.
X-ray Diffraction. X-ray Generation X-ray tube (sealed) Pure metal target (Cu) Electrons remover inner-shell electrons from target. Other electrons “fall”
The Wave Nature of Light
Spectral Resolution and Spectrometers
Spectral Resolution and Spectrometers A Brief Guide to Understanding and Obtaining the Proper Resolution of the 785 Raman System.
Ultrafast XUV Coherent Diffractive Imaging Xunyou GE, CEA Saclay Director : Hamed Merdji.
LCLS Structural Studies on Single Particles and Biomolecules Janos Hajdu, Uppsala University Gyula Faigel, Institute for Solid State Physics and Optics,
Approaches for the generation of femtosecond x-ray pulses Zhirong Huang (SLAC)
Single Particle X-ray Diffraction - the Present and the Future John Miao Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center.
Tom Fornek LUSI June 17, LUSI UPDATE – June, 2008.
Richard M. Bionta XTOD July 19-21, 2005 UCRL-PRES-xxxxxx X Ray Diagnostics LCLS FAC Meeting Oct. 27, 2005.
James Welch October 30, FEL Commissioning Plans J. Welch, et. al. FEL Commissioning Plans J. Welch, et. al. Accelerator.
Richard M. Bionta XTOD October 12, 2004 UCRL-PRES-XXXXX X Ray Transport, Optics, and Diagnostics, Overview Facility Advisory Committee.
J. B. Hastings LUSI Overview LCLS FAC March 20, 2007 LUSI Overview J. B. Hastings January 2007 Lehman Review Response to Lehman Review.
J. B. Hastings LCLS FAC October 29, 2007 LUSI Overview 1 LUSI Overview J. B. Hastings Science Opportunities Project Description Project.
David Fritz LCLS FAC Meeting Oct. 30, X-ray Pump-Probe Instrument David Fritz Instrument Overview Instrument Layout System.
FLASH Experiments with Photons High intensity laser light in the VUV spectral region Harald Redlin; HASYLAB.
1 A Grating Spectrograph for the LCLS Philip Heimann Advanced Light Source Observe the spontaneous radiation spectrum of the individual undulators Observe.
John Arthur X-Ray Optics October 12, 2004 X-Ray Prototype Optics Specifications John Arthur.
1 Michael Rowen 1 SXR Instrument FAC SXR Instrument Michael Rowen – Engineering Physicist June 9, 2009.
Sébastien Boutet LCLS FAC June Coherent X-Ray Imaging 1 LUSI Coherent X-ray Imaging Instrument Sébastien Boutet – CXI.
Sébastien Boutet LCLS FAC Meeting Oct 30, 2007 Coherent X-ray Imaging1 Coherent X-ray Imaging Instrument Sébastien Boutet Coherent.
Richard M. Bionta X-Ray Transport, Diagnostic, & Commissioning September 22, 2004 UCRL-PRES Two Problems... LCLS Diagnostics.
D. M. Fritz LCLS FAC Meeting April 16, 2007 XPP Instrument X-ray Pump-Probe Instrument D. M. Fritz Pump-probe Experiments System.
R. M. Bionta SLAC November 14, 2005 UCRL-PRES-XXXXXX LCLS Beam-Based Undulator K Measurements Workshop Use of FEL Off-Axis Zone Plate.
PHY 102: Waves & Quanta Topic 8 Diffraction II John Cockburn Room E15)
1 Sébastien Boutet 1 Coherent X-ray Imaging Instrument FAC Meeting, June Coherent X-ray Imaging Instrument Sébastien Boutet.
Chapter 25:Optical Instruments Cameras Homework assignment : Read Chap.25, Sample exercises : 4,21,24,41,43  Principle of a camera ss’ D Intensity of.
J. B. Hastings LUSI DOE Review July 23, 2007 X-ray Optics 1 X-ray Optics J. B. Hastings Beam definition Attenuators Slits Pulse picker.
Chapter 25 Optical Instruments.
Visual Angle How large an object appears, and how much detail we can see on it, depends on the size of the image it makes on the retina. This, in turns,
X-Ray Diffraction Dr. T. Ramlochan March 2010.
EAS Reconstruction with Cerenkov Photons Shower Simulation Reconstruction Algorithm Toy MC Study Two Detector Configuration Summary M.Z. Wang and C.C.
Transverse Profiling of an Intense FEL X-Ray Beam Using a Probe Electron Beam Patrick Krejcik SLAC National Accelerator Laboratory.
Assessing Single Crystal Diamond Quality
Coherent X-ray Diffraction (CXD) X-ray imaging of non periodic objects Campi G., De Caro L., Giannini C., Guagliardi A., Margonelli A., Pifferi A.
John Miao Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center Crystallography without Crystals and the Potential of Imaging Single.
Difference of Optical Path Length Interference Two waves One wave Many waves Diffraction.
1nm R&D plan K. Evans-Lutterodt Contributions from:
Coherent X-ray Diffraction (CXD) X-ray imaging of non periodic objects Campi G., De Caro L., Giannini C., Guagliardi A., Margonelli A., Pifferi A.
1 Fraunhofer Diffraction: Single, multiple slit(s) & Circular aperture Fri. Nov. 22, 2002.
The SPARX FEL Project a source for coherent radiation production in the soft X-ray energy range.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Latifa Elouadrhiri Jefferson Lab Hall B 12 GeV Upgrade Drift Chamber Review Jefferson Lab March 6- 8, 2007 CLAS12 Drift Chambers Simulation and Event Reconstruction.
Status Report particle identification with the RICH detector Claudia Höhne - GSI Darmstadt, Germany general overview focus on ring radius/ Cherenkov angle.
LCLS Facility Planning for LCLS-II. 2 LCLS vs. LCLS-II NowHXU - CuSXU - CuHXU - SCSXU - SC Photon Energy Range (eV)
Peterson xBSM Optics, Beam Size Calibration1 xBSM Beam Size Calibration Dan Peterson CesrTA general meeting introduction to the optics.
Michael Pivovaroff OCT 2005 UCRL-PRES FEL Offset Mirrors LCLS Week * FAC Meeting 26–27 October 2005.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Summer '07 at CLS Small Angle X-Ray Scattering Peter ChenChithra Karunakaran & Konstantine Kaznatcheev.
Sébastien Boutet LUSI DOE Review July 23, 2007 CXI (WBS 1.3) 1 Coherent X-ray Imaging (WBS 1.3) Sébastien Boutet System Specifications.
Sébastien Boutet LUSI DOE Review July 23, 2007 WBS 1.3 Breakout1 Coherent X-ray Imaging (WBS 1.3) Sébastien Boutet System description.
J. B. Hastings LUSI DOE Review July 23, 2007 X-ray Optics 1 X-ray Optics J. B. Hastings Beam definition Attenuators Slits Pulse picker.
Highlights of science of USR Yuhui Dong BSRF, IHEP, CAS 2012/10/29.
At XFELs Joachim Schulz Sample Delivery Methods for Biology Experiments.
SPARCLAB: PW-class Ti:Sa laser+SPARC
Coherent X-ray Imaging Instrument
Experiments at LCLS wavelength: 0.62 nm (2 keV)
RECONSTRUCTED CELL STRUCTURE Jakob Andreasson
X-ray Correlation Spectroscopy (WBS 1.4) Aymeric Robert
Short focal length target area: X-ray & ion sources and applications
Coherent X-ray Imaging WBS 1.3
X-Ray Transport, Optics, and Diagnostics WBS Alan J
Diagnostics Richard M. Bionta, LLNL April 24, 2002
X-ray Pump-Probe Instrument
Optics John Arthur, SLAC & William W. Craig, LLNL April 24, 2002
Coherent X-ray Imaging Instrument WBS 1.3
X-ray Correlation Spectroscopy Instrument
Presentation transcript:

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Coherent Single Particle Imaging (WBS 1.3) J. B. Hastings*

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Science Team Specifications and instrument concept developed with the science team. The team Janos Hajdu, Photon Science-SLAC, Upsala University (leader) Henry Chapman, LLNL John Miao, UCLA Specifications and instrument concept developed with the science team. The team Janos Hajdu, Photon Science-SLAC, Upsala University (leader) Henry Chapman, LLNL John Miao, UCLA

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging A 3D dataset can be assembled from diffraction patterns in unknown orientations Diffraction from a single molecule: FEL pulse Noisy diffraction pattern Combine 10 5 to 10 7 measurements into 3D dataset: ClassifyAverageCombineReconstruct Miao, Hodgson, Sayre, PNAS 98 (2001) Unknown orientation Gösta Huldt, Abraham Szöke, Janos Hajdu (J.Struct Biol, ERD-047) The highest achievable resolution is limited by the ability to group patterns of similar orientation

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Particle injection XFEL beam (focussed, possibly Compressed) Optical and x- ray diagnostics Pixel detector Intelligent beam-stop To mass spectrometer PotentialParticle orientation beam The diffraction imaging interaction chamber and detector arrangement Readout and reconstruction Hartman Wavefront Mask

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Coherent X-ray Imaging Instrument 1 micron KB system 0.1 micron KB system Sample chamber Detector Wavefront sensor

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Detector geometry ‘Hole’ in detector to pass Incident beam Tiled detector, permits variable ‘hole’ size: Ideally the hole is ~ x2 bigger than incident beam at most Dead area at edges of detector tiles limits minimum ‘hole’ size Alternate approach: larger ‘hole’ and a single tile for forward direction Simulations required

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging X-ray optics (1.3.2) Focusing K-B systems for 1 and 0.1 micron foci Be lens for 10 micron focus Slits, attenuators, ‘pulse picker’ Pulse compression optic X-ray optics (1.3.2) Focusing K-B systems for 1 and 0.1 micron foci Be lens for 10 micron focus Slits, attenuators, ‘pulse picker’ Pulse compression optic X-ray Optics

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging X-ray Optics - focusing Two approaches: separate optical components for 10, 1, 0.1 micron focii or a single 0.1 micorn optic and work out of focus for ‘variable’ spot size Separate optics: Ideally wavefront is ‘flat’ Complicated motion for sample chamber-detector system Single optic: Simple ‘translation of sample varies focus’ Wavefront curavture when ‘out of focus, is this harmful? Two approaches: separate optical components for 10, 1, 0.1 micron focii or a single 0.1 micorn optic and work out of focus for ‘variable’ spot size Separate optics: Ideally wavefront is ‘flat’ Complicated motion for sample chamber-detector system Single optic: Simple ‘translation of sample varies focus’ Wavefront curavture when ‘out of focus, is this harmful?

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging X-ray Optics - focusing FEL source Offset mirror pair Monochromator/ pulse- compressor Sample chamber & diagnostics Focusing optics Pixel detector Sample handler Image reconstruction z s ≈ 400 m f 1 µm zdzd Beam- stop Be Lens KB Mirrors 1 µm 0.1 µm f 0.1 µm

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Kirkpatrick Baez (KB) focusing mirrors Mirror system (1 µm and 0.1 µm KB) KB mirrors have produced 50 nm focuses of SR(Yamauchi et al., SRI 2006). Can use bent plane mirrors – plane mirrors most accurate polishing. Achromatic focusing. Use B 4 C as coating Damage resistant Good reflectivity Mirror system (1 µm and 0.1 µm KB) KB mirrors have produced 50 nm focuses of SR(Yamauchi et al., SRI 2006). Can use bent plane mirrors – plane mirrors most accurate polishing. Achromatic focusing. Use B 4 C as coating Damage resistant Good reflectivity

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging KB Pair for 1 μ m focus Grazing angle 0.2 Deg B 4 C coating Horz. Mirror 20 cm Vert. Mirror 10 cm Focal spot size (FWHM in microns) Horz: 0.6 Vert: 0.9

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging KB Pair for 0.1 μ m focus Grazing angle 0.2 Deg B 4 C coating Horz. Mirror 20 cm Vert. Mirror 10 cm Focal spot size (FWHM in microns) Horz: Vert: 0.083

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging X-ray Optics - focusing FEL source Offset mirror pair Monochromator/ pulse- compressor Sample chamber & diagnostics Focusing optics Pixel detector Sample handler Image reconstruction z s ≈ 400 m f Be lens zdzd Beam- stop Be Lens KB Mirrors 1 µm 0.1 µm

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging X-ray Optics - focusing – Beryllium lens focusing optic ~ 10µm FWHM focal spot size Positioning resolution and repeatability to 1 µm – Beryllium lens focusing optic ~ 10µm FWHM focal spot size Positioning resolution and repeatability to 1 µm

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Be lens calculation for 10 micron focus Focal spot size including diffraction and roughness FWHM in microns: Horiz: 12.0 Vert: 10.1

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging X-ray Optics – pulse picker – Pulse picker Permit LCLS operation at 120 hz Single pulses. Useful for samples supported on substrates Reduced rate ex. 10 hz operation High damage threshold Use rotating discs, concept already in use at ESRF – Pulse picker Permit LCLS operation at 120 hz Single pulses. Useful for samples supported on substrates Reduced rate ex. 10 hz operation High damage threshold Use rotating discs, concept already in use at ESRF

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging X-ray Optics - compressor Henry Chapman LLNL λ (nm) d (nm) θφbSin βH * (mm) Δλ w /λ (%) º-90º % 476 µm

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Sample environment - Vacuum requirements Assumptions: ‘unshielded’ beam path of 10 cm for 1 µm 2 beam bio-molecule ~ 500kDa ~ 5 x 10 4 atoms Background scatter 1% 500 atoms in path Atoms in background gas same z as in the molecule p ≤ 1 x10 -7 torr Assumptions: ‘unshielded’ beam path of 10 cm for 1 µm 2 beam bio-molecule ~ 500kDa ~ 5 x 10 4 atoms Background scatter 1% 500 atoms in path Atoms in background gas same z as in the molecule p ≤ 1 x10 -7 torr

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Sample environment (1.3.3) Sample chamber (vacuum better than torr) Detector positioning mm from sample Sample diagnostics - ion and electron ToF Cryo-EM stage Sample environment (1.3.3) Sample chamber (vacuum better than torr) Detector positioning mm from sample Sample diagnostics - ion and electron ToF Cryo-EM stage Sample environment – detector position

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging The number and solid angle of the detector elements are dependent on particle size and resolution N  x xx D = N  x / s f max ff Real space samples:  x Smallest period sampled: 2  x = d or f max = 1/d Oversampling (per dimension): s Array size: N = D s /  x = 2 D s / d E.g. D = 57 nm, d = 0.3 nm, s = 2  N = 760 = 0.15 nm  pix = 1.3 mrad Henry Chapman LLNL

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Detector size fixes resolution E.g., d = 0.3 nm, s = 2, = 0.15 nm, N = 760  D ≈57 nm 2 = 30º z d = 1450 mm, 760 pixels D = 1000 nm, d=5.2 nm z d = 83.6 mm, 760 pixels D = 57 nm zdzd 110  m pixels

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Sample environment (1.3.3) Sample chamber (vacuum better than torr) Detector positioning mm from sample Sample diagnostics - ion and electron ToF Cryo-EM stage Sample environment (1.3.3) Sample chamber (vacuum better than torr) Detector positioning mm from sample Sample diagnostics - ion and electron ToF Cryo-EM stage Sample environment

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Sample environment - Sample diagnostics 3 x10 12 photons in 100 nm spot (a) 2 fs pulse (b) 10 fs pulse (c) 50 fs pulse Provide diagnostics to understand the ‘explosion’ Electron and Ion ToF detectors able to resolve single atom fragments (1 AMU) 1/1000 in electron energy 3 x10 12 photons in 100 nm spot (a) 2 fs pulse (b) 10 fs pulse (c) 50 fs pulse Provide diagnostics to understand the ‘explosion’ Electron and Ion ToF detectors able to resolve single atom fragments (1 AMU) 1/1000 in electron energy

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging System Specifications ItemPurposeSpecification Focusing optics Produce required flux.Focal spot sizes of 10,1, 0.1 micron Sample chamber Vacuum sample env., reduced background Vacuum below torr DetectorMeasurement of diffraction pattern 2-D, 760 x 760 pixels, 110  110 µm pixel size, with central hole (shared LCLS det.) Sample diagnostic Ion TOF analysis of sample fragments Resolution of one mass unit up to 100 AMU Sample diagnostic Electron TOF analysis of sample fragments Resolution of Optical Compressor Reduce pulse length20 fs pulse length

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Sample environment (1.3.3) Sample chamber (vacuum better than torr) Detector positioning mm from sample Sample diagnostics - ion and electron ToF Cryo-EM stage Sample environment (1.3.3) Sample chamber (vacuum better than torr) Detector positioning mm from sample Sample diagnostics - ion and electron ToF Cryo-EM stage Sample environment – cryo-EM stage

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Sample environment - Cryo-EM stage Cryo-EM Goniometer All motion drives outside vacuum In use on SR sources for STXM Provides full angular- spatial degrees of freedom to collect 3D data Cryo-EM Goniometer All motion drives outside vacuum In use on SR sources for STXM Provides full angular- spatial degrees of freedom to collect 3D data

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging Summary Instrument concept advancing well Near term issues: detector hole, single versus multiple optics Sample chamber: design should accommodate Raster system (samples on substrate) Particle injector Cryo-EM stage Data acquisition-storage-analysis are challenging Diagnostics-wavefront in particular are challenging Instrument concept advancing well Near term issues: detector hole, single versus multiple optics Sample chamber: design should accommodate Raster system (samples on substrate) Particle injector Cryo-EM stage Data acquisition-storage-analysis are challenging Diagnostics-wavefront in particular are challenging

J. B. Hastings LCLS FAC April 17, 2007 Coherent X-Ray Imaging