Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.

Slides:



Advertisements
Similar presentations
Experimental Particle Physics
Advertisements

General Characteristics of Gas Detectors
Radiation Detection ionization chambers (dosimeters, pulse chambers, particle track chambers) scintillation detectors semiconductor detectors photographic.
Glass Resistive plate chambers for muon Detection
Geiger Counters. Higher Voltage As the voltage increases in a gas detector the ions collected increases. The proportional region ends. –Streamer mode.
ATLAS Tile Calorimeter Performance Henric Wilkens (CERN), on behalf of the ATLAS collaboration.
HEP Experiments Detectors and their Technologies Sascha Marc Schmeling CERN.
Dispersive property of a G-M tube HV - + In the proportional region a G-M tube has dispersive properties tube voltage.
Drift velocity Adding polyatomic molecules (e.g. CH4 or CO2) to noble gases reduces electron instantaneous velocity; this cools electrons to a region where.
Detection of Gamma-Rays and Energetic Particles
Bulk Micromegas Our Micromegas detectors are fabricated using the Bulk technology The fabrication consists in the lamination of a steel woven mesh and.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
February 2002, D0 meetingAuguste Besson1 Argon purity measurement of the calorimeter Argon Test Cell (A.T.C.) –measures the equivalent O 2 pollution with.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
Proportional Counters
Lesson 17 Detectors. Introduction When radiation interacts with matter, result is the production of energetic electrons. (Neutrons lead to secondary processes.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Detectors. Measuring Ions  A beam of charged particles will ionize gas. Particle energy E Chamber area A  An applied field will cause ions and electrons.
28 June 2002Santa Cruz LC Retreat M. Breidenbach1 SD – Silicon Detector EM Calorimetry.
Techniques for detecting X-rays and gamma-rays Pair production Creation of elementary particle and its antiparticle from a photon. Occurs only if enough.
ZEUS Calorimeter (1) At HERA high energetic electrons (e) collide with high energetic protons (P). The ZEUS detector measures the properties of the particles.
TRAINING COURSE ON RADIATION DOSIMETRY: Instrumentation 1 – Gas detectors / Part 1 Anthony WAKER, University of Ontario Instutute of Technology Wed. 21/11/2012,
4/2003 Rev 2 II.3.1 – slide 1 of 30 Part IIQuantities and Measurements Module 3Principles of Radiation Detection and Measurement Session 1Ionization Chambers.
Properties of X-Rays Reference: “Elements of X-ray Diffraction”, 3nd Edition, B.D. Cullity, and S.R. Stock, Prentice Hall, NJ Chapter 1
Chapter 24 Capacitance, Dielectrics, Electric Energy Storage
Andy White U.Texas at Arlington (for J.Yu, C.Han, J.Li, D.Jenkins, J.Smith, K.Parmer, A.Nozawa, V.Kaushik) 10/18/04 IEEE/NSS Digital Hadron Calorimetry.
Recirculation Concept - Cyclotron Radio frequency alternating voltage Hollow metal drift tubes time t =0 time t =½ RF period D-shaped.
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
Calor 2002, march 2002Auguste Besson1 Argon purity measurement of the D0 calorimeter Auguste Besson (ISN - Grenoble) for the D0 collaboration 10.
Performance test of STS demonstrators Anton Lymanets 15 th CBM collaboration meeting, April 12 th, 2010.
Jackson Choate.  High-energy electrons and photons lose energy primarily through Bremsstrahlung and pair production, respectively.  Bremsstrahlung.
Tools for Nuclear & Particle Physics Experimental Background.
Spring, 2009Phys 521A1 Charged particle tracking.
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
How do we detect photons? Kensuke Okada RIKEN BNL Research Center April 20,
Chevron / Zigzag Pad Designs for Gas Trackers
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Montpellier, November 15, 2003 J. Cvach, TileHCAL and APD readout1 TileHCAL- fibre readout by APD APDs and preamplifiers Energy scan with DESY beam –Energy.
Ionization Detectors Basic operation
Seeing the Subatomic Stephen Miller Saturday Morning Physics October 11, 2003.
Using delay lines on a test station for the Muon Chambers Design considerations (A. F. Barbosa, Jul/2003)
Electrons capture in the air instrumentation examples1 The subject: Medical Ionization Chambers are air filled ICs In the air, electrons are captured by.
Particle Detectors for Colliders Robert S. Orr University of Toronto.
Simulations of various aspects of the PPS Various members of the collaboration, to be enumerated later.
R.S. Orr 2009 TRIUMF Summer Institute
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
A Prototype Diamond Detector for the Compton Polarimeter in Jefferson lab, Hall C Medium Energy Physics Group Amrendra.
Chapter V Radiation Detectors.
MuTr Chamber properties K.Shoji Kyoto Univ.. Measurement of MuTr raw signal Use oscilloscope & LabView Read 1 strip HV 1850V Gas mixture Ar:CO 2 :CF 4.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
Geiger-Mueller Counters Darwin L. Boyd Kent State University School of Technology.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
PPAC Jonathan Olson University of Iowa Thesis Defense 8 April 2005.
Thorsten Lux. Charged particles X-ray (UV) Photons Cathode Anode Amplification Provides: xy position Energy (z position) e- CsI coating 2 Gas (Mixture)
Gruppo di Napoli A. Aleksandrov, G. De Lellis, A. Di Crescenzo, M. Fioranelli, A. Iacomino, A. Lauria, J. Lotti, M.C. Montesi, V. Tioukov 1. Detector structure.
Topic 6 : Atomic and Nuclear Physics.
Activities on straw tube simulation
Dr: Mohamed Afifi By Lecturer Radiological Science
Panagiotis Kokkas Univ. of Ioannina
Detection of muons at 150 GeV/c with a CMS Preshower Prototype
PAN-2013: Radiation detectors
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
Ionization detectors ∆
Experimental Particle Physics
Pre-installation Tests of the LHCb Muon Chambers
Experimental Particle Physics
Engineering Design Review
The MPPC Study for the GLD Calorimeter Readout
Why silicon detectors? Main characteristics of silicon detectors:
Presentation transcript:

Ionization

Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons to separate and move to charged plates. –Applied voltage V –Measured current I I V   A E

Saturation Ion – electron pairs created will recombine to form neutral atoms. –High field needed to collect all pairs –V > V 0 Uniform particle beam creates constant current. –Saturation current I 0 I0I0 V0V0 I V Ion recombination Saturation

Saturation Current A uniform beam is defined by fluence rate and energy. –Intensity is the product The number of ions depends on the gas. –Ionization energy W The saturation current is proportional to intensity Energy per area per time: The number of ion pairs N is: The saturation current is:

Ionization Energy W values measure the average energy expended per ion pair. –Electrons uniform with energy –Protons above 10 keV similar to electrons W for heavy ions increases at low energy. –Excitation instead of ionization GasW  W  (eV/ion pair) He4342 H O CO CH C 2 H Air3634

Electrometer Typical Problem A good electrometer can measure a current of A. What is the corresponding rate of energy absorption in a parallel-plate ionization chamber with W = 30 eV/ip? Answer The energy rate is related to the intensity. –( C/s)(30 eV)/(1.6 x C) = 1.88 x 10 4 eV/s –Equivalent to one 18.8 keV particle per second

Smoke Detector Many household smoke detectors are ionization chambers. –Electric field from a battery – 241 Am alpha source (.5 mg) Smoke interrupts saturation current through recombination. howthingswork.com

Liquid Argon Liquid noble gases can be used in ionization chambers. –Liquid argon, krypton, xenon An applied field of 1.1 MV/m used to suppress scintillation in liquid Ar. Focus on an example from the Dzero electromagnetic calorimeter. Liquid argon parameters –Density 1.41 g/cm 3 –Boiling point 87 K –W value 23.6 ev/ion pair

Uranium Cell Uranium plates are alternated with readout pads. –Separated by liquid argon Readout pads are 5-layer printed circuit boards. –Outer readout pads –Inner layer readout wires –Ground planes to reduce crosstalk –Resistive coat at 2.5 kV 4.0 mm 2.3 mm 4.3 mm depleted uranium liquid Ar gaps readout pad

Shower Production Uranium acts as an absorber. –Density g/cm3 –Interaction primarily in uranium –4 cm for electromagnetic Shower particles ionize liquid argon in the gaps. –Measured on circuit board pads depleted uranium incident particle

Sampling Calorimeter The energy loss in the uranium is much greater than in the argon. Ionization is a sample of the particles in the shower. –Readout signal is proportional to a sample of the shower energy. A sampling calorimeter loses some resolution due to statistics. –Gains in flexibility to construct optimal layer thicknesses

High Voltage Response

Pulse Mode Ionization signals are read out as individual pulses. –Cell is a capacitor C D –Total charge dQ proportional to ionization Charge sensitive preamp integrates current pulse to get charge. –Measure as voltage change   i in v out CDCD CFCF

Pedestal Integrating the charge means selecting a sample time and initial voltage. –2.4  s –Subtract the baseline voltage The distribution with no input signal is the pedestal. –Asymmetric due to uranium noise

Cell Noise The pedestal is not constant. –Variation of the pedestal contributes to statistical error. –Depends on cell capacitance –High voltage on picks up uranium noise

Resolution Total energy for a particle is due to a sum of N channels. Resolution varies with total energy Signal variance S 2 depends on a number of sources of error. –Statistical channel error  –Channel crosstalk error c

Electromagnetic Calibration Electrons of known energy are used to calibrate the cells. –Initial digital counts A j –Cell calibration  j –Tower calibration  –Offset for other material  Compare beam momentum to measured energy for various energies.

Beam Response

Measured Resolution Energy resolution is measured as a fraction  /E. –From mean and standard deviation fit to Gaussian Resolution is fit to a quadratic as a function of momentum –Channel-to-channel variation C –Statistical sampling S –Energy-independent noise N Fit results: –C = ± –S = ± –N = 0.29 ± 0.03 Quoted resolution: