Paul Sellin, Radiation Imaging Group Digital pulse shape discrimination applied to capture-gated neutron detectors P.J. Sellin, S. Jastaniah, W. Catford.

Slides:



Advertisements
Similar presentations
NUCP 2371 Radiation Measurements II
Advertisements

Exploiting VERITAS Timing Information J. Holder a for the VERITAS Collaboration b a) School of Physics and Astronomy, University of Leeds, UK b) For full.
Dante Nakazawa with Prof. Juan Collar
Neutron detectors and spectrometers 1) Complicated reactions → strong dependency of efficiency on energy 2) Small efficiency → necessity of large volumes.
DESCANT and  -delayed neutron measurements at TRIUMF Paul Garrett University of Guelph.
Radiation Detectors / Particle Detectors
Measurement of lifetime for muons captured inside nuclei Advisors: Tsung-Lung Li Wen-Chen Chang Student: Shiuan-Hal Shiu 2007/06/27.
Pete Jones University of Jyväskylä INTAG Workshop GSI, Germany May 2007 Status of digital electronics at JYFL Pete Jones Department of Physics University.
Robert Johnson Faculty: Dr. Calvin Howell Grad Student: David Ticehurst Development of a Neutron Detector with Kinetic Energy Measurement Capability.
Neutron background measurements at LNGS Gian Luca Raselli INFN - Pavia JRA1 meeting, Paris 14 Feb
Paul Sellin, Radiation Imaging Group Charge Drift in partially-depleted epitaxial GaAs detectors P.J. Sellin, H. El-Abbassi, S. Rath Department of Physics.
DESCANT – DEuterated SCintillator Array for Neutron TaggingScott Williams, Warsaw, Oct 2007 DESCANT: DEuterated SCintillator Array for Neutron Tagging.
GAMMA RAY SPECTROSCOPY
S. Zuberi, University of Rochester Digital Signal Processing of Scintillator Pulses Saba Zuberi, Wojtek Skulski, Frank Wolfs University of Rochester.
W. Udo Schröder, 2009 Principles Meas 1 Principles of Measurement.
1 Scintillators  One of the most widely used particle detection techniques Ionization -> Excitation -> Photons -> Electronic conversion -> Amplification.
Coincidence analysis in ANTARES: Potassium-40 and muons  Brief overview of ANTARES experiment  Potassium-40 calibration technique  Adjacent floor coincidences.
Study of plastic scintillator quenching factors Lea Reichhart, IOP Glasgow, April /17.
Status of DRIFT II Ed Daw representing the DRIFT collaboration: Univ. of Sheffield, Univ. of Edinburgh, Occidental College, Univ. of New Mexico Overview.
KamLAND Experiment Kamioka Liquid scintillator Anti-Neutrino Detector - Largest low-energy anti-neutrino detector built so far - Located at the site of.
A scintillation detector for neutrons below 1 MeV with gamma-ray rejection Scintillators are 3 mm BC408, 10 layers total Adjacent layers are optically.

Nuclear Forensics: Neutron Activation & Radiography
Paul Sellin, Radiation Imaging Group Charge Drift in partially-depleted epitaxial GaAs detectors P.J. Sellin, H. El-Abbassi, S. Rath Department of Physics.
Paul Sellin, Radiation Imaging Group Digital techniques for neutron detection and pulse shape discrimination in liquid scintillators P.J. Sellin, S. Jastaniah,
Paul Sellin, Radiation Imaging Group Time-Resolved Ion Beam Induced Charge Imaging at the Surrey Microbeam P.J. Sellin 1, A. Simon 2, A. Lohstroh 1, D.
M2 NPAC – Laboratory CEA Saclay Stefano PANEBIANCO – Neutron-gamma discrimination.
A Front End and Readout System for PET Overview: –Requirements –Block Diagram –Details William W. Moses Lawrence Berkeley National Laboratory Department.
Neutron Monitoring Detector in KIMS Jungwon Kwak Seoul National University 2003 October 25 th KPS meeting.
Electronics and data acquisition system of the extensive air shower detector array at the University of Puebla R. Conde 1, O. Martinez 1, T. Murrieta 1,
Digital analysis of scintillator pulses generated by high-energy neutrons. Jan Novák, Mitja Majerle, Pavel Bém, Z. Matěj 1, František Cvachovec 2, 1 Faculty.
Measurements of the (n,xn) reactions cross sections using new digital methods. Habib Karam Group GRACE.
Measurement of lifetime for muons captured inside nuclei
MEASUREMENT Of γ-RAY ENERGY SPECTRA BY A SCINTILLATION COUNTER
W.Skulski APS April/2003 Eight-Channel Digital Pulse Processor And Universal Trigger Module. Wojtek Skulski, Frank Wolfs University of Rochester.
1 IDM2004 Edinburgh, 9 september 2004 Helenia Menghetti Bologna University and INFN Study of the muon-induced neutron background with the LVD detector.
Neutron detector developments at LPC Caen  -delayed neutron detectors  current limitations  future issues Search for new solid scintillators (Neutromania)
Experimental Nuclear Physics Some Recent Activities 1.Development of a detector for low-energy neutrons a. Hardware -- A Novel Design Idea b. Measure the.
Muon and Neutron Backgrounds at Yangyang underground lab Muju Workshop Kwak, Jungwon Seoul National University 1.External Backgrounds 2.Muon.
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
WIMP search Result from KIMS experiments Kim Seung Cheon (DMRC,SNU)
Electron tracking Compton camera NASA/WMAP Science Team  -PIC We report on an improvement on data acquisition for a Time Projection Chamber (TPC) based.
Timing in Thick Silicon Detectors Andrej Studen, University of Michigan, CIMA collaboration.
1 Two-phase Ar avalanche detectors based on GEMs A. Bondar, A. Buzulutskov, A. Grebenuk, D. Pavlyuchenko, Y. Tikhonov Budker Institute of Nuclear Physics,
Ciemat Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas Daniel Cano-Ott, DAQ meeting in Huelva, July 18 th and 19 th A new flash.
Calibration of uniformity between LYSO crystals Zhigang Wang Institute of High Energy Physics, CAS The Third International Workshop on the High.
1 LTR 2004 Sudbury, December 2004 Helenia Menghetti, Marco Selvi Bologna University and INFN Large Volume Detector The Large Volume Detector (LVD)
1 A two-phase Ar avalanche detector with CsI photocathode: first results A. Bondar, A. Buzulutskov, A. Grebenuk, D. Pavlyuchenko, R. Snopkov, Y. Tikhonov.
Quesly Daniel, Jr. Florida A&M University Dr. Calvin Howell Duke University, TUNL David Ticehurst UNC-Chapel Hill, TUNL Software for Neutron Detector Capture.
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
Multi-Purpose Fast Neutron Spectrum Analyzer with Real-Time Signal Processing Yu.S. Sulyaev 1, E.A. Puryga 1,2, A.D. Khilchenko 1,2, A.N. Kvashnin 1, S.V.
NEM433 Radiation Detection and Measurement Laboratory Fall 2013 Osman Şahin ÇELİKTEN.
 13 Readout Electronics A First Look 28-Jan-2004.
Digital Acquisition: State of the Art and future prospects
DAQ ACQUISITION FOR THE dE/dX DETECTOR
Fast neutron flux measurement in CJPL
Gamma Ray Spectrometry System Design for ITER Plasma Diagnostics
Development of a Pulse Shape Discrimination IC
MoNA detector physics How to detect neutrons. Thomas Baumann NSCL.
Project Structure Advanced Neutron Spectrometer on the International Space Station (ANS-ISS) Mark Christl NASA/MSFC Oct 23, 2015 Honolulu, HI 1 1.
Muon and Neutron detector of KIMS experiment
Irina Bavykina, MPI f. Physik
A First Look J. Pilcher 12-Mar-2004
Neutron Detection with MoNA LISA
Gamma-Gamma Correlations in Na-22
Presented at 2016 IEEE Nuclear Science Symposium - N28-32
Status of Neutron flux Analysis in KIMS experiment
Segmented high resolution fast neutron spectrometer:
Southern Illinois University Edwardsville
The Development of a Segmented Detector using ZnS:Ag/6Li
Presentation transcript:

Paul Sellin, Radiation Imaging Group Digital pulse shape discrimination applied to capture-gated neutron detectors P.J. Sellin, S. Jastaniah, W. Catford Department of Physics University of Surrey Guildford, UK

Paul Sellin, Radiation Imaging Group Contents An overview of the neutron detector work carried out recently at the University of Surrey:  Background to the project:  Pulse shape discrimination (PSD) in liquid scintillators  Digital PSD algorithms  10 B -loaded scintillator for capture-gated fast neutron detection  Results from the digital system:  Digital PSD from integrated and current pulses  PSD Figure of Merit (FOM)  capture-gated neutron detection  Conclusions  References: this presentation covers data recently published: SD Jastaniah and PJ Sellin, “Digital pulse-shape algorithms for scintillation-based neutron detectors”, IEEE Trans Nucl Sci 49/4 (2002) SD Jastaniah and PJ Sellin, “Digital techniques for n/  pulse shape discrimination and capture-gated neutron spectroscopy using liquid scintillators”, submitted to NIM A.

Paul Sellin, Radiation Imaging Group Introduction  Emphasis on fast computationally-simple digital algorithms suitable for field instruments  Efficient n/  discrimination is essential - the extraction of a weak fast neutron flux against a strong gamma ray background  Full-energy fast neutron spectrometry has particular advantages for dosimetry detectors: Motivation for this work:  Development of digital neutron monitors for neutron field measurements, homeland security, and neutron dosimetry  Portable instruments can take advantage of compact digital pulse processing technology See also: A. Rasolonjatovo et al, NIM A

Paul Sellin, Radiation Imaging Group Pulse shape discrimination  Pulse shape discrimination (PSD) in organic scintillators has been known for many years - particularly liquid scintillators (NE213 / BC501A)  PSD is due to long-lived decay of scintillator light caused by high de / dx particles - neutron scatter interactions events causing proton recoils: mean decay time 

Paul Sellin, Radiation Imaging Group Integrated vs current pulses Extraction of scintillation decay lifetime t depends on the RC time constant of the external circuit: Large time constant RC>>  : integrated pulse - event energy extracted from pulse amplitude  extracted from pulse risetime: Short time constant RC<<  : current pulse - event energy extracted from pulse integral  extracted from pulse decay time:

Paul Sellin, Radiation Imaging Group Pulse risetime algorithms Integrated pulses - using a PMT preamplifier Improved signal-noise ratio Risetime limited by preamp (~10ns)  10-90% risetime algorithm Current pulses - anode connected directly to 50  Simple circuitry, fastest response PSD algorithm affected by signal noise  ‘time over threshold’ algorithm Other techniques use a full least-squares fit to the pulse shape, eg. N.V. Kornilov et al, NIM A

Paul Sellin, Radiation Imaging Group 10 B loaded liquid scintillator We have investigated liquid scintillator enriched with 10 B - BC523A Often used for thermal neutron detection, 10B-loaded scintillator can also be used for ‘capture-gated’ neutron spectroscopy: Characteristic double-pulse sequence of moderation + capture provides clean fast neutron signature. Capture pulse has fixed amplitude (10B+n Q value) Amplitude of moderation pulse gives incident neutron kinetic energy  true ‘full energy’ neutron spectrometer

Paul Sellin, Radiation Imaging Group Waveform Digitiser Single channel specification: 8 bit resolution 1 GS/s, 500 MHz 2 Mpoints waveform memory 80 MB/s sustained data transfer rate to PC (12 bit cards, up to 400 MS/s also available) Custom LabView software for real-time pulse analysis and histogramming High speed waveform digitisers now provide 1ns sampling times (1 GS/s), 8 bit resolution, high speed data transfer to PC: We use the Cougar system from Acqiris channel compactPCI crate-based system, expandable up to 80 channels

Paul Sellin, Radiation Imaging Group Detector Cells Various liquid scintillator cells were made (100 ml and 700 ml), containing BC501A and BC523A When filling the cells, the scintillator was bubbled with N 2 gas to purge the oxygen. A two-detector cell was made, with a BGO embedded in the BC523A to detect coincident 478 keV gamma rays from 10 B reaction

Paul Sellin, Radiation Imaging Group Energy Calibration Liquid scintillator operated at 2 gain settings, with separate energy calibrations: High Gain:  photopeak for X/  -rays < 60 keV: Ba, Tb K X-rays 241Am  -ray Low Gain:  Compton edge for high energy  -rays: 57 Co 137 Cs 60 Co 44 keV Tb X-ray 8-bit digital DAQ 44 keV Tb X-ray 12-bit analogue DAQ

Paul Sellin, Radiation Imaging Group PSD at low gain Risetime versus pulse height plot at low gain setting showing n/  PSD from (a) BC501A, and (b) from BC523A.

Paul Sellin, Radiation Imaging Group No PSD in plastic BC454 We also tested PSD in plastic scintillator BC454 - no discrimination was seen for neutron scatter events all events

Paul Sellin, Radiation Imaging Group PSD at high gain At high gain, the 10 B capture peak is visible due to simultaneous detection of 7 Li and  no significant PSD is observed Lack of PSD is due to quenching of slow component from heavy ions - alpha particle PSD has been seen in ‘special’ 10 B-loaded scintillator S. Normand et al, NIM A

Paul Sellin, Radiation Imaging Group PSD Figure of Merit Quality of PSD is described using a Figure of Merit (FOM): Vertical ‘slices’ from the 2D spectra give risetime histograms: low energy FOM = 1.4 high energy FOM = 1.5 Method is similar to conventional analogue PSD techniques FOM is extracted digitally in software FOM>1 required for ‘good’ PSD n  S n  = separation of two peaks F n,  = n,  peak centroid position

Paul Sellin, Radiation Imaging Group PSD from current pulses Current pulses use ‘time over threshold’ in place of risetime - the 2D plot has a different shape FOM is slightly worse than for integrated pulses ( ) with poorer valley separation

Paul Sellin, Radiation Imaging Group Capture-gated neutron detection Capture-gated neutron detection gives very clean fast neutron signature Trigger event rate is low, requiring full moderation of neutron within the scintillator  volume dependant PSD can be used to further reject false TAC start pulses

Paul Sellin, Radiation Imaging Group Fast neutron capture lifetime Fast neutron capture lifetime  has an exponential distribution: where  depends only on 10B concentration, since   1/v: Scintillator 10 B (%)  (  s) BC523A~ BC523~ BC454~ Short neutron capture times allow high event rates for the capture- gated detection mode Event rate with our 10GBq AmBe neutron source: ~20Hz for 700ml BC523A cell

Paul Sellin, Radiation Imaging Group Conclusions  High speed waveform digitisers are opening up new techniques for neutron and gamma ray detection in fast organic scintillators  The performance of 1 ns sampling time, 8-bit resolution, digitisers has been successfully demonstrated  Good n/  PSD has been demonstrated using computationally- simple digital pulse risetime algorithms  The application of digital techniques to capture-gated fast neutron detection is a powerful technique for fast neutron monitors Issues for the future:  Multi-channel 1 GS/s digitisers are still expensive  Digitisers are not yet available in a ‘laptop’ format  True neutron spectroscopy from capture-gated 10 B-loaded scintillator is currently limited by the non-linear light output of these materials  New loaded scintillators need to be developed offering good PSD of the neutron capture reaction (eg. 7 Li+  from 10 B).