1 結構防振液流阻尼器之研發及應用研討會 (95.2.11) 實驗案例 Shaking Table Test of Full Scale Structure Controlled with Fluid Dampers (EASEC-9, Bali, Indonesia, 2003.12.16-18,

Slides:



Advertisements
Similar presentations
Structural Dynamics Laboratory Department of Engineering Science, University of Oxford First European Conference on Earthquake Engineering and Seismology,
Advertisements

Design of Steel and Composite-Structures for Seismic Loading – Safety Requirements, Concepts and Methods – Prof. Dr.-Ing. Ekkehard Fehling, University.
1 LESSLOSS Sub Project 7 Techniques and Methods for Vulnerability Reduction Barcelona 18 th May 07 – Lisbon 24 th May 07 LESSLOSS Dissemination Meeting.
Y.P. Wang 1, W.H. Liao 2 and C.L. Lee 2 1 Professor of Civil Engineering 2 Research Assistant Professor of NHMRC National Chiao-Tung University Y.P. Wang.
Optimal placement of MR dampers
Mechanics Based Modeling of the Dynamic Response of Wood Frame Building By Ricardo Foschi, Frank Lam,Helmut Prion, Carlos Ventura Henry He and Felix Yao.
An-Najah National University
MR 유체 감쇠기를 이용한 사장교의 지진응답 제어 기법
Project #4 Energy Dissipation Capacity of a Wood-frame Shear Wall CEE Numerical Analysis.
Impacts of Seismic Stress on Pore Water Pressure in Clayey Soil By: Qazi Umar Farooq Lecturer Civil Engineering Dept Univ of Engg & Tech Taxila.
Application of Fluid-Structure Interaction Algorithms to Seismic Analysis of Liquid Storage Tanks Zuhal OZDEMIR, Mhamed SOULI Université des Sciences et.
Task Innovative Systems Fluid Dampers for Seismic Energy Dissipation of Woodframe Structures Michael D. Symans Kenneth J. Fridley William F. Cofer.
 Key Learning ◦ Various shaped objects offer different strengths.  Unit Essential Question ◦ Why is it important to know the strengths of various shaped.
Utilizing Steel Plate Shear Walls for Seismic Hazard Mitigation
TEST REQUIREMENTS AND IT EXECUTION FOR THE VELOCITY DEPENDENT ENERGY DISSIPATION DEVICES Deh-Shiu Hsu, Yung-Feng Lee, Chien-Yuan Hou and Juan-The Lee Department.
An-Najah National University Faculty of Engineering Civil Engineering Department Terra Santa School Structural Design and Analysis Prepared By: Bara Shawahna.
Villanova University Dept. of Civil & Environmental Engineering CEE 8414 – Structural Dynamics Northridge Earthquake 1 Northridge Earthquake - Concrete.
Quake Summit 2012 July 9-12, 2012, Boston
GW Rodgers, C Denmead, N Leach, JG Chase & John B Mander
Cheng Chen Ph.D., Assistant Professor School of Engineering San Francisco State University Probabilistic Reliability Analysis of Real-Time Hybrid Simulation.
Structural Dynamics & Vibration Control Lab 1 December Department of Civil & Environmental Engineering K orea A dvanced I nstitute of S cience.
Static Pushover Analysis
조상원 * : 박사과정, 한국과학기술원 건설환경공학과 조상원 * : 박사과정, 한국과학기술원 건설환경공학과 정형조 : 교수, 세종대학교 토목환경공학과 정형조 : 교수, 세종대학교 토목환경공학과 박선규 : 교수, 성균관대학교 토목공학과 박선규 : 교수, 성균관대학교 토목공학과.
Close-up view of damage to the Government Hill School located at the head of a landslide.
Structural Analysis and Design of
1 지진하중을 받는 구조물의 MR 댐퍼의 동특성을 고려한 반능동 신경망제어 Heon-Jae Lee 1), Hyung-Jo Jung 2), Ju-Won Oh 3), In-Won Lee 4) 1) Graduate Student, Dept. of Civil and Environmental.
Structural option for the Jinping neutrino central detector Contributor : Yuanqing Wang, Zongyi Wang Speaker : Zongyi Wang Department of civil engineering,
Tsinghua University·Beijing Real-time dynamic hybrid testing coupled finite element and shaking table Jin-Ting Wang, Men-Xia Zhou & Feng Jin.
In-Won Lee, Professor, PE In-Won Lee, Professor, PE Structural Dynamics & Vibration Control Lab. Structural Dynamics & Vibration Control Lab. Korea Advanced.
1 NEESR Project Meeting 22/02/2008 Modeling of Bridge Piers with Shear-Flexural Interaction and Bridge System Response Prof. Jian Zhang Shi-Yu Xu Prof.
NEESR-SG: Controlled Rocking of Steel- Framed Buildings with Replaceable Energy Dissipating Fuses Greg Deierlein, Paul Cordova, Eric Borchers, Xiang Ma,
Structural Dynamics & Vibration Control Lab. 1 Kang-Min Choi, Ph.D. Candidate, KAIST, Korea Jung-Hyun Hong, Graduate Student, KAIST, Korea Ji-Seong Jo,
MASc Thesis Research Workplan Hybrid Steel-Timber Structures Mathieu Angers UBC Picture by B & K Timber Structures.
An-Najah National University Faculty of Engineering Civil Engineering Department Graduation Project Prepared by : 1- Areej Melhem 2- Jawad Ateyani 3-Rasha.
Hyung-Jo Jung Sejong University, Korea Hyung-Jo Jung Sejong University, Korea Kang-Min Choi Korea Advanced Inst. of Science and Tech. Kang-Min Choi Korea.
Computational Structural Engineering Institute Autumn Conference 2002 Oct , 2002 VIBRATION CONTROL OF BRIDGE FOR SERVICEABILITY Jun-Sik Ha 1),
Structural Dynamics & Vibration Control Lab., KAIST 1 Structural Vibration Control Using Semiactive Tuned Mass Damper Han-Rok Ji, Graduate Student, KAIST,
Structural Dynamics & Vibration Control Lab 1 Smart Passive System based on MR Damper for Benchmark Structural Control Problem for a Seismically Excited.
*Man-Cheol Kim, Hyung-Jo Jung and In-Won Lee *Man-Cheol Kim, Hyung-Jo Jung and In-Won Lee Structural Dynamics & Vibration Control Lab. Structural Dynamics.
조상원 * : 박사과정, 한국과학기술원 건설환경공학과 조상원 * : 박사과정, 한국과학기술원 건설환경공학과 정형조 : 교수, 세종대학교 토목환경공학과 정형조 : 교수, 세종대학교 토목환경공학과 이종헌 : 교수, 경일대학교 토목공학과 이종헌 : 교수, 경일대학교 토목공학과.
Strength of Material-1 Introduction. Dr. Attaullah Shah.
Villanova University Dept. of Civil & Environmental Engineering CEE 3704 Statistical and Numerical Analysis 1 Group Project #2 Energy Dissipation Capacity.
Structural Dynamics & Vibration Control Lab., KAIST, Korea 1 A Comparative Study on Aseismic Performances of Base Isolation Systems for Multi-span Continuous.
MODELING OF SEISMIC SLOPE BEHAVIOR WITH SHAKING TABLE TEST Meei-Ling Lin and Kuo-Lung Wang Department of Civil Engineering, National Taiwan University.
 - 합성법을 이용한 사장교의 지진응답 제어 년도 한국전산구조공학회 가을 학술발표회 박규식, 한국과학기술원 건설 및 환경공학과 박사후과정 정형조, 세종대학교 토목환경공학과 조교수 윤우현, 경원대학교 산업환경대학원 부교수 이인원, 한국과학기술원.
Kang-Min Choi, Kang-Min Choi, Graduate Student, KAIST, Korea Hyung-Jo Jung Hyung-Jo Jung, Professor, Sejong National University, Korea In-Won Lee In-Won.
Date of download: 5/31/2016 Copyright © ASME. All rights reserved. From: Theoretical and Experimental Studies for the Application of Shape Memory Alloys.
Sang-Won Cho* : Ph.D. Candidate, KAIST Sang-Won Cho* : Ph.D. Candidate, KAIST Byoung-Wan : Ph.D. Candidate, KAIST Byoung-Wan : Ph.D. Candidate, KAIST Hyung-Jo.
HYBRID SYSTEM CONTROLLED BY A  -SYNTHESIS METHOD International Symposium on Earthquake Engineering Commemorating 10 th Anniversary of the 1995 Kobe Earthquake.
Advanced Science and Technology Letters Vol.32 (Architecture and Civil Engineering 2013), pp Experimental.
INTRODUCTION Due to Industrial revolution metro cities are getting very thickly populated and availability of land goes on decreasing. Due to which multistory.
1. Two rods, one of nylon and one of steel, are rigidly connected as shown in Fig. P.1.2. Determine the stresses and axial deformations when an axial load.
년도 한국지진공학회 춘계학술발표회 Hybrid Control Strategy for Seismic Protection of Benchmark Cable-Stayed Bridges 박규식, 한국과학기술원 토목공학과 박사과정 정형조, 한국과학기술원.
2Master of the Department of Civil Engineering, NTUT, Taipei, Taiwan.
An-Najah National University Faculty of Engineering
Structural aspects related to the vacuum vessel of the SHIP Project
2 Master of the Department of Civil Engineering, NTUT, Taipei, Taiwan.
Deflection: Virtual Work Method; Beams and Frames
GUIDED BY, MS. D. DARLING HELEN LYDIA M.TECH., PRESENTED BY,
An-Najah National University
Dr-Ing Asrat Worku, AAIT
Modal Control for Seismically Excited Structures using MR Damper
Assessment of Base-isolated CAP1400 Nuclear Island Design
Earthquake resistant buildings
An-Najah National University
Supervisor: Dr. Mahmoud Dweikat.
반능동 MR 유체 감쇠기를 이용한 지진하중을 받는 구조물의 신경망제어 이헌재, 한국과학기술원 건설환경공학과 석사과정
Implementation of Modal Control for
Robust Hybrid Control System
a Bang-Bang Type Controller
Presentation transcript:

1 結構防振液流阻尼器之研發及應用研討會 ( ) 實驗案例 Shaking Table Test of Full Scale Structure Controlled with Fluid Dampers (EASEC-9, Bali, Indonesia, , ppVID1-7) Deh-Shiu Hsu, Yung-Feng Lee, Guan-Kai Wang and Chien- Yaun Hou Department of Civil Engineering National Cheng Kung University Tainan, Taiwan, R.O.C

2 Efforts for produce fluid dampers in Taiwan: Performance test for the devices : small scale, full scale Shaking table structural test : model structures, full scale structures

3 Prototype of the damper Fig.1

4 Test installation for cyclic dynamic performance test data acquisition system Pumping system load cell damper actuator Fig.2

5 Benchmark structure installed with fluid dampers —prepared for shaking table test Height : 3.0m in each story Span : 4.5m×3.0m Column : H200×204×12×12 Beam : H200×150×6×9 length of damper : 1.077m linked member : 2.85m steel tube dampers are linked in diagonal direction with pin joints at corner of the 4.5m spans. Fig.3

6 Sketch of the test installation for 3-stories steel frame strain gage load cell LVDT accelerometer Fig.4

7 Physical properties of dampers are detected by cyclic dynamic test. Damper number C1C2C3C4C5C6 C(kN*s/mm) K(kN/mm) Table 1

8 Hysteresis loop of C1 to C6 dampers

9 Earthquake damper various installation installed test cases: 1.PGA 300gal El Centro (May,1940) 2. PGA 800gal JiJi (Sept,1999) 1.C1 2.C2 3.C3 4.C4 5.C5 6.C6 1.Dampers are installed at the lst floor only. 2.Dampers are installed at the l st and 2 nd floors. 3.Dampers are installed at the l st and 3 rd floors. 4.Damper are installed at all of the three floors. Fig.6 totally 48 cases.

10 Earthquake excitations: (a) 1940, EL Centro, 300gal (b) 1999, JiJi EQ, 800gal Fig.7

11 Table 2 Test Results : responses of the benchmark structure (without damper installed) EQPGA(gal)1st floor2nd floor3rd floor floor displacement (mm) EL Centro JiJi floor acceleration (g) EL Centro JiJi column base shear (kN) EL Centro JiJi axial force of S-column (kN) EL Centro JiJi axial force of N-column (kN) EL Centro JiJi

12 Table 3 Test Results : Displacement and its control efficiency when C1 damper is installed floor floor installed with damper EL Centro 300 galJiJi 800 gal displacement (mm) control efficiency (%) displacement (mm) control efficiency (%) 1 1F ,3F ,2F ,2,3F F ,3F ,2F ,2,3F F ,3F ,2F ,2,3F

13 Table 4 Test Results : Acceleration and its control efficiency when C1 damper is installed floor floor installed with damper EL Centro 300 galJiJi 800 gal acceleration (g) control efficiency (%) acceleration (g) control efficiency (%) 1 1F ,3F ,2F ,2,3F F ,3F ,2F ,2,3F F ,3F ,2F ,2,3F

14 Table 5 Test Results : Shear force and max. axial force with its control efficiency of the column at 1st floor when C1 damper is installed floor installed with damper EL Centro 300 galJiJi 800 gal Maximum ( k N) control efficiency (%) Maximum (kN) control efficiency (%) Column shear force 1F ,3F ,2F ,2,3F Axial force in S-column 1F ,3F ,2F ,2,3F Axial force in N-column 1F ,3F ,2F ,2,3F

15 As an example, when C1 damper is installed in all of the floors. Fig.8 damping ratio of the structure is increased by 32%

16 Fig.9 Hysteresis loops of the damper installed at the 1st floor in the case of damper installed in all of three floors and subject to EL Centro earthquake.

17 Fig.10 Hysteresis loops of the damper installed at the 1st floor in the case of damper installed in all of three floors and subject to JiJi earthquake.

18 Numerical analysis: (selected example) Numerical analysis by software package SAP2000N is also performed and then compared to the test data. Fig.11 Comparison of theoretical and experimental results.

19 Conclusions: In order to develop the potential of locally product dampers, research is needed and many of tests have to be taken to fulfill the needs of design requirements and to guarantee the quality of the products. What we have done in Taiwan do have enriching the confidence to introduce the technique to construction and designing engineers.

20 Carefully seismic design is very much needed before the aseismatic engineering measures are executed. Static and dynamic properties of energy dissipation devices should be very well understood. In addition, the location, as well as the number of damper intended to be installed should be analysed and designed in detail before the control system is applied to the real project. Here is an example which negative control result is obtained.

21 Example : Failed control design with improper damper installed system C6 damper is installed at 1,2, and 3 floors and subjected to JiJi earthquake. The Figure shows the negative acceleration control results. Fig.12 Improper design

22 Thanks for attention!