Kirov A S, MSKCC Overview of Geant4 Use and Issues in Imaging: Emission Tomography (PET and SPECT) Assen S. Kirov Department of Medical Physics Memorial.

Slides:



Advertisements
Similar presentations
GATE a simulation platform for nuclear medicine based on GEANT4
Advertisements

Computer Simulation for Emission Tomography: Geant4 and GATE Xiao Han Aug
The GATE-LAB system Sorina Camarasu-Pop, Pierre Gueth, Tristan Glatard, Rafael Silva, David Sarrut VIP Workshop December 2012.
PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
Chapter 8 Planar Scintigaraphy
Fysisk institutt - Rikshospitalet 1. 2 Overview Gamma camera Positron emission technology (PET) Computer tomography (CT) Proton therapy Electrical impedance.
Estimation of the effects of a lead vest on dose reduction for NPP workers using Monte Carlo calculations KIM JEONG-IN.
MONTE-CARLO TECHNIQUES APPLIED TO PROTON DOSIMETRY AND RADIATION SAFETY F. Guillaume, G. Rucka, J. Hérault, N. Iborra, P. Chauvel 1 XXXV European Cyclotron.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Simulation System for Emission Tomography (SimSET): using the new block detector feature. Robert L. Harrison, William C. J. Hunter, Steven B. Gillispie,
Simulation System for Emission Tomography (SimSET): using simulation to research ideas in emission tomography. Robert L. Harrison, Steven B. Gillispie,
Examples of GATE simulation Yun Dong. Different systems available in GATE Scanner: most generic system; Cylindrical PET: cylindrical geometry; CPET: simulate.
Estimating 3D Respiratory Motion from Orbiting Views Rongping Zeng, Jeffrey A. Fessler, James M. Balter The University of Michigan Oct Funding provided.
Transforming Static CT in Gated PET/CT Studies to Multiple Respiratory Phases M Dawood, F Büther, N Lang, X Jiang, KP Schäfers Department of Nuclear Medicine,
tomos = slice, graphein = to write
Monte Carlo model and spectral measurements of a computed tomography x-ray tube Magdalena Bazalova Frank Verhaegen.
PHYSICS IN NUCLEAR MEDICINE: QUANTITAITVE SPECT AND CLINICAL APPLICATIONS Kathy Willowson Department of Nuclear Medicine, Royal North Shore Hospital University.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
The brachytherapy advanced example Susanna Guatelli (CERN/INFN)
Very High Resolution Small Animal PET Don J. Burdette Department of Physics.
DIGITAL HIGH-RESOLUTION HEART PHANTOMS Abstract Background:X-ray based imaging modalities employ ionizing radiation with the potential for causing harmful.
Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation.
Design and simulation of micro-SPECT: A small animal imaging system Freek Beekman and Brendan Vastenhouw Section tomographic reconstruction and instrumentation.
Fundamental Limits of Positron Emission Tomography
Medical Image Analysis Dr. Mohammad Dawood Department of Computer Science University of Münster Germany.
MRI image validation using MRI simulation Emily Koch CIS II April 10, 2001.
Octavian Sima Physics Department Bucharest University
Professor Brian F Hutton Institute of Nuclear Medicine University College London Emission Tomography Principles and Reconstruction.
Pedro Arce Introducción a GEANT4 1 GAMOS tutorial Compton Camera Exercises
Evaluation of absorbed fractions for beta- gamma radionuclides in ellipsoidal volumes of soft tissue through Geant4 Ernesto Amato 1, Domenico Lizio 2 and.
Geant4 in production: status and developments John Apostolakis (CERN) Makoto Asai (SLAC) for the Geant4 collaboration.
Simulation Study of Muon Scattering For Tomography Reconstruction
Nuclear Medicine: Tomographic Imaging – SPECT, SPECT-CT and PET-CT Katrina Cockburn Nuclear Medicine Physicist.
Improvement of the Monte Carlo Simulation Efficiency of a Proton Therapy Treatment Head Based on Proton Tracking Analysis and Geometry Simplifications.
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Profiling study of Geant4-GATE Discussion of suggested VRTs Nicolas Karakatsanis, George Loudos, Arion Chatziioannou Geant4-GATE technical meeting 12 th.
P. Rodrigues, A. Trindade, L.Peralta, J. Varela GEANT4 Medical Applications at LIP GEANT4 Workshop, September – 4 October LIP – Lisbon.
Improved Hybrid PET Imaging Using Variable Focal Length Fan-Slat Collimators Thomas C. Rust and Dan J. Kadrmas, Ph.D. Medical Imaging Research Laboratory.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
INFSO-RI Enabling Grids for E-sciencE Grid based telemedicine application for GATE Monte Carlo dosimetric studies using HOPE (Hospital Platform.
Acquisition time6 min1 min 12 s Collimator height25 mm (Anger)12 mm (HiSens) Detector1 layer, 1 pixel / hole3 layers, 1 pixel / hole3 layers, 4 pixels.
STAR Simulation. Status and plans V. Perevoztchikov Brookhaven National Laboratory,USA.
Flair development for the MC TPS Wioletta Kozłowska CERN / Medical University of Vienna.
GATE application example using SuperComputer 국립암센터 박 세 준 연구원.
Monte Carlo Simulation on Performance of Double–scattering Compton Camera J. H. Park a, H. Seo a, Y. S. Kim a, C. H. Kim a, *, J. H. Lee b, C. S. Lee b,
PET Imaging Positron Emission Tomography
The Optimization of Reconstruction Method Reducing Partial Volume Effect in PET/CT 3D Image Acquisition Department of Nuclear Medicine, Samsung Medical.
MCS overview in radiation therapy
Simulations in Medical Physics Y. TOUFIQUE*, R.CHERKAOUI EL MOURSLI*, M.KACI**, G.AMOROS**, *Université Mohammed V –Agdal, Faculté des Sciences de Rabat,
SIMULATION OF BACKGROUND REDUCTION TECHNIQUES FOR Ge DBD DETECTORS Héctor Gómez Maluenda. University of Zaragoza. GERDA/Majorana MC Meeting.
Positron emission tomography without image reconstruction
Prof. Stefaan Vandenberghe Enrico Clementel
Quantitative Nuclear Medicine Imaging
Very High Energy Electron for Radiotherapy Studies
Introduction of GATE 국립암센터 박 세 준 연구원.
Reconstructions with TOF for in-beam PET
Detailed simulations of a full-body RPC-PET scanner
Summary of the Compton-PET project
Opengate meeting 2017 – Marseille, France
CNRS applications in medical imaging
N. Stoffle University of Houston
Monte Carlo Simulation
MUPAGE: A fast muon generator
The Hadrontherapy Geant4 advanced example
EEE telescope simulation
P. Rodrigues, A. Trindade, L.Peralta, J. Varela
GAMOS tutorial Plug-in’s Exercises
Estimation of the effects of a lead vest on dose reduction for NPP workers using Monte Carlo calculations KIM JEONG-IN.
Presentation transcript:

Kirov A S, MSKCC Overview of Geant4 Use and Issues in Imaging: Emission Tomography (PET and SPECT) Assen S. Kirov Department of Medical Physics Memorial Sloan-Kettering Cancer Center New York

Kirov A S, MSKCC Why simulate imaging systems and scans ? Better understand and model phenomena affecting image quality and accuracy Optimize scan imaging and processing parameters Calculate parameters needed for improved image reconstruction

Kirov A S, MSKCC Basis of this talk Membership in the OpenGATE collaboration ( ) Whose goal is -the creation of an elaborate and flexible Monte Carlo program that allows realistic simulation of the physical processes, detector geometry and all factors affecting emission tomography applications -realistic modeling of patient and small animal anatomy - based on GEANT4

Kirov A S, MSKCC Basis of this talk Product of OpenGATE : GATE (GEANT4 Application for Tomographic Emission) Widely used for – PET – SPECT Potential for CT (why not ?) Potential for Radioimmunotherapy and Nuclide Therapy dosimetry Jan et al, PMB 49 (2004) 4543

Kirov A S, MSKCC Use of GEANT4 prior to GATE for imaging GEANT3 and GEANT4 based codes –example Jan S (Thesis) : GePETos Summary of other codes: –Buvat and Castiglioni (Q J Nuc Med, 46, p 48-61, 2002)

Kirov A S, MSKCC GATE architecture GEANT 4 Core Layer Application Layer User Layer Jan et al, PMB 49 (2004) 4543

Kirov A S, MSKCC User Layer … /gate/block/daughters/name crystal /gate/block/daughters/insert box /gate/crystal/placement/setTranslation mm /gate/crystal/geometry/setXLength 30.0 mm /gate/crystal/geometry/setYLength 4.4 mm /gate/crystal/geometry/setZLength 4.75 mm /gate/crystal/setMaterial BGO … -Verbosity and visualization -Geometry -Digitizer -Physics -Sources -Outputs -Experiment

Kirov A S, MSKCC GATE systems Geometry organization: Hierarchical structures –For realistic signal processing organization –Simplifies geometry input GATE system: {Hierarchically organized geometry + corresponding LMF output} 5 GATE systems SPECT - 1 PET – 3 (2 block based, 1 pixelated) Generic -1 Jan et al, PMB 49 (2004) 4543

Kirov A S, MSKCC GATE time and movements Needed for: - Patient and organ motion - Scanner rotation - Activity distribution changes GEANT4 limitations: - geometry: static during simulation - no source movements Solutions in GATE: - Geometry updated between simulation time steps - The source is confined to a smaller volume moving inside a larger emission volume Santin et al, 2003 Strul et al, 2003 Jan et al, PMB 49 (2004) 4543

Kirov A S, MSKCC GATE physics Sources –Particle type, position (volume), direction (solid angle), energy (spectrum), activity –Modified GEANT4’s RDM – virtual clock defines absolute time used to initialize GEANT4’s internal tracking time –Multiple, voxelized sources –e + emission (Jan 2002): »  + spectra parametrization - faster »annihilation photon noncolinearity GEANT4’s interaction processes and cuts Jan et al, PMB 49 (2004) 4543

Kirov A S, MSKCC GATE digitization - Resolution blurring, spatial blurring, crosstalk - Parallelizable and non-parallelizable dead times - Coincidence processing - Post simulation processing of output files stored before digitization

Kirov A S, MSKCC GATE validation PETat least 5 patient and microPET scanners energy spectra, sensitivity, resolution, scatter faction, count rates, image quality, contrast recovery SPECT at least 5 systems energy spectra, sensitivity, resolution,… Prototypeat least 4 systems energy spectra, sensitivity, resolution… More than 15 references in Jan et al, PMB 49 (2004) 4543 and at

Kirov A S, MSKCC GE Advance/ DLS PET scanner

Kirov A S, MSKCC MC based coincidence count rates for IQ phantom See Schmidtlein et al, SU-EE-A4-03 Mod. Poster at this meeting NECR Scattered Trues Randoms

Kirov A S, MSKCC Other issues CT simulations – GATE could handle the geometry, not tested yet Optical imaging – very promising field for GEANT4 : small animal; 3D dosimetry (see Kirov et al, SU-FF-T-229 at this meeting), etc. Worst GATE/GEANT4 problem for imaging »Very time consuming simulations 35 CPU days on 2 GHz !!

Kirov A S, MSKCC Conclusions GEANT4 with GATE- powerful, flexible, convenient for use and accurate tool for nuclear medicine imaging applications GEANT4 without GATE: worth pursuing only if a new approach can drastically improve performance Efficiency: work needed