Double-Beam AAS Single-Beam I0 Double-Beam Isample

Slides:



Advertisements
Similar presentations
Furnace aa. Today is Guy Fawkes Day L’vov platform furnace Sample is placed on platform Temp of platform rises more slowly than that of walls.
Advertisements

Atomic Absorption & Emission Spectroscopy
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Chem. 133 – 4/13 Lecture. Announcements I Exam 2 Results: Ave = 55% (10% below last year’s) Lab: Should finish Set 2 Period 4 lab today Thursday is make-up.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
AAS and FES (Ch 10, 7th e, WMDS)
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
1 A TOMIC SPECTROMETRIC METHODS PART 9. 2 Interferences : Four classes of interferences: 1-Spectral interferences 2-Chemical interferences 3- Refractory.
Metal Analysis by Flame and Plasma Atomic Spectroscopy Flame A. Atomization 1. Types of Atomization Processes a.) Nebulizers b. Electrothermal atomization.
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
INTRODUCTION TO OPTICAL METHODS
Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy.
Analytical Chemistry –Atomic absorption Spectroscopy
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Molecular Fluorescence Spectroscopy
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
ATOMIC SPECTROMETRY 1. Flames 2. Electrothermal Atomizers 3. Plasmas.
Molecular Luminescence
announcements and reminders
Lecture 2 M.Sc.. AA Spectrometer Components Lamp and FlameDetector Fuel Oxidant Nebulizer Double-Click picture for VIDEO.
Atomic Absorption Spectroscopy (AAS)
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
AES: Figures of Merit Linearity over 4 to 5Linearity over 4 to 5 concentration decades concentration decades Reasons for deviations Reasons for deviations.
Molecular Luminescence Secil Koseoglu 11/13/09. Aequorin: Guiding Star for Scientists.
Atomic Absorption Spectroscopy (AAS)
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY Chap 9 Source Modulation Interferences in Atomic Absorption Interferences in Atomic Absorption Spectral.
Fluorescence. Topics Definition Instrumentation Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-induced Fluorescence.
Atomic Fluorescence Spectroscopy (AFS) See also: Fundamental reviews in Analytical Chemistry e.g. Bings, N. H.; Bogaerts, A.; Broekaert, J. A. C. Anal.
Allowed and Forbidden Transitions Only a fraction of all possible transitions are observed. Allowed transitions -high probability, high intensity, electric.
Allowed and Forbidden Transitions Only a fraction of all possible transitions are observed. Allowed transitions -high probability, high intensity, electric.
Molecular Luminescence
Atomic Absorption Spectroscopy
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Spectroscopy (continued) Last time we discussed what spectroscopy was, and how we could use the interaction of light with atoms and molecules to measure.
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Atomic Absorption Spectroscopy
AAS Atomic Absorption Spectrophotometry. AAS – Widely in clinical laboratories to measure elements such as aluminum, calcium, copper, lead, lithium, magnesium,
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
Chapter 15 Molecular Luminescence Spectrometry Three types of Luminescence methods are: (i) molecular fluorescence (ii) phosphorescence (iii) chemiluminescence.
Fluorescence Spectroscopy
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Chapter 9 Atomic Absorption and Atomic Fluorescence Spectrometry.
Atomic-absorption spectroscopy
Chapter 9 Atomic Absorption and Atomic Fluorescence Spectrometry
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
Plasma A Plasma consists of a collection of free-moving electrons and ions and is very hot. Energy must be continually applied to sustain the plasma.
Atomic Absorption Spectroscopy.  Qualitative test for metals in solution  Can also be used for coloured lights  This emission of light is called an.
Chem. 133 – 4/4 Lecture. Announcements I Strike – If the strike occurs, it will affect classes April 14 th and 18 th (unless ended early) – Lab: would.
Chem. 133 – 4/12 Lecture. Announcements I Strike – No Strike now planned Exam 2: – Average was 77 (range 61 to 93) Last HW Set (Set 3 – see handout) Lab.
Chapter 28 Atomic Spectroscopy.
Chem. 133 – 4/4 Lecture.
Satish Pradhan Dnyanasadhana College, Thane Department of Chemistry T
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY
Flame Emission Spectrometry
Chem. 133 – 3/30 Lecture.
The ratio of excited state to ground state atoms as a function of temperature is determined by the Maxwell-Boltzmann expression. Fig Excited state.
Elemental composition
Atomic Absorption and Atomic Fluorescence Spectrometry
Atomic Absorption Spectroscopy
Пламена Спектроскопија
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Inductively Coupled Plasma
Presentation transcript:

Double-Beam AAS Single-Beam I0 Double-Beam Isample Skoog Principles of Instrumental Analysis What is the problem with just measuring Isample/I0?

Background Sources of Background: scattering or molecular emission Background Correction: With blank sample Ac = At - Ablank Deuterium lamp (arc in deuterium atmosphere; continuum 200-380 nm)  absorption of deuterium lamp represents Abackground  absorption of HCL radiation represents At Advantage over blank sample: observe fluctuations in flame Culver et al, Anal. Chem., 47, 920, 1975.

Background Correction with Zeeman Effect Lines differ by ~0.01 nm Ingle and Crouch, Spectrochemical Analysis

Background Correction with Zeeman Effect Unpolarized light from HCL (A) passes through the rotating polarizer (B) Light is separated into perpendicular and parallel components (C) The light enters the furnace with an applied magnetic field, producing 3 absorption peaks (D) Either analyte or analyte + matrix absorb light (E) A cyclical absorbance pattern results (F) Subtract absorbance during perpendicular half of cycle from absorbance during parallel half of cycle to get the background-corrected value Skoog, Principles of Instrumental Analysis

Background Correction with Zeeman Effect DC on atomizer At Ab AC on atomizer DC on source Ingle and Crouch, Spectrochemical Analysis

AAS: Figures of Merit Linearity over 2 to 3 concentration decades (can be problem for multielement analysis) Probability for line overlap is small  Resolution not as critical as for AES Precision: Typically a few % for graphite furnace 0.3 to 1.0% for flame Accuracy: Largely determined by calibration with standards Applicability: Limited for certain elements for which flame or furnace is not hot enough (e.g. W, Ta, Nb). Flow rates of flame are compatible with HPLC flow rates. Speed: Multielement analysis with multiple HCLs may require lamp exchanges to select desired elements. This is tedious and also costs light because of beam splitters.

Method of Standard Additions In order to quantitate the element of interest in a sample, it is necessary to calibrate with the method of standard additions. The analytical signal for the sample, Sx, is obtained (after measuring the blank signal). A small volume, Vs, of a concentrated standard solution of known concentration, cs, is added to a relatively large volume, Vx of the analytical sample. The analytical signal for the standard addition solution, Sx+s, is obtained. cx = (SxVscs)/[Sx+s(Vx+Vs) – SxVx] if Vs << Vx cx = (SxVscs)/[(Sx+s – Sx)Vx]

Are you getting the concept? The determination of Pb in a brass sample is done with AAS. The 50.0 mL original sample was introduced into the instrument and an absorbance of 0.420 was obtained. To the original solution, 20.0 mL of a 10.0 mg/mL Pb standard was then added. The absorbance of this solution was 0.580. Find the concentration of Pb in the original sample. What assumption(s) has been made in order to use a single standard addition?

AAS: Figures of Merit Detection limits: * Generally lower LOD for very volatile elements * Higher LOD for carbide-forming elements (e.g. Ba, B, Ca, Mo, W, V, Zr) * Concentration in GF up to 1000 times higher than in flame; much lower LOD for GF. * Lower LOD for GF-AAS than ICP-AES unless atomization requires high temperature * Generally similar LOD for flame-AAS and ICP-AES * Improve LOD by adding ethanol or methanol to decrease droplet surface tension during nebulization Chemical * HCl often avoided as acid in GF-AAS because interferences: metal chlorides are more volatile than sulfates or phosphates. * Addition of Cs salt to sample suppresses ionization. * La precipitates phosphate, facilitating Ca analysis. * Proteins may clog burners and are precipitated with trichloroacetic acid.

mA: Concentration giving rise to 1% absorption.

Atomic Fluorescence Spectroscopy (AFS) See also: Fundamental reviews in Analytical Chemistry e.g. Bings, N. H.; Bogaerts, A.; Broekaert, J. A. C. Anal. Chem. 2002, 74, 2691-2712 (“Atomic Spectroscopy”) Late 1800’s - Physicists observe fluorescence from Na, Hg, Cd, and Tl 1956 - Alkemade uses AFS to study chemistry in flames 1964 - AFS recognized as an analytical tool www.andor.com

Fluorescence Radiative transition between electronic states with the same multiplicity. Almost always a progression from the ground vibrational level of the 1st excited electronic state. 10-10 – 10-6 sec. Occurs at a lower energy than excitation. Skoog, Hollar, Nieman, Principles of Instrumental Analysis, Saunders College Publishing, Philadelphia, 1998.

Types of Atomic Fluorescence Resonance (a) Excited State Resonance (b) Stokes/Anti-Stokes Direct Line (c-f) Stokes/Anti-Stokes Stepwise Line (g-l) Sensitized (m) Two-Photon Excitation (n) Omenetto, N. and Windfornder, J. D., Applied Spectroscopy, 26(5), 1972, 555-557.

Instrumentation Sources: HCL, laser (cw or pulsed), ICP, Xe arc lamp stable extremely high radiance at excitation wavelength Atomizer: flame, plasma, furnace high nebulization/atomization efficiency for flame, minimize quenching (Ar<H2<H2O<N2<CO<O2<CO2) Wavelength Selection: monochromator, filters low dispersion monochromator or filter with line source Detector: PMT

ICP-AF Spectrometer Ingle and Crouch, Spectrochemical Analysis

LODs for AFS Ingle and Crouch, Spectrochemical Analysis