Mass spec lecture. What kind of info can mass spec give you? Molecular weight Elemental composition (low MW with high resolution instrument) Structural.

Slides:



Advertisements
Similar presentations
Mass Spectrometry Chem 3500 Mass Spectrometry Y. Zhao Lecture 2 A Glimpse of Mass Spectrometry Began from 1920s: Aston, Dempster, Thompson MS is often.
Advertisements

Chapter 20 Molecular Mass Spectrometry Mass spectrometry is capable of providing information about (1) the elemental composition of samples of matter.
FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
Les détecteurs de masse : une révolution en chromatographie 1ère partie : Introduction à la spectrométrie de masse Pr. Jean-Louis Habib Jiwan UCL – Département.
Ionization II: Chemical Ionization CU- Boulder CHEM 5181 Mass Spectrometry & Chromatography J. Kimmel Fall 2007.
12-1 Molecular Mass Spectroscopy Molecular structure Composition of mixtures Molecular mass spectra Ion Source Mass Spectrometers Applications.
Mass Spectrometry Inlet system Ion Source Mass Analyzer Ion Detector.
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Chem. 133 – 4/23 Lecture.
Chem. 133 – 4/28 Lecture. Announcements Lab Report 2.3 due Today Pass back graded materials (lab reports 2.2, Q5, and AP3.1) Today’s Lecture Mass Spectrometry.
Chapter 20 Molecular Mass Spectrometry. Introduction... Mass spectroscopy is perhaps one of the most widely applicable of all the analytical tools available.
Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform.
Mass Spectrometry. How is MS Done? Basic MS Instrumentation.
Mass Spectrometry in the Biosciences: Introduction to Mass Spectrometry and Its Uses in a Company Like Decode. Sigurður V. Smárason, Ph.D. New Technologies.
LC-MS Based Metabolomics. Analysing the METABOLOME 1.Metabolite Extraction 2.Metabolite detection (with or without separation) 3.Data analysis.
Proteomics The proteome is larger than the genome due to alternative splicing and protein modification. As we have said before we need to know All protein-protein.
Atomic Mass Spectrometry
PROTEIN IDENTIFICATION BY MASS SPECTROMETRY. OBJECTIVES To become familiar with matrix assisted laser desorption ionization-time of flight mass spectrometry.
Atomic Mass Spectrometry
Molecular Mass Spectrometry
LC-MS Lecture 7.
Mass Spectroscopy Quantitative Chemical Analysis Harris, 6th Edition
Mass Spectrometry 101 An Introductory Lecture On Mass Spectrometry Fundamentals Presented to the Sandler Mass Spectrometry Users’ Group University of California.
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
Basics of 2-DE and MALDI-ToF MS
Russell Rouseff FOS 6355 Summer 2005 What is Mass Spectroscopy Analytical Chemistry Technique Used to identify and quantify unknown compounds Can also.
Gas Chromatography And Mass Spectrometry
Proteomics Informatics – Overview of Mass spectrometry (Week 2)
<Instant Notes, D. Kealey & P.J. Haines>
Mass Spectrometry Mass spectrometry (MS) is not true “spectroscopy” because it does not involve the absorption of electromagnetic radiation to form an.
Chapter 9 Mass Spectrometry (MS) -Microbial Functional Genomics 조광평 CBBL.
Molecular mass spectrometry Chapter 20 The study of “molecular ions” M + e -  M e -
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 22 Mass spectrometry Copyright © 2007 by W. H. Freeman.
Mass Spectrometry I Basic Data Processing. Mass spectrometry A mass spectrometer measures molecular masses. The mass unit is called dalton, which is 1/12.
UPDATE! In-Class Wed Oct 6 Latil de Ros, Derek Buns, John.
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
Based on ionization of gas phase molecule followed by analysis of the masses of the ions produced. The Mass Spectrum: Graph of ion intensity versus mass-to-charge.
Chapter 20 # 4, 5, 12, 13, 16. Fig (p.551) Mass spectrum of ethyl benzene Fragment peaks Unit: amu or dalton Fragment peaks.
Chemistry 367L/392N Macromolecular Chemistry Lecture 8.
Ionization energy?. Ionization energy? EI Ionization??
CHM 312 Fall 2008 Special Topics in MS Dr. Ralph Mead.
Overview of Mass Spectrometry
Separates charged atoms or molecules according to their mass-to-charge ratio Mass Spectrometry Frequently.
Mass Spectrometry Quantitative Mass Spectrometry
Metabolomics MS and Data Analysis PCB 5530 Tom Niehaus Fall 2015.
Chem. 133 – 4/26 Lecture. Announcements Return graded quiz and additional problem Lab – Lab report deadlines (2:4 – Thursday) Today’s Lecture – Mass Spectrometry.
2014 생화학 실험 (1) 6주차 실험조교 : 류 지 연 Yonsei Proteome Research Center 산학협동관 421호
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
What is Mass Spectrometry? Mass spectrometry could be considered as an analytical technique that involves the study in the gas phase of ionized molecules.
Introduction to Liquid Phase Mass Spectrometry
Chapter 11 Structure Determination: Mass Spectrometry, Infrared Spectroscopy, and Ultraviolet Spectroscopy.
RANIA MOHAMED EL-SHARKAWY Lecturer of clinical chemistry Medical Research Institute, Alexandria University MEDICAL RESEARCH INSTITUTE– ALEXANDRIA UNIVERSITY.
Yonsei Proteome Research Center Peptide Mass Finger-Printing Part II. MALDI-TOF 2013 생화학 실험 (1) 6 주차 자료 임종선 조교 내선 6625.
An introduction to Mass spectrometry. What is mass spectrometry? Analytical tool measuring molecular weight (MW) of sample Only picomolar concentrations.
Metabolomics Part 2 Mass Spectrometry
Peptide Mass Finger-Printing Part II. MALDI-TOF
CHEM133 Mass Spectrometry: Lecture 1
Mass Spectrometry makes it possible to measure protein/peptide masses (actually mass/charge ratio) with great accuracy Major uses Protein and peptide identification.
Mass Spectrometry 101 (continued) Hackert - CH 370 / 387D
Chem. 133 – 4/13 Lecture.
Mass Spectrometry 101 Hackert - CH 370 / 387D
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
Mass Spectrometry Obaid M. Shaikh.
Mass Spectrometry Courtesy
Metabolomics Part 2 Mass Spectrometry
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
M.Prasad Naidu MSc Medical Biochemistry, Ph.D,.
Presentation transcript:

Mass spec lecture

What kind of info can mass spec give you? Molecular weight Elemental composition (low MW with high resolution instrument) Structural info (hard ionization or CID)

How does it work? Gas-phase ions are separated according to mass/charge ratio and sequentially detected

Parts of a Mass Spec Sample introduction Source (ion formation) ________________________ Mass analyzer (ion sep.)high vac Detector (electron multiplier tube)

Sample Introduction/Sources Volatiles Probe/electron impact (EI),Chemical ionization (CI) GC/EI,CI Involatiles Direct infusion/electrospray (ESI) HPLC/ESI Matrix Assisted Laser Adsorption (MALDI) Elemental mass spec Inductively coupled plasma (ICP)

EI, CI EI (hard ionization) –Gas-phase molecules enter source through heated probe or GC column –70 eV electrons bombard molecules forming M+* ions that fragment in unique reproducible way to form a collection of fragment ions –EI spectra can be matched to library stds CI (soft ionization) –Higher pressure of methane leaked into the source (mtorr) –Reagent ions transfer proton to analyte

CI/ ion-molecule reaction 2CH 4 + e-  CH 5 + and C 2 H 5 + CH M  MH + + CH 4 The excess energy in MH + is the difference in proton affinities between methane and M, usually not enough to give extensive fragmentation

Electrospray 5 kV voltage on a needle Nebulization gas Produces gas-phase protonated analytes Little to no fragmentation Multiple charging 10  M angiotensin at 5  l/min direct infusion, MW 1269

] m/z Relative Abundance

MALDI Matrix -UV absorber, ex. picolinic acid, cinnimic acid Singlely charged ions Need mass analyzer with a large m/z range – TOF Laser pulse as opposed to continuous source

Mass Analyzers Low resolution –Quadrupole –Ion trap High resolution –TOF time of flight –Sector instruments (magnet) Ultra high resolution –ICR ion cyclotron resonance

Resolution R = m/z/  m/z Unit resolution for quad and trap TOF up to FT-ICR over –MALDI, Resolve 13 C isotope for a protein that weighs –Resolve charge states 29 and 30 for a protein that weighs 30000

High vs low Res ESI Q-TOF, ICR –complete separation of the isotope peaks of a +3 charge state peptide –Ion abundances are predictable –Interferences can be recognized and sometimes eliminated Ion trap, Quad –Unit resolution

MVVTLIHPIAMDDGLR

Exact Mass Determination Need Mass Spectrometer with a high mass accuracy – 5 ppm (sector or TOF) C 9 H 15 NO 4, FM (mono-isotopic) Mass accuracy = {(Mass Error)/FM}*10 6 Mass Error = (5 ppm)( )/10 6 =  amu

Mass accuracy Mass Error = (5 ppm)( )/10 6 =  amu to (only 1 possibility) Sector instruments, TOF mass analyzers How many possibilities with MA = 50 ppm? with 100 ppm?

Quadrupole Mass Ion Filter

Ion Trap

Time of Flight -TOF

Where: m i = mass of analyte ion z i = charge on analyte ion E = extraction field t i = time-of-flight of ion l s = length of the source l d = length of the field-free drift region e = electronic charge (1.6022x10-19 C)

TOF with reflectron

Sector instruments

FT-ICRMS 181/MS_FT-ICR_Huffman_Abraham.pdf

CID or MS-MS –MS-MS sequencing the peptides or oligonucleotides structural characterization of drugs and metabolites Assay development, sensitivity enhancement

HPLC-MS-MS time response chromatogram m/z

hybrids Ex.Q-TOF –Trap has excellent sensitivity (can store essentially all ions), mass selectivity (can store ions of a particular m/z ratio –TOF is a high resolution mass analyzer Triple quadruple –Neutral loss scan

HPLC-MS Reverse-phase HPLC –Separation of involatiles (peptides) –The lower the flow the greater the sensitivity –Column ID (300  m – 50  m)

Proteomics using LC-MS Protein identification, characterization, quantification Extract proteins, fractionate proteins (typically using 2D-gel electrophoresis) Digest protein(s) with a protease to produce peptide mixture (lysine, arginine) LC-MS-MS analysis Database searching identifies proteins –Mascot, Expasy (tools)

Time (min) Relative Abundance RP-HPLC Separation of a Tryptic Digest of BSA Peptide used in following illustration

Mass Spectrum of a Tryptic Peptide from BSA (M+2H) +2 (M+H) +

L S Y E Y L F S G D A F L G S F L Y E Y S R MS-MS Spectrum D A F L G S + m/z 590 Residue mass S87.0 Y E L F G 57.0

LC-MS-MS analysis Characterization of synthetic processes Drug metabolism studies – structural elucidation of metabolites Quantification of polar molecules in biological samples – NAD

NAD Assay Goal to determine the relative importance of the different biosynthetic pathways. Stable isotopic incorporation

NAD Synthesized from Labeled Precursors NAD synthesized from a) 2 H 4 labeled nicotinic acid and nicotinamide (m/z 667) b) 13 C 5 labeled tryptophan (m/z 669) c) 13 C 6 labeled quinolinic acid (m/z 670)

The Experimental Strategy Culture cells in media containing isotopically labeled precursors for fixed time intervals Harvest and lyse the cells, extract the NAD, and quantitate the unlabeled and labeled NAD using reverse-phase LC-MS- MS

Sensitivity advantage m/z 664  m/z 542 m/z 692  m/z 562

Standard Curve 39 pts Detection Limit: 5 pg/  l or 35 fmol on column

Unlabeled NAD Internal Standard NAD synthesized from labeled nicotinamide Sample from experiment 1: Nicotinamide at 72 hrs m/z 664 m/z 692 m/z 667

Elemental Mass Spectrometry ICP-MS (inductively coupled plasma) SIMS-TOF (secondary ion mass spectrometry CRIMS

ICP-MS (vs. ICP-UV/vis) ICP (ch 10, pg ) ICP-MS (ch 11) A spark ignites flowing argon forming a self-sustaining plasma (T ≈ K) Sample is aspirated/pumped into plasma forming elemental cations and some simple polyatomic ions Ions are pushed into mass analyzer by high voltage

Isotope ratio mass spectrometry Elemental analysis (geologists, archeologist, isotope tracer studies) High resolution sector mass analyzers Faraday cups ThermoFinnigan Neptune CRI-MS (chemical reaction interface) –Converts all carbon to CO 2