LH2 Absorber Heat Load and Homeostasis. What has happened before… 1.Huge LH2 volumes, low heat deposition: Bubble chambers 2.Small LH2 volumes, low heat.

Slides:



Advertisements
Similar presentations
1 Ann Van Lysebetten CO 2 cooling experience in the LHCb Vertex Locator Vertex 2007 Lake Placid 24/09/2007.
Advertisements

Photo KEK March-28, 2002 MICE Absorber and Test Cryostat Shigeru Ishimoto (KEK) Shoji Suzuki (KEK) Edgar Black (IIT) Mary Anne Cummings (NIU) (1) MICE.
10 June 2006MICE Collaboration Meeting CM-151 Can MICE Solid and Liquid Absorbers be Characterized to better than 0.3 Percent? Michael A. Green 1, and.
Feb. 9, 2002 Mucool FNAL LH2 Absorber R & D Mary Anne Cummings NIU Illinois Consortium for Accelerator Research (IIT, NIU, UC, UIUC), U Miss Oxford U.
8/12/2002 Bob/RolAbsorber Review/GH2 status1 Gaseous H 2 Absorber Status IIT and Muons, Inc. Chuck Ankenbrandt, Ed Black, Kevin Cassel, Bob Hartline, Rol.
Lh 2 target for an 11 GeV Møller - prospect - S. Covrig hall c, jlab 14 august 2008 hp lh 2 targets for pv q weak target design cooling.
1 Cooling the Hydrogen (Helium) Absorbers with Small Coolers Michael A. Green University of Oxford Department of Physics Oxford OX1 3RH, UK MICE Video.
Mike Fitton Engineering Analysis Group Design and Computational Fluid Dynamic analysis of the T2K Target Neutrino Beams and Instrumentation 6th September.
LH2 Absorber Design Mary Anne Cummings MICE Safety Review LBL Dec 9, 2003.
The issue: A non-standard thin window design  No closed form expression for maximum stress vs. volume pressure  FEA (finite element analysis): geometry.
Proposal for Convection Absorber Test with Hydrogen at Fermilab Barry Norris Representing colleagues in BD/Cryogenics February 21, 2003.
MICE LH2 Operating Parameters Mary Anne Cummings MICE October ‘02 LBL Oct. 24, 2002.
The structural and Fluid flow analyses of the Hydrogen Absorber Window for the Muon Cooling collaboration project Presented at the MICE meeting at IIT.
MUCOOL Collaboration Meeting February 2002 Steve Geer February 2002.
MuCool Absorber Review meeting FermiLab, Chicago 21 – 22 February 2003 Fluid Flow and Convective Heat Transfer Modelling by Wing Lau & Stephanie Yang Oxford.
Absorber/vacuum windows and absorber assembly 1.Window Requirements 2.MICE experimental constraints 3.Welded vs. non-welded windows 4.Installation 5.Testing.
2/7/2002 RolMUCOOL/MICE1 20b. Gaseous Energy Absorber, 21a. High Pressure RF Cavities New Money for New Approaches DOE Small Business Innovation Research.
MTA Cryostat & cooling loop design Christine Darve Fermilab/Beams Division/ Cryogenic Department/ Engineering and Design Group Preparation of the Mucool/MICE.
MICE Collaboration meeting at Columbia University, New York 12 – 14 June 2003 How Liquid Hydrogen behaves thermally in a Convective Absorber by Wing Lau,
11/26/2002Edgar L Black IIT MICE Video Conference November 27, 2002 Summary of safety implementation for proposal.
LH2 Absorber Design Mary Anne Cummings MICE Safety Review LBL Dec 9, 2003.
March 14, 2003 MICE Absorber/Coil Integration MICE LH2 Absorber 1.Assembly 2.Safety 3.Staging 4.Instrumentation.
A discussion paper for the Absorber Review pre-meeting on February 11 th 2003 On 3-D Fluid Flow calculations on the 22cm Absorber Window By Stephanie Yang.
MUTAC Review 3/16/06 A. Bross MuCool Overview and Plans Muon Cooling R&D MUTAC Review March 16, 2006 A. Bross.
MICE absorber and Window / flow Design Wing Lau, Giles Barr & Stephanie Yang Oxford University MICE Meeting Berkeley, Oct 2002.
LH2 Absorber Design Mary Anne Cummings MICE Safety Review LBL Dec 9, 2003.
Mucool LH2 Absorber Progress and Pauses Mary Anne Cummings FNAL August 12, 2002.
LH2 Manifold R & D 1.The driving physics issue in Mucool LH2 R & D is now fluid flow and heat removal 2.Two separate absorber designs 1.What is “certification”?
Overview of Experiment and Parameter Choices presented by Giles Barr.
Mucool cryo-design Christine Darve Fermilab/Beams Division/ Cryogenic Department 8/12/02.
Absorber Design Details Mary Anne Cummings MICE MEETING Columbia June 13, 2003.
Mucool Test Area Cryostat & cooling-loop design Christine Darve Fermilab/Beams Division/ Cryogenic Department/ Engineering and Design Group MuCool / MICE.
17 March 2005Edda Gschwendtner1 MICE Cooling Channel: Can we predict cooling to ? Edda Gschwendtner Challenge Systematics Cooling Channel Beam Line.
CFD team supports CERN development 19 May M.Battistin CERN May 19 th 2011 C omputational F luid D ynamics team C omputational F luid D ynamics team.
WINWARD TECHNOLOGIES, LLC
MICE CM February 08Jean-Sébastien GraulichSlide 1 Detector DAQ Hardware Status o Introduction o Preliminary list o Plan for action o Summary Jean-Sebastien.
Emittance measurement: ID muons with time-of-flight Measure x,y and t at TOF0, TOF1 Use momentum-dependent transfer matrices iteratively to determine trace.
Edgar L. Black MUCOOL ADVANCED M.T.F. & M.I.C.E. LAYOUTS August 12-13, 2002 Edgar L. Black IIT.
CD-03/12/06 – IIT NFMCC meeting Flow Absorber Possibilities C. Darve Fermi National Accelerator Laboratory Batavia, IL, 60500, USA Neutrino Factory & Muon.
M. A. C. C. NFMCC UCLA Jan 31, 2007 LH2 Absorber Status Mary Anne Cummings NFMCC UCLA January 31, 2007 Muons, Inc.
Status of RFCC-Module Development Derun Li Center for Beam Physics Lawrence Berkeley National Laboratory MICE Collaboration Meeting at INFN-LNF, Frascati,
201 MHz NC RF Cavity R&D for Muon Cooling Channels
Emittance measurement: ID muons with time-of-flight Measure x,y and t at TOF0, TOF1 Use momentum-dependent transfer matrices to map  path Assume straight.
A. Bross MUTAC Meeting BNL April MuCool Overview Muon Cooling R&D Alan Bross.
Hydrogen system R&D. R&D programme – general points Hydrogen absorber system incorporates 2 novel aspects Hydrogen storage using a hydride bed Hydrogen.
LH2 Absorber Review 1.R&D Motivation 2.Windows (absorber and vacuum) 3.Absorber manifold designs and flow tests 4.System integration 5.Near term plans.
CRYOGENICS FOR MLC Cryogenic Piping in the Module Eric Smith External Review of MLC October 03, October 2012Cryogenics for MLC1.
Current Status and Possible Items around ‘neutrino beam’ Horn Target Remote maintenance tools Decay volume window and collimator muon monitor Many items.
LH2 Absorber Program and Plans Mary Anne Cummings MUTAC Review FNAL Jan 14, 2003.
MCTF 8/17/06 A. Bross MTA Activities and Plans MCTF August 17, 2006 A. Bross.
MICE at STFC-RAL The International Muon Ionization Cooling Experiment -- Design, engineer and build a section of cooling channel capable of giving the.
LH2 Safety Issues for MICE 1.O2/LH2 separation 2.No Ignition sources near LH2 3.Adequate ventilation 4.Affects: Windows: absorbers and vacuum Primary and.
NFMCC Meeting 3/12/06 A. Bross MuCool Overview Muon Cooling R&D NFMCC Meeting March 12, 2006 A. Bross.
Apr MUTAC 2005 LH2 Absorber Window R & D Program Mary Anne Cummings MUTAC Review LBL April 26, 2005.
29 September 2006M.Sakuda NuFact06 Asian Regional Outlook (Japan) -by Y.Kuno (Osaka) (1) SuperBeam (T2K) (2) J-PARC current upgrade plan (3) T2HK or T2KK.
NFMCC Meeting 3/12/06 A. Bross LiH Absorbers Muon Cooling R&D NFMCC Meeting March 12, 2006 A. Bross.
1 LARP Collimator Engineering E. Doyle 2/3/05. 2 Review: SS Thermal Simulation 150mm OD 25mm wall Simply supported Heat: 1hr beam life, FLUKA results,
MICE LH2 Absorber Safety Mary Anne Cummings Edgar Black (IIT) Abingdon, UK Oct. 30, 2003.
1 Alan Bross AEC March 31, 2008 MuCool RF Program Muon Cooling R&D Alan Bross.
Performance analysis of cryogenic system and cryomodules for the complete superconducting linear accelerator at IUAC, New Delhi. T S Datta ( On behalf.
CRYOGENICS FOR MLC Cryogenic Principle of the Module Eric Smith External Review of MLC October 03, October 2012Cryogenics for MLC1.
S1 global: thermal analysis TILC09, April 19th, 2009 Serena Barbanotti Paolo Pierini.
MUTAC 04 - April A. Bross MuCool Overview and Plans Muon Cooling R&D MUTAC 04 A. Bross.
Mitglied der Helmholtz-Gemeinschaft Summary of the target session of the IEB Workshop June 19, 2015 | Alexander Nass.
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
MuCool Test Area Dedicated facility built at the end of the Linac to address MuCool needs RF power 805MHz, 201MHz)
Status of work on the cryostat design
Linac Test Area Instrumentation
Operation experience of cryogenic system and cryomodules for the superconducting linear accelerator at IUAC, New Delhi. T S Datta ( On behalf of Cryogenics.
Linac Test Area Instrumentation
Presentation transcript:

LH2 Absorber Heat Load and Homeostasis

What has happened before… 1.Huge LH2 volumes, low heat deposition: Bubble chambers 2.Small LH2 volumes, low heat deposition: FNAL E866 …here density fluctuations are an issue: 3.Medium volumes, large heat deposition: Sample, Slac E158 Our challenge: Large heat deposition and beam path is through entire volume of absorber! 1. Liquid must move everywhere 2. Need gauge of temperature and density uniformity

Sample and E158 Targets E158 target ~60 liters Sample target ~25 liters  Beam size ~ 2mm: defines small turbulence scale, and is small part of total volume  Calibration was total  measurement

Muon Ionization Cooling xx zz P1P1 P2P2     absorber accelerator absorber P1P1  With transverse focussing (solenoid) : Multiple scattering Heating term (Mult.Scatt.)Cooling term + RF cavity  Need to minimize heating!

Internal heat exchange: Convection is driven by heater and particle beam.Heat exchange via helium tubes near absorber wall. Flow is intrinsically transverse. Convection absorber design Output from 2-dim Computational Fluid Dynamics (CFD) calcs. (K. Cassel, IIT). Lines indicate greatest flow near beam center. Qualitatively demonstrated but parameters need to be measured. Prototyping of this design is being done by Shigeru Ishimoto et al at KEK.

Forced-Flow Absorber Design Mucool ~ 100W (E. Black, IIT) Large and variable beam width => large scale turbulence Establish transverse turbulent flow with nozzles External Heat Exchange:  For ~ 8W/cm heat deposition, need to cycle 0.05 volumes/sec LH2 (e.g. 240W/30cm).  Nozzle design complicated - needs prototyping and testing.

So far… Three dimensional LH2 flow simulations (W. Lau) Testing 3-dimensional simulations with water flow test at NIU 1.Nozzle arrangement 2.Heat application 3.Cryo tests Schlieren testing of convection flow (water) test at ANL

Flow Tests Proposed Three test modes (E.Black): 1.Absorber manifold, two plastic windows: Absorber filled with water at room temp. – the pattern of flow will be photographed by circulating water from inlet to outlet using a luminous die injected at inlet. Hard to get real window volume flow picture this way. 2.Absorber manifold, one plastic windows, one aluminum window Absorber subjected to a heat source. Infrared pictures taken (for forced- flow and convection absorber type). Distortion from heat distribution in window. 3.Absorber manifold, two thin Al windows, cryogenic: Absorber integrated into a cryo system, operating in test mode with extreme temperature and pressure variations considered for safety. Yet to have a definitive determination of adequate probe placement.

Infrared flow test setup

Now, the questions… 1.What computations are helpful? 2.Are flow/convection predictions “linear”? 3.What tests will be useful, and how quantitative can they be? 4.What level of instrumentation will convince us of sufficient temperature uniformity? 5. How will convection and force-flow models be evaluated?

At this meeting… Let’s decide what activity to pursue that: 1.Makes sense for the LINAC Cryo program next year 2.Contributes substantively to the MICE tech. review meeting in Oct.