Advanced GPC Part 2 – GPC and Light Scattering

Slides:



Advertisements
Similar presentations
Viscosity of Dilute Polymer Solutions
Advertisements

Introduction to Chromatography
Introduction to Light Scattering A bulk analytical technique
Solution Thermodynamics Richard Thompson Department of Chemistry University of Durham
Chapter 5 Distributed Force. All of the forces we have used up until now have been forces applied at a single point. Most forces are not applied at a.
Lecture 17. Light Scattering/Viscometry. What is light scattering? In the lab…
CHEMISTRY ANALYTICAL CHEMISTRY Fall
Foundation GPC Part 4 – Organic Gel Permeation Chromatography Columns and Applications.
Foundation GPC Training Course Theory. Nomenclature Gel Permeation ChromatographyGPC Size Exclusion ChromatographySEC Gel Filtration ChromatographyGFC.
1 HPLC Lecture Mobile Phase Selection in Partition Chromatography Optimization of the mobile phase composition and polarity is vital for obtaining.
Internal – External Order We described symmetry of crystal habit (32 point groups) We also looked at internal ordering of atoms in 3-D structure (230 space.
Regression Analysis Once a linear relationship is defined, the independent variable can be used to forecast the dependent variable. Y ^ = bo + bX bo is.
Chemical Analysis Qualitative Analysis Quantitative Analysis Determination “Analyze” a paint sample for lead “Determine” lead in a paint sample.
The use of light scattering in characterizing lignin.
Chem. 31 – 4/8 Lecture. Announcements I Exam 2 – Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (up to and including retention.
Foundation GPC Part 2 – Basic Gel Permeation Chromatography
Advanced GPC Part 1 – GPC and Viscometry
Chromatographic detectors for Liquid Chromatography.
Advanced GPC Part 2 - Polymer Branching. Introduction  Polymers are versatile materials that can have a variety of chemistries giving different properties.
METO 621 Lesson 5. Natural broadening The line width (full width at half maximum) of the Lorentz profile is the damping parameter, . For an isolated.
So are how the computer determines the size of the intercept and the slope respectively in an OLS regression The OLS equations give a nice, clear intuitive.
Unit 2, Part 3: Characterizing Nanostructure Size Dr. Brian Grady-Lecturer
CALIBRATION METHODS.
Chemometrics Method comparison
Instrumental Analysis
Drs. Wei Tian & Yanhui Chen Sep-Dec Main Content Chromatography Analysis Gas Chromatography (GC) High Performance Liquid Chromatography (HPLC)
ADVANCED BIO-FRIENDLY POLYMERS Igor Lacík Gel permeation chromatography – a tool for determination of molar mass of polymers.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 0 The Analytical Process Copyright © 2007 by W. H.
Dr. Richard Young Optronic Laboratories, Inc..  Uncertainty budgets are a growing requirement of measurements.  Multiple measurements are generally.
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
Static & Dynamic Light Scattering First quantitative experiments in 1869 by Tyndall (scattering of small particles in the air – Tyndall effect) 1871 –
EM propagation paths 1/17/12. Introduction Motivation: For all remote sensing instruments, an understanding of propagation is necessary to properly interpret.
Determination of Crystal Structure (From Chapter 10 of Textbook 2) Unit cell  line positions Atom position  line intensity (known chemistry) Three steps.
1 Atomic Absorption Spectroscopy Lecture Emission in Flames There can be significant amounts of emission produced in flames due to presence of flame.
Static Light Scattering. Outline of Static Light Scattering FMeasurement system FRayleigh scattering FStatic structure factor FForm factors FPractical.
Chapter 4 Linear Regression 1. Introduction Managerial decisions are often based on the relationship between two or more variables. For example, after.
Quality Assurance How do you know your results are correct? How confident are you?
Ch 24 pages Lecture 9 – Flexible macromolecules.
FIG. 5.1 Multiple scattering is viewed as a random walk of the photon in diffusing wave spectroscopy (DWS)
CALIBRATION METHODS. For many analytical techniques, we need to evaluate the response of the unknown sample against the responses of a set of standards.
Proteins separation and analysis using Fast Protein Liquid Chromatography Ayelet David, Ph.D Dept. of Clinical Pharmacology.
Congresso del Dipartimento di Fisica Highlights in Physics –14 October 2005, Dipartimento di Fisica, Università di Milano An application of the.
1 UV-Vis Absorption Spectroscopy Lecture Measurement of Transmittance and Absorbance: The power of the beam transmitted by the analyte solution.
Light Scattering (pp in Shaw and pp in Hiemenz and Rajagopalan) Introduction Rayleigh Scattering Debye Scattering, Zimm Plots Dynamic.
Chapter 8: Simple Linear Regression Yang Zhenlin.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Correlation They go together like salt and pepper… like oil and vinegar… like bread and butter… etc.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
ERT 207 Analytical Chemistry ERT 207 ANALYTICAL CHEMISTRY Dr. Saleha Shamsudin.
Berat Molekul Polimer.
Chapter 1: The Nature of Analytical Chemistry
Introduction to Polymer Physics
Solution Concentration.  Lesson Objectives  Describe the concept of concentration as it applies to solutions, and explain how concentration can be increased.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Chemistry 367L/392N Macromolecular Chemistry Lecture 10.
30/09/2016 Irradiance and Inverse square law. Read Summary Notes, page 65, “Irradiance and Inverse square law.” The irradiance of light, I, is defined.
Fundamentals of Analytical Chemistry Eighth Edition.
Gel Permeation Chromatography Size Exclusion Chromatography
Static Light Scattering Part 2: Solute characteristics
786 Static Light Scattering Part 1: Aggregate Structure & Internal Dynamics.
Applications of UV-Vis Spectroscopy
Internal Standard method (experiment lab-4)
NEPHELOMETRY AND TURBIDIMETRY
Light scattering method Introduction: The illumination of dust particles is an illustration of light scattering, not of reflection. Reflection is the deviation.
Utilizing Spectrophotometry in Life Science
No notecard for this quiz!!
Light Scattering Biophysics
Propagation of Error Berlin Chen
Advanced Characterization for Proteins and Polymers
Presentation transcript:

Advanced GPC Part 2 – GPC and Light Scattering

Introduction As well as viscometers, the use of light scattering detector is becoming more prevalent Light scattering detector have the same advantages as viscometers, they give molecular weights that are not dependent on calibrants With light scattering detectors, you don’t even have to calibrate the column! They also give other information relating to the polymer molecules in solution They are however fairly difficult to use and data interpretation is complex This presentation outlines light scattering and the combination of light scattering and viscometry, triple detection

Light Scattering of Polymers In static light scattering, coherent incident radiation (usually a laser) interacts with components of the polymer backbone in a small scattering volume Excitation of the polymer chain results in re-emission of the radiation at the same wavelength and frequency but at variable intensity Measurement of the intensity of the scattered radiation allows the calculation of molecular weight and the chain dimensions

Determination of Molecular Weight by Light scattering We measure Rθ, the excess scattering of light from the solute in the solvent For any given solute/solvent system, we assume K is a constant The scattering function Pθ relates to the size and shape of the molecule The virial expansion describes intermolecular interactions

The Zimm Method The classic way of analysing light scattering data that shows scattering is the Zimm plot We plot K*c/Rθ versus sin2(θ/2) + c and perform a double extrapolation of the plot to zero angle and concentration Calculation of molecular weight from the intercept and virial coefficients (more on this later) from the slope of the plot The data shown is for a sample of polytetrahydrofuran Mw 2,000,000 g/mol in iso-propanol at 46ºC

Light Scattering with GPC The Zimm method is a batch method where we analyse a sample at a range of concentrations and molecular weights This is not appropriate for a GPC method where the sample is flowing through the light scattering cell So we make some simplifications… If the molecule under investigation is small (more on this later), then Pθ is equal to one and can be ignored The virial expansion describes intermolecular interactions, so we can assume that under very dilute conditions these terms are equal to zero

Scattering for Larger Molecules If we are looking at smaller molecules, we can measure the light at any angle and determine molecular weight from the simplified equation However, when the molecules are large (greater then 1/20th the wavelength of the light), the simplification does not work because Pθ is not equal to one This causes a problem as we now need to know Pθ But it is also useful, as Pθ is related to s, the radius of gyration, a measure of the size of the molecule If we can measure Pθ, not only will we be able to determine the molecular weight of the polymer using the light scattering equation, but we should be able to determine the molecular size

Molecular Size and Light Scattering From the classical static light scattering equation, the size of the scattering molecule can be measured, the s term in the light scattering equation This is called the radius of gyration, also known as Rg The value of <s2>z, the mean square radius of gyration, is related to the characteristic dimensions of different molecular shapes are shown below For rods (length of rod)2 = 12<s2>z For spheres (radius of sphere)2 = 5<s2>z/3 For coils (root mean square end to end distance)2 = 6<s2>z The value of s is very useful as it can tell us a lot about the polymer

What Does Radius of Gyration Really Mean? Rg is the radius of gyration, the root mean square distance of the points of mass on the polymer chain from the centre of gravity Rh is the hydrodynamic radius, the average radius of a freely rotating molecule and associated solvent, typically larger than Rg Both terms are used in polymer science because polymer molecules in solution do not conform to the static hard sphere model

Why Does Pθ Change with Big Molecules? When the scattering molecule is small, Pθ is equal to unity As the molecule grows in size compared to the wavelength of the light, Pθ falls below one This is because the molecule stops acting like a single point scattering light, and starts acting like a collection of points This causes interference in the light scattered from the different points which affects the total amount of scattered light we can measure The degree of interference is extremely angular dependent Trying to measure this interference affect is why light scattering measurements are often performed at different angles or at more than one angle

Angular Dependence of Scattering from Large Molecules Large molecules can be considered collections of points that each scatter light If we look at the light in the forward direction (called the zero angle), any light that is scattered from any point will be in phase, so there is no interference and we get an accurate measurement of intensity of scattered light However, if we look at the light scattered at higher angles, we get more and more destructive interference that results in a decrease in the observed amount of scattered light We only get the true amount of scattered light at the zero angle

Consequences of Angular Dependence

Results and Angular Dependence Angular dependence can affect the accuracy of the calculated results, especially at high molecular weight (large molecular sizes) If we measure at a single angle, the closer to the zero angle, the less angular dependence in the scattered light intensity and the greater the accuracy of the calculated result We can’t measure at the zero angle, as the rest of the unscattered laser beam comes through at that point! We must choose another angle Generally, the closer to the zero angle the better the accuracy of the result as we obtain closer to the true scattering intensity, but the noisier the data and the lower the precision of the result The higher the angle of measurement the lower the accuracy due to interference effects, but the better the quality of data and the higher the precision in the result We have a dilemma!

High Angle Light Scattering Analysis of PS Standard, Mw = 2x106 g/mol At high angle, the large polymer molecule gives asymmetric scattering and an underestimation of the molecular weight is made

Low Angle Light Scattering Analysis of PS Standard, Mw = 2x106 g/mol At low angle, the large polymer molecule gives noisy light scattering data with poor precision resulting in large errors

Multi Angle Extrapolations and the Dissymmetry Technique These problems are alleviated by the use of a multi angle system In these systems, irrespective of the type of calculation performed, multi data points are used to extrapolate to the zero angle Errors tend to be much lower than single angle calculations Different designs of instrument employ different numbers of data points to make the extrapolation The Dissymmetry method employs two or three angles, typically 135°, 90° and 45°, if other angles are used further corrections are required The ratio of these intensities, Zd, is known as the dissymmetry of scattered light Assuming we know the shape of the molecules under analysis, we can used Zd to determine the particle scattering function, Pθ From this value we can correct the scattering value at 90° to give accurate molecular weight and allow us to calculate radius of gyration

Multi Angle Light Scattering Analysis of PS Standard, Mw = 2x106 g/mol A much better result is obtained if more than one angle of data is used allowing extrapolation of the calculated result

RIsignal = KRI (dn/dc) C Measuring Light Scattering - What do we need?… A light scattering detector that measures the intensity of light scattered at different angles A concentration detector that tells us how much material is eluting from the column Can be any type that gives a response proportional to concentration Typically a differential refractive index detector is used DRI detector response proportional to concentration and dn/dc Operation identical to conventional GPC, determines the concentration of material eluting from a GPC column RIsignal = KRI (dn/dc) C

The Importance of dn/dc The refractive index increment, dn/dc, is the amount by which the refractive index of a solution changes with changing solute content Refractive index detector give a response proportional to dn/dc Light scattering detectors give a response equal to (dn/dc)2 The term is extremely important for light scattering Light scattering calculations assume that dn/dc is a constant For any given polymer/solvent combination, dn/dc is a constant above a few thousand molecular weight For copolymers and blends where the dn/dc of separate components are not the same, light scattering cannot be meaningfully applied The values of dn/dc are listed for a range of polymers and solvents

Typical dn/dc Values

Effect of Measurement System on Calculated Data We can measure at lots of angles if we like Generally, it does not affect the data unless the molecule is very large This data is for linear polystyrene in THF at 25C from an 18 angle light scattering detector and a two-angle light scattering detector (Terao, Mays, EPJ (2004)) Very little difference in molecular weigh averages and radius of gyration data between the multi angle and the two angle data sets

The Conformation Plot A Conformation plot of log Rg versus log M should give a straight line K and slope vary between different solvents and polymers The slope gives an indication of the conformation of the polymer in solution

PL-LS 45/90 Specifications Scattering angles: 45° & 90° Wavelength: 650nm ± 30nm (red laser) Laser power: 25mW Cell Volume: 10µl

GPC/Light Scattering Experimentation No column calibration necessary Calculate detector constant (Kls) using one of the standards for which molecular weight and concentration is known For unknown sample, for each slice across the distribution determine molecular weight directly from the LS

GPC/Light Practical Considerations Eluent - Use high quality solvent, filter before use to remove particulates (e.g. 0.02um). Choose solvent to give good dn/dc for optimum LS detector response Injector - Dirty rotor seal can contribute to excess noise immediately after switching valve from load to inject position Columns - Column shedding can contribute to baseline noise, bleed decreases with time, special low shedding columns available (e.g. PLgel MIXED LS) Sample preparation - Polymer solutions must be prepared at accurate concentration, take care with samples containing solvents or fillers. Use higher concentrations for lower molecular weight polymers

Typical Chromatograms

Analysis

Butyl Rubber Application Light scattering is used to generate the log M versus retention time plot Rg can be calculated as the polymer is high in molecular weight

Comparison of GPC/Viscometry and GPC/LS Sample of polyethylene analysed by GPC/Viscometry with Universal Calibration and GPC/LS Both methods give molecular weights that are not dependent on the chemistry of any calibration standards Universal Calibration created with polystyrene narrow standards

Calculated Molecular weight Data and Data Fit Slice molecular weights used to create log M versus Rt plots Data fitted and extrapolated over the entire range to generate molecular weight distributions Very similar results, upward curvature in LS data is an artefact

Analysis of Polyesters Columns: 2 x PLgel 5µm MIXED-C Eluent: Tetrahydrofuran Flow rate: 1.0 ml/min Temperature: 40˚C Detector: PL-GPC 50 Plus DRI and PL-LS 45˚/90˚ light scattering detector Example chromatogram of one sample

Overlaid molecular weight distributions of two samples show clear differences in molecular weight

Triple Detection Combining light scattering and viscometry detection gives the most information from a Multi detector GPC experiment IV from the viscometer, molecular weight from the light scattering detector, branching from either IV or Rg Molecular weights generated by triple detection are more accurate than those from light scattering as a correction for the shape factor can be applied based on the IV value

Analysis of Polyacrylamide Columns: 2xPLaquagel-OH MIXED 8µm Eluent : 0.2 M NaNO3 0.1M NaH2NO3, pH 7 Flow rate: 1.0 ml/min Temperature: 40˚C Detector: PL-GPC 50 Plus DRI, PL-BV 400RT viscometer, PL-LS 45/90 Example chromatograms of a sample

Example molecular weight distribution

Example Mark-Houwink plot

Analysis of Polybutadiene Columns: 2 x PLgel 5µm MIXED-C Eluent: Tetrahydrofuran Flow rate: 1.0 ml/min Temperature: 40˚C Detector: PL-GPC 50 DRI, PL-BV 400RT viscometer and PL-LS 45˚/90˚ light scattering Example chromatograms of one sample

Small differences between the molecular weight distributions of two samples

Overlaid Mark-Houwink plots of two samples showing the presence the presence some structural differences

Analysis of Natural Rubber Column(s): 3 x PLgel 10µm MIXED-B Eluent : Toluene Flow rate : 1.0 ml/min Temperature : 50°C Detector : PL-GPC 50 Plus DRI and PL-LS 45˚/90˚ light scattering detector Example chromatograms of one sample

Large differences between the molecular weight distributions of two samples

Complex Mark-Houwink plots indicate the materials are not identical

Summary Light scattering is a powerful tool for the analysis of polymers allowing the calculation of molecular weight without the need for a column calibration The theory of light scattering is complex and the treatment of the data is very mathematical Different light scattering systems treat the data in different ways Multi angles have a strong advantage over single angle systems Combinations of light scattering with viscometry expands the GPC experiment considerably