Investigating Cartilage Stress Dennis Cody November 22, 2004
Outline History PTC & Pro/Engineer Stanford VA – Investigation of Stress in Cartilage Description of Patellofemoral Pain. Determine when bone can be assumed rigid. Understand apparent discrepancies in literature. PTCStanfordVA
Parametric Technology Corporation 5 years in Quality Assurance – Senior QAE Software: Pro/Engineer, Pro/Mechanica, Pro/Intralink Transition to new defect tracking database Desire to enhance people’s lives and health PTC
Stanford – Design and Prototype Tools for Surgical Procedure Implant pegs: placement, depth, diameter, angle Method of creating peg holes Tools: Cutting Block Depth Resection Gauge Drilling Template Template Impactor Posterior Peg Impactor Tibial Trial Tibial Spacer PTCStanford
Outline History PTC & Pro/Engineer Stanford VA – Investigation of Stress in Cartilage Description of Patellofemoral Pain. Determine when bone can be assumed rigid. Understand apparent discrepancies in literature. PTCStanfordVA
Outline Determine when bone can be assumed rigid. Understand apparent discrepancies in literature. When looking at stresses in cartilage: PTCStanfordVA
Motivation - PFPS What is PF Pain Syndrome? Anterior knee pain Associated with repetitive exercise Cause difficult to determine Muscle imbalance Attachment Bone shape, alignment… BackgroundMethodsResults
Objective Obtain PF joint data in young adult volunteers using non-invasive techniques. Kinematics Kinetics Contact areas Stresses Focus: From static MR Images, create a finite element model that can be used for analyses BackgroundMethodsResults VA
Hypothesis Subjects with PF pain will have elevated cartilage stresses (compared to age and activity matched subjects without PF Pain), either because of increased PF forces and/or decreased PF contact areas. Assumption to test: When looking at patellar and femoral cartilage stresses due to physiological loads, the underlying bone can be treated as a rigid material. BackgroundMethodsResults VA
Background Modeling and solving models with bone elements is expensive. Some studies consider bone as a rigid material. (Li et al., 2001, Zhang et al., 1999) Others consider the bone elements. (Beaupré et al., 2000, Brown et al., 1984) BackgroundMethodsResults VA
Background – Previous Work 3D Model of tibio-femoral joint (Donahue et al., 2002) Model with bone Model with rigid backing No difference of more than 2% BackgroundMethodsResults VA
Background – Previous Work Ideal model with plug and indentor (Brown et al., 1984) Cancellous bone modulus value impacts effect of rigid implant in bone Impactor has small radius smaller than in PF joint? BackgroundMethodsResults VA
Background – Previous Work AuthorSectionThickness (mm)Modulus (MPa) Beaupré Cartilage36 Subchondral12000 Cancellous16200 Brown Cartilage~ Subchondral~ Cancellous~ Donahue Cartilage 3D model of 30 yr old specimen, varying thickness 15 Subchondral Cancellous400 BackgroundMethodsResults VA
Methods Contact formulation Plane Strain Cancellous modulus Subchondral bone thickness Cartilage bone interface radius BackgroundMethodsResults Figure modified from Beaupré et al., VA
Model Model hemisphere contacting a plate (axisymmetric) Allows curved and flat surface Two models: Cartilage and bone elements BackgroundMethodsResults VA
Model Model hemisphere contacting a plate (axisymmetric) Allows curved and flat surface Two models: Cartilage and bone elements Cartilage with rigid backing BackgroundMethodsResults VA
Methods – Plane Strain Master-Slave surface BackgroundMethodsResults VA
Methods – Plane Strain Master-Slave surface Hertz contact BackgroundMethodsResults Remove ABAQUS Series VA
Master-Slave surface Hertz contact Compare with results from Beaupré’s PE model Methods – Plane Strain BackgroundMethodsResults VA
Methods – Plane Strain Master-Slave surface Hertz contact Comparison with results from Beaupré’s PE model. PE vs. BackgroundMethodsResults VA
Methods – Axisymmetric Master-Slave surface Hertz contact Comparison with results from Beaupré’s PE model. PE vs. Axisymmetric BackgroundMethodsResults VA
Stress With Radius σ 1-max = 432 kPa σ 2-max = 396 kPa σ 3-max = 401 kPa σ 4-max = 407 kPa σ 7-max = 414 kPa σ 8-max = 420 kPa r 2r r F F F F 1-max 5-max 3.8% 2-max 6-max 4.4% 3-max 7-max 3.2% 4-max 8-max 3.2% 1-max 3-max = 1.08 5-max 7-max = 1.08 0% 2-max 4-max =.97 6-max 8-max = 0.98 1% = ? = ? r = 20.5 mm 2r = 40.5mm F = 230N Cart thk = 3.5 mm Subch bone = 0.5 mm Canc modulus = 600 MPa BackgroundMethodsResults ? = ? = ? = ? = VA σ 5-max = 449 kPa σ 6-max = 413 kPa
Stress With Load Stress With Load σ 5-max = 300 kPa σ 6-max = 294 kPa σ 7-max = 414 kPa σ 8-max = 420 kPa σ 3-max = 401 kPa σ 4-max = 407 kPa F σ 1-max = 292 kPa σ 2-max = 286 kPa F 2F 1-max 5-max 2.8% 2-max 6-max 2.6% 3-max 7-max 3.2% 4-max 8-max 3.2% 1-max 3-max = 0.73 5-max 7-max = 0.72 1% 2-max 4-max = 0.70 6-max 8-max = 0.70 0% = ? = ? r = 40.5 mm F = 115N 2F = 230N Cart thk = 3.5 mm Subch bone = 0.5 mm Canc modulus = 600 MPa BackgroundMethodsResults ? = ? = ? = ? = VA
Stress Patterns BackgroundMethodsResults VA
Trends in Results BackgroundMethodsResults Modulus (MPa) Thickness (mm) Octahedral ShearHydrostaticOI %0.68%0.53% %1.32%0.87% %1.36%0.30% %3.36%1.12% %3.47%0.34% %15.8%4.21% OI : Osteogenic Index = k * σ Octahedral Shear + σ Hydrostatic (k = 0.35) VA
Summary Contact model ran successfully in Abaqus Rigid assumption valid for healthy young subjects, probably not for osteoporotic subjects Model differences explain difference in results
Thank You