Integrating a Saving Energy controller in Existing Air Condition units Case Study.

Slides:



Advertisements
Similar presentations
Saving Energy, Timer & Automation Best Design Course 30 Minutes Test 10 Minutes TIS Training Program 2012, Rev 1.1
Advertisements

Click left mouse button to advance, back to return Refrigeration HVAC control & monitor system Presscon Network & Pressnet Software Click left mouse button.
Nano-10 based Building Automation System (BAS) Jesús BaezMarch, 2011.
RWD CONTROLLERS TECHNICAL
Venstar Thermostats T5800 & T6800 ColorTouch. Residential T5800: 7 day programmable, vacation mode Compatible with almost all types of equipment; HP,
CommercialPRO™ CommercialPRO 7000 Introduction Competitively priced that in most cases beats the competition Key features - Sleek design - Intuitive.
Total HVAC Control from anywhere Easy control that can save a fortune
Portable Classroom Controls Project Chuck Collins RCM Meeting April 27, 2007.
CONDITIONAIRE INTERNATIONAL LIMITED INTRODUCING THE AIR CONDITIONING ENERGY SAVER CONDITIONAIRE INTERNATIONAL LIMITED.
Conditionaire Ltd. INTRODUCING THE AIR CONDITIONING ENERGY SAVER CONDITIONAIRE INTERNATIONAL. LTD.
Make the most of your energy Head Office – Case Study.
Heat Recovery for Commercial Buildings
King Fahd University of Petroleum and Minerals Mechanical Engineering Department Presented by Mohammad A. Al-Muaigel /10/2004 National Energy.
A Proven Partnership When you look at business partners, you want someone who understands your unique challenges. Mostly, you want someone who can address.
MAS- The Ultimate Energy Saver  Breakthrough A.C. Saver  Intelligent and Programmable Device  Unmatched Guaranteed Savings and ROI  No Compromise.
PYRO-X De-Ice control devices Technical presentation 2013.
PYRO-STAG De-Icer Optimizer Controller Technical presentation 2013.
TAC - Intelligent Infrastructure and Energy Efficiency.
How to increase energy efficiency? Evaldas Paliliūnas.
Siemens Building TechnologiesRWD heatpump controllers Xavier Zabalegui/David Jefferson 1 January 2003 RWD Heat Pump controllers RWD Heat Pump Controllers.
PYROCON12 De-Ice controller User Operation Presentation 2013.
Make the most of your energy Make the most of your energy SM Add application photo in this area PowerLogic ® Branch Circuit Power Meter for data center.
Energy Smart Room GROUP 9 PRESENTERS DEMO DATE SPECIAL THANKS TO ADVISOR PRESENTERS Thursday April 19, 2007 Department of Electrical and Systems Engineering.
Renewable Technologies Available in Ireland Paul Kane.
Euroheat & Power Why is there not more combined heat and power?
Lecture Objectives: Model HVAC Systems –HW3 Asignemnet Learn about eQUEST software –How to conduct parametric analysis of building envelope.
Page 1Ethical Module David F. Miller Center for Retailing Education and Research Ethical Issues in China Retailing 5. Sustainability Issues in China Retail.
Melcotel TM Features and Benefits Melcotel - Introduction New features –Links with up to 250 room units –Settings reset –Automatic switch OFF –Setback.
IntelliCon ™ Product Line Manufactured by Intellidyne, LLC Distributed by: IMC.
Chilled water Meyrin consolidation Study 1 st Part Many thanks for their contribution to: Pasquale Alemanno, Fortunato Candito, Alexander Putzu.
Beckhoff Building Automation New Automation Technology HVAC-Library Exercise Air Conditioning System.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
Chilling at Penn: Weather-Analysis of Load Tool (WALT) Abstract: Penn’s MOD 7 plant supplies chilled water to the entire campus for its air- conditioning.
So… How does Smartcool achieve savings??.  Compressors use 70% of the energy in refrigeration and air conditioning systems.  The cooling cycle is dynamic.
Delivering Innovative Solutions Sun Power Technologies is committed to developing innovative, integrated power electronics solutions for the markets that.
Smartcool Systems Inc. Providing effective and reliable energy efficiency solutions for HVAC-R customers around the globe.
Home Guard Security System. Introduction & Basic Ideas Home Guard Security System.
Caclulating Payback period Installing alternative is an investment The cost (plus risk) must be less then the potential gain.
EXPLORING ALTERNATE WAYS OF COOLING SPACES. Addressing Current Issues:  Rising electric consumption  Suffering Environment  Need for more Action &
Day 10 Environmental Systems I Daylight as a primary lighting source Artificial lighting as a secondary source Room 102 Architecture Building.
GSM sites Cooling systems description Standard Air Conditioner SystemEmergency Cooling SystemEnergy Saving Cooling System Air Conditioner Cooling system.
Learning, our way Daikin Europe, Consulting sales section1 Understanding Client’s Needs and best Daikin solution.
Click left mouse button to advance, “back” to return Phasefale November 2007 Presscon Network Click left mouse button to advance, “back” to return.
Student Name USN NO Guide Name H.O.D Name Name Of The College & Dept.
October 2014 Rod Rabold Vice President, SERBCA Board of Directors SERBCA TECH TALK BAS Control Strategies for Energy Savings in Buildings SOUTHEAST.
Student Name USN NO Guide Name H.O.D Name Name Of The College & Dept.
Roof Top Unit Overview (MAGNUM) Visit us at Revision- 12/17/2015.
Week 6 The Energy Walk Through. Possible elements of a walk through Understand on-site information collection and listing of essential data for collection.
the compact air control solution
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Data Analytics – A Cost Effective Approach to Reducing Operating Costs Automatically “find what matters” in the data from building equipment systems and.
Power Consumption How do we measure the electricity we use? This presentation came from Virginia Tech and has not been edited by the Georgia Curriculum.
ENERGY SAVING AND EFFICIENCY OF AIR CONDITION & LIGHT SYSTEMS AT PUBLIC BUILDINGS Meitav-tec (Contel group)
SAI BHARATH SRAVAN KUMAR
Fan Coil Controller FC/S 1.1
Energy Management and Planning MSJ0210
The EndoCube.
Seminar On Energy Audit Submitted To: Submitted By:
Lecture Objectives: Discuss Final Project
High Quality ECONET Manufactured by Manor
Maniks Systematic and Adiabatic Econet System
Closing the Gap to Free Cooling in the Data Center
De-Ice control devices
Did you know? In the U.S. alone, buildings account for: 72% of electricity consumption
The EndoCube.
HOW TO SAVE MAXIMUM ENERGY IN YOUR COMPRESSORS INSTALLATION
The key to comfort and efficiency for heating and air-conditioning
SOLAR PANELS SAVING IN YOUR HOME!
Calibrated Energy Models: One New Change
Total HVAC Control from anywhere Easy control that can save a fortune
Presentation transcript:

Integrating a Saving Energy controller in Existing Air Condition units Case Study

TLC - Temperature Limit Control Unit requirements Fits to any existing A/C (Air Condition) system Does not require any modification in the existing controller of the A/C Hidden inside the A/C unit Enables limits for both Cooling and Heating Saving Energy will not disturb the users of the A/C Easy, quick and simple installation TLC – miniature Temperature Limit Controller

TLC – operation mode T1 – Return Air Temperature sensor T2 – Supply air Temperature sensor Supply 230VAC Supply 230VAC A/C controller output to compressor line To Compressor Heating Temp. Limit knob Heating Temp. Limit knob Cooling Temp. Limit knob Cooling Temp. Limit knob

TLC – Features Saves energy and electricity costs without disturbing the A/C users Overriding the energy waste of end-users who select high Heating set-point and low Cooling temperature set-point Very small unit that fits into any existing A/C system Very Simple (2 knobs) adjusting Easy installation – Does not require any external or internal preparations

Test procedure The test was made along 6 months in 4 different departments TLC was installed in each A/C on the output line from the control electric board of the A/C to the compressor 2 Time counters were installed in each A/C Counter 1 – on the line before the TLC (counting the hours that the A/C controller set the compressor to work) Counter 2 – on the line after the TLC (counting the hours the compressor is actually working)

Test procedure From the A/C control box To A/C compressor Counter 1Counter 2

Results by departments Energy Saving % Counter 2 (hours) (after TLC) Counter 1 (hours) (before TLC) AREA 60% Department 1 (Electric dept.) 39% Department 2 (Fire Safety dept.) 67%41124 Department 3 (Sanitation dept.) 17% Department 1 (A/C dept.) 40% Saving Average: The test showed an average of 40% saving in the working hours of the compressors comparing to A/C units without TLC installed

Air Condition units (window, top, split, mini-central) Total labor hours plant 2400 Total working hours for 1 A/C (60% of the time)1440 Average energy consumption of A/C2.5 KW KW/Hour cost (localy)13.5 cents A.C operation cost per hour2.5 * 13.5 = cents Total yearly expenses per A/C without TLC1440 (hours) * cents = 486 US$ Total savings per A/C per year (30% calculation) is US$ Savings calculations

Total savings for one A/C unit (yearly)145 US$ Investments costs (TLC + installation)100 US$ Return of investment within 8 months (100/145 = 0.68) A/C units in plant7000 Summary Total yearly savings 7000 * 145 US$ = US$

Adding TLC in all 7000 plants A/C units Will save 1 Million US$ On yearly electricity bills - Which are 5% of the total Electricity bills of the plant Conclusion