Two Dimensional Fast Service Imaging Adam Silva. Intro Handheld devices are currently being manufactured and developed for medical imaging. These devices.

Slides:



Advertisements
Similar presentations
devices... Inputs and Output Keyboard The commonest way to enter data into a computer. Each key is simply a switch, which when pressed, results in a.
Advertisements

Spectroscopic Ellipsometry University of Texas at El Paso Lynn Santiago Dr. Elizabeth Gardner Chem 5369.
Future Of Diagnostic Imaging A Look Into The Next Decade ? (Part 1)
Light and Optics 4.1 Mirrors form images by reflecting light. 4.2
Optical/Laser/Vision Measurement
Chapter 3 Notes Section 1-3.
Computer Vision REU Week 2 Adam Kavanaugh. Video Canny Put canny into a loop in order to process multiple frames of a video sequence Put canny into a.
Drexel University Optical Imaging Research Group
How you See The eye & vision. How You See The eye collects light from objects and projects them on the light-sensitive portion of the eye, the retina.
Fluorescence Diffuse Optical Tomography (FDOT) Our group presented three-dimensional (3D) in vivo images of human breast cancer based on fluorescence diffuse.
Smart Traveller with Visual Translator for OCR and Face Recognition LYU0203 FYP.
Input and Outputs Leslie Flores. What is an Input? Input consists of data and instructions. Input devices translate what people understand into a form.
Improving Uncertainties of Non-Contact Thermometry Measurements Mark Finch Fluke Calibration.
Sensors and Their Uses in Hospitals
Intermediate GNVQ ICT Input Devices and Methods Manual input devices are used by people to enter data by hand. Keyboard Pointing devices Joystick Digital.
Development of NIR camera for early detection of diabetic wounds V.Reukov 1, A.Shaporev 1, T.Kelechi 2, D.Kwartowitz 1, A.Vertegel 1 1 Bioengineering Department,
GCSE Information Technology Input Devices and Methods 3 Manual input devices are used by people to enter data by hand. Keyboard Pointing devices Joystick.
1 Fluorescence Cameras -Dr James Milnes -Live Cell Imaging – Stem Cell Research -Portland Place, London, 24 June 2009 Live Cell Imaging.
Nanoscale Cr 4+ – Doped Olivine Crystallites in Glass-Ceramics for NIR Optical Amplifiers and Lasers By: Fayette Colon Mentor: Mikhail Sharonov Assistant.
Muhammad Tehseen Qureshi.  What is input?  Input device is any hardware component that allows users to enter data and instructions  Data or instructions.
Scanning Probe Microscopy (SPM) Real-Space Surface Microscopic Methods.
GCSE Information Technology Input Devices and Methods Objectives:  To understand what input devices are.  Identify their individual uses  Be able to.
INPUT DEVICES. KEYBOARD Most common input device for a computer.
GCSE Information Technology Computer Systems. GCSE Information Technology The three stages of computing are input, processing and output. A computer works.
Fluorescent Multi-Layer Disc
Peripherals = ) By Rhiannon
Image Processing1 Image Acquisition Photo sensors –Photo diodes and photo diode array –Photo transistor Video camera.
Creating With Code.
NURIZAH RAMLI 10D0124 DTE. Any data or instruction entered into the computer is known as INPUT. An input device helps you to communicate with the computer.
Nanonics MultiView 2000™ Product Presentation. MultiView 2000 ™ Complete System MultiView 2000™ Product Presentation.
Introduction EE 520: Image Analysis & Computer Vision.
 a mathematical procedure developed by a French mathematician by the name of Fourier  converts complex waveforms into a combination of sine waves, which.
Detectors and Cross Talk Presented below are cross talk measurements carried out on 2 Burle and 1 Hamamatsu MCP PMTs and 1 Hamamatsu MultiAnode PMT (MAPMT).
Lesson 12 November 29 th,  Telescope - an optical device that provides enlarged images of distant objects.  Dutch spectacle-maker Hans Lippershey.
Laser-Based Finger Tracking System Suitable for MOEMS Integration Stéphane Perrin, Alvaro Cassinelli and Masatoshi Ishikawa Ishikawa Hashimoto Laboratory.
Audio Visual Vocab 9 Decibel, LCD, Lens, Pixel, Megapixel,
Introduction to Optics. How do we see things? What is light?
Laser Impressions, Inc. Applications of laser engraving Company Profile Laser Impressions, Inc. LINK: Alderwood Ave. Sunnyvale, CA.
Collecting.  What are some Tools for Information Processes?  Collecting is the information process that involves deciding what to collect, locating.
MultiView 1000™ Product Presentation Nanonics MultiView 1000™
INTRODUCTION TO COMPUTER CHAPTER N0 2 INPUT & INPUT & OUTPUT DEVICES OUTPUT DEVICES INSTRUCTOR: ADEEL ANJUM ADEEL ANJUM.
Electron Microscope. How do they work Instead of using light they fire a beam of electrons (which have a wavelength less than 1nm compared to light which.
Light , Arsenie. Light travels almost unimaginably fast and far. Light carries energy and information. Light travels in straight lines. Light bounces.
Face Detection M 方科植. Method To detect front face, a face sketch is fetched and used to determine the real front face, and the sketch is processed.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
VIRTUAL KEYBOARD By Parthipan.L Roll. No: 36 1 PONDICHERRY ENGINEERING COLLEGE, PUDUCHERRY.
What kind of light is emitted by regular (not self-luminous) objects?
  Computer vision is a field that includes methods for acquiring,prcessing, analyzing, and understanding images and, in general, high-dimensional data.
Quantification of Sensory Abnormalities Client: Dr. Miroslav Backonja Advisor: Prof. Mitchell Tyler Group Members (in order of appearance): Colleen Farrell.
Based on an Article Published 12/2011 by: En Hong, Honogwei Zhang, Reuven Katz, John S.Agapiou Presented by: Vadim Tutaev & Boris Sheendlin.
MODERN FLUID FLOW MEASURING INSTRUMENT
History of digital radiology 1980 Kinos L.T. ET all developed a portable radiographic X-ray camera made of tantalum and aluminum. Digital radiography.
Dummy PCB Glass/Optical Single crystal planar Diamond detector.
Sight Our Visual Perception
Lesson 4 Alternative Methods Of Input.
A device tat transfers data from the outside world into a computer
Engineering Metrology and Instrumentation
E- source R&D update ILC source laser project Faraday rotation experiment A. Brachmann 05/07/07 SLAC R&D meeting.
Non-invasive cardiac pulse measurement
Scintillation Material Encapsulation Fixture
Technologies That Use Light
Bashar Mu’ala Ahmad Khader
3D Printing ..
Chapter 5 - Input.
Lesson 4 Alternative Methods Of Input.
Section 4: Using Light Light can be used to form three-dimensional images and to transmit information in optical fibers. K What I Know W What I Want to.
سرطان الثدي Breast Cancer
Mask fit process. Mask fit process. The mask fit process begins with 3-dimensional surface images of the subject's face (A). Three-dimensional scans are.
Team 9 Our completed project will have the following:
Chapter 14: Light Section 4: Using Light
Presentation transcript:

Two Dimensional Fast Service Imaging Adam Silva

Intro Handheld devices are currently being manufactured and developed for medical imaging. These devices allow for a quicker turn around on results. One major use for these is for detecting breast cancer.

Current Devices The main problem with current handheld devices is that they use flat faced probes. The new device being developed is able to fit to the shape of what it is imaging.

The Device The imaging device consists of a 785 nm, 500mW laser diode source and an intensified charge-coupled device camera detector.

The Device The handheld probe consists of 6 points of illumination and 165 points of collection of optical signals. The visual data was first obtained by the ICCD camera and then passed through a Matlab code to get a final 2-D contour image. The whole process results in a 2 second delay.

Study The first study used the device with a flat faced probe. The second study used the device with a curvature in the probe to fit the shape of the breast. The third study tested the ability to detect more than one mass in the breast.

Results The results of these studies showed that the device did indeed function as intended. This is important because the almost real time of the device allows for instant image access when used in hospitals.

Source Erickson, Sarah, Jiajia Ge, and Andrea Sanchez. Two Dimensional Fast Surface Imaging Using a Handheld Optical Device. Neoplasia Press Inc., 2009.