Column Chromatography. Types of columns: 1- Gravity Columns: The mobile phase move through the stationary phase by gravity force. 2- Flash Columns (Air.

Slides:



Advertisements
Similar presentations
Introduction to Chromatography
Advertisements

In this presentation you will:
Gas Chromatography There an be many parts to a gas chromatography system but the basic components include: An injection system. A column (controllable.
KROMATOGRAFİ Sedat Türe. HPLC Liquid Chromatography.
Introduction to Chromatographic Separations Due to lack of analytical specificity, separations are often necessary Chromatography is about separations.
Paper and Thin layer Chromatography
COLUMN CHROMATOGRAPHY. COLUMN CHROMATOGRAPHY INTRODUCTION OF CHROMATOGRAPHY.
Chromatography Dr.Tawfeq A. Al-Howiriny Associate Professor
PARTITION CHROMATOGRAPHY
Chapter 6 - Chromatography
Experiment.13 Amino acid analysis by adsorption thin layer chromatography (adsorption TLC)
Chromatography Chromatographic separation is based on distribution of separated compound (analyte) between mobile phase and stationary phase Richard Vytášek.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Chromatography Separates components in mixture: Based on - polarity
Chromatography Tomáš Mlčoch Pavel Moťka. Chromatography Described by Tswett in 1906 Described by Tswett in 1906 He separated some pigments using a tube.
Chromatography Chapter 6.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
By: Thilag.k & Stephen. What is Hpcl??? Hplc or high performance liquid chromatography is the most widely used analytical separation technique. The difference.
1. Fast Protein Liquid Chromatography 2 FPLC A semi-automatic microprocessor controlled machine used primarily for the separation of macromolecules A.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Lecture I. 1- Chromatographic methods A. Braithwait, E.J. Smith (1995) 2- Modern thin layer chromatography (chromatographic science services vol, 52)
INTRODUCTION TO CHROMATOGRAPY
CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient.
COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5.
COLUMN CHROMATOGRAPHY
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC). HIGH PERFORMANCE LIQUID CHROMATOGRAPHY High Performance Liquid Chromatography (HPLC) is one of the most.
Partition chromatography Partition chromatography is carried out on sheets of filter paper, column or thin layer of powdered cellulose, moist silica gel.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
Best Broken into four categories
HPLC.
Chapter 28 High Performance Liquid Chromatography.
Separation Techniques
Adsorption Chromatography 1Dr. Nikhat Siddiqi. Adsorption chromatography refers to the use of a stationary phase or support such an ion-exchange resin,
HPLC.
PURIFCATION OF ORGANIC COMPOUNDS
CHROMATOGRAPHY. Chromatography Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient of sample.
T.A Nouf Alshareef KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
Principles of chromatography
COLUMN CHROMATOGRAPHY
Downloaded from کروماتوگرافی CHROMATOGRAPHY Downloaded from
Column Chromatography
Chromatography.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Biochemical instrumental analysis - 9 Dr. Maha Al-Sedik 2016 CLS 332.
CHROMATOGRAPHY.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Lecture – 1 GEB 308 Summer 2016.
COLUMN CHROMATOGRAPHY
LU 3: Separation Technique (P2)
Chromatography- TLC & HPLC
CHROMATOGRAPHY.
Crystallization & Filtration
HPLC.
High Performance Liquid Chromatography (HPLC)
Chromatographic separation
SEPARATION TECHNIQUES
HPLC.
Chapter: Chromatography
SEPARATION OF MIXTURE BY USING COLUMN CHROMATOGRAPHY
Principle of separation of different components:
Chapter: Chromatography
High-Performance Liquid Chromatography
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
CHROMATOGRAPHY.
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
High-Performance Liquid Chromatography
Presentation transcript:

Column Chromatography

Types of columns: 1- Gravity Columns: The mobile phase move through the stationary phase by gravity force. 2- Flash Columns (Air or nitrogen pressure): The mobile phase is pushed by stream of air or nitrogen using special using special values (Adaptors).

3-Low and Medium Pressure Columns (pumped): The movement of mobile phase is accelerated by using pumps that generate low or medium pressure. The increase in the flow rate shorten the time of separation.

4-Vacuum Columns [Vacuum liquid chromatography (VLC)]: The adsorbent is applied dry into a sintered glass funnel. The sample is applied by dry method or as solution. Then the mobile phase is added portion by portion and vacuum is applied after each portion to collect each fraction.

5- High pressure Columns (HPLC): In this columns we use very fine silica gel so great increaser in separation power. However, the flow rate of the mobile phase is severely decreased. High pressure pumps are used to push the solvent through the column which in this case must be made of stainless steel.

Backing of Columns: The adsorbent is applied to the Column in two ways: Slurry packing (Wet method): Slurry packing (Wet method): The adsorbent is suspended in the mobile phase and stirred very well to drive off all air bubbles. The resulted slurry is then poured into the column. At the tap end of the column a piece of glass wool or cotton must be added before the slurry application. Sand may be added after the slurry. After slurry application the column must be allowed to settle overnight. In gel chromatography the adsorbent must be soaked in the mobile phase overnight to absorb the mobile phase and swell. In gel chromatography the adsorbent must be soaked in the mobile phase overnight to absorb the mobile phase and swell.

2- Dry Packing: 2- Dry Packing: In this method the dry adsorbent is poured to the column directly. Vibration is the applied to get rid of air bubbles then the mobile phase as passed through the adsorbent. This method can not be applied gel Chromatography.

Mobile phase: Mobile phase: It is a mixture of organic solvents (unusually one solvent only) the choice of the column mobile phase is achieved after TLC study in different solvent systems. Good solvent system must produce R f value less than 0.6 for all materials to be separated by the column. If the system moves them more and produces higher R f no separation will occur. Systems that do not move spots at all on TLC are not good for column separation.

Isocratic system: Isocratic system: Means using the same mobile phase from the beginning to the end of the separation. Gradient: Gradient: The polarity of the system increased gradually during separation by increasing the proportion of the more polar solvent. A typical gradient may be start with CHCl 3, followed by CHCl 3 /MeOH mixtures with gradual increase in % of MeOH till all spots are eluted from the system.

Monitoring the column: Usually fractions of certain volume are collected evaporated to small volume and spotted on TLC. Similar fractions are collected together for more purification or crystallization. Usually fractions of certain volume are collected evaporated to small volume and spotted on TLC. Similar fractions are collected together for more purification or crystallization. In bioassay guided fraction the fractions are monitored by the bioassay then by TLC. In bioassay guided fraction the fractions are monitored by the bioassay then by TLC.

Monitoring the column: Usually fractions of certain volume are collected evaporated to small volume and spotted on TLC. Similar fractions are collected together for more purification or crystallization. Usually fractions of certain volume are collected evaporated to small volume and spotted on TLC. Similar fractions are collected together for more purification or crystallization. In bioassay guided fraction the fractions are monitored by the bioassay then by TLC. In bioassay guided fraction the fractions are monitored by the bioassay then by TLC.

Sample Application 1- Wet application: Dissolve the sample in the initial mobile phase and apply by pipette to the top of the column. This is very good method but in most of cases the samples are not soluble in the initial mobile phase. 1- Wet application: Dissolve the sample in the initial mobile phase and apply by pipette to the top of the column. This is very good method but in most of cases the samples are not soluble in the initial mobile phase. 2- Dry loading: Dissolve sample in any volatile solvent. The sample solution is then adsorbed on small weight of adsorbent and the solvent is allowed to evaporate. The dry adsorbent loaded with the sample is then applied to the column. 2- Dry loading: Dissolve sample in any volatile solvent. The sample solution is then adsorbed on small weight of adsorbent and the solvent is allowed to evaporate. The dry adsorbent loaded with the sample is then applied to the column.

Theoretical cencopts 1- Differential migration: Different compounds move through the system with different rates of movement this is called "differential migration". The speed of any compound in the mixture is determined by the number of molecules of that compound in the mobile phase.

Suppose we have mixture of materials “A” and “B”: A: Have more affinity to mobile phase ei large number of molecules are present in the mobile phase. B: Have more affinity to stationary phase ei small number of molecules are present in the mobile phase.

Mathematical prsentation of differential migration: U: velocity of solvent (mobile phase). U: velocity of solvent (mobile phase). Ux: velocity of material X. Ux: velocity of material X. R: fraction of material X in the mobile phase. R: fraction of material X in the mobile phase. Ux = UR

If R = I ie all the compound molecules are present in the mobile phase. If R = I ie all the compound molecules are present in the mobile phase. Ux = U X I Ux = u Ux = u :. Matenial X will move with the solvent velocity. if R = 0.0 ie all the compound molecules are present in the stationary phase. if R = 0.0 ie all the compound molecules are present in the stationary phase. Ux = u x 0.0 :. Ux = 0.0 :. Ux = 0.0 :.Material X will not move at all. For any material to be separated through the system it must be distributed between the mobile phase and stationary phase.

Capacity Factor: The factor that control the distribution of any material between the two competitive phases is called “Distribution coefficient” or “Capacity factor” or “Mass distribution ratio” K’ The factor that control the distribution of any material between the two competitive phases is called “Distribution coefficient” or “Capacity factor” or “Mass distribution ratio” K’ (n)s (n)s K’ = (n)m (n)m (n)s : Is the total number of moles of the compound in the stationary phase. (n)m : Is the total number of moles of the compound in the mobile phase.

t r – t 0 t r – t 0 K’ = K’ = t 0 t 0 t r : Time required for the sample to cross the column (retention time). t 0 : Time required for the solvent molecules to cross the column. Bigger K’ means that the material retained more time on the column ei move slowly. Smaller K’ means faster movement. Bigger K’ means that the material retained more time on the column ei move slowly. Smaller K’ means faster movement.

2- Movement of materials through the chromatographic system in the form of “zones” or “bands”: It was assumed that the chromatographic system composed of number of “distribution systems” or “equilibrations” called “Theoretical Plates”. Each theoretical plat is composed of stationary phase and mobile phase. The height of each plate is called “Height equivalent to Theoretical Plate” (HETP). It was assumed that the chromatographic system composed of number of “distribution systems” or “equilibrations” called “Theoretical Plates”. Each theoretical plat is composed of stationary phase and mobile phase. The height of each plate is called “Height equivalent to Theoretical Plate” (HETP). The number of theoretical plates “N” is important for separation. Increasing “N” resulted in narrower bands and better separation. The number of theoretical plates “N” is important for separation. Increasing “N” resulted in narrower bands and better separation.

L L N = N = HETP HETP L: Column length “N” can be increased by: 1- Increase the length of the column (impractical). 2- Decrease the HETP. How to decrease HETP:  Decrease the particle size of the stationary phase.  Proper selection of good mobile phase.

Materials move through the column as bands or zones and velocity is controlled by K'. Material with K' = 1 (64 molecules) The material will be present in the middle of the system in the form of band. If we increase “N” the material will from narrower. Narrow bands allow better separation of mixtures.

Factors affecting separation:

Factors due to Stationary Phase: 1- Particle size of the stationary phase: Reducing the particle size increases the surface area and improve separation. However, reduction of the particle size will decrease the flow rate of the mobile phase. In HPLC we use very fine particles to get very good separation. The flow rate problem is solved by the use high pressure pumps to push the mobile phase through the stationary phase. Columns are made of stainless steel to withstand the high pressure. In HPLC we use very fine particles to get very good separation. The flow rate problem is solved by the use high pressure pumps to push the mobile phase through the stationary phase. Columns are made of stainless steel to withstand the high pressure.

2- Adsorbent activity: The choice of the suitable adsorbent is very important. 3- Uniformity if packing of the column: If the stationary phase is not packed uniformly then the bands will be irregular and less uniform resulting in poor separation. 4- Concentration of the mixture: the proper ratio between sample to be separated and the amount of stationary phase is very important too much samples resulted in bad separation.

Factors due to Mobile Phase: 1- Selection of the proper mobile phase: Very polar mobile phase will wash out all components without any separation. On the other hand very non polar mobile phase will result in broad band and poor separation. 2- Rate of flow: Slower flow rate usually resulted in a better separation and narrower bands. 3- Consistency of flow: The continuous flow of the mobile phase during the whole experiment gives better separation than interrupting the flow then continue it later.

Factors due to Columns: Column dimensions: Increasing the length of the column improve separation. However, that usually leads to slower flow rate. Also increasing the column length some times is impractical. Column dimensions: Increasing the length of the column improve separation. However, that usually leads to slower flow rate. Also increasing the column length some times is impractical. Column temperature: Increasing the temperature usually reduces the adsorption power of the stationary phase and increase elution speed. This may leads to decrease in the efficiency separation. Column temperature: Increasing the temperature usually reduces the adsorption power of the stationary phase and increase elution speed. This may leads to decrease in the efficiency separation.