13.02.2008 Warsaw University LiCAS Linear Collider Alignment & Survey IWAA08, G. Moss 1 The LiCAS LSM System First measurements from the Laser Straightness.

Slides:



Advertisements
Similar presentations
Running a model's adjoint to obtain derivatives, while more efficient and accurate than other methods, such as the finite difference method, is a computationally.
Advertisements

Frequency Scanning Interferometry (FSI) measurements
Stephen Gibson, ATLAS Offline Alignment, 2 nd July Incorporating FSI with the Offline Alignment Overview ATLAS Group, University of Oxford Stephen.
S. M. Gibson, IWAA7 November ATLAS Group, University of Oxford, UK S. M. Gibson, P. A. Coe, A. Mitra, D. F. Howell, R. B. Nickerson Geodetic Grids.
1 Extreme Ultraviolet Polarimetry Utilizing Laser-Generated High- Order Harmonics N. Brimhall, M. Turner, N. Herrick, D. Allred, R. S. Turley, M. Ware,
The LiCAS FSI Subsystem Current Status and Initial Measurements John Dale for the LiCAS Collaboration IOP HEP April 2008.
LHC Collimator Survey Train Concept / Development / Status Patrick Bestmann CERN BE/ABP/SU IWAA /09/2010 Remote Controlled Measurements in the LHC.
The Linear Collider Alignment and Survey (LiCAS) Project Richard Bingham*, Edward Botcherby*, Paul Coe*, Grzegorz Grzelak*, Ankush Mitra*, Johannes Prenting.
MSU CSE 240 Fall 2003 Stockman CV: 3D to 2D mathematics Perspective transformation; camera calibration; stereo computation; and more.
Initial Calibration and Stability Results from the LiCAS RTRS FSI System John Dale for the LiCAS Collaboration IWAA February 2008.
1 Reconstruction and statistical modelling of geometric measurements from the LiCAS project Patrick Brockill LiCAS Group Oxford, 6 February, 2008 Talk.
Use of a commercial laser tracker for optical alignment James H. Burge, Peng Su, Chunyu Zhao, Tom Zobrist College of Optical Sciences Steward Observatory.
Sta bilization of the F inal F ocus : Stabilization with Nano-Meter Precision.
Introduction to experimental errors
Tracking using the Kalman Filter. Point Tracking Estimate the location of a given point along a sequence of images. (x 0,y 0 ) (x n,y n )
“Pinhole Measurement” Approach to K Measurements using Spontaneous Radiation November 14, 2005 J. Welch, R. Bionta, S. Reiche.
StaFF: Motion Stabilization with Nano-Meter Precision Proposed experiment conducted within framework of StaFF (Stabilization of Final Focus for ILC). Funded.
S. M. Gibson, P. A. Coe, Photon02, 5 th September Coordinate Measurement in 2-D and 3-D Geometries using FSI Overview ATLAS Group, University of.
LiCAS train simulations (current status of work done at Oxford) Grzegorz Grzelak.
The Calibration Process
1 ILC Main Linac Alignment Simulations using Conventional Techniques and Development of Alignment Model John Dale LCWS08 & ILC08.
Slides 13b: Time-Series Models; Measuring Forecast Error
Searching for Quantum LOVE at the Australian Synchrotron Light Source Eugene Tan On behalf of Rohan Dowd 120/10/2010Eugene Tan – IWLC 2010, Genega ASLS.
Performance Analysis of an Optoelectronic Localization System for Monitoring Brain Lesioning with Proton Beams Fadi Shihadeh (1), Reinhard Schulte (2),
Offline Data Analysis Software Steve Snow, Paul S Miyagawa (University of Manchester) John Hart (Rutherford Appleton Laboratory) Objectives + requirements.
Ultra-Low Emittance Storage Ring David L. Rubin December 22, 2011.
Universität Hannover Institut für Photogrammetrie und GeoInformation Issues and Method for In-Flight and On-Orbit Calibration (only geometry) Karsten Jacobsen.
David Urner, Oxford University, RHUL – June StaFF Stabilization of Final Focus Motion Stabilization with Nano-Meter Precision David Urner Paul Coe.
LECTURER PROF.Dr. DEMIR BAYKA AUTOMOTIVE ENGINEERING LABORATORY I.
DESY, Sep. 27, 2005 Warsaw University LiCAS Linear Collider Alignment & Survey A. Reichold, Oxford for the LiCAS collaboration 1 Survey and Alignment.
Freiburg 7/07/20001 laser beam lens CCD (long arm) screen + grid CCD (short arm) glass plates at  45° STAMP : Saclay Telescope for the Alignment of Many.
Peter J. LaPuma1 © 1998 BRUKER AXS, Inc. All Rights Reserved This is powder diffraction!
Goal : Setup and monitor “chambers” with resolution of < 200  m Demonstrate System Redundancy Test Setup : 1 SLM Line 1 Transfer Line 1 Transfer Plate.
Goal : Setup and monitor “chambers” with resolution of  < 200  m Demonstrate System Redundancy Test Setup : 1 SLM Line (2 Laser Redundancy) 1 Transfer.
How Errors Propagate Error in a Series Errors in a Sum Error in Redundant Measurement.
RUDE Vivien With the help of Hélène MAINAUD-DURAND And Mateusz SOSIN BE/ABP/SU CLIC MODULE September 19, 2011 Présentation REPORT OF THE CURRENT TESTS.
Overview: Primary Sensitivities Nov S. Childress Page 1 NuMI Overview: NuMI Primary Beamline Sensitivities NuMI requirements are for a very large.
Welcome to MONALISA A brief introduction. Who we are... David Urner Paul Coe Matthew Warden Armin Reichold Electronics support from CEG Central Electronics.
1 Internal Alignment of VXD3 Overview VXD3 at SLD Observing misalignments with the track data Matrix technique to unfold alignment corrections Comments.
Short range alignment strategy in CLEX and first results CLIC Workshop January 2015 on behalf of : Hélène Mainaud-Durand, Mateusz Sosin Mathieu.
1 A first look at the KEK tracker data with G4MICE Malcolm Ellis 2 nd December 2005.
The stabilisation of the final focus (StaFF) system Sun 12 th March 2006 MDI – LCWS06 at I I Sc Bangalore David Urner, Paul Coe, Armin Reichold.
Kaori Maeshima (FNAL), Alignment Workshop at CERN: May 17-18, Endcap Alignment Status of Offline Software Alignment CERN 17, 18 May 2001.
ILC Main Linac Alignment Simulations John Dale 2009 Linear Collider Workshop of the Americas.
Marian Ivanov TPC ExB and V drift calibration and alignment.
CLIC Beam Physics Working Group CLIC pre-alignment simulations Thomas Touzé BE/ABP-SU Update on the simulations of the CLIC pre-alignment.
WP3 The LiCAS Laser Straightness Monitor (LSM) Greg Moss.
Physics 2.1 AS Credits Carry out a practical physics investigation that leads to a non- linear mathematical relationship.
Measurements Measurements and errors : - Here, the goal is to have some understanding of the operation and behavior of electrical test instruments. Also,
MONALISA Update David Urner ATF2 Meeting Dec
ATF2 beam operation status Toshiyuki OKUGI, KEK The 9 th TB&SGC meeting KEK, 3-gokan Seminar Hall 2009/ 12/ 16.
Contents: 1. Introduction 2. Gyroscope specifications 3. Drift rate compensation 4. Orientation error correction 5. Results 6. Gyroscope and odometers.
Calibration of energies at the photon collider Valery Telnov Budker INP, Novosibirsk TILC09, Tsukuba April 18, 2009.
LiCAS Simulation Based on: Simulation of the LiCAS survey system for the ILC by G. Grzelak¤, A. Reichold+, J. Dale+, M. Dawson+, J. Green+, Y. Han+, M.
1 Research on laser tracker measurement accuracy and data processing Liang Jing IHEP,CHINA
Chem. 31 – 6/13 Lecture. Announcements I Pipet and Buret Calibration Lab Report Due Quiz and Homework Returned in Lab Exam 1 on Thursday –Will cover material.
Laser beam trajectory measurement with a CCD camera Georg Gassner.
WP3 Frequency Scanning Interferometry Analysis Techniques for the LiCAS RTRS John Dale.
M. Kuhn, P. Hopchev, M. Ferro-Luzzi
A simple model of the ILC alignment process for use in LET simulations
Test and Measurement Conference Evaluation of machines and CMMs using a laser tracer 1 August 2017 Kenneth Manana TQM
First Data from the Linear Collider Alignment and Survey Project (LiCAS) The ILC requires unprecedented accuracy, speed and cost efficiency for the survey.
The Calibration Process
Status of Transfer Line Reconstruction University of Wisconsin-Madison
ILC Main Linac Alignment Simulations
Beam-Based Alignment Results
Noah Snavely.
Measurements Measurements and errors :
Fitting to the Linear Region of I’/q
Lecture 15: Structure from motion
Presentation transcript:

Warsaw University LiCAS Linear Collider Alignment & Survey IWAA08, G. Moss 1 The LiCAS LSM System First measurements from the Laser Straightness Monitor of the LiCAS Rapid Tunnel Reference Surveyor.

IWAA08, G. Moss 2 Contents LiCAS Overview Straightness Monitor Basics Produced system Beam Fitting Stability The Ray tracer Reconstruction Calibration Autocalibration Conclusions

IWAA08, G. Moss 3 The RTRS

IWAA08, G. Moss 4 Sensitivity of Internal Components ComponentTrXTrYTrZRotXRotYRotZ LSM√√√√ FSI±±√±± Inclinometer √ (not used) √

IWAA08, G. Moss 5 Straightness Monitor Basics LSM is used to measure: - Transverse translations - Rotations Require 1µm precision over length of train z y Translation: Spots move same direction Rotation: Spots move opposite directions CCD Camera Retro reflector Incoming beam Outgoing beam The train needs to know how it is aligned internally. Achieved by internal FSI and the Laser Straightness Monitor.

IWAA08, G. Moss 6 Produced System CCDs Laser beam Pellicles

IWAA08, G. Moss 7 Beam Fitting Multiple beams fitted on each image (to deal with reflections) Typical difficult image Differences from data and fit (range of 2/256)

IWAA08, G. Moss 8 Beam Fitting Real life beams fitted over 40 hours to: 1.28μm horizontally 0.54μm vertically Difference not understood – possibly beam jitter

IWAA08, G. Moss 9 Stability Large amount of data taken with no planned movement 2 x 10 images every 10 minutes Data taken for 4 days

IWAA08, G. Moss 10 Stability An example camera: Car 2 Camera 0 beam Y position

IWAA08, G. Moss 11 Stability Laser power increased here 0.78μm Standard deviation 0.55μm Standard deviation per camera. (Same as earlier) Camera 2 Camera 0 + Camera 2 Camera 0 + Camera 2 added

IWAA08, G. Moss 12 Stability Launch/car1 are unstable to the order of 4 micro-radians over 4 days. Motion of ~35μm on car3 (9.2m away) Motion of ~15μm on car2 (4.7m away) Motion of ~1μm on car1 (0.2m away & attached)

IWAA08, G. Moss 13 The LSM CCDs Laser beam Pellicles

IWAA08, G. Moss 14 Ray Tracer Ray tracer used to calculate spot positions Highly flexible Agrees with completely independent Simulgeo simulation

IWAA08, G. Moss 15 Reconstruction Ray tracer is used as a part of a fit function for the Minuit fitting package Position & orientation of each LSM unit used as the fit parameters CCD spots fitted by Chi-squared Minimisation Precise to ~0.5xSpot uncertainty for translations ~0.3 microns Precise to ~5xSpot uncertainty for rotations ~3 microradians Easy to take many images, average, then fit or fit then average.

IWAA08, G. Moss 16 Reconstruction

IWAA08, G. Moss 17 Internal Geometry Model used needs correct geometry Camera positions & orientations Pellicle positions & orientations These are the calibration constants Measured to 5-10 microns with CMM Need to know some better

IWAA08, G. Moss 18 Constant Importance Important Constants CCD Y positions CCD Z positions Pellicle Y positions Pellicle Z positions 1 micron error in parameter gives 0.25 – 0.5 micron / 2.5 – 5.0 microradian error in reconstructed parameter

IWAA08, G. Moss 19 Classical Calibration This method compares spot positions generated using a set of calibration constants, to the measured values (knowing the correct orientation). Many orientations are used It changes the calibration constants until the difference between the measured spots is minimised. Complements linear algebra method (see presentation by A. Reichold.)

IWAA08, G. Moss 20 Classical Calibration Simulation run with typical values: 1μm camera resolution 3μm/10μradian observation error 80 orientations used 1mm component uncertainty Important constants found to < 1 μm Other constants found to <100 μm (not that useful)

IWAA08, G. Moss 21 Classical Calibration Now USE the fitted constants Reconstruct many times and compare to the truth Mean residual gives systematic error of that system Standard Deviation is dominated by camera resolution – gives statistical error of that system Offset: 0.18μm Offset: 0.69μ radians Offset: -0.36μm Offset: 2.80μ radians Example run shown on right. However – this is only one example. Would like to know what to expect in general.

IWAA08, G. Moss 22 Classical Calibration Run simulation many times (with 0.1 mm component uncertainty) Collect the mean and standard deviation values of the histograms produced Create a histogram of these values For the mean histogram the standard deviation gives the accuracy For the standard deviation histogram the mean gives the precision

IWAA08, G. Moss 23 Classical Calibration Accuracy: 0.3 μm Precision: 0.5 μm

IWAA08, G. Moss 24 Classical Calibration Precision: 2.6 μradians Accuracy: 1.2 μradians

IWAA08, G. Moss 25 Auto-Calibration E = External unknowns (reconstructed variables) I = Internal unknowns (calibration constants) M = Measurements M = F(E,I) Eg for a single LSM reading 8 measurements (CCD spot positions) 4 external unknowns 18 internal constant unknowns (this is underconstrained) For 10 readings 80 measurements 40 external unknowns 18 internal constant unknowns (This is overconstrained by 22 DoF) We use the large overconstraint found with many readings to determine the calibration constants. Complements both classical calibration methods Can be used with much more data and can show how constants change.

IWAA08, G. Moss 26 Auto-Calibration This method incorporates the calibration constants as part of the fitting process Many runs are fitted en- masse and the individual chi-squareds summed The constants that give the lowest total chi- squared are chosen.

IWAA08, G. Moss 27 Auto-Calibration Simulations have been performed using typical uncertainties 40 runs 1μm camera resolution 0.1mm constant uncertainty Find most important constants to <0.3μm (after corrections) Problems (as expected) with scaling & offsets Still a useful addition to calibration

IWAA08, G. Moss 28 Conclusions Working LSM system Beam fitting now mature Stability under investigation Ray tracer well developed Reconstruction effective Calibration predicted to work well Autocalibration predicted to compliment well