SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home ENK6-CT1999-00019.

Slides:



Advertisements
Similar presentations
Common Terminology Emittance Winter U-Factor or U-Value R-Value
Advertisements

Solar House Project APES 2014.
PASSIVE ARCHITECTURAL COOLING FOR THREE STOREY OFFICE BUILDING DESIGN CONCEPT RTU Working group: KRISTAPS SAFRANOVS, JURIS SOROKINS, NATALY KUZNECOVA,
The Three Tiered Philosophy
Adam Joseph Lewis Center for Environmental Studies Agents of Change Radiant Intervention.
The Portland Street Building Back to “Select a building” Back to “Select a building” NatVent Presentation of the building Presentation of the building.
Direct solar radiation is both a powerful environmental stress & renewable energy resource. The sun’s energy is most concentrated on the roof (spring through.
Chapter 5: Designing for Heating and Cooling 5.1 Organizing the problem a) Fenestration How much is optimum for the building? What should the form of the.
Passive House Seminar for Professionals from the Building Sector.
SOLVENT Development of a ventilated solar-screen glazing system consortium concept objectives glass properties glass selection overview problem tool energy.
BRE Energy Efficient Office of the Future
Energy Efficient Glass Façade for building envelope Sri Ram.N – IGBC AP; GRIHA Trainer Saint Gobain Glass India 15 th June 2011.
Conduction Cooling Loads
Requirements of Sustainable Building Envelope Marco Citterio Enea – ENE SIST th June.
Tools for Integrated Design ID seminar October Christian Hviid Industrial PhD-student Birch & Krogboe.
SOLAR THERMAL TECHNOLOGIES. Buildings contribute highly to CO2 production Big Differences between countries as a function of climate and living standards.
Energy Environment & Sustainable Development Thematic Network on Energy in the Built Environment PROJECT SUMMARY DESIGN STUDY and EXPERIMENTAL EVALUATION.
Performance-based demands ID seminar October Steffen Petersen PhD-student BYG.DTU and Birch & Krogboe.
Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH 7 September 2001, Malmo Ken-ichi Kimura Professor, Advanced.
Energy Environment & Sustainable Development Thematic Network on Energy in the Built Environment Thematic group 5 : Building Components (including windows.
Introduction to Integrated Design of Low-Energy Buildings Professor Svend Svendsen Department of Civil Engineering Technical University of Denmark
Human factor. Five sence [ Natural factor ] Mouse Eye Noise Ear Skin _Mouse,Eye,Ear,Noise,Skin Active factor.
Tinted Windows By Mark Thompson, Owen Carlson, Spencer Smith.
HEATING, VENTILATION AND AIR-CONDITIONING Prof. dr Maja Todorović University of Belgrade, Faculty of Mechanical Engineering.
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
Windows. Huge variety of available building components and several important roles Thermally most important they admit solar radiation Advantageous in.
Glass technologies to improve sustainable performance
WHAT NEEDS TO BE COMMISSIONED IN ZERO ENERGY BUILDINGS 1 What needs to be Commissioned in Zero Energy Buildings? Jorge Torres Coto.
University of Palermo – Physics Education Research Group The experimental approach to the problem was very useful because it allowed us to verify the manner.
Jamil Ibrahim Establishment Building Integration Thermal Collector BITC By Engineer Khaled Jazzar WEBCO sarl June 2014.
3M Renewable Energy Division Window Films for Commercial Buildings Window films – solution to increase energy efficiency Making Windows Work for You! Agnieszka.
Solar Radiation And it’s General Applications Nitin Jayswal.
Building promoter: PROBAM nv Architect: Declercq E. The Keppekouter project Design issue Design issue Major findings Major findings Keppekouter building.
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
Objectives of NatVent This seven nation pan European project aims to reduce primary energy consumption (and consequently CO2 emissions) in office type.
ARC 810: Building Climatology Department of Architecture, Federal University of Technology, Akure, Nigeria ARC 810: Building Climatology Department of.
The Town Hall of Zevenhuizen S.H. Liem, A.H.C. van Paassen M.Verwaal, H.F. Broekhuizen Delft, April 1998 Presentation of the building Presentation of the.
The European Office Building S.H. Liem, A.H.C. van Paassen M.Verwaal, H.F. Broekhuizen Delft, April 1998 S.H. Liem, A.H.C. van Paassen M.Verwaal, H.F.
CALRES Update Phase 1 Progress Report April 22, 2009 Bruce Wilcox Phil Niles Ken Nittler.
The Renson Headquarters Renovation issue Renovation issue Major findings Major findings The RENSON- The RENSON- Headquarters More information... More information...
HEAT TRANSFER TO A SUNROOM the affect of window type on heat transfer.
The Basler building The Basler building is situated in the city centre of Basel. This 10 storey, naturally- ventilated building, was built in The.
Chapter 2 Lighting Environments Daylight Integration and Control Advantages of daylight and windows: –Psychological & biological well-being –Constant.
Sustainable Places 2015 Savona, Italy A2PBEER – Affordable and Adaptable Public Buildings through Energy Efficient Retrofitting Jose Luis Izkara Tecnalia.
1. INTRODUCTION  How to use this toolkit.  This toolkit outlines passive design practices for low-rise wood framed construction buildings in Vancouver.
Energy Design of Buildings using Thermal Mass Cement Association of Canada July 2006.
ENGR330-1 Engineering Service Projects Project: Window Technology Benefits: HEALTH: Reduced drafting and improved daylight COST: Reduce furniture fading.
GUIDE- LINES Integrated Natural Ventilation Design One of the main tasks was to identify the parameters that have the largest influence on the performance.
A New Language Shining the Light on Passive Solar Features and Retrofit Possibilities.
Some Pointers for your assignment..  Passive solar heating is defined as using solar energy incident on windows, skylights, greenhouses, clerestories,
Introduction to Energy Management. Lesson 4 Determining the Loads on the HVAC System.
EnergyPlus applied to urban climate studies
VENTILATION AND FENESTRATION
Energy efficient windows for sustainable development Copyright of Wispeco (Pty) Ltd.
Building Environmental Systems
Climate and Architecture Dr. Abdelrahman Elbakheit
WDMA Technical Conference Chicago, IL 28 June 2016
Passive Solar Design Elements
Conduction Cooling Loads
Introduction Basic Requirements for a facade:
Chapter 5B: WINDOW SHADING AND IMPROVEMENTS
Arch205 building construction Windows- glazed curtain wall, skylights
Low-Cost, High-Energy Saving Dynamic Windows
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Civil Engineering and Architecture
Begin working on the winds worksheet from the quiz day.
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Heat Loss and Gain
Presentation transcript:

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home ENK6-CT SOLVENT Evyatar Erell and Yair Etzion BUILDING ENERGY RESEARCH JOINT FP5 ENERGIE Info-day and ENERBUILD RTD PROJECT MEETING 6 & 7 September 2001 Quality Hotel Konserthuset, Malmö, Sweden

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home The SOLVENT project The project aims to complete the development of an innovative glazing system, which is based on the concept of converting short-wave solar radiation to convective heat. Development of aerodynamic, thermal and optical models Design of a suitable frame Experimental evaluation Development of a design tool and guidelines for installation The expected outcome is a tested product ready for demonstration and commercial exploitation. The SOLVENT project - aims

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home The SOLVENT consortium Ben-Gurion University of the Negev, ISRAEL Evyatar Erell and Yair Etzion AB Överums Fönsterfabrik, SWEDEN Nils Carlstrom University of Gävle, SWEDEN Mats Sandberg Asociación de Investigación y Cooperación Industrial de Andalucia, SPAIN Jose Luis Molina Instituto de Engenharia Mecanica, PORTUGAL Eduardo Maldonado Brandeburgische Technische Universitaet Cottbus, GERMANY Olaf Gutschker The SOLVENT consortium

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home 1. Direct exposure to solar radiation often results in: - visual discomfort due to glare - thermal discomfort due to high radiative load - deterioration and fading of furnishings 2.Large glazed areas are useful in winter, but may cause over-heating in summer. In climates with cool, sunny winters and warm summers, direct gain systems have several drawbacks: Problem definition

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home fixed shading devices - interfere with the view through the window; and - reduce heating efficiency in winter operable shading devices - when deployed – have same effects as fixed shading devices - when not deployed – do not address thermal and visual stress … tinted or reflective glazing may reduce glare, but also - reduce heating efficiency in winter; and - may still allow too much heat to penetrate to the interior selective glazing (angle-selective, electro-chromic) - experimental, require considerable research - when in the transmission phase – do not address thermal and visual stress … Existing solutions

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Principle of operation

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Thermal model e dz W L q1q1 q2q2 z T(z) T1T1 T2T2 T i, v ToTo

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home d – pane-to-pane distance H in – inlet height H in – outlet height H – height of glazing system Aerodynamic parameters

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Integration in ESP-r Indoor Temperature Meteorological Variables Window Geometry Surface Temperatures Heat Fluxes Iterative process for calculating the film coefficients Glass Characterization

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Cottbus PASLINK test cell with SOLVENT window

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Sde Boqer ‘white house’ SOLVENT window

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Interior (right) and exterior view of test window at Sde Boqer black globe pyranometer

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Light sensors

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Interior air Sde Boqer test window, September 1, 2001

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Interior radiation Sde Boqer test window, September 1, 2001

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Sde Boqer test window, June 16, 2001 Black globe near window

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Sde Boqer test window, September 1, 2001 Glass surface temperatures (I)

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Glass surface temperatures (II) Sde Boqer test window, September 1, 2001 Exterior surface of clear glass

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home (Sde Boqer test window, September 1, 2001) Air channel temperature

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Channel airflow and wind (Sde Boqer test window, September 1, 2001)

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Illumination (Sde Boqer, September 1, noon) exterior daylight – approx. 110,000 lux! * 3091 in reference room!

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Dissemination I - software and documentation All test data to be collated and made available on CD or by internet, in conjunction with project reports. Academic publication of aerodynamic, thermal and optical models. A module describing the window is being prepared for integration in ESP-r. Design guidelines and a computerized tool are being developed in the project, to provide architects with technical information required for glazing selection.

SOLVENT ventilated solar screen window consortium the problem solutions? principle modeling aims test data ESP-r test sites dissemination home Dissemination II - the glazing system Overums Fonsterfabrik (window manufacturer) will promote the product by: product catalogues trade fairs demonstration installation The consortium will also publicize the window through environmental publications and internet sites, such WIRE (ISES) EU web services such as ‘MARKETPLACE’