X-ray Microanalysis zThe fluorescent production of X-rays by electrons is one of the most important interactions available in the SEM because it permits.

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

Basic Electron Microscopy
NUCP 2371 Radiation Measurements II
X-ray Photoelectron Spectroscopy
Instrumental Chemistry
X-ray Detection and Analysis
X-Ray Astronomy Lab X-rays Why look for X-rays? –High temperatures –Atomic lines –Non-thermal processes X-ray detectors X-ray telescopes The Lab.
Ion Beam Analysis techniques:
Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
Geiger-Muller detector and Ionization chamber
Dispersive property of a G-M tube HV - + In the proportional region a G-M tube has dispersive properties tube voltage.
EDX-Spectra Simulation
X-ray Microanalysis An inelastic collision between a primary beam electron and an inner orbital electron results in the emission of that electron from.
PROVIDED BY EMAD BEHDAD SPECIALIZED PROTECTION AND CORROSION OF MATERIALS LECTURERS H.MONAJATI,PHD JAFARI,PHD ISLAMIC AZAD UNIVERSITY OF NAJAFABAD BARANCH.
X-radiation. X-rays are part of the electromagnetic spectrum. X-radiation (composed of X-rays) is a form of electromagnetic radiation. X- rays have a.
First of all, do you know any methods to check chemical composition? Or how you know what is what? First of all, do you know any methods to check chemical.
Spectrum Identification & Artifacts Peak Identification.
Energy Dispersive X-ray Spectrometry and X-ray Microanalysis
Electron-Specimen Interactions
Types of Radiation Interactions All or Nothing Many Small There is a finite probability per unit length that the radiation is absorbed. If not, there is.
Chemical Analysis with the SEM Qualitative analysis Quantitative analysis Mapping of locations of elements.
X Ray Flouresence Analysis (XRF). XRF X-Ray Fluorescence is used to identify and measure the concentration of elements in a sample X-Ray Fluorescence.
Lab meetings Week of 6 October
Portable X-Ray Fluorescence to Determine the Composition of Household Objects Katherine Spoth, mentor Peter Revesz August 13, 2010.
The Origins of X-Rays. The X-Ray Spectrum The X-Ray Spectrum (Changes in Voltage) The characteristic lines are a result of electrons ejecting orbital.
ED and WD X-ray Analysis
Ge 116 Module 1: Scanning Electron Microscopy
Radiation Safety level 5 Frits Pleiter 02/07/2015radiation safety - level 51.
Qualitative, quantitative analysis and “standardless” analysis NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
X-ray Photoelectron Spectroscopy —— Application in Phase-switching Device Study Xinyuan Wang A
NON DESTRUCTIVE CHEMICAL ANALYSIS
MiniSIMS Secondary Ion Mass Spectrometer Dr Clive Jones Millbrook Instruments Limited Blackburn Technology Centre, England
Radiation Sensors Zachariadou K. | TEI of Piraeus.
Corpuscular induced and X-ray or γ -ray induced fluorescence NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Is automatic Peak ID infallible: Major constituents (C > 0.1 mass fraction or 10%)? Minor (0.01 < C < 0.1 mass fraction, 1-10%)? Trace (C < 0.01 mass fraction.
30 Ge & Si Crystals Arranged in verticals stacks of 6 called “towers” Shielding composed of lead, poly, and a muon veto not described. 7.6 cm diameter.
X-ray Microanalysis zThe fluorescent production of X-rays by electrons is one of the most important interactions available in the SEM because it permits.
Photon detection Visible or near-visible wavelengths
Chemical analysis with EDX On Supra40 How to get good quality quantitative chemical analyses - Understanding the involved physical phenomena - Choice of.
Chapter 12 Atomic X-Ray Spectroscopy
Theory and Practice of Electron Microprobe Analysis Geoc 575 Nelia Dunbar Bureau Office B-101 x5783 office x5155 lab.
Scanning Electron Microscope (SEM) – Shoots a high energy beam of electrons (waves of electrons) at a target. Electron gun Focusing coil Objective lens.
EDS Energy Dispersive Spectroscopy
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
Temperature Dependence of the Crystal Properties of 18-fold Segmented HPGe Detector Allen Caldwell, Daniel Lenz, Jing Liu, Xiang Liu, Bela Majorovits,
Scanning Electron Microscope (SEM)
GERMANIUM GAMMA -RAY DETECTORS BY BAYAN YOUSEF JARADAT Phys.641 Nuclear Physics 1 First Semester 2010/2011 PROF. NIDAL ERSHAIDAT.
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
Important EDS Parameters EDAX Detector Geometry Deadtime & Time Constants.
Scanning capacitance microscopy
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
SEM Scanning Electron Microscope
e- beam 2D sample e- beam 3D
X-ray Microanalysis An inelastic collision between a primary beam electron and an inner orbital electron results in the emission of that electron from.
X-ray microanalysis in the electron microscope
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Peterson xBSM Optics, Beam Size Calibration1 xBSM Beam Size Calibration Dan Peterson CesrTA general meeting introduction to the optics.
Questions/Problems on SEM microcharacterization Explain why Field Emission Gun (FEG) SEM is preferred in SEM? How is a contrast generated in an SEM? What.
Chapter V Radiation Detectors.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
EBB 245. Materials Characterisation Lecture 3 X-ray Fluorescence Spectrometry (XRF) Dr Zainovia Lockman PPKBSM, USM (lecture presentations/notes.
Spatial Resolution and minimum detection
X-ray spectroscopy Repetition, exercises and more
Image quality and Performance Characteristics
NANO 230 Micro/NanoFabrication
Gamma-Gamma Correlations in Na-22
BESIII EMC electronics
Nanocharacterization (II)
Presentation transcript:

X-ray Microanalysis zThe fluorescent production of X-rays by electrons is one of the most important interactions available in the SEM because it permits chemical (atomic) identification and quantitative analysis to be performed zAbout 60% of all SEMs are now equipped for X-ray microanalysis

Characteristic X-rays zCharacteristic X-rays are formed by ionization of inner shell electrons. The inner shell electron is ejected and an outer shell electron replaces it. The energy difference is released as an X-ray

X-ray peaks zThe characteristic X-ray signals appear as peaks (‘lines’) superimposed on the continuum, These peaks have fixed energies

Mosley’s law zMosley showed that the wavelength of the characteristic X-rays is unique to the atom from which they come zThis is the basis of microanalysis

Mosley’s law zK-lines come from 1st shell (1s) zL-lines come from 2nd shell (2s) zM-lines come from 3rd shell (2p) zEach family of lines obeys Mosley’s law

K-lines zK-lines are the easiest to identify and highest in energy zGaussian shape  K  and K  come together as a pair

L-lines zOften occur in groups of three or four lines so shape can vary zCan overlap K-lines zImportant for analysis of elements Z>40 Silver L-line cluster

M-lines z... and N- and O - lines are very complex zNot all lines are shown on all analyzer systems so check with standards if in doubt zAvoid use if at all possible ! However at low energies they must be used. Lead and gold are best analyzed with the M lines

Fluorescent Yield zNot all ionizations produce X-rays  The fractional yield (the fluorescent yield) is called    varies rapidly with atomic number Z and is low for low Z

Measuring X-rays  Wavelength Dispersive Spectrometers measure by diffraction from a crystal. Accurate but slow and low sensitivity z Energy Dispersive Spectrometers measure photon energy. Fast, convenient, good sensitivity but has limitations in energy resolution

The Energy Dispersive Spectrometer zA solid state device - Si(Li) P-I-N diode zConverts X-ray energy to charge. The output voltage step is exactly proportional to the deposited X-ray energy zMeasures the photon in about 100microseconds so can process 1000 or more photons/second Bias Window PIN diode Capacitor C Voltage=Q/CXray generates electron/hole pairs (3.6eV / pair) Charge ~ Xray energy

The EDS detector zThe cryostat cools the pre-amp electronics and detector diode zThe window protects the detector from the SEM vacuum, BSE, and visible light zBeware of ground loops, noise (TV monitors), lights in the chamber (the ChamberScope !)

System peaks zX-rays are also produced by electrons hitting the lens, the aperture and the chamber walls. zTo keep these system peaks to an acceptable level a collimator must look at the point where the beam hits the surface. EDS sample Lens aperture Chamber wall

Detector position zThe working distance must be set to the correct value in order to maximize count rate and minimize the systems background z12 mm in the S4700

Deadtime  Processing and displaying pulse takes some finite time  zMCAs (multi-channel analyzer) only handle one pulse at a time so some pulses will be missed zThis ‘deadtime’ must be allowed for in quantitative analysis

How much deadtime? zDeadtime increases with count rate (beam current and energy) and process time (set by operator) zValues greater than 25% may allow 2 or more pulses to hit detector at same time giving ‘sum’ peak. zValues >50% waste time and may cause artifacts

Acquisition zDuring spectrum acquisition the operator has control of a variety of parameters zThe most important of these are the beam current, which controls the input count rate, and the pulse processing time zThe processing time must be set with care to achieve optimum results

Count throughput zFor spectra choose a low count rate, and a long process time to give best resolution zFor x-ray mapping choose the highest beam current and the shortest process time to give highest throughput

Resolution zThe spatial resolution and depth penetration of a microanalysis is set by beam energy and material zTypically of order of 1 micron but can be much less if E is close to E crit z Monte Carlo models are a valuable aid in understanding the lateral and depth resolution of X-ray microanalysis

Reading the spectrum zGOLDEN RULE - identify the highest energy peaks first zThen find all other family members of this peak i.e the L,M lines zThen identify the next highest energy peak

If a peak cannot be identified.. zIs it a sum peak ? (look for dominant peaks at lower energies, one half of the energy.) zIs it an escape peak ? (look for a strong peak 1.8keV higher in energy) zIs the system calibrated properly? zIs it really a peak? - is it of the right width, does it have the right shape, are there enough counts to be sure ? How would we know?

Detectable limits zFor an X-ray line to be statistically valid it must exceed the noise (randomness) in the corresponding background region of the spectrum by a suitably large factor zRule of thumb the peak should be 2 to 3 larger than the background to be considered valid 2x 5x 10x Visibility and peak height 10x 1x?

Detection limits zThis statistical limit determines the lowest concentration of an element that might be detectable (MDL - the minimum detectable limit) zFor an EDS system this is typically in the range 1-5% depending on the overall count acquired in the spectrum and on the actual elements involved

Optimizing MDL zCount for as long as possible zSince P/B (peak to background) rises with beam energy use the highest keV possible zSet process time for highest detector energy resolution zMaximize take-off angle where possible zMinimize system peaks, spurious signal

Trace detection ? zEDS is not a trace detection technique - needs a 10x improvement to achieve even parts per thousand level zBut minimum detectable mass (MDM) is very good ( to grams) for this technique zBest with inhomogeneous samples

Low Energy Microanalysis zThe reduction in interaction volume makes possible high spatial resolution microanalysis even from solid samples zLower cps and lower dead times X-ray generation in silicon at 3keV

Microanalytical Performance zK lines are better than L lines. M lines are lowest in yield zBeam energy will determine which elements can be analyzed

Elements accessible to X-ray Microanalysis at 10keV

Elements accessible to X-ray microanalysis at 5keV

Practical Problems for Low Energy EDS zAll available lines are in 0-3keV range zThere are more than 60 elemental lines between 0 and 2keV, and more than 30 between 2 and 4keV zSpectrometers with better than 30eV resolution are needed! Distribution of X-ray lines as a function of spectral energy

Microanalysis Summary zCharacteristic X-rays, Mosley’s law zFluorescent Yield zDeadtime zCount throughput zReading the spectrum zDetectable limits zMicroanalytical Performance