1 Geiger-Mueller Tube  Introduced in 1928 by Geiger and Mueller but still find application today Used in experiments that identified the He nucleus as.

Slides:



Advertisements
Similar presentations
General Characteristics of Gas Detectors
Advertisements

Radiation Detection ionization chambers (dosimeters, pulse chambers, particle track chambers) scintillation detectors semiconductor detectors photographic.
Glass Resistive plate chambers for muon Detection
Geiger Counters. Higher Voltage As the voltage increases in a gas detector the ions collected increases. The proportional region ends. –Streamer mode.
GM COUNTER.
Geiger-Muller detector and Ionization chamber
HEP Experiments Detectors and their Technologies Sascha Marc Schmeling CERN.
Experimental Particle Physics PHYS6011 Joel Goldstein, RAL 1.Introduction & Accelerators 2.Particle Interactions and Detectors (1/2) 3.Collider Experiments.
Drift velocity Adding polyatomic molecules (e.g. CH4 or CO2) to noble gases reduces electron instantaneous velocity; this cools electrons to a region where.
Radiation Detectors / Particle Detectors
Time Projection Chamber
Weekly Journal Club for Medium Energy Physics Institute of Physics, Academia Sinica Time-Of-Flight Resistive Plate Chamber Jia-Ye Chen 2011/03/07 Collaborators.
Micro MEsh GASeous Detectors (MicroMegas)
Tracking detectors/1 F.Riggi.
1 Sep. 19, 2006Changguo Lu, Princeton University Induced signal in RPC, Configuration of the double gap RPC and Grouping of the strips Changguo Lu Princeton.
GEM Detector Shoji Uno KEK. 2 Wire Chamber Detector for charged tracks Popular detector in the particle physics, like a Belle-CDC Simple structure using.
1 VCI, Werner Riegler RPCs and Wire Chambers for the LHCb Muon System  Overview  Principles  Performance Comparison: Timing, Efficiency,
Radiation Exposure, Dose and Relative Biological Effectiveness in Medicine Background Image:
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Visualizing Data from the LHC with the Atlantis Event Display Program Joshua Auriemma Advisor: Andy Haas.
Proportional Counters
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
Detectors. Measuring Ions  A beam of charged particles will ionize gas. Particle energy E Chamber area A  An applied field will cause ions and electrons.
Measurement and Detection of Ionizing Radiation
LHeC : Muon Systems L. Pontecorvo.
TRAINING COURSE ON RADIATION DOSIMETRY: Instrumentation 1 – Gas detectors / Part 1 Anthony WAKER, University of Ontario Instutute of Technology Wed. 21/11/2012,
Radiology is concerned with the application of radiation to the human body for diagnostically and therapeutically purposes. This requires an understanding.
RPC (Resistive Plate Chamber)
Photon and Energy Fluence
Type of Material: Instrumentation Review
Drift Chambers Drift Chambers are MWPCs where the time it takes for the ions to reach the sense wire is recorded. This time info gives position info:
IONIZATION DETECTORS “High Energy Physics Phenomenology”
1 Semiconductor Detectors  It may be that when this class is taught 10 years on, we may only study semiconductor detectors  In general, silicon provides.
Experiences with RPC Detectors in Iran and their Potential Applications Tarbiat Modares University Ahmad Moshaii A. Moshaii, IPM international school and.
Particle Detectors for Colliders Ionization & Tracking Detectors
Carleton University A. Bellerive, K. Boudjemline, R. Carnegie, A. Kochermin, J. Miyamoto, E. Neuheimer, E. Rollin & K. Sachs University of Montreal J.-P.
Muon System and Physics Performance Ludovico Pontecorvo CERN-INFN.
Radiation Electromagnetic radiation Ionizing radiation –capable of separating molecules into cations and anions –e.g. X-rays Non-ionizing radiation –doesn’t.
Monday, Mar. 7, 2005PHYS 3446, Spring 2005 Jae Yu 1 PHYS 3446 – Lecture #12 Monday, Mar. 7, 2005 Dr. Jae Yu Particle Detection Ionization detectors MWPC.
TIDE TESTS AT GDD LAB M. Casiraghi and F. Vasi. New detector configuration Low pressure chamber anode.
Instrumentation Review. Direct and Indirect Ionization Direct - Charge particles that strip away electrons from atoms Indirect - uncharged that have to.
Chevron / Zigzag Pad Designs for Gas Trackers
Muon Detector Jiawen ZHANG Introduction The Detector Choices Simulation The structure and detector design The Expected performance Schedule.
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
Study of UV absorption and photoelectron emission in RPC (Resistive Plate Counters) detector with an UV source Carlo Gustavino (INFN-LNGS) RPC and their.
Ionization Detectors Basic operation
Seeing the Subatomic Stephen Miller Saturday Morning Physics October 11, 2003.
RPCs in CMS Supreet Pal Singh India-CMS Meeting, July 20-21, 2007
RPCs of BESIII Muon Identifier  BESIII and muon identifier  R&D  Mass production  Installation Zhang Qingmin Advisor: Zhang Jiawen.
Medical Image Analysis Interaction of Electromagnetic Radiation with Matter in Medical Imaging Figures come from the textbook: Medical Image Analysis,
M. Bianco On behalf of the ATLAS Collaboration
Wednesday, Oct. 18, 2006PHYS 3446, Fall 2006 Jae Yu 1 PHYS 3446 – Lecture #12 Wednesday, Oct. 18, 2006 Dr. Jae Yu 1.Particle Detection Ionization Detectors.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Determining Radiation Intensity
PHYSICS 225, 2 ND YEAR LAB NUCLEAR RADIATION DETECTORS G.F. West Thurs, Jan. 19.
Ion signals with R134a and R134 in a parallel plate proportional counter Edwin Norbeck, J. E. Olson, Y. Onel University of Iowa For Sec. DH-3 of DNP06.
Peter Shanahan – Fermilab Neutrino Scattering Experiment meeting March 14, RPCs in a NuMI Environment Introduction to RPCs Principles of operation.
2002 LHC days in Split Sandra Horvat 08 – 12 October, Ruđer Bošković Institute, Zagreb Max-Planck-Institute for Physics, Munich Potential is here...
Ion signals with R134a and R134 in a parallel plate proportional counter Y. Onel, E. Norbeck, J. E. Olson University of Iowa For HCAL meeting at Fermilab.
Chapter V Radiation Detectors.
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
Small, fast, low-pressure gas detector E. Norbeck, J. E. Olson, and Y. Onel University of Iowa For DNP04 at Chicago October 2004.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
RPCs with Ar-CO2 mix G. Aielli; R.Cardarelli; A. Zerbini For the ATLAS ROMA2 group.
Thorsten Lux. Charged particles X-ray (UV) Photons Cathode Anode Amplification Provides: xy position Energy (z position) e- CsI coating 2 Gas (Mixture)
An extension of Ramo's theorem to include resistive elements
CMS muon detectors and muon system performance
Ionization detectors ∆
1 Principles of Radiation Detection Operational Radiological Safety Course U.S. Army Chemical Biological Radiological & Nuclear School Edwin R. Bradley.
PHYS 3446 – Lecture #16 Monday ,April 2, 2012 Dr. Brandt
Presentation transcript:

1 Geiger-Mueller Tube  Introduced in 1928 by Geiger and Mueller but still find application today Used in experiments that identified the He nucleus as being the same as the alpha particle

2 Geiger-Mueller Tube  Operation Increasing the high voltage in a proportional tube will increase the gain  The avalanches increase not only the number of electrons and ions but also the number of excited gas molecules These (large number of) photons can initiate secondary avalanches some distance away from the initial avalanche by photoelectric absorption in the gas or cathode Eventually these secondary avalanches envelop the entire length of the anode wire Space charge buildup from the slow moving ions reduce the effective electric field around the anode and eventually terminate the chain reaction

3 Geiger-Mueller Tube

4  Gas The main component is often argon or neon However when the large number of these noble ions arrive at the cathode and are neutralized, the released energy can cause additional free electrons to be liberated from the cathode This gives rise to multiple pulsing (avalanches) in the G-M tube

5 Geiger-Mueller Tube  Gas Multiple pulsing can be quenched by the addition of a small amount of chlorine (Cl 2 ) or bromine (Br 2 ) (the quench gas) As we mentioned earlier, collisions between ions and different species of gas molecules tend to transfer the charge to the one with the lowest ionization potential When the halogen ions are neutralized at the cathode, disassociation can occur rather than extraction of a free electron

6 Geiger-Mueller Tube  Use Geiger tubes are often used as survey meters to detect or monitor radiation  They are rarely used as dosimeters but there are some applications Survey meters generally have units of CPM or mR/hr but beware/check the calibration information If calibrated, the survey meter is calibrated to some fixed gamma ray energy  For other gamma ray energies one must account for differences in efficiency

7 Geiger-Mueller Tube

8 Geiger Tube  How is 900V generated from 1.5V batteries? Diodes are nonlinear circuit elements that only conduct current in one direction

9 Geiger Tube  Voltage doubler

10 Geiger Tube  On one half-cycle, D1 conducts and charges C1 to V  On the other half-cycle D2 conducts and charges C2 to 2V  A long string of half-wave doublers is known as a Cockcroft-Walton multiplier

11 Geiger Tube  This can be extended to an n multiplier

12 Proportional Counters  Many different types of gas detectors have evolved from the proportional counter

13 Proportional Counters  Most of these variants were developed to improve position resolution, rate capability, and/or cost MWPC (multi-wire proportional tube) CSC (cathode strip chamber) Drift chamber (e.g. MDT) Micromegas (micromesh gaseous detector) RPC (resistive plate chamber)  Nearly every application has made some attempt to transfer to medical applications

14 Momentum Measurement  Let v, p be perpendicular to B

15 Momentum Resolution  The sagitta s can be determined by at least 3 position measurements This is where the position resolution of the proportional chambers comes in

16 Magnets  Solenoid Large homogeneous field Weak return field in return yoke Dead material in beam  Toroid Field always perpendicular to p (ideal) Large volume Non-uniform field Complex

17 Magnets  ATLAS  CMS

18 Magnets

19 Momentum Resolution  ATLAS muon momentum resolution

20 Multiwire Proportional Chambers (MWPC’s)  Nobel prize to Charpak in 1992 Simple idea to extend the proportional tube Effectively spawned the era of precision high energy physics experiments

21 MWPC’s  You might expect that because of the large C between the wires, a signal induced on one wire would be propagated to its neighbors  Charpak observed that a positive signal would be induced on all surrounding electrodes including the neighbor wires (from the positive ions moving away)

22 MWPC’s  Typical parameters Anode spacing – 1-2 mm Anode – cathode spacing – 8 mm Anode diameter – 25  m Anode material – gold plated tungsten Cathode material – Aluminized mylar or Cu-Be wire Typical gain

23 Cathode Strip Chambers (CSC)  The negative charge induced on the anode induces positive charge on the cathodes This provides a second detectable signal If the surface charge density is sampled by separate cathode electrodes then the location of the avalanche can be determined If the cathode pulse heights are well measured the position resolution can be precisely determined (~100μm vs 600μm for 2mm/√12)

24 Cathode Signal  Consider the geometry  The cathode charge distribution is given by Where λ = x/d and K i are geometry dependent constants

25 Cathode Signal  The shape is quasi- Lorentzian with a FWHM ~ 1.5 d, where d is the anode-cathode spacing

26 Cathode Signal  In order to reduce the number of readout channels one can use capacitive coupling between strips Strip pitch is one- half or one-third Readout pitch stays the same

27 ATLAS Muon System

28 ATLAS Muon System - Barrel

29 ATLAS CSC’s

30 ATLAS CSC’s

31 ATLAS CSC’s  Some numbers 16 four-layer CSC’s per side Both r (precision) and  (transverse) position is measured for each layer  Each CSC has 4 x 192 precision strips  Each CSC has 4 x 48 transverse strips  32,000 channels total

32 ATLAS CSC’s

33 ATLAS CSC’s

34 ATLAS CSC’s

35 Drift Chambers  Another variation on the MWPC is the drift chamber

36 Drift Chambers  Advantages Better position resolution Smaller number of channels  Disadvantages More difficult to construct Need time measurement  The position resolution of drift chambers is limited by diffusion, primary ionization statistics, path fluctuations, and electronics  Many different geometries are possible

37 Drift Chambers  Planar chambers

38 Drift Chambers  CDF central tracker

39 ATLAS MDT’s

40 ATLAS MDT’s

41 ATLAS MDT’s

42 ATLAS MDT’s  Some numbers ~1200 drift chambers with ~ drift tubes Covers ~5500 m 2 Optical monitoring of relative chamber positions to ~ 30  m Ar:CO 2 (93:7) pressurized to 3 bar Track position resolution ~ 40  m

43 Micromegas Detector

44 Micromegas  Principle of operation Bulk micromegas use photolithographic techniques to produce narrow anodes and precise micromesh – anode spacing

45 Micromegas

46 Micromegas

47 Resistive Plate Chambers (RPC’s)  Principle of operation Very high electric field (few kV/mm) induces avalanches or streamers in the gap High resistivity material localizes the avalanche Signal is induced on the readout electrodes

48 RPC’s  Avalanche mode Like a proportional chamber  Streamer mode Small “spark”  Excellent time resolution 1-2 ns  In both cases charge must recover to re- establish E field after avalanche or streamer _ _ _ _ _ _ _ _ _ _ _ Before _ _ _ _ _ _ _ After

49 RPC’s

50 ATLAS RPC’s Bakelite Plates Foam PET spacers Graphite electrodes X readout strips HV Y readout strips Grounded planes Gas 2mm gas gap 8.9kV operating voltage

51 ATLAS RPC’s  A few notes on linseed oil The linseed oil lowers the current draw through the gas and the singles rate by a factor of 5-10  It makes a smooth inner surface which gives a uniform electric field  It absorbs UV photons produced in the avalanche Babar RPC’s had problems associated with linseed oil

52 Radiation Units  Exposure Defined for x-ray and gamma rays < 3 MeV Measures the amount of ionization (charge Q) in a volume of air at STP with mass m X == Q/m  Basically a measure of the photon fluence (  = N/A) integrated over time  Assumes that the small test volume is embedded in a sufficiently large volume of irradiation that the number of secondary electrons entering the volume equals the number leave (CPE) Units are C/kg or R (roentgen)  1 R (roentgen) == 2.58 x C/kg  Somewhat historical unit (R) now but sometimes still found on radiation monitoring instruments  X-ray machine might be given as 5mR/mAs at 70 kVp at 100 cm

53 Radiation Units  Absorbed dose Energy imparted by ionizing radiation in a volume element of material divided by the mass of the volume D=E/m Related to biological effects in matter Units are grays (Gy) or rads (R)  1 Gy = 1 J / kg = 6.24 x MeV/kg  1 Gy = 100 rad 1 Gy is a relatively large dose  Radiotherapy doses > 1 Gy  Diagnostic radiology doses < Gy  Typical background radiation ~ Gy

54 Geiger Tube  Notes Survey meters generally have units of CPM or mR/hr Generally the Geiger tube is not used to determine the absorbed dose The G-M tube scale is in mR/hr – what is the absorbed dose? The absorbed dose in air is

55 Geiger Tube

56 Relations  Absorbed dose and kerma  In theory, one can thus use exposure X to determine the absorbed dose Assumes CPE Limited to photon energies below 3 MeV