1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.

Slides:



Advertisements
Similar presentations
Intermediate Course (3) Using Multimeters Karl Davies 1 East Kent Radio Society.
Advertisements

Introduction to the Oscilloscope Professor Ahmadi ECE 002.
1 Cathode Ray Oscilloscope Introduction Look and play Read instructions Break into smaller parts Decide on a simple measurement Increase your level of.
FEKT VUT v BrněHESO / L2 / J.Boušek1 THE OSCILLOSCOPE - shows graphically the behavior of an electrical signal - qualitative measurement type rather than.
Diode Clamper Circuit. By:Engr.Irshad Rahim Memon
Introduction 1st semester King Saud University
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
DC Choppers 1 Prof. T.K. Anantha Kumar, E&E Dept., MSRIT
BASICS OF LAB SCOPES. Scope Essentials Digital Storage Oscilliscope (DSO) Voltmeter that captures voltage samples & displays them on a screen Voltage.
PRINCIPLES OF MEASUREMENT AND INSTRUMENTATION EKT 112
1 EE 188L Lab #2 Test Bench Photos. 2 Vout R1 R5 R4 R3 R C2 C1 R7 R6 At this end there will be a cut-out and/or a dot next to pin 1 -15V.
1 Lab #9 AC Circuits Activity #1 – Simulating a Low Pass Circuit Activity #2 – Building & Testing a Low Pass Circuit Activity #3 – Comparison of 3 methods.
1 Lab #7 – Thevenin/Norton Activity #1 – finding the Thevenin/Norton Equivalent for the function generator –The function generator is a voltage source.
Fluke Oscilloscope 4 Isolated Channels 200 Mhz Bandwidth CAT III 1000 CAT IV 600 Rated 2.5 GS/s sample rate Connect-and-View™ IP-51 Rated.
The Oscilloscope: Basic Features & Functions  Source –Determines which signal is compared to the trigger settings.  Level –Determines where on the edge.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
Electric Curcuits and Measurements Basic Electrical components and their functions Measurements of electrical circuits characteristics - Multimeter - Oscilloscope.
George Washington University DC Circuits Lab Professor Ahmadi ECE 002.
1 AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz.
Magnitude and Phase Measurements
Pulse Width Modulation (PWM) LED Dimmer Circuit
Purpose Learn how to use basic electronic equipment:
The Function Generator and the Oscilloscope Dr. Len Trombetta 1 ECE 2100.
Oscilloscope Tutorial
 Popular instrument to show time, voltage both DC and AC. Shows Volts / Time.  Display waveforms. Spectrum scope shows volts to Frequency  Cathode (-ve.
The Oscilloscope: Advanced Features Wave Inspector® Navigation and Search  Zoom: Zoom in to see more detail.  Pan: Pan through your waveform.  Mark:
Introduction to the Oscilloscope Professor Ahmadi ECE002 George Washington University.
Institute Of Applied Technology ATE 1012 Grade 10 Eng. Rose Hasan.
CHAPTER 9 Oscilloscopes and Graphing Multimeters
Waveform 2.1 Basic Digital Waveforms 2 Measurement Paul Godin Updated October 2009.
1 Cathode Ray Oscilloscope Introduction Look and play Look and play Read instructions Read instructions Break into smaller parts Break into smaller parts.
TA: Chris Reilly Group 5: Benjamin, Ramie, Zachary, Dinal.
TDS 210 BASIC INSTRUCTIONS. Measure 1. Push the MEASURE button to access the automated measurement. 2. capabilities. There are five measurements available.
Project Work 1Lecture LECTURE 4 Repetitive signals Time varying signals e.g. RS-232 signals Oscilloscope.
George Washington University DC Circuits Lab Professor Ahmadi ECE 002.
Circuit Testers and Digital Meters 4 © 2013 Pearson Higher Education, Inc. Pearson Prentice Hall - Upper Saddle River, NJ Advanced Automotive Electricity.
Measuring Phase Difference Dr. Len Trombetta 1 ECE 2100.
Scopes  An oscilloscope is a visual voltmeter.  An oscilloscope converts electrical signals into a visual image representing voltage changes over a.
Introduction to the Oscilloscope
Electronics: Principles and Applications Eighth Edition (Instrumentation Labs) Charles A. Schuler Lab 2 Introduction to the Oscilloscope McGraw-Hill©2013.
Vadodara Institute of Engineering kotanbi Active learning Assignment on Single phase AC CIRCUIT SUBMITTED BY: 1) Bhatiya gaurang.(13ELEE558) 2)
Unit 5 Learning Objective(s) L5.1a To understand the need for safe working practices when carrying out practical electronics L5.1b To understand relevant.
Physics 2225: Working With Electronic Equipment Purpose  Learn how to use basic electronic equipment: Digital multi meter Oscilloscope Function generator.
Introduction to the Oscilloscope Professor Ahmadi ECE 002.
Lab instruments ELCT 201 Digital Multimeter Voltage Tester
PRESENTS GENISYS LAB SCOPE TECH TRAINING. To do on car testing, scroll to Diagnostic Toolbox and press Enter. Enter Scroll to Diagnostic Toolbox.
Velleman Oscilloscope: Windows 7 by Mr. David Fritz.
AC Measurements Topics covered in this presentation:
The University of Texas at Arlington Electrical Engineering Department
Lecture 5: DMM & Oscilloscope 1. DMM can be used to measure: DC & AC voltages – current - resistance - BJT (β test) - diode test - short circuit test,
The Basics Electronics. To familiarise yourself with electronics To have an understanding of how and why we test electronic circuits. To complete a test.
In this lesson, you will learn how to set up a Digital Multimeter (DMM) to perform various measurements Click on each question to learn more How is the.
Scope TEKTRONIX TDS. Frontal View Menu and Control Buttons Multipurpose knob.
BASIC INSTRUMENTS - oscilloscopes
1 Phase Angle Measurement Using the Oscilloscope This procedure measures the phase angle difference between two sinusoidal waveforms connected to channels.
Lab 7 Hints. Activity 1C, 1B Activity 1A Battery or power supply (in previous picture)
Simple Circuits 1 st year physics laboratories University of Ottawa
Digital Multimeter – Basic Guide
Chapter 9 CAPACITOR.
Using electrical Test Equipment To accompany the Georgia Agriculture Curriculum Course: AG-AG-AMII Using Electrical Test Equipment 2010 VGP.
The Function Generator and the Oscilloscope Dr. Len Trombetta and Dr. Dave Shattuck 1 ECE 2100.
DONE BY : RAWDA ALNWAISEH BAYAN TALEB
Residential Cabling Technologies Copyright © 2005 Heathkit Company, Inc. All Rights Reserved Electrical Measurements.
Mrs V.S.KharoteChavan,E&Tc,PC poly
(5) DMM & Oscilloscope.
Introduction to the Oscilloscope
Oscilloscopes HP 54600B Digital Oscilloscope Alex Jones COE 0501.
Multimeter Purpose Used to measure Voltage and Current around a circuit. Multimeter is the generic name given to the universal, Volt, Amp, and Ohmmeter.
6. USING THE TDR200 IN ANALOGUE MODE
Automotive Technology Principles, Diagnosis, and Service
Presentation transcript:

1 Lab Equipment

2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope – triggering25-32 Scope – exploring the waveform33-34 Scope – trace rotation and probe compensation35-40 Scope – rise/fall time measurements41-47 Scope – computer communication problems48 Contents

3 DC Power Supply All three supplies share a common terminal, which is NOT connected to the power supply “ground”. This terminal should normally be connected to your circuit “ground”. The negative 0 to 20 volt supply is proportional (by an adjustable ratio of up to -1) to the positive supply Vneg = (0 to –1) times Vpos Don’t use; connects to chassis and power line gnd DC = 0 to Vpos DC = 0 to 6 DC = 0 to Vpos

4 DC Power Supply DC = 0 to Vpos DC = 0 to 6 DC = 0 to C BA D Since the COM terminal is isolated from the power supply ground, you are not limited to using point B for your circuit ground. If you use point A, C, or D as your circuit ground you can use series combinations of the three internal voltage sources to obtain voltages higher than +20V and lower than –20V. Vpos

5 Digital Multimeter (DMM) Power switch DC voltage AC voltage DC current AC current Resistance AC = RMS value of AC part of waveform only DC = value of DC part of waveform only To measure TRUE RMS value of the complete waveform, press both DC and AC Range is set automatically

6 Diode test (passes small current through diode and measures the resulting voltage drop) Connect the RED lead to the diode anode and the black lead to the cathode.

7 Use the RATE switch to set the speed of measurement and the resolution of the displayed values: F = fast speed = low resolution M = medium speed = medium resolution S = slow speed = high resolution

8 10 AMP current input has low internal resistance and introduces the lowest error; use this input whenever possible 100 milliamp current input has considerable internal resistance and may introduce considerable error; use the 10 A input whenever possible. For current measurements, move the RED lead to a current input

9 Function Generator output Select waveform Set frequency, amplitude, and DC offset

10 To enter values, press “Enter Number”, then the number keys, then “Enter” Observe decimal point; ignore the commas

11 When entering values, use these keys to define the units. Notice that voltage values can be defined as either RMS or peak-to-peak.

12 If the amplitude of the waveform measured by the scope or digital multimeter does not agree with the amplitude shown on the function generator display, reset the output termination to “HIGH Z” “SYS Menu” > “OUT TERM” EnterShift> “50 OHM ”“HIGH Z ” >> > > Enter

13 Oscilloscope Always adjust the scope to obtain as large of a waveform as possible (to maximize accuracy) Adjust the FOCUS and INTENSITY to obtain a clear, readable display. When not actively observing waveforms, turn down the intensity to extend the life of the scope screen Function buttons

14 The AUTO SET button helps the scope find the waveform, but it also sets the waveform signal coupling to AC (undesirable) After using the AUTO SET button, reset the waveform signal coupling to DC using the AC/DC buttons General Rule: ALWAYS use DC coupling on the vertical channels so that you can observe the complete (AC & DC) waveform

15 The VAR controls must be in the CAL position for the display values to be valid

16 Use the X POS control to start the scope trace at the left edge of the grid

17 Set the zero volt positions for ch A and ch B to known positions on the grid, usually the center horizontal line, by first selecting GND and then adjusting the Y POS controls

18 Zero voltage reference line set to known point (usually center line, but may anywhere you desire) Once positioned, be careful not to change it. Trace starts at first vertical grid line Example of Setting Zero Volt Reference

19 vertical and horizontal values per division (cm) are shown on the display Use these to set the vertical (voltage) values per division Use this control to set the horizontal (time) value per division

20 DIGITAL MEMORY mode must be selected to be able to use cursors and transfer waveforms to the computer

21 Use function buttons to control cursors Scope Cursors

22 Cursor Positioning Buttons Controls lower cursor Controls upper cursor Controls left cursor Controls right cursor RETURN key takes you back to the previous higher level

23 Setting the Cursor Mode and Reference Channel Use to turn cursors on/off and to select what they display (vertical measurement = voltage or ratio; horizontal measurement = time, phase angle, or ratio) Voltage cursor will use either channel A or B “voltage per division” setting, as selected. RETURN key takes you back to the previous higher level cursor reference channel Reference channel selection available only when both channels A and B are displayed

24 Value of differences between horizontal (voltage) cursors Value of difference between vertical (time) cursors Frequency computed from inverse of time interval (valid only if interval is one cycle)

25 Scope Triggering The waveform on the scope display is drawn from left to right (repetitively), beginning at a point when one of the signals being displayed meets a specified criteria. This criteria is defined by the settings of the horizontal (time base) trigger controls: Mode - the standard mode is AUTO Source - which signal is being used to trigger the scope Coupling - normally P-P (AC), but sometimes DC gives more control Slope - the scope trace begins on the upward or downward slope of the wave Level - the voltage level of the wave at which the trace begins

26 Sets the trigger mode (normally set to AUTO) Displays the trigger mode Displays trigger slope Sets the trigger slope Displays trigger source and coupling Sets trigger coupling Sets trigger source Adjusts the trigger level Horizontal (time base) trigger controls

27 To capture a non-repetitive waveform, set the desired trigger conditions, select the SINGLE TRACE trigger mode, then press RESET to “arm” the scope. After the scope has been “armed”, a single trace will be drawn when the signal level matches the trigger conditions (slope and level) you have selected. The trace will remain displayed until you press RESET or transfer the waveform to the computer. Single Trace Operation

28 Trigger level set to zero volts and a positive (upward) slope Example Waveform

29 Trigger level set to +1 volt, with a positive slope Zero volt reference line Example Waveform

30 Trigger level set to –1 volts, with a positive slope Zero volt reference line Example Waveform

31 Trigger level set to zero volts, with a negative (downward) slope Example Waveform

32 The trigger delay can be used to shift where the trigger point appears on the screen; this allows you to observe the waveform up to 10 divisions prior to the trigger point on repetitive waveforms. Delayed Trigger

33 Use the X-magnification button to zoom in on part of the waveform; the magnification factor is changed each time you press the button. Waveform Zoom

34 Use the Display Part rocker switch to move the display window across the waveform image stored in the scope. (The scope stores two screen widths of data at X1 magnification) Move the display window

35 Adjust to make trace parallel with horizontal grid Trace Rotation

36 Scope Probe Compensation Adjustment Connect probe to calibration signal Make sure channel A and B signal coupling are set to DC

37 Scope Probe Compensation Adjustment Each probe has an adjustment screw that changes the compensating capacitor

38 Scope Probe Compensation Adjustment Adjustment capacitor value needs to be increased until waveform is rectangular

39 Scope Probe Compensation Adjustment Adjustment capacitor value needs to be decreased until waveform is rectangular

40 Scope Probe Compensation Adjustment Rectangular waveform with correct probe adjustment

41 0% 10% 90% 100% For rise or fall time measurements, use the 0%, 10%, 90%, and 100% lines on the scope grid Making Rise and Fall Time Measurements on Pulse Waveforms

42 Using the vertical scale control to set your waveform amplitude so that it is greater than the range of 0% to 100% Then use the var and the Ypos controls to line up your waveform with the 0% and 100% grid lines.

43 100% 90% 10% 0% The adjusted waveform display

44 Expand the waveform horizontally using the time base (TB) control Set the trigger slope to positive (upward) for rise time measurements Set trigger coupling to DC Adjust trigger level to the 10% point or below For rise time measurements

45 Adjust the vertical cursors so that they pass the 10% and 90% points on the waveform, and read off the rise time. 10% 90%

46 Expand the waveform horizontally using the time base (TB) control Set the trigger slope to negative (downward) for rise time measurements Set trigger coupling to DC Adjust trigger level to the 90% point or above For fall time measurements

47 Adjust the vertical cursors so that they pass the 10% and 90% points on the waveform, and read off the fall time. 10% 90%

48 Use OPTION function button to check or correct communications settings If scope fails to communicate with the computer: OPTION IEEE IEEE-ADDR: 8 MODE: talker/listener If you have to correct the communications settings, cycle the scope power to reset the communications interface.