Beam Condition Monitor for the CMS BCM Group Luis Fernández Hernando (EST/LEA), Christoph Ilgner (EST/LEA), Alick Macpherson (CMS/CMM), Alexander Oh (CMS/CMD),

Slides:



Advertisements
Similar presentations
Proton and neutron radiation facilities in the PS East hall at CERN Maurice Glaser, Michael Moll, Federico Ravotti CERN.
Advertisements

Sci-Fi tracker for IT replacement 1 Lausanne 9. December 2010.
FLUKA studies: channeled ions on LHC IP7 L. Lari (CERN & IFIC (CSIC-UV)) D. Mirarchi (CERN & ICL) A. Lechner (CERN) ColUSM#32 December the 6 th,
MERIT Pump/Probe Data Analysis Outline  The pump/probe program  Particle detector response correction  Pump/probe analysis results NFMCC Collaboration.
H. Pernegger, CERN, RD42 coll. Meeting May 2004 Diamond Beam Conditions Monitor for ATLAS (H. Pernegger, CERN)
TheBeam Conditions Monitor at ATLAS experiment Abstract The Beam Conditions Monitor at ATLAS experiment is being developed as a stand-alone device allowing.
CMS ECAL Laser Monitoring System Toyoko J. Orimoto, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
M. Palm, CERN1 Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA.
RD42 Meeting, CERN W. de Boer, Univ. of Karlsruhe 1 CVD diamonds as beam monitors CVD diamond used for: heavy ion beam monitor beam exit window.
Measurements on single and poly crystal diamond samples at CERN Luis Fernandez-Hernando Christoph Ilgner Alick Macpherson Alexander Oh Terry Pritchard.
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
Manuel FahrerCMS Week TB Meeting /6 1-Shot Test Beam CERN CMS: M.Huhtinen, R.Hammarstrom, A.Macpherson CERN ATLAS, PS, Karlsruhe CMS  Overview.
VELO Testbeam 2006 Tracking and Triggering Jianchun (JC) Wang Syracuse University VELO Testbeam and Software Review 09/05/2005 List of tasks 1)L0 trigger.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
Radiation Damage in the CMS Strips Tracker Christian Barth on behalf of the CMS Tracker Collaboration.
Chamonix XV 25/01/2006 Beam Conditions and Radiation Monitoring Concerns of the Experiments Alick Macpherson CERN/Rutgers University.
Laser Stripping and H 0 monitor systems 10/18/2011B.Cheymol, E. Bravin, U. Raich, F. Roncarolo BE/BI1.
Radiation Test Facilities G. Spiezia. Engineering Department ENEN Radiation tests facilities  Radiation test in the accelerator sector  External facilities.
ATLAS Forward Detector Trigger ATLAS is presently planning to install forward detectors (Roman Pot system) in the LHC tunnel with prime goal to measure.
H. Matis, M. Placidi, A. Ratti, W. Turner [+ several students including S. Hedges] (LBNL) E. Bravin (CERN), R. Miyamoto (BNL – now at ESSS) H. Matis -
LPROT Experiment TE/MPE/PE EN/STI EN/MME. Objectives Create the conditions to produce hydrodynamic tunneling. Benchmarking FLUKA-BIG2 simulations. Assert.
Status of Beam loss Monitoring on CTF3 Results of Tests on LINAC and PETS as R&D for TBL Anne Dabrowski Northwestern University Thibaut Lefevre CERN CTF3.
Diamond Sensor Diamond Sensor for Particle Detection Maria Hempel Beam Impact Meeting Geneva,
Shan Liu, Philip Bambade, Sha Bai, Dou Wang, Illia Khvastunov ECFA, Hamburg, 29 May, 2013.
Si-detector macroscopic damage parameters during irradiation from measurements of dark current evolution of with fluence Craig Buttar, University of Sheffield.
Background Simulations for the LHCb Beam Condition Monitor Overview: ● The LHCb Beam Condition Monitor (BCM) – Purpose, Design and Function – Implementation.
Diamond Detectors Christoph Kurfuerst BE-BI-BL Ewald Effinger BE-BI-BL.
P. 1Mario Deile – Meeting on Experiment Protection from Beam Failures Protecting TOTEM Mario Deile PH-TOT
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
15 February 2007Dirk Wiedner / LHCb1 Radiation Monitors for LHCb.
IEEE NSS 2007 D.Kramer 1 Very High Radiation Detector for the LHC BLM System based on Secondary Electron Emission Daniel Kramer, Eva Barbara.
Introduction to Irradiation Facilities 1. Challenges at LHC and Why we need Irradiation Facilities (Mar CAPEANS) 2. PH Department Proton and Neutron Facilities.
Technical Meeting Diamond Detector Characterization in Frascati F. Burkart F. Burkart, O. Stein.
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
PPAC in ZDC for Trigger and Luminosity Edwin Norbeck University of Iowa Luminosity Workshop November 5, 2004.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
Beam Secondary Shower Acquisition System: BWS pCVD Measurements on SPS BA5 BWS51731 BE-BI-BL Jose Luis Sirvent Blasco 2 Jose Luis Sirvent.
Interface of FP420 to LHC FP420 meeting 28-Sep-2006.
ATLAS LAr Forward Calorimeters C. Zeitnitz (Universität Wuppertal) for the ATLAS LAr Community.
Measurements of Intense Proton Beams using Optical Transition Radiation Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011.
1 Single event upset test of the voltage limiter for the ATLAS Semiconductor tracker TSL Experiment Number: F151 distance between power supplies and modules.
Beam on Target Diagnostics Beam on Target Meeting 2013 March Tom Shea.
H. Matis, S. Hedges, M. Placidi, A. Ratti, W. Turner [+several students] (LBNL) R. Miyamoto (now at ESSS) H. Matis - LARP CM18 - May 8, Fluka Modeling.
Simulation Plan Discussion What are the priorities? – Higgs Factory? – 3-6 TeV energy frontier machine? What detector variants? – Basic detector would.
PPAC Jonathan Olson University of Iowa Thesis Defense 8 April 2005.
Philip Bambade, Pierre Barillon, Frédéric Bogard, Selma Conforti, Patrick Cornebise, Shan Liu, Illia Khvastunov Journée PHIL
Proton and neutron irradiation facilities in the CERN-PS East Hall Maurice Glaser and Michael Moll CERN- PH-DT2 - Geneva - Switzerland 6 th LHC Radiation.
RD05 Florence CVD Diamond Radiation Sensors For Application In Very High Radiation Environments 7 th International Conference on Large Scale Applications.
Upgrade of the irradiation facilities in the PS East Hall Maurice Glaser, Michael Moll 30 April 2010 – PH-DT steering board meeting activities are part.
NMLTA Protection System Update -Loss Monitors- Arden Warner September 2 nd, 2009.
Beam detectors in Au+Au run and future developments - Results of Aug 2012 Au+Au test – radiation damage - scCVD diamond detector with strip metalization.
Integration of forward physics detectors into the LSS of the LHC D. Macina (TS/LEA) Technical Support 2004 Workshop.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
Beam Secondary Shower Acquisition System: Front-End RF Design
Belle-II VXD radiation monitoring and beam abort with sCVD diamond sensors Lorenzo Vitale, Belle-II SVD collaboration INFN and Univ. Trieste, ITALY Requirements.
Radiation Monitor: Concepts, Simulation for an Advanced Read Out
Measurements and FLUKA Simulations of Bismuth and Aluminum Activation at the CERN Shielding Benchmark Facility(CSBF) E. Iliopoulou, R. Froeschl, M. Brugger,
dBLM Hardware and Signal
Development of the muon monitor for the T2K experiment
Summary: Workshop on CMS Beam Conditions, Radiation Monitoring and Luminosity Systems Oliver Stein, May 2013, CERN.
Machine Protection Xu Hongliang.
Particle Detection System for MERIT
Beam Tests of Ionization Chambers for the NuMI Neutrino Beam Monitoring System MINOS.
Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA M. Palm, CERN.
Pre-installation Tests of the LHCb Muon Chambers
Commissioning of the Beam Conditions Monitor of the LHCb Experiment at CERN Ch. Ilgner, October 23, 2008 on behalf of the LHCb BCM group at TU Dortmund:
Particle Detection System for MERIT
Summer Student Presentation
Presentation transcript:

Beam Condition Monitor for the CMS BCM Group Luis Fernández Hernando (EST/LEA), Christoph Ilgner (EST/LEA), Alick Macpherson (CMS/CMM), Alexander Oh (CMS/CMD), Terry Pritchard (CMS/CMM), Bob Stone (CMS/CMT)

Beam Condition Monitor for CMS Purpose –The Beam Condition Monitor (BCM) has to provide online radiation monitoring within the CMS –BCM forms part of the radiation monitoring system for equipment safety and radiation level/beam monitoring –The BCM should be in addition to the LHC machine protection system and Beam Loss Monitors BCM Issues –Allows protection of equipment during instabilities/accidents –Provides fast feedback to the machine for optimization of beam conditions –Provides fast feedback to the machine for detection of adverse beam conditions –Monitors the instantaneous dose during operation –Provides input into LHC beam abort system (1 input/ experiment)

Accident Scenarios Sensors under investigation: Polycrystalline Diamond Fast signal response Radiation hardness Minimal services required ie no cooling necessary Unsynchronised beam abort: ~10 12 protons lost in IP 5 in 260ns z=±1.8m and r=4cm Beam condition monitors Looking for increase over normal rate Monitors to be within CMS and feed to machine interlock Sensors to be placed in the Pixel volume and after the Forward calorimeter Evaluated using a fast extraction beam from the CERN PS at the T7 beamline (November 2003)

Beam Accidents What are the timescales List of machine-identified equipment failures Fastest generic beam loss scenarios: ~ in 5 orbits ie ~ 500µs the beam is off by 3 sigma, this defines the response timescale of our system. NameOperation Mode Loss LocationΔT D1 warmCollisionTriplet/collimator5 turns DamperInjectionArc/triplet6 turns Warm quadrupolesAnyCollimator18 turns Warm orbit correctorCollisionTriplet/collimator55 turns RFAnyArc/triplet/septum55 turns D1 warmInjectionArc/triplet/collimator120 turns

Beam Accidents What are the timescales A MAD simulation for a D1 failure will serve us to calculate the numbers of protons that will be lost per turn. Then a Fluka simulation can give us the dose per turn that will allow us to set the timescales and the thresholds.

Conceptual BCM layout Cable Length ~11.5m Fast Amplifiers Placed outside CMS

DCS Monitoring and control of the detector DSS Safeguard of experimental equipment BCM Input into DSS. Protect subdetectors from adverse beam conditions Redundant of the Beam Loss Monitors of the Machine BCM sensors

T7 Testbeam Hardware CDS126: 1x1cmx300 um thick Collection dist ~ 110 um 3x1cmx500 um thick Collection dist ~ 40 um CDS116: 1x1cmx500 um thick Collection dist ~ 125 um Detector assembly Assembly in the beam shuttle Beam spot and dosimetry Signal cable= RG58 coax 3x protons/cm 2 at centre Diamond samples Shielding box HV line

November T7 Test beam: Fast extraction beam from the PS 4  width= 42ns Interbunch spacing= 262ns Beam intensity: 8x10 11 protons per spill Fluence: ~3x10 10 protons/cm 2 /spill at the centre of the beam spot ~1x10 8 protons/cm 2 /spill in the halo

Beam profile Film exposure of the beam after 40 bunches = test point for placement of sensor 6cm Relative fluence levels Position 0 = 1.0 Position 1 ~ 0.4 Position 2 ~ 0.2 Position 3 ~ 0.01 Beam Profile as measures by OSL film OSL =Optically Stimulated Luminesence 90 mm 55mm

9cm Dosimetry measurements Dosimetry Results from Grid of Aluminum samples: Relative variation % Beamspot Dosimetry Used 24 Na for dosimetry on aluminum placed in the beam Dosimetry done by Maurice Glaser and Federico Ravotti Result Fluence at beam “centre” = 2.8x10 10 protons/cm 2 ± 10% Mapping of beam spot Consistency between the different films, the OSL, and the aluminum

Single shots Single pulses from diamond Bias on Diamond = +1 V/ µm Readout of signal: 16m of cable no electronics 20dB attenuation on signal cable (factor 10) Almost identical to PS beam profile

Single shots: Details Diamond Collection Distance Diamond signal ~ collection distance Collection distance (CDS116) ~125 µ m Collection distance (CDS126) ~110 µ m For std bias voltage of 1 V/µm Diamond Collection Distance Signals from sensors are large V_max (CDS116) = 88 volts => 1.76 Amps into a 50 Ohm load V_max (CDS126) = 61 volts => 1.22 Amps into a 50 Ohm load Area of pulse Proportional to current from a bunch. Use area to estimate bunch fluence. Pulse 3) = 9.8x10 7 p/cm 2 Pulse 3) = 8.7x10 7 p/cm 2 Fair agreement with dosimetry results Pt 3) = 2.2x10 8 p/cm 2 Time response Fit Gaussian to leading edge of pulses  (CDS126) =10.5 ± 0.5 nsComparable to  (PS)=10.5 ns with  (CDS116) = 9.0 ± 0.3 ns~6% distortion from the signal cable => No problem with extracting timing structure from sensors on 16 m coax cable

Multiple Bunches Diamond C1 acts as a reservoir capacitor =>The larger the value the longer the bias field on the can be maintained. C1(CDS126)=15 nF C1 is sufficiently large to maintain bias across the diamond for the 8 bunches. C1R1 time constant ~15 ms  recharge of C1 is slow compared to bunch structure R1=R2 =1M  A 262ns SPICE Simulation of Voltage at Pt A C1

Multiple Bunches CDS126 (110 µ 300V). The integration of the gaussian fit for the first peak gives a value of 9.05x10 7 p/cm 2 CDS116 (125 µ 500V). The integration of the gaussian fit for the first peak gives a value of 1.2x10 8 p/cm 2

Multiple Bunches CDS126 at 30 V bias. The amplitude of the signal for the first bunch is close to the bias voltage. Also shown is the bias field during the seven bunch shot. The diamond acts as a quasi conductor due to the high ionization density during each bunch and discharges the reservoir capacitance.

Conclusions CVD diamonds are able to withstand intense beams. They have been exposed to particle fluxes similar to an unsynchronized beam abort within the CMS experiment. Under such conditions the diamond samples are found to respond and recover from consecutive high intensity beam bunches. The observed high currents generated in the diamond from conditions similar to an unsynchronized beam abort require that a protection system for the BCM readout electronics be implemented.