Clinical Neutron Therapy Center Donna Kubik Spring, 2005.

Slides:



Advertisements
Similar presentations
Applications of the Motion of Charged Particles in a Magnetic Field AP Physics C Montwood High School R. Casao.
Advertisements

Detectors and Accelerators
QUANTA TO QUARKS DOT POINT 4.4 Identity ways by which physicists continue to develop their understanding of matter, using accelerators as a probe to investigate.
PH0101 Unit 2 Lecture 4 Wave guide Basic features
Radiopharmaceutical Production
Experience, Expertise and a Commitment to Excellence™
Particle Accelerators
Magnetic Fields Magnetic Field Forces on a Charged Particle Magnetic Field Lines Crossed Fields and Hall Effect Circulating Charged Particles Cyclotrons.
2/xx/07184 Lecture 221 PHY 184 Week 6 Spring 2007 Lecture 22 Title: The Lorentz Force = q v x B.
Charged Particles in Electric and Magnetic Fields Motion of charged particles Lorentz Force Examples: cyclotron, mass spectrometer.
Copyright © 2009 Pearson Education, Inc. Force on an Electric Charge Moving in a Magnetic Field.
Cairo University Electrical Engineering – Faculty of Engineering Cyclotrons Yasser Nour El-Din Mohammed Group 2 - Accelerators and Applications Supervisors.
The Magnetic Field Profile of New Pole Tips on the Rutgers 12-inch Cyclotron John McClain Robert Friedman.
Nuclear Physics: Radiation, Radioactivity & its Applications.
1 Bragg Curve  Protons and Carbon. 2 Application of Range  The localized energy deposition of heavy charged particles can be useful therapeutically.
Copyright © 2009 Pearson Education, Inc. Lecture 8 - Magnetism.
K L University 1. 2 MAGNETOSTATICS 3 Introduction to Magneto statics – Magnetic field, Magnetic force, Magnetic flux Biot-Savat’s law -- Applications.
ALPHA Storage Ring Indiana University Xiaoying Pang.
Lecture 11  Production of Positron Emitters, Continued  The Positron Tomograph.
PAMELA Contact Author: CONFORM is an RCUK-funded Basic Technology Programme PAMELA: Concepts Particle Accelerator for MEdicaL Applications K.Peach(JAI,
Eric Prebys, FNAL.  We consider motion of particles either through a linear structure or in a circular ring USPAS, Knoxville, TN, Jan , 2014 Lecture.
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
Nuclear Energy Effects and Uses of Radiation
Particle accelerators and detectors -Short Answers.
March 2011Particle and Nuclear Physics,1 Experimental tools accelerators particle interactions with matter detectors.
Physics of Particle Accelerators Kalanand Mishra Department of Physics University of Cincinnati.
General electric flux definition
Particle Accelerators
Authorization and Inspection of Cyclotron Facilities Cyclotron Accelerators: Operation and Components.
Tools for Nuclear & Particle Physics Experimental Background.
ACCELERATORS class of “High Energy Physics Phenomenology” Mikhail Yurov Kyungpook National University October 25 th.
SPECIALISED CYCLOTRON FOR BEAM THERAPY APPLICATION Yu. G. Alenitsky, A
The Magnetic Field The force on a charge q moving with a velocity The magnitude of the force.
General Physics II, Additional Questions, By/ T.A. Eleyan 1 Additional Questions Lec. 15,16.
Basic radiation protection & radiobiology
Alpha and Beta Interactions
Magnetic Fields. Definition : A magnetic field is a force field which surrounds either a magnet or a wire carrying an electric current and will act upon,
Lecture 10  Relationship Between Wavelength, Frequency, Energy, and Velocity of Light  Production of Positron Emitters  Image of the Week.
Chapter 8 Charges in Magnetic Fields. Introduction In the previous chapter it was observed that a current carrying wire observed a force when in a magnetic.
Lecture 9, March 29 PET Physics Review Image of the Week.
Magnetic Forces and Magnetic Fields
Determining Radiation Intensity
Book Reference : Pages To understand that the path of a charged particle in a magnetic field is circular 2.To equate the force due to the magnetic.
 A model of beam line built with G4Beamline (scripting tool for GEANT4)  Simulated performance downstream of the AC Dipole for core of beam using  x.
Eric Prebys, FNAL.  We consider motion of particles either through a linear structure or in a circular ring USPAS, Hampton, VA, Jan , 2015 Longitudinal.
Interaction of Radiation with Matter
Lecture 4 Longitudinal Dynamics I Professor Emmanuel Tsesmelis Directorate Office, CERN Department of Physics, University of Oxford ACAS School for Accelerator.
1 Motion in Electric Fields SACE Stage 2 Physics.
Medical application of proton accelerators
Beam dynamics and linac optics studies for medical proton accelerators
Motion of Charges in Electric Fields. Electric Potential Difference.
3 July July July Conventional X-rays Generator Basic components of an X-ray machine:  Electron source.  Vacuum where electrons were.
Kuanjun Fan Institute of applied electromagnetic engineering
M. D. Anderson Cancer Center Houston, TX
Force on an Electric Charge Moving in a Magnetic Field
Charged Particles in Electric and Magnetic Fields
Synchrotron Ring Schematic
Diatomic molecules
November 14, 2008 The meeting on RIKEN AVF Cyclotron Upgrade Progress report on activity plan Sergey Vorozhtsov.
Interaction of Radiation with Matter
November 7, 2008 The meeting on RIKEN AVF Cyclotron Upgrade Progress report on activity plan Sergey Vorozhtsov.
Summary & Concluding remarks
Chapter 5 - Interactions of Ionizing Radiation
G. A. Krafft Jefferson Lab Old Dominion University Lecture 3
Machine Sources of Radiation
CYCLOTRON PREPARED BY Dr. P. K. Sharma.
Rectifiers. Introductions of rectifiers: IN PARTICLE ACCELERATORS, ELECTRONS OR OTHER CHARGED PARTICLES ARE FORCED TO MOVE ALONG ORBITS OR TRAJECTORIES.
CfE Higher Unit 2 – Particles and Waves
Accelerators.
Presentation transcript:

Clinical Neutron Therapy Center Donna Kubik Spring, 2005

CNTS With special thanks to Ruedi Risler and Steve Daley for technical guidance and friendship!

CNTS The Clinical Neutron Therapy System (CNTS) at the University of Washington is a computer controlled cyclotron and neutron therapy treatment facility Located in University Hospital on Portage Bay in Seattle, Washington

CNTS CNTS provides proton beams which are used to produce –fast neutrons for cancer treatments –proton and other charged particle beams for medical radionuclide production –particles for experiments in medical physics and radiobiology

Scanditronix MC50 The CNTS system uses a Scandtronix MC50 cyclotron Accelerates protons to 51 MeV Can also accelerate deuterons, alpha particles ( 4 He ++) and 3 He ++ ions

Scanditronix MC50 A linear accelerator could be used, but a cyclotron, being a circular machine, is more compact This is an advantage in a hospital-based facility when space is often restricted

Major components Magnet –Keeps particles on circular orbit –Focuses beam RF –Accelerates beam

Major components Ion source –Produces particles to be accelerated Extraction system –Guides particles out of the cyclotron Vacuum system Cooling system Diagnostics (beam probe)

Scanditronix MC40 Zoom on next slide The MC40 is a lower-energy cyclotron; Similar to the MC50

Scanditronix MC40 cyclotron Orange part is magnet yoke Wire at top is ion source Tall square columns are RF cavity tuners Extraction line with quad triplet Green things are vacuum valves

Ion source Dual ion source The gas containing the desired ion (hydrogen at CNTS) is admitted into the chimney in the center of the machine A negative voltage is applied between two cathodes at the top and bottom of the chimney creating an arc The magnetic field causes the electrons (in the arc) to spiral up and down the chimney

Ion source The spiraling electrons collide with gas molecules, ionizing them in the process The positive ions are extracted through a narrow slit in the chimney by the electric field from the dee tip whenever the dee is negative

RF system In early cyclotrons, there were 2 accelerating electrodes that were formed like the two halves of a closed pillbox cut in half Because of their shape, they were called dees

RF system The name has remained even though the shape of the accelerating structures of modern machines look quite different The MC50 has two wedge- shaped dees with a tip angle of 90 degrees

RF system The particles are accelerated by the electric field at the edge of the dees The polarity of the field is alternated such that a particle encounters an accelerating field each time it crosses a dee boundary Inside the dee (and in the 90 degree system also between the dees) there is a field-free area where the particles just coast.

Harmonic modes A cyclotron can be operated in several harmonic modes In the first harmonic mode, the frequency of the acceleration voltage equals the revolution frequency of the particle, in the second harmonic mode, the RF freq is twice the revolution freq, etc

Push-pull mode At CNTS, the protons are accelerated in the first harmonic mode, so the RF frequency is equal to the revolution frequency The dees are operated in push-pull mode This means that at any given moment one dee has the opposite polarity from the other

Cyclotron principle The RF frequency,  equals the revolution frequency Notice that, at non-relativistic velocities, the revolution freq is independent of R

Cyclotron principle But, to be relativistically correct, the mass should be replaced by As the particles speed up, the revolution frequency decreases and the particles are no longer in the correct phase relative to the alternating dee voltage

Cyclotron principle Protons become relativistic at about 30 MeV At 50 MeV,  0.30 So, at CNTS, relativistic effects are important But with a fixed RF frequency, how can the beam be kept in synch with the alternating RF?

Cyclotron principle The solution is to increase the magnetic field as a function of radius in order to compensate for the relativistic effect

Magnet The magnetic field is created by an electromagnet 90 ton steel yoke Main coil with current up to 900 A Average field 1.8 Tesla 1.4 m diameter pole pieces

Shaping the magnetic field The necessary increase of field with larger radii is accomplished by –Proper shaping of steel –10 concentric circular coils in upper and lower pole pieces The current in each of these 10 pairs can be adjusted individually

AVF All modern cyclotrons are azimuthally varying field (AVF) machines The magnetic field is not uniform in all azimuthal directions The field strength varies as the particle progress along their circular orbits This results in focusing and defocusing of the accelerating beam (Thomas focusing)

AVF This azimuthal field shaping is done with steel shims (hills) where the pole gap is reduced and the field strength is increased. These hills are separated by valleys The MC50 has 3 spiral shaped hills and three valleys

Harmonic coils Located in the three valleys are four sets of harmonic coils Harmonic coils A-C are used to correct particle paths to help keep the particles centered in the machine

Harmonic coils Harmonic could D (and circular coil 9) are used to excite coherent radial oscillations of the beam just inside the extraction radius

Extraction This resonance increases the spacing between successive turns. A narrow copper septum separates the particles in the last full orbit from the particles being guided out of the machine. The beam is guided out of the machine by an electric field between the deflector and (grounded) septum and some magnets internal to the machine It is possible to achieve extraction efficiencies of 60-85%

Extraction The mean extraction radius of the MC50 is 58.2 cm This radius, together with the RF frequency, determines the energy of the beam

Energy calculation for cyclotron The final energy of the particles is determined by –Velocity, v –RF frequency, f –Extraction radius, R With  and the rest mass, E o, the kinetic energy, T, of the particle can be calculated

Energy calculation for cyclotron For a 50 MeV beam, the RF freq. is 25.9 MHz, peak dee voltage of 40kV This means the particle make about 440 turns during acceleration The RF freq is well known, but the extraction radius is not as well known

Beamlines To patients Isotope production

Be target The protons hit the Be target The charged fragments (which contain protons from the Be nucleus) have a short range and are stopped in the target assembly The neutrons are very penetrating and leave the target

Dosimetry system A dosimetry system is downstream of the target It is comprised of a transmission ion chamber which measures the intensity of the beam The ion chamber is connected to an electrometer system which integrates the signal

Dosimetry system The dosimetry system is calibrated and is used to determine the dose delivered to the tumor and surrounding tissue For safety reasons, the dosimeter system is split into two completely independent systems with dual chambers, power supplies, electrometers and means to terminate treatments

Multileaf collimator The neutrons are then collimated and used for the irradiation of cancerous tissue

Protons vs. neutrons Protons deposit a larger fraction of their energy in a localized spot (Bragg peak), hence are more suited for cancers near sensitive structures as the optic nerve, spinal cord, etc However, slow-growing tumors spend a relatively short time in the dividing phase of the cell cycle, when they are most sensitive to ionizing radiation (as that of protons and photons) Bragg peak

Protons vs. neutrons These tumors are more- effectively treated with neutrons. Neutrons interact with the atoms in a tumor cell via nuclear interactions. Neutrons don’t just ionize atoms in the tumor cells, but the interactions result in breaking apart the atoms, forming new, or different, atoms

Protons vs. neutrons But neutrons loose energy more gradually as they pass through tissue (no Bragg peak) For neutron therapy, it is especially important to minimize the exposure to healthy tissue Note that, while neutrons (as well as photons) have no Bragg peak, neutrons and photons DO have skin sparing, while protons do not. Neutrons lose energy more-gradually

Isocentric beam delivery An isocentric beam delivery system is essential so that the patient can be irradiated from several different angles This concentrates the dose at the tumor and limits the dose to normal tissue CNTS employs an isocentric gantry system as shown on the right

Isocentric beam delivery Isocentric treatment can also be accomplished by rotating the patient or rotating the beam. From a relativistic point of view, it does not matter whether you rotate the beam or the patient. The result is the same.

Isocentric beam delivery Fermilab’s Neutron Therapy Facility has been doing isocentric treatment with a rotating patient immobilization platform since Neutron therapy has been very successful in treatment of many types of cancer