The cryogenic neutron EDM experiment at ILL and the result of the room temperature experiment James Karamath University of Sussex.

Slides:



Advertisements
Similar presentations
Andreas Knecht1ZH Doktorandenseminar 2009, 4. – 5. Juni 2009 A Gravitational Spectrometer for Ultracold Neutrons Andreas Knecht Paul Scherrer Institut.
Advertisements

Magnetic shielding calculations and also Petr Volegov Andrei Matlashov Michelle Espy LANL, P-21, SQUID team Igor Savukov.
W. M. Snow Physics Department Indiana University/IUCF EDM collab meeting Monitoring the Cold Neutron Beam (During Experiment) What to measure (fluence.
Spin Filtering Studies at COSY and AD Alexander Nass for the collaboration University of Erlangen-Nürnberg SPIN 2008, Charlottesville,VA,USA, October 8,
IKON7, Instrument clip session, September 2014, ESS Headquarters and Medicon Village, Lund, Sweden A cold neutron beamline for Particle
SQUID NMR Measurements in nEDM experiment -- how to get a big signal & how to operate SQUIDs in High Voltage Environments Chen-Yu Liu.
The electron EDM search in solid ferroelectric Eu 0.5 Ba 0.5 TiO 3 Alex Sushkov Steve EckelSteve Lamoreaux.
Another Route to CP Violation Beyond the SM – Particle Dipole Moments Dave Wark Imperial/RAL WIN05 Delphi June 10, 2005.
Philip Harris University of Sussex (for the EDM Collaboration) The Neutron EDM Experiments at the ILL.
B. Lee Roberts, HIFW04, Isola d’Elba, 6 June p. 1/39 Future Muon Dipole Moment Measurements at a high intensity muon source B. Lee Roberts Department.
Search for the Electron Electric Dipole Moment Val Prasad Yale University Experiment: D.DeMille, D. Kawall, R.Paolino, V. Prasad F. Bay, S. Bickman, P.Hamilton,
Lepton Moments 2014 Craigville 07/22/2014 P. Schmidt-Wellenburg PSI Searching for the electric dipole moment of the neutron.
Study of the Time-Reversal Violation with neutrons
1 Neutron Electric Dipole Moment Experiment Jen-Chieh Peng International Workshop on “High Energy Physics in the LHC Era” Valparaiso, Chile, December 11-15,
Experimental Atomic Physics Research in the Budker Group Tests of fundamental symmetries using atomic physics: Parity Time-reversal invariance Permutation.
Measurement of the electron’s electric dipole moment
UCN optics, polarization foils and spinflipper for the munich nEDM approach Thorsten Lauer.
Electric Dipole Moment of Neutron and Neutrinos
NEUTRON EDM Philip Harris, on behalf of the CryoEDM collaboration: Rutherford Appleton Laboratory University of Oxford University of Sussex ILL University.
1/30Peter Fierlinger FERMILAB Diamond-like Carbon for Ultra-cold Neutrons Peter Fierlinger.
Magnetic/Electric Fields for KEK-RCNP EDM Experiment K. Matsuta(Osaka), Y. Masuda(KEK), Y. Watanabe(KEK), S.C. Jeong(KEK), K. Hatanaka(RCNP), R. Matsumiya.
Motivation Polarized 3 He gas target Solenoid design and test 3 He feasibility test Summary and outlook Johannes Gutenberg-Universit ä t Mainz Institut.
Ultrahigh precision observation of nuclear spin precession and application to EDM measurement T. Inoue, T. Furukawa, H. Hayashi, M. Tsuchiya, T. Nanao,
Future electron EDM measurements using YbF
Ultracold neutrons and neutron decay Oliver Zimmer ILL Grenoble / TU München 19th Int. IUPAP Conf. On Few-Body Problems in Physics Bonn, 14 July 2008.
Low-frequency nuclear spin maser and search for atomic EDM of 129 Xe A. Yoshimi RIKEN SPIN /10/11-16 Trieste, ITALY Collaborator : K. Asahi (Professor,
Mitglied der Helmholtz-Gemeinschaft July 2015 | Hans Ströher (Forschungszentrum Jülich) EPS Conference on High Energy Physics, July 2015, Vienna.
Beam Polarimetry Matthew Musgrave NPDGamma Collaboration Meeting Oak Ridge National Laboratory Oct. 15, 2010.
Duke nEDM Collaboration Meeting The status of 3 He Relaxation Time Measurement at ~400mK Q. Ye, D. Dutta, H. Gao, W. Zheng, X. Zhu Duke University R. Golub,
A new measurement of the electron’s electric dipole moment using YbF molecules Mike Tarbutt Centre for Cold Matter, Imperial College London. International.
Molecular Deceleration Georgios Vasilakis. Outline  Why cold molecules are important  Cooling techniques  Molecular deceleration  Principle  Theory.
Separate production cell. Geometry and dimensions If the filling time is much shorter then the accumulation time then maximum of UCN density in the measurement.
G-2 accelerator and cryo needs Mary Convery Muon Campus Review 1/23/13.
CryoEDM at ILL Philip Harris.
2007/11/02nEDM BOSTON1 Dressing Field Study Pinghan Chu University of Illinois at Urbana-Champaign nEDM Collaboration Boston Dressed.
DOE 2/11/05 #1 EDM R&D Progress Steve Lamoreaux, Los Alamos Co-spokesperson for the EDM Project for presentation to The Department of Energy Cost & Schedule.
CryoEDM – A Cryogenic Neutron-EDM Experiment Collaboration: Sussex University, RAL, ILL, Kure University, Oxford University Hans Kraus … but before: some.
Electric-Dipole Moment Searches * Philip Harris *(mainly neutron)
+ - The proton EDM experiment in a purely Electric field storage ring Yannis K. Semertzidis, BNL Motivation of “Magic” pEDM with Sensitivity: e.
#1 “New” ILL EDM Experiment Systematic Comment on “An Improved Experimental Limit on the Electric-Dipole Moment of the Neutron,” C.A. Baker, et al. [1]
Collab_NSAC 4/2/03 #1 EDMEDM Martin Cooper, Los Alamos Co-spokesperson for the EDM Project for presentation to EDM Collaboration Meeting Los Alamos, NM.
Electric dipole moment searches E.A. Hinds Birmingham 11 th July 2011 Centre for Cold Matter Imperial College London.
Conceptual Design of the Neutron Guide Holding Field Christopher Crawford, Yunchang Shin University of Kentucky nEDM Collaboration Meeting
Alex Sushkov Dima Budker Valeriy Yashchuk (UC Berkeley) Kerr Effect-based Measurement of the Electric Field.
EDMEDM C&S Review 2/11/05 #1 Martin Cooper, Los Alamos Co-spokesperson for the EDM Project for presentation to LANL Cost and Schedule Review Committee.
The cryogenic neutron EDM experiment at ILL Technical challenges and solutions James Karamath University of Sussex.
Kerr Effect-based Measurement of the Electric Field
Switching with Ultrafast Magnetic Field Pulses Ioan Tudosa.
Electric Dipole Moment Searches in Nuclei, Atoms, and Molecules Dave Kawall - RIKEN BNL Research Center and UMass D S RBRC Symposium, BNL, June 19th, 2006.
1 B-field Uniformity Issues Two Basic Problems Depolarization of n and 3 He due to field gradients –Discussed in Pre-Proposal (2002) –Provided specification.
Mesure du moment électrique dipolaire du neutron Oscar Naviliat-Cuncic LPC-Caen et Université de Caen Basse-Normandie Journée de la division Champs et.
Assembly 12/14/06 #1 Assembly and Commissioning Paul Huffman.
Neutron and electron EDMs PPAP meeting, Birmingham, 18 th September 2012 Mike Tarbutt Centre for Cold Matter, Imperial College London.
Mitglied der Helmholtz-Gemeinschaft Development of 3D Polarimeters for storage ring EDM searches JEDI Collaboration | David Chiladze (IKP, Forschungszentrum.
Florian Piegsa – nnbar at ESS – June 13 th Florian Piegsa ETH Zürich – Institute for Particle Physics Magnetometry – nnbar at ESS.
Derek F. Jackson Kimball. Collaboration Dmitry Budker, Arne Wickenbrock, John Blanchard, Samer Afach, Nathan Leefer, Lykourgas Bougas, Dionysis Antypas.
INSTITUT MAX VON LAUE - PAUL LANGEVIN Measurement of parity-violating asymmetries in the reactions of light nuclei with polarized neutrons ( 6.
nEDM-2014, 2-6 November Crystal diffraction nEDM experiment. Present status Voronin Vladimir PNPI, Gatchina, Russia.
Philip Harris EDM Experiments PPAP, Birmingham 15/7/09.
Yannis K. Semertzidis Brookhaven National Laboratory New opportunities at CERN CERN, 12 May 2009 Storage Ring EDM Experiments The storage ring method can.
– + + – Search for the μEDM using a compact storage ring A. Adelmann 1, K. Kirch 1, C.J.G. Onderwater 2, T. Schietinger 1, A. Streun 1 1 Paul Scherrer.
Background simulations: update and simulations of absorbed dose
Precision experiments
Neutron and electron electric dipole moments
Using ultracold neutrons to constrain the neutron electric dipole moment Tamas Budner.
A new simultaneous spin analyser (USSA) for the PSI nEDM experiment
Electric Dipole Moments: Searches at Storage Rings
CRYOGENICS OPERATIONS 2008 Organized by CERN
EDM Experiments: UK interests
Electric Dipole Moments: Searches at Storage Rings
Presentation transcript:

The cryogenic neutron EDM experiment at ILL and the result of the room temperature experiment James Karamath University of Sussex

2 In this talk… (n)EDM motivation & principles Room-temperature nEDM experiment at ILL Systematics CryoEDM Summary James KaramathUniversity of Sussex28/06/ :08:36

3 (n)EDMs – so? I P- and T-violating CPV in SM not fully understood e.g. insufficient CPV for baryon asymmetry Strong CP problem  θ CP < rad. Axions? James KaramathUniversity of Sussex28/06/ :08:36 n n  p   × S + - d S - + d

4 (n)EDMs – so? II Estimated EDMs model dependent  SM d n ~ ecm  Other models typically times greater e.g. SUSY:  CP < quark electric dipole moments: qq  gaugino squark

5 nEDM measurement principle B0B0 E = + h/2 = - h/2 h (0) = -2μ.B h (  )= 2(-μ.B+d n.E) h (  )= 2(-μ.B-d n.E) B0B0 B0B0 E d n defined +ve ↑↑ - ↑↓ = Δ = 4d n.E / h Ramsey NMR performed on stored Ultra Cold Neutrons (UCN)

6 nEDM statistical limit Fundamental statistical limit α = visibility [polarisation product] E = E-field strength T = NMR coherence time N = total # counted ~ ecm James KaramathUniversity of Sussex28/06/ :08:36

7 nEDM systematic limit Main concern: changes in B-field accidentally correlated with E-field changes give false d n signal h( ν ↑↑ – ν ↑↓ ) = 2|μ n |(B ↑↑ –B ↑↓ ) – 4d n E True nEDM signal False signal due to varying B 

8 nEDM experiments: history Co-magnetometer era Cryogenic UCN era RT stored UCN eraBeam era ΔB ≈ v x E / c 2 limited

9 Current nEDM experiment at ILL I Create UCN, can then be guided & stored Polarise UCN UCN admitted into cell with E and B- fields and stored… Mercury polarised by Hg lamp and added to cell N S Storage cell Magnet & polarizing foil / analysing foil UCN Approx scale 1 m B E Magnetic field coil High voltage lead James KaramathUniversity of Sussex28/06/ :08:36 Magnetic shielding

10 Current nEDM experiment at ILL I Ramsey NMR performed Released from cell Neutrons spin analysed (# f n of precession) Repeat: E=↓or 0, B=↓ N S Magnetic shielding Storage cell UCN detector Approx scale 1 m Magnetic field coil B High voltage lead E Magnet & polarizing foil / analysing foil James KaramathUniversity of Sussex28/06/ :08:36

11 Current nEDM experiment at ILL II HV in B 0 field coils Ground electrode Neutron cell Mercury lamp light * Neutrons in/out * Mu-metal B-shields James KaramathUniversity of Sussex28/06/ :08:36 Z

12 Systematics I Reminder: B-field shifts correlated with E- field changes constitute false d n signal. Protect against incoming perturbations with mu-metal shields Measure changes IN cell with Mercury Cohabiting Magnetometer… James KaramathUniversity of Sussex28/06/ :08:36 h( ν ↑↑ – ν ↑↓ ) = 2|μ n |(B ↑↑ –B ↑↓ ) – 4d n E

13 Systematics II Hg EDM known to be below ~ ecm. Thus variations in mercury NMR signal are due to B-field fluctuations… Cohabiting Mercury Magnetometer James KaramathUniversity of Sussex28/06/ :08:36

14 Co-magnetometer correction Electric Field + - Systematics III

15 Co-magnetometer correction Systematics III

16 Co-magnetometer correction Systematics III

17 Systematics IV However, not perfect correction Mercury fills cell uniformly, UCN sag under gravity, lower by ~3 mm. Thus don’t sample EXACTLY the same B- field. Axial (z) gradients → problems… Magnetometer problems Hg n z James KaramathUniversity of Sussex28/06/ :08:36

18 Systematics V Two conspiring effects  v x E: motional particle in electric field experiences B-field: ΔB ≈ v x E / c 2  Axial field gradient dB/dz creates radial B-field (since .B=0) proportional to r, B r  r Let’s look at motion of a mercury atom across the storage cell Geometric Phase Effect (GPE)

19 Systematics VI Geometric Phase Effect (GPE) dB/dz → B  r B  v x E Scales with E like EDM!!! Scales with dB/dz (GPE Hg ~ 40GPE n ) Resultant i.e. B 0 field into page has gradient Shifts resonance of particle Using Mercury introduces error E and B 0 into page Rotating B field

20 Systematics VII Other EffectShiftUncertainty Statistical01.51 Door cavity dipole; quadrupole fields Other GP dipole shifts00.60 (E x v)/c 2 from translation00.05 (E x v)/c 2 from rotation00.10 Light shift: direct & GP B fluctuations00.24 E forces – distortion of bottle00.04 Tangential leakage currents00.01 AC B fields from HV ripple Hg atom EDM nd order Exv Total – stat, 0.80 sys GPE: J Pendlebury et al., Phys Rev A , 2004

21 Final result Room temperature experiment complete! Soon to be published result (PRL): d n = (+0.6  1.5(stat)  0.8(syst)) x ) ecm i.e.|d n | < 3.0 x ecm (90% CL) New cryogenic experiment will eventually be x100 more sensitive… hep-ex/

22 The cryogenic nEDM experiment Reminder: RTCryo N /day6x10 6 ~6x10 8 T /s~130~250  0.75~0.9 E /kV/cm~12~50 (B 0 /μT15) ~ ecm * * with new beamline x20 x5* x2 x1.2 x4

23 Improved production of UCN (↑N) I Crosses at 0.89nm for free (cold) n. Neutron loses all energy by phonon emission → UCN. Reverse suppressed by Boltzmann factor, He-II is at 0.5K, no 12K phonons. Dispersion curves for He-II and free neutrons James KaramathUniversity of Sussex28/06/ :08:36

24 Improved production of UCN (↑N) II Idea by Pendlebury and Golub in 1970’s, experimentally verified in 2002 (detected in He-II) for cold neutron beam at ILL (~1 UCN/cm 3 /sec). Also better guides – smoother & better neutron holding surfaces, Be / BeO / DLC → more neutrons guided/stored. Allows longer T too. James KaramathUniversity of Sussex28/06/ :08:36

25 Polarisation and detection (α) I Polarisation by Si-Fe multi-layer polarizer, 95±6% initial polarisation. Could lose polarisation in 2 ways:  “Wall losses” magnetic impurities in walls, generally not aligned with neutron spin  Gradients in B-field, if not smooth and steady have similar effect James KaramathUniversity of Sussex28/06/ :08:36

26 Polarisation and detection (α) II Detector: solid state, works in 0.5K He-II. n ( 6 Li, α) 3 H reaction - alpha and triton detected Thin, polarised Fe layer - spin analysis James KaramathUniversity of Sussex28/06/ :08:36

27 Improving the E-field (↑E) I He-II has high dielectric strength. However, many questions to study;  Nature of breakdown e.g. area/volume effects, purity effects…  Flow of current in/along surfaces in He-II  Effect on system of ~J energy breakdown in He-II (e.g. on electrode coatings, gas evolution) etc… James KaramathUniversity of Sussex28/06/ :08:36

28 Improving the E-field (↑E) II Test electrodes submerged in He-II in bath cryostat. Studying V max and I leak as function of d, T, dielectric spacers, purity… up to 130 kV. Some similar(ish) past data but varied results. E ±HV cryostat He-II (T, purity…) gap (d, V, spacers) Sussex HV tests ~20cm

29 Improving the E-field (↑E) III Past literature He-I data 4.2<T(K)<2.2

30 Improving the E-field (↑E) III Past literature He-II data 2.2<T(K)< K K

31 Improving the E-field (↑E) IV Now have a 400 kV supply to connect to HV electrode. Will sit in 3bar SF 6.

32 Magnetic field issues I Target – need ~ 100 fT stability (NMR) Need ~ 1 nT/m spatial homogeneity (GPE) Perturbations ~ 0.1 μT (buses!) Need (axial) shielding factor ~ 10 6 MMu-metal shielding~ 12 SSuperconducting shielding~ 8x10 5 AActive shielding (feedback coils)~ 15 Shielding factors

33 Magnetic field issues II CRYOGENIC nEDM! Utilise superconducting shield and B 0 solenoid. MMajor part of fluctuations across whole chamber (common mode variations) MMagnetometer (zero E-field) cells see same VVery stable B 0 (t) current Holding field x5 to reduce GPE in the neutrons by factor of 25 (GPE n  1/B 0 2 ) Extra benefits James KaramathUniversity of Sussex28/06/ :08:36 E

34 Magnetic field issues III ~fT sensitivity 12 pickup loops will sit behind grounded electrodes. Will show temporal stability of B-field at this level. Additional sensitivity from zero-field cell(s) SQUIDS

35 And so, the cryo-nEDM experiment I n guide tubes + spin analyser E ~ 60kV/cm E = 0kV/cm Spin flipper coil (measure other spin)

36 And so, the cryo-nEDM experiment II HV electrode Ground electrodes HV in z Carbon fibre support BeO spacers

37 And so, the cryo-nEDM experiment III HV electrode Ground electrodes G10 Superfluid containment vessel HV in z Neutrons in/out 250l He-II 0.5K * * * BeO spacers/guides

38 And so, the cryo-nEDM experiment IV 1m Dynamic shielding coils Magnetic (mu- metal) shields Superconducting shield and solenoid The shielded region

39 Schedule / Future Finish construction THIS SUMMER Start data taking THIS AUTUMN First results ~2008/9 Upgrade neutron guide to ↑N ~2009 ? James KaramathUniversity of Sussex28/06/ :08:36

40 Summary (n)EDMs help study T-violation and are constraining new physics. Systematics of RT-nEDM experiment well understood. Final RT result: |d n | < 3.0 x ecm. Cryo-nEDM project starts this Autumn, 2008/9 brings ~ mid ecm results. New beamline for low ecm. hep-ex/ (RT result)

41 Done! Thanks for listening