Mucool LH2 Absorber Progress and Pauses Mary Anne Cummings FNAL August 12, 2002.

Slides:



Advertisements
Similar presentations
Photo KEK March-28, 2002 MICE Absorber and Test Cryostat Shigeru Ishimoto (KEK) Shoji Suzuki (KEK) Edgar Black (IIT) Mary Anne Cummings (NIU) (1) MICE.
Advertisements

Feb. 9, 2002 Mucool FNAL LH2 Absorber R & D Mary Anne Cummings NIU Illinois Consortium for Accelerator Research (IIT, NIU, UC, UIUC), U Miss Oxford U.
11-13/10/2007 ILC BDS Kick-Off Meeting, SLAC, US 1 BDS Vacuum System Dr. Oleg B. Malyshev ASTeC Daresbury Laboratory.
Cooling Channel Count Recap Cooling channel components # Engineering? Absorber: temperature 8*3 yes pressure 2*3 yes He temp 2*3 level 8*3 yes length (optical)
Mucool meeting April 26, 2002 presentation Donna Kubik.
Vacuum Vessel Production Readiness Review
Mike Fitton Engineering Analysis Group Design and Computational Fluid Dynamic analysis of the T2K Target Neutrino Beams and Instrumentation 6th September.
MICE RF Cavity Design and Fabrication Update Steve Virostek Lawrence Berkeley National Laboratory MICE Collaboration Meeting October 27, 2004.
Upcoming Review of the Hall D Photon Beam and Tagger Richard Jones, University of Connecticut, for the GlueX collaboration GlueX Collaboration Meeting.
Magnet quench during a training run Magnet electrical circuit schematic PROGRESS ON THE MODELING AND MODIFICATION OF THE MICE SUPERCONDUCTING SPECTROMETER.
EXPERIENCE FROM KEK Norihito Ohuchi 2009/11/9-101 Workshop on cryogenic and vacuum sectorisations of the SPL.
LH2 Absorber Design Mary Anne Cummings MICE Safety Review LBL Dec 9, 2003.
The issue: A non-standard thin window design  No closed form expression for maximum stress vs. volume pressure  FEA (finite element analysis): geometry.
MICE LH2 Operating Parameters Mary Anne Cummings MICE October ‘02 LBL Oct. 24, 2002.
The structural and Fluid flow analyses of the Hydrogen Absorber Window for the Muon Cooling collaboration project Presented at the MICE meeting at IIT.
MICE Safety System DE Baynham TW Bradshaw MJD Courthold Y Ivanyushenkov.
MICE AFCSWG Safety Review Summary Mary Anne Cummings Dec. 17, 2003 MICE Video Conference.
Absorber/vacuum windows and absorber assembly 1.Window Requirements 2.MICE experimental constraints 3.Welded vs. non-welded windows 4.Installation 5.Testing.
2/7/2002 RolMUCOOL/MICE1 20b. Gaseous Energy Absorber, 21a. High Pressure RF Cavities New Money for New Approaches DOE Small Business Innovation Research.
Flammable Gas Electrical Safety Concerns for detectors: Power per channel Feedthroughs Seals.
LH2 Absorber Heat Load and Homeostasis. What has happened before… 1.Huge LH2 volumes, low heat deposition: Bubble chambers 2.Small LH2 volumes, low heat.
MuCool Test Facility Instrumentation Update M. Haney, D. Errede, Z. Conway University of Illinois at Urbana-Champaign 12/13 August 2002.
LH2 Absorber Design Mary Anne Cummings MICE Safety Review LBL Dec 9, 2003.
March 14, 2003 MICE Absorber/Coil Integration MICE LH2 Absorber 1.Assembly 2.Safety 3.Staging 4.Instrumentation.
Goal of MICE:   out /  in of   Assuming a standard (or agreed to) definition of 6-D cooling.  We can also assume that the tracker can give.
MICE absorber and Window / flow Design Wing Lau, Giles Barr & Stephanie Yang Oxford University MICE Meeting Berkeley, Oct 2002.
LH2 Absorber Design Mary Anne Cummings MICE Safety Review LBL Dec 9, 2003.
LH2 Manifold R & D 1.The driving physics issue in Mucool LH2 R & D is now fluid flow and heat removal 2.Two separate absorber designs 1.What is “certification”?
Absorber Design Details Mary Anne Cummings MICE MEETING Columbia June 13, 2003.
Mucool Test Area Cryostat & cooling-loop design Christine Darve Fermilab/Beams Division/ Cryogenic Department/ Engineering and Design Group MuCool / MICE.
Pre-alignment solutions applied to girders 1/19 Sylvain GRIFFET, 06/07/2010.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
17 March 2005Edda Gschwendtner1 MICE Cooling Channel: Can we predict cooling to ? Edda Gschwendtner Challenge Systematics Cooling Channel Beam Line.
Ans Pardons 30/11/2006CNGS Reflector Technical Review CNGS reflector: Status Work remains to be done… 30/10 Introduction Drain connection Event analysis.
Linac Test Area Instrumentation Update M. Haney, D. Errede, Z. Conway University of Illinois at Urbana-Champaign 14 June 2002.
MICE CM February 08Jean-Sébastien GraulichSlide 1 Detector DAQ Hardware Status o Introduction o Preliminary list o Plan for action o Summary Jean-Sebastien.
1 Fulvio TESSAROTTO Update on the thin RICH beam pipe project - prototypes validation and pipe production - microflanges and fixation system - the intervention.
R&D Status and Plan on The Cryostat N. Ohuchi, K. Tsuchiya, A. Terashima, H. Hisamatsu, M. Masuzawa, T. Okamura, H. Hayano 1.STF-Cryostat Design 2.Construction.
Edgar L. Black MUCOOL ADVANCED M.T.F. & M.I.C.E. LAYOUTS August 12-13, 2002 Edgar L. Black IIT.
M. A. C. C. NFMCC UCLA Jan 31, 2007 LH2 Absorber Status Mary Anne Cummings NFMCC UCLA January 31, 2007 Muons, Inc.
HAMBURG BEAM PIPE POSSIBLE LAYOUT AND MANUFACTURING JANUARY 2012.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
NLC MAC Meeting 6-8 Nov Linac Girder Studies and Plans C. Boffo Slide 1 Linac Girder Studies and Plans C. Boffo – E. Borissov – H. Carter Fermilab,
LH2 Absorber Review 1.R&D Motivation 2.Windows (absorber and vacuum) 3.Absorber manifold designs and flow tests 4.System integration 5.Near term plans.
BTeV Pixel Substrate C. M. Lei November Design Spec. Exposed to >10 Mrad Radiation Exposed to Operational Temp about –15C Under Ultra-high Vacuum,
Abstract: The Muon Ionization Cooling Experiment (MICE) is an international effort sited at Rutherford Appleton Laboratory, which will demonstrate ionization.
LH2 Absorber Program and Plans Mary Anne Cummings MUTAC Review FNAL Jan 14, 2003.
MCTF 8/17/06 A. Bross MTA Activities and Plans MCTF August 17, 2006 A. Bross.
LH2 Safety Issues for MICE 1.O2/LH2 separation 2.No Ignition sources near LH2 3.Adequate ventilation 4.Affects: Windows: absorbers and vacuum Primary and.
56 MHz SRF Cavity Thermal Analysis and Vacuum Chamber Strength C. Pai
Apr MUTAC 2005 LH2 Absorber Window R & D Program Mary Anne Cummings MUTAC Review LBL April 26, 2005.
2002 LHC days in Split Sandra Horvat 08 – 12 October, Ruđer Bošković Institute, Zagreb Max-Planck-Institute for Physics, Munich Potential is here...
9/17/07IRENG071 Cryogenic System for the ILC IR Magnets QD0 and QF1 K. C. Wu - BNL.
17/05/2010A. Rocchi - GWADW Kyoto2 Thermal effects: a brief introduction  In TM, optical power predominantly absorbed by the HR coating and converted.
MICE LH2 Absorber Safety Mary Anne Cummings Edgar Black (IIT) Abingdon, UK Oct. 30, 2003.
S1 global: thermal analysis TILC09, April 19th, 2009 Serena Barbanotti Paolo Pierini.
CDR2 – Coupler Mechanical Design NICOLAS MISIARA.
13 Januar 2011 Immanuel Gfall (HEPHY Vienna) Annekathrin Frankenberger (HEPHY Vienna) SVD Cooling Cooling Meeting Karlsuhe.
A 3D design model of the apparatus for the Laser Wakefield Acceleration of electrons at ELI-NP S. Balascuta1 , R. Dinca1 1) “Horia Hulubei” National.
MuCool Test Area Dedicated facility built at the end of the Linac to address MuCool needs RF power 805MHz, 201MHz)
A. Vande Craen, C. Eymin, M. Moretti, D. Ramos CERN
SILICON PIXELS DETECTOR
Vertex Detector Mechanical R&D Design Questions and Issues
CEPC Vacuum System Dong Haiyi 2017/11/5.
Linac Test Area Instrumentation
© 2004 – 2011 PAVAC Industries Inc. All rights reserved
MuCool Test Facility Instrumentation Update
Advanced Research Electron Accelerator Laboratory
Linac Test Area Instrumentation
BGC Collaboration Meeting –
Presentation transcript:

Mucool LH2 Absorber Progress and Pauses Mary Anne Cummings FNAL August 12, 2002

Cooling channel requires minimum “heating”  Low Z material  maximize radiation length  Minimize window thickness/Z while retaining structural integrity  Nonstandard window design Absorber Heat Management  Refrigeration: W heat deposition from beam (~8W/cm)  Temperature and density stability: LH2 circulation  Novel flow and convection schemes Mucool LH2 Absorber Issues Safety  No LH2/O2 contact: containment, ventilation, controls  No ignition sources: instrumentation must be “safe”, RF cavities “benign”  New instrumentation technology emittance eqn.: Design/test drivers:

“FNAL” Progress 1.Non-standard absorber windows designed 2.Non-standard vacuum containment window designed 3.5 & 9.5 mil thin windows manufactured 4.Correct FEA analyses completed with predictions for window performance under pressure 5.Photogrammetric techniques developed for volume measurements 6.Photogrammetric techniques developed for window pressure test performance 7.Window predictions and data consistent! 8.Test Area proposed and ALMOST on “mass shell”! 9.Test Area Absorber system designed.

“Offshore” Progress 1.Convection prototype built 2.Convection prototype cryogenically operated 3.Convection calculations 4.Three dimensional flow test demonstration 5.Schlieren test program started 6.NIM Articles in progress 7.Window predictions and data consistent!

The issue: A non-standard thin window design  No closed form expression for maximum stress vs. volume pressure  FEA (finite element analysis): geometry stress material strain volume pressure displacement Window tests } Procedure (for manufacture quality control and safety performance) Three innovations:  Precision measurement of window  photogrammetric volume measurements  FEA predictions  inelastic deformation, 3 – dim included in calcs.  Performance measurement  photogrammetric space point measurements

“Non-standard” thin windows Exploit the structural stability of the spherical cap with a tapered/inflected connection to a solid flange Modified torispherical window (Black/Cummings) “Bellows” inflected window (Black/Lau) XiXi t diameter R rr

How to determine the “thinnest” thickness 1.Two different radii of curvature 2.Possibly not concentric Modified torispherical design If not at the center, where?

Manufacture to rupture 130  window “350”  window “340”  window Burst at ~ 120 psi 4. Burst at ~ 151 psi Cryo test Leaking appeared at 31 psi..outright rupture at 44 psi! 1.

CMM vs. Photogrammetry 1.Contact vs. non-contact measurements 2.“Several” vs. ~ thousand measurements 3.Serial vs. parallel measurements 4.Larger vs. smaller equipment 5.Better fit to spherical cap.  Photogrammetry is choice for shape measurement

Strain gage vs. Photogrammetry 1.Contact vs. non-contact measurements 2.Smaller spot vs. extended length 3.No messy wiring on the window test setup! 4.Better systematics – no added material! 5.Better coverage!  Photogrammetry is choice for strain measurement

d 1AU r d p p scale bar fixed targets

Photogrammetry resolution convexconcave convex concave d R r Alignment of sides D’ Small triangle fit Use spherical fit of small triangles D =  m ( 5.5  m) + (- ~10  m)

Stress distribution at the yield point FEA Calculations Finite Element Analysis  Non-elastic region included  Three dimensios necessary for vibrational analysis Window/flange simulation Window/flange cross section FEA, non-elastic region included  Displacement vs. radius under pressure:  NIU photogrammetry results and FEA calculations

Window performance summary 1.Descrepancies between CMM and photogrammetry are larger than their intrinsic errors 2. Descrepancies between photogrammetry and FEA predictions are < 5%

Design of LINAC LH2 Absorber Beam Test x z   accelerator absorber Multiple scattering RF cavity Physicist’s vision Engineer’s vision

Heat Absorption and Temperature Maintenance 1.What are the usable predictions from simulations? 2.What are the meaningful measurements? 3.Radical changes: flat windows? Design: 1.What do we need for temp/density measurements? 2.Window heating 3.Strain gauging Monitoring:

Safety Review 1.Windows (absorber) holdup: MACC, FEA & data pts 2.Windows (Vacuum) holdup will be the same 3.Manifolds Mucool Responsibilities 4.Instrumentation Mucool 5.Cryogenics FNAL

The Near Program 1.MICE and FNAL LINAC program merge 2.Convection Absorber schedule for LINAC 3.Instrumentation and DAQ integration 4.The LINAC/MICE cooling cell designs

Experiment Signals- Absorber temperature12 pressure transducerssee under cryo 2 Photogrammetry/optical (??)2 laser occlusion sensor(??)4 piezo vibration sensors2 Optical fiber strain gauges2 bolometry44 O2 sensors 3per each of 5 flanges15 H2 sensors on exhaust line10 CCD camera 2 images MICE channels“N” #signals

Instrumentation 1.Temperature/density uniformity inside LH2 2.Safety instrumention inside vacuum area 3.Detectors for cooling measurements Safety Issues: 1. Limits the amount of energy/(area or vol) 2. Physical size of the signal feedthroughs 3. Seals from signals to electronics: wires fibers tubes