LEO Jon Paul Johnson’s Montage Ductile Iron Images.

Slides:



Advertisements
Similar presentations
Student Overview MMS Wireless Mobile Lab. Removing the laptops from the cart Each laptop is numbered. Each slot in the cabinet is numbered. Pick up your.
Advertisements

Working with Profiles in IX1D v 3 – A Tutorial © 2006 Interpex Limited All rights reserved Version 1.0.
Technology ICT Virtual PC. Network Resources Microsoft Virtual PC Allows multiple Guest Operating Systems (Virtual Machines) run using the resources of.
Google Picasa Simple Sharing & Photo Editing May 2011Moore Memorial Library Public Computer Center | Greene, NY1.
Introduction to Operation of the XL-30 Scanning Electron Microscope Tutorial # 1 Overview of XL-30 Microscope Control Program.
Microsoft Excel. Click on “Start,” then “Microsoft Office Excel.”
 Use the Left and Right arrow keys or the Page Up and Page Down keys to move between the pages. You can also click on the pages to move forward.  To.
Bio-Rad Labs. Chromatic Aberration Sources and Measurement.
RoboCell and Cell Setup
By Aaron Proia and Matthew Copenhaver.  For this presentation, we will be walking you through two processes that are commonly used in Photoshop.  These.
FEI NovaNano FEG-SEM 630. Technical Objective To train you to use the FEI FEG HR-SEM electron microscope High vacuum operation for conductive samples.
Tutorial – “How to:” 1) Change the resolution on your display 2) Setup Multiple Displays.
1. Pump down the chamber from the atmosphere pressure 2. Using RHEED to obtain diffraction images 3. Open the RHEED chamber or venting from high vacuum.
Tool bar and button bar (Many SEM functions are mouse-controlled)
Flatbed scanning in the HoA Computer Room How to use the Epson scanner.
Inventory Throughout this slide show there will be hyperlinks (highlighted in blue) follow the hyperlinks to navigate to the specified Topic or Figure.
EXCEL BASICS WELCOME  TODAY’S CLASS WILL COVER :  Moving Around Excel – CELLS  Highlighting, Editing, Formatting.
Introduction to Operation of the XL- 30 Scanning Electron Microscope Tutorial # 2 Introduction to Operation and Imaging.
Operation of the S4700 FESEM
Google Earth How to create a Google Earth Tour and place it in your Wiki.
Introducing the LEO 1400 Series
The LEO axis motorisation as standard High performance electron optics Intuitive easy to use graphical interface Multiple port chamber accessories.
Introduction to Computers Connie Dalrymple. What is a computer? Sources:
Downloading and Installing PAF Insight PAF Insight can be easily downloaded Or can be installed from a CD A license is needed t0 activate the program.
Power Point EDU 271 Microsoft PowerPoint is a powerful tool to create professional looking presentations and slide shows. PowerPoint allows you to construct.
MSET 365 Digital Imaging Technologies. MSET 365 The Sony Mavica.
STEP 1: Determining the exact image width STEP 1: Determining the exact image width Position of X-ray Filter Position of X-ray Filter STEP 5: Crop Extra.
European Computer Driving Licence Syllabus version 5.0 Module 4 – Spreadsheets Chapter 22 – Functions Pass ECDL5 for Office 2007 Module 4 Spreadsheets.
CIS—100 Chapter 15—Windows Vista 1. Parts of a Window 2.
Thank you for your decision to try vTreePro Practice Tree Software! Your satisfaction is very important to us. Please feel free to send us an if.
 Starting Excel 2003  Using Help  Workbook Management  Cursor Management  Manipulating Data  Using Formulae and Functions  Formatting Spreadsheet.
OST Introduction to Excel Excel 2004 The Project Gallery is a window that links you to every application in Microsoft Office. It allows.
October 15 click! 1 Computer Basics Kitsap Regional Library.
How to make a Power Point Relationship Narrative By Lisa Williams.
Elementary Campuses. Mouse on mouse pad Chair pushed in neatly Keyboard straight Logged off Helping hand on left side Headphones neatly setting on right.
CAD3D Project. SketchUp - Project Create a new SketchUp project called InitialsXX where the XX are your first and last initial. Use the Rectangle tool.
Downloading and Installing Autodesk Revit 2016
Change in your CAD Project File - it happens all the time in robotics.
XP New Perspectives on Windows 2000 Professional Windows 2000 Tutorial 2 1 Microsoft Windows 2000 Professional Tutorial 2 – Working With Files.
Computer Skills /1436 Department of Computer Science Foundation Year Program Umm Alqura University, Makkah Place photo here 1.
BioRad Sputter Coater  Instructions for gold coating a SEM sample.  NO, it’s not your eyes. This image is out of focus.
This is what we want to draw Extrude Mirror Round Edges.
Design Studies 20 ‘Show Off’ Project How to make a computer monitor In Google Sketchup By: Liam Jack.
Lesson 1 - Understanding the Word Window and Creating a New Document
JDS5 Training Guide. On Start Up you will see this screen click the OK button Click OK.
2D Design – A Guide! SECTION 1.
The LEO 1420VP Compact design ideal for small and medium sized samples
Word and the Writing Process. To create a document 1.On the Start menu, point to Programs, and then click Microsoft Word. A new document opens in Normal.
Microscopes Viewing the Unseen World. Microscopes Devices that produce magnified images of structures that are too small to see with the unaided eye.
Maryknoll Wireless Network Access Steps for Windows 7 As of Aug 20, 2012.
COMPUTER LITERACY 1 TRANSITION PLUS BASIC COMPUTER USE PART 1.
Welcome to the Basic Microsoft Word Guide. Before you start this Guide, you will need to complete “Basic Computer”; “Basic Windows” and know how to type.
Microsoft Word 2010 Lesson 1 Revised February 9, 2011
35mm slide scanning in the HoA Visual Resources Centre
Fastest way for already created documents
Word and the Writing Process
The LEO 1430VP 5 axis motorisation as standard
The LEO 1420 Compact design ideal for small and medium sized samples
Microsoft Windows 2000 Professional
Microsoft Word 2010 Lesson 1.
Computer Basics Last Updated: 2007.
How to Use poll everywhere
Inserting Pictures and Symbols in Word documents
Chapter 1: Digital Communication Tools
The LEO axis motorisation as standard
Web Design Holden School
Quanta FIB Basic Training xT Microscope Control
Basic Operational Instructions
Quanta FIB Basic Training Eucentric, Pt Deposition, and Trenching
Apreo FE-SEM Basic Training xT Microscope Control & Operation
Presentation transcript:

LEO Jon Paul Johnson’s Montage Ductile Iron Images

LEO Technical Objective To train you to use the electron microscopes on lower campus Start with the Leo 440i –We control it! –It’s currently running –Once you have learned the concepts on one microscope, in principle everything else is “knobololy” (Figuring out where the knobs are that control the feature you want to use.)‏ –It’s not easy or expensive to break (please don’t prove me wrong!)‏

LEO Vac-ion Pump Column “Upper Valve ” Chamber —10 -7 Torr Column Valve Electron gun Turbo- molecular pump —10 -8 Torr 760—10 -3 Torr Stage Sample Penning gage Oil Filter Exhaust Pumping system for Leo W-filament SEM (actually LaB 6 )‏ Oil-sealed Rotary Mechanic al Pump

LEO Leo 440i SEM Column Electron gun Aperture adjustment micrometers Chamber valve Upper valve Turbomolecular pump behind here

LEO Leo SEM: rear of column Vac-ion pump Everhard- Thornley Detector Gun

LEO EDS side of SEM LN2 tank Beam blanker

LEO Oil-sealed rotary mechanical pump

LEO Administrative matters Nothing in life is free Log onto the SEM with the sheet on the desktop Enter your name Enter the name and contact information of whoever will be paying Record how many times you coated samples Click on “View/Status”. Enter the filament lifetime when you start. Enter the time of day when you start. Repeat the last two steps when you finish.

LEO Notes on the computer The SEM is about 15 years old. It runs on a 66 MHz 486 under Windows Plan on having to reboot at least once per day. In windows 3.11 you cycle among active applications with ALT TAB. (Hold down ALT; every time you hit TAB, it cycles one application.)‏

LEO Getting started with the Leo Typical conditions when you walk in: –Ion pump is running –Chamber is under vacuum –“Upper valve” (gun valve) is closed –Column valve is open –All pumps are running

LEO Sample Mounting Leo uses mounting stubs with 1/8” shafts Carbon tape (double sticky) is simplest Carbon dots have lower vapor pressure Multiple samples can be mounted on turret Make a drawing in your research notebook of the locations of your samples on the turret Single mount is easiest for tilting Vertical mount is also an option Tighten gently with Allen wrench; ditto for sample holder on stage

LEO To insert your sample Check vacuum –Stage/vac –Vacuum status Chamber pressure should be – Torr Column pressure should be few x Torr Close column valve Vent (Stage/vac, Specimen change or right yellow arrow)‏ Insert sample. Remember where samples are! Close and latch door. Do not overtighten! Pump (Stage/vac, Specimen change or right yellow arrow)‏ After the pressure goes below Torr you may open the column valve and turn on the beam.

LEO

Drop Down List Box and Tool Bar (nearly all SEM functions are mouse-controlled)‏ Beam on Beam off Standby Pump Vent Vacuum control Left mouse buttonMiddle mouse button Roll mouse left to decrease value Roll mouse right to increase value Alternatively, double click on a box to enter data directly

LEO Go! Turn on beam Turn up brightness Hopefully you will see something Optimize beam Backup plan –If you fail to get an image, under File/(run) Standard! These are factory-installed parameters

LEO Decide on operating parameters 40 kV for highest resolution 20 kV for EDX Low voltage for optimum topography and least damage 100 pA for good resolution 300 pA for EDX for better signal-to-noise 25 mm WD for EDX 7 – 8 mm WD for maximum resolution

LEO Center of Stage (Red square)‏ Beam location (Blue square)‏ Cursor! Stage will move in direction of arrow when left mouse button is depressed Speed increases with distance cursor is from beam

LEO Use when OptiBeam is off OptiBeam on

LEO Pictoral explanation of gun shift Filiment Gun tilt lens aperature With the gun shift centered, the electron beam heads straight down the column. The image is brighter and can also be focused better. Otherwise the image moves when you change focus.

LEO Center filament image with “Tilt” option

LEO Adjust beam shift when OptiBeam is turned on

LEO Voila! An image!

LEO Optimize image Start with low magnification Look for dirt or some large feature Move feature to center of screen Go to reduced raster…Why? Focus Increase magnification…preferably 2-5X what you will use for the image you record. Why? Focus Iterate Full screen image

LEO Saving an image Get good quality image –2 minute scans over a few kX –Faster scans at lower magnification Under “Image/Noise reduction”, click on “Freeze at end”

LEO

Saving images, cont’d Under “File/Export tiff”, choose e:\ as the destination. The E:\ drive is mapped to the support PC that is next to the machine. From this machine you can use a USB memory stick or transfer files through the internet-- web mail or file transfer.E:\ Enter a filename: 6 characters (related to your sample) + 2-digit counter (00)‏ All students need to bring their own USB stick; files are approximately 1 MB

LEO Check “Export/Photo setup” to assure it is not set to “HRRU”!